1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 16035:2012Hardware performance sheet (HPS) Identification and summary of test evidence to facilitate the inter-changeability of building hardware for application to fire re
2、sisting and/or smoke control doorsets and/or openable windows BS EN 16035:2012 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 16035:2012.The UK participation in its preparation was entrusted to TechnicalCommittee B/538/2, Doors.A list of organizations represent
3、ed on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2013. Published by BSI Standards Limited 2013ISBN 978 0 580 6
4、9520 9 ICS 91.190 Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 2013.Amendments issued since publicationDate Text affectedBS EN 16035:2012EUROPEAN S
5、TANDARD NORME EUROPENNE EUROPISCHE NORM EN 16035 December 2012 ICS 91.190 English Version Hardware performance sheet (HPS) - Identification and summary of test evidence to facilitate the inter-changeability of building hardware for application to fire resisting and/or smoke control doorsets and/or o
6、penable windows Fiche de performance des quincailleries (HPS) - Identification et rcapitulatif des essais justificatifs visant faciliter linterchangeabilit des quincailleries de btiment destines tre installes sur des blocs-portes et/ou des fentres ouvrantes rsistant au feu et/ou pare-fumes Baubeschl
7、ge - Leistungsbeschreibung - Identifizierung und Zusammenfassung der Prfnachweise zur Untersttzung der Austauschbarkeit von Baubeschlgen fr die Anwendung an feuerwiderstandsfhigen und/oder rauchdichten Toren, Tren und/oder zu ffnenden FensternThis European Standard was approved by CEN on 27 October
8、2012. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtaine
9、d on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-C
10、ENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, I
11、taly, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix
12、 17, B-1000 Brussels 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 16035:2012: EBS EN 16035:2012 EN 16035:2012 (E) 2 Contents Page Foreword .3 Introduction 4 1 Scope .5 2 Normative references . 5 3 Terms and definitions . .5
13、 4 General principles of the Hardware Performance Sheet (HPS) . 6 4.1 General .6 4.2 Tasks for manufacturers and Notified Bodies . 6 5 Determination of the data for the interchangeability of building hardware . 7 5.1 General .7 5.2 Required Data Building hardware identification (see A.1) . 7 5.2.1 M
14、anufacturer (Position 1) . .7 5.2.2 Manufacturers Product Reference (Position 2) . .7 5.2.3 Type of Building Hardware (Position 3). .7 5.2.4 EN Standard (Position 4) . .7 5.2.5 Classification (Position 5) . .7 5.2.6 Main Dimensions (Position 6) . .7 5.2.7 Remarks (Position 7) . .8 5.3 Required Data
15、Test Evidence Used (see A.2) . .8 5.4 Required Data Performance Level(s) (see A.3) . 8 Annex A (normative) Hardware Performance Template . 9 A.1 Building hardware identification . 9 A.2 Test evidence used . . 10 A.3 Performance level(s) . 11 Annex B (informative) How to use the HPS . . 12 Bibliograp
16、hy 13 BS EN 16035:2012 EN 16035:2012 (E) 3 Foreword This document (EN 16035:2012) has been prepared by Technical Committee CEN/TC 33 “Doors, windows,shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a nati
17、onal standard, either by publication of an identicaltext or by endorsement, at the latest by June 2013, and conflicting national standards shall be withdrawn atthe latest by June 2013. Attention is drawn to the possibility that some of the elements of this document may be the subject of patentrights
18、. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organisations of the followingcountries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cypr
19、us, CzechRepublic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece,Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Ki
20、ngdom. BS EN 16035:2012 EN 16035:2012 (E) 4 Introduction For the purposes of this European Standard, the term “doorset” is used as a general term to cover pedestriandoorsets and industrial, commercial and/or garage doorsets with fire resistance and/or smoke controlcharacteristics. The term “openable
21、 window” in this European standard is used for openable windows with fire resisting and/orsmoke control characteristics. NOTE 1 Cf. also the definition of doorset and openable window as given in 3.1 and 3.2. The purpose of this European Standard is to simplify the collection of data for the intercha
22、ngeability of buildinghardware on fire resisting and/or smoke control doorsets and/or openable windows. It may enable a door orwindow manufacturer to have the possibility to fit different building hardware from that which has been testedon his door or openable window against the relevant resistance
23、to fire and/or smoke leakage characteristicsmentioned in the European product standard FprEN 16034. The Hardware Performance Sheet (HPS) therefore is a common checklist for the doorset and/or openablewindow manufacturer, building hardware manufacturer and/or Notified Bodies. A Hardware Performance S
24、heet is a summary of test and extended application evidence (“data sheet”),designed to facilitate the interchangeability of building hardware for application to fire resisting and/or smokecontrol doorsets and/or openable windows. The requirements for the classification and use of alternative buildin
25、g hardware are given in EN 14600. Permitted variations are given in the direct application clauses of the different parts of EN 1634 and in thedifferent parts of EN 15269 (extended application). These cover (e. g.): fixing details, increase or decrease of the number of locking points, alternative ma
26、terial(s), alternative supplier(s), fitting positions, etc. A building hardware element can have a positively or negatively influence on the fire resisting class of thedoorset or openable window. It is evident that variations in method and material of construction, direction ofexposure to fire, size
27、 and mass will all have an effect on the overall performance of a doorset and/or openablewindow. NOTE 2 For example, during a fire test, all types of doorsets and openable windows bend and deflect. This is due tocertain forces and torques and the amount of deflection varies with the material and met
28、hod of construction used, and alsowith its design. The fixing of building hardware to a smoke control doorset may effect its smoke tightness due to cut outs,penetration or specific fixing methods. It is important to know that by using an alternative element of building hardware there shall be no ant
