1、BRITISH STANDARD BS EN 180101:1995 Specification for Harmonized system of quality assessment for electronic components Blankdetail specification Fixedfibre optic attenuators The European Standard EN180101:1995 has the status of a British StandardBSEN180101:1995 BSI 03-2000 ISBN0580 35833X Committees

2、 responsible for this British Standard The preparation of this British Standard was entrusted to Technical Committee EPL/86, Fibre optics, upon which the following bodies were represented: BECCAMA (BEAMA Electrical Cable and Conductor Accessory Manufacturers Association) British Approvals Service fo

3、r Cables British Cable Makers Confederation British Telecommunications plc Department of Trade and Industry (National Physical Laboratory) ERA Technology Ltd Federation of the Electronics Industry Fibreoptic Industry Association (FIA) Ministry of Defence National Supervising Inspectorate (BSI QA) Op

4、tical Sensors Collaborative Association Society of Cable Television Engineers Amendments issued since publication Amd. No. Date CommentsBSEN180101:1995 BSI 03-2000 i Contents Page Committees responsible Inside front cover National foreword ii Foreword 2 Foreword iii Text of CECC80101 1BSEN180101:199

5、5 ii BSI 03-2000 National foreword This British Standard has been prepared by Technical Committee EPL/86, and is the English language version of EN180101:1995, Blank detail specification: Fixed fibre optic attenuators, published by the Electronic Components Committee (CECC) of the European Committee

6、 for Electrotechnical Standardization (CENELEC). This standard lists the ratings, characteristics and inspection requirements which shall be included as mandatory requirements in any detail specification for this type of attenuator. Detail specifications shall conform to the requirements of this bla

7、nk detail specification and BS CECC00111 Rule of Procedure11. Specifications Part4:1991 Regulations for CECC detail specifications. The British Standard which implements the CECC Rules of Procedure is BS9000 General requirements for a system for electronic components of assessed quality Part2:1991 S

8、pecification for the national implementation of the CECC system. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity

9、from legal obligations. Cross-references Publication referred to Corresponding British Standard CECC80000 BS EN180000:1995 aHarmonized system of quality assessment for electronic components. Generic specification. Fibre optic attenuators a In preparation. Summary of pages This document comprises a f

10、ront cover, an inside front cover, pagesi andii, theEN title page, page2, theCECC title page, pagesiitoiv, pages1to15 andabackcover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.E

11、UROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN180101 June 1995 Supersedes CECC80101:1994 English version Blank detail specification: Fixed fibre optic attenuators Spcification particulire cadre: Attnuateurs fixes de fibres optiques Vordruck fr Bauartspezifikation: Festwert-Lichtwellenleiter (LW

12、L) Dampfungsglieder This European Standard was approved on 1995-03-06. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliog

13、raphical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility

14、of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherland

15、s, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels 1995 Copyright

16、 reserved to CENELEC members Ref. No. EN180101:1995 EEN180101:1995 BSI 03-2000 2 Foreword At the request of Working Group CLC/TC CECC/WG27, the text of CECC80101:1994, Issue1, was submitted to the formal vote for conversion into a European Standard. It was approved by CENELEC as EN180101 on1995-03-0

17、6. The following date was fixed: latest date by which the ENhas to be implemented atnational level by publication of an identical national standard or by endorsement (dop) 1996-03-01CECC80101:1994 ii BSI 03-2000 Contents Page Foreword iii 1 Introduction 1 2 Qualification approval 1 3 Quality conform

18、ance inspection 1 4 Preparation of detail specification (DS) 1 Table 1 Fixed sample inspection test schedule 6 Table 2 Lot-by-lot inspection test schedule (Groups A and B) 7 Table 3Periodic test inspection schedule (Groups C and D) 8 Table 4 Details, measurements and performance requirements 9CECC80

19、101:1994 BSI 03-2000 iii Foreword The CENELEC Electronic Components Committee (CECC) is composed of those member countries of the European Committee for Electrotechnical Standardization (CENELEC) who wish to take part in a harmonized System for electronic components of assessed quality. The object o