29、icipateddecrease or increase in classification for the doorset or openable window on which it is fitted. It is essential toknow the type of door or window which the hardware has been tested on and the classifications achieved. BS EN 16035:2012 EN 16035:2012 (E) 5 1 Scope This European Standard appli
30、es to all building hardware elements intended to be used on fire resisting and/orsmoke control doorsets and/or openable windows. This European standard specifies templates which shall be used to summarise performance and otherrelevant information of building hardware elements, relating to existing d
31、urability of self-closing, fire resistanceand/or smoke control test evidence. Other performance characteristics required are given in FprEN 16034. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and areindispensable for its application
32、. For dated references, only the edition cited applies. For undated references,the latest edition of the referenced document (including any amendments) applies. EN 1154,1)Building hardware Controlled door closing devices Requirements and test methods EN 1191, Windows and doors Resistance to repeated
33、 opening and closing Test method EN 1634-1, Fire resistance and smoke control tests for door, shutter and openable window assemblies andelements of building hardware Part 1: Fire resistance tests for doors, shutters and openable windows EN 1634-2, Fire resistance and smoke control tests for door, sh
34、utter and openable window assemblies andelements of building hardware Part 2: Fire resistance characterisation test for elements of buildinghardware EN 1634-3, Fire resistance and smoke control tests for door and shutter assemblies, openable windows andelements of building hardware Part 3: Smoke con
35、trol test for door and shutter assemblies EN 12605, Industrial, commercial and garage doors and gates Mechanical aspects Test methods EN 13501-2, Fire classification of construction products and building elements Part 2: Classification usingdata from fire resistance tests, excluding ventilation serv
36、ices EN 14600, Doorsets and openable windows with fire resisting and/or smoke control characteristics Requirements and classification EN 15269 (all parts), Extended application of test results for fire resistance and/or smoke control for door,shutter and openable window assemblies, including their e
37、lements of building hardware FprEN 16034, Pedestrian doorsets, industrial, commercial, garage doors and windows Product standard,performance characteristics Fire resistance and/or smoke control characteristics 3 Terms and definitions For the purpose of this document, the following terms and definiti
38、ons apply. 3.1 doorset pedestrian doorset, industrial, commercial and/or garage doorset, rolling shutter and/or operable fabriccurtains including any frame or guide, door leaf or leaves, rolling or folding curtain, etc., which is provided togive a fire resisting and/or smoke control capability when
39、used for the closing of permanent openings in fire 1) This document is currently impacted by the stand-alone amendment EN 1154:1996/A1:2002. BS EN 16035:2012 EN 16035:2012 (E) 6 resisting separating elements, which includes any side panel(s), vision panel(s), flush over panel(s), transompanel(s) and
40、/or glazing together with the building hardware and any seals (whether provided for the purposeof fire resistance or smoke control or for other purposes such as draught or acoustics) which form theassembly and fulfilling the provisions of this European Standard under the responsibility of one identi
41、fiedmanufacturer 3.2 openable window window with one or more moveable elements including any fixed or removable side or overpanel(s), perimeterframe and relevant elements of building hardware Note1 to entry: Windows without any openable elements are not subject to fire resistance testing for doorset
42、s, but tothe testing for partitions to EN 1364-1. 3.3 interchangeability possibility, under the responsibility of the doorset or openable window manufacturer, to use elements ofbuilding hardware which differ from those tested in the original doorset or openable window withoutcompromising its perform
43、ance characteristics 4 General principles of the Hardware Performance Sheet (HPS) 4.1 General The objective of the HPS is not to permit a total interchangeability of the building hardware of a doorset and/oropenable window for the operations of maintenance or rehabilitation. Prior to consideration o
44、f interchangeability of building hardware in accordance with the EN 15269 series, theHPS shall be completed. 4.2 Tasks for manufacturers and Notified Bodies The manufacturer shall obtain an extended application report from a Notified Body in accordance with theEN 15269 series. Therefore, a reliable
45、performance verification system for building hardware is needed topermit the door and/or openable window manufacturer the use of alternative hardware components. All building hardware products shall comply with the relevant harmonised building hardware productstandards. The HPS shall be part of the
46、technical documentation delivered to a Notified Body by an applicant for anExtended application report, prior to CE marking. It is the responsibility of the Notified Body to check whetherits content is correct and up-to-date. The content of the HPS shall come from official test reports whose precise
47、 identification (e.g. test reportnumber and test house) shall be mentioned. The interchangeability of building hardware shall be validated by the Notified Body and cannot be onlydecided by a manufacturer or an installer. The hardware performance sheet shall be completed: by the hardware manufacturer
48、 or by the door manufacturer or by the Notified Body. BS EN 16035:2012 EN 16035:2012 (E) 7 NOTE The hardware performance sheet in Annex A gives an example of a door closing device with the minimuminformation to be provided which will enable door, window and building hardware manufacturers to obtain
49、an extendedapplication report from a Notified Body in order to allow the use of alternative hardware. More than one HPS data sheet (as described in Annex A) can be necessary to describe the various types ofbuilding hardware. HPS data sheet should be filled out for various types of building hardware to ensure that acomplete collection of data for interchangeability of building hardware on fire resistance and/or smoke controldoorsets and/or openable windows is available. 5 Determination of the data for the interchangeabil