20、f the System is to facilitate international trade by the harmonization of the specifications and quality assessment procedures for electronic components, and by the grant of an internationally recognized Mark, or Certificate, of Conformity. The components produced under the System are thereby accept

21、able in all member countries without further testing. This specification has been formally approved by the CECC, and has been prepared for those countries taking part in the System who wish to issue national harmonized specifications for FIBRE OPTIC ATTENUATORS TYPE: FIXED. It should be read in conj

22、unction with the current regulations for the CECC System. At the date of printing of this specification, the member countries of the CECC are Austria, Belgium, Denmark, Finland, France, Germany, Ireland, Italy, theNetherlands, Norway, Portugal, Spain, Sweden, Switzerland and theUnitedKingdom, and co

23、pies of it can be obtained from the addresses shown on the blue fly sheet. Preface This blank detail specification (BDS) was prepared by CECC WG27. It is based, wherever possible, on the Publications of the International Electrotechnical Commission. The text of specification was circulated to the CE

24、CC for voting in the documents listed below and was ratified by the President of the CECC for printing as a CECC specification. AVIS This specification is published initially in English and French. The German text will follow as soon as it has been prepared. Document Date of Voting Report on the Vot

25、ing CECC(Secretariat)2613 January 1991 CECC(Secretariat)2699iv blankCECC80101:1994 BSI 03-2000 1 1 Introduction This specification is a BDS for Fibre Optic Attenuators of the fixed type. This includes instructions for preparing a DS. 2 Qualification approval 2.1 Procedure The DS shall state the qual

26、ification approval procedure to be used in accordance with 3.3 of CECC80000. 2.2 Test schedule and performance requirements The test schedule for qualification by the fixed sample procedure shall be given in Table 1 of the DS (seeclause4.4). 3 Quality conformance inspection 3.1 Lot-by- lot inspectio

27、n The test schedule for lot-by-lot inspection (groups A and B) shall be given in Table 2 of the DS (seeclause4.4). 3.2 Periodic inspection The test schedule for periodic inspection (groups C and D) shall be given in Table 3 of the DS (seeclause4.4). 4 Preparation of detail specifications (DS) Each B

28、DS is published separately as a pro forma document, with numbered spaces provided for entering the information necessary to create a DS. If the spaces provided are too small, then the information shall be provided on additional sheets forming part of the completed DS. Instructions for filling in the

29、 numbered spaces in a BDS are given below. (1) The name of the ONH under whose authority the DS is published and, if applicable, the organization from whom the DS is available. (2) The CECC symbol and the number allotted to the DS by the CECC General Secretariat. (3) The number and issue number of t

30、he CECC GS; also the national reference(s), if different. (4) If different from the CECC number, the national number of the DS, date of issue and any further information required by the national system, together with any amendment numbers. (5) A brief description of the component or range of compone

31、nts. (6) The level of quality assessment (A, B, C or X), sampling procedure (fixed quantity or lot-by-lot) and the climatic category. For(5) and(6) the text to be given in the DS shall be suitable for an entry in CECC00200 Register of Approvals and CECC00300 Register of national Documents. (7) An ou

32、tline drawing with main dimensions which are of importance for interchangeability, and/or reference to the appropriate national or international document for outlines. Alternatively, this drawing may be given in an annex to the DS, but(7) shall always contain an illustration of the general outer app

33、earance of the component. If an existing drawing from an IEC publication, or similar source, is used in a CECC specification, then it can be either first or third angle projection, but the appropriate symbol shall be shown on the drawing: 1st angle projection 3rd angle projection The symbol in the B

34、DS may be converted to indicate either1st or3rd angle, by deleting the inappropriate part of the drawing. Alternative outline dimensions or tolerance limits of any variants shall be shown, and may be listed in the form of a table alongside the drawing.CECC80101:1994 2 BSI 03-2000 (8) A list of varia

35、nts and their identifying features covered by the DS. Enter the identification number. “AYY” for each variant of each component (see 2.7.1 of CECC80000). Assign a column in the table for each variant feature. For example, cable type, housing, orientation of ports, means of mounting etc. (9) Suppleme

36、ntary information Enter the supplementary information with respect to marking of the component, marking and contents of package, ordering information, related documents, certified test records and structural similarity. (10) Fixed-sample qualification approval test schedule Table 1 shall give the re

37、quired measurements and tests for qualification by fixed-sample procedure. If qualification by lot-by-lot and periodic procedure is specified, insert “NOTAPPLICABLE” in Table 1. If measurements or tests are specified for which no basic procedure is available, or which do not appear in the GS, CECC80

38、000, each procedure shall be clearly described in an individual annex to the DS. The format shall be the same as that used in the GS. (11) Lot-by-lot inspection test schedule When completed, Table 2 shall give the required measurements and tests for qualification by lot-by-lot procedure. One or more

39、 assessment level (s) shall be given in Table 2. When differing from the preferred levels of the GS (see 2.1.5 of CECC80000) the IL and AQL shall be entered and the assessment level (s) titled X, (Y), etc. If qualification by fixed-sample procedure is specified, insert “NOT APPLICABLE” in Table 2. I

40、f measurements or tests are specified for which no basic procedure is available, or which do not appear in the GS, CECC80000, each procedure shall be clearly described in an individual annex to the DS. The format shall be the same as that used in the GS. (12) Periodic C and D testing procedure Table

41、 3 shall give the required measurements and tests for groups C and D periodic tests. One or more assessment level (s) shall be given in Table 3. When differing from the preferred levels of the GS (see 2.1.5 of CECC80000) the IL, AQL, p, n, c, and t shall be entered and the assessment level(s) titled

42、 (X, Y). (13) Details, measurements, and performance requirements Table 4 shall list the details of each tests requirements. It shall be noted that the mandatory tests have been given as a minimum. Other tests shall be given in the same manner.CECC80101:1994 BSI 03-2000 3 NOTEAdditional drawings (if

43、 necessary) see page. (8) Variants: Variant No Attenuation Pigtail type Information about manufacturers who have components qualified to this detail specification is available in the current CECC00200 Register of Approvals.CECC80101:1994 4 BSI 03-2000 Figures continued . . 7) Alternative outline dim

44、ensions or tolerance limits of any variants Ref Dimensions Notes Min MaxCECC80101:1994 BSI 03-2000 5 (9) Supplementary information Marking of the component (add component marking requirements in accordance with 2.7.2 of CECC80000, as applicable: Making and contents of packages (add component package

45、s marking requirements in accordance with2.7.3 of CECC80000, as applicable): Ordering information (add ordering information, as applicable): Related documents (add additional related documents if not included in CECC80000): Certified records of released lots (indicate whether a certificate is requir

46、ed): Structural similarity (add the boundary limits in accordancewith 3.2 of CECC80000):CECC80101:1994 6 BSI 03-2000 (10) Table 1 Fixed sample inspection test schedule Test Sequence (Note1) n (Note2) GROUP0 . Group1 . Group2 . Group3 . Further groups if applicable . NOTE 1For details, measurements a

47、nd performance requirements see Table 4. NOTE 2n=Sample size.CECC80101:1994 BSI 03-2000 7 (11) Table 2 Lot-by-lot inspection test schedule (Groups A and B) Test Sequence (Note1) Assessment Level (Note2) Group A Group B Further groups if applicable NOTE 1For details, measurements and performance requ

48、irements see Table 4. NOTE 2The IL and AQL shall be specified if differing from the preferred levels in the GS (see2.1.5 of CECC80000).CECC80101:1994 8 BSI 03-2000 (12) Table 3 Periodic test inspection schedule (Groups C and D) Test Sequence (Note1) Assessment Level (Note2) Group C0 Group C1 Group C

49、2 Further groups if applicable Group D0 Group D1 Group D2 Group D3 Further groups if applicable NOTE 1For details, measurements and performance requirements see Table 4. NOTE 2The periodicity, sample size, Group Acceptance criteria and Total Acceptance criteria shall be specified if they differ from the preferred levels in the GS (see2.1.5)CECC80101:1994 BSI 03-2000 9 (13) Table 4 Details, measurements and performance requirements (see Note1) Visual inspection: CECC80000 clause4.4.1 Details: Configuration and connector type (if