1、BRITISH STANDARD BS EN 50065-4-5:2003 Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz Part 4-5: Low voltage decoupling filter Segmentation filter The European Standard EN 50065-4-5:2003 has the status of a British Standard ICS 31.160; 30.040.30; 97.120 BS
2、 EN 50065-4-5:2003 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 11 April 2003 BSI 11 April 2003 ISBN 0 580 41578 3 National foreword This British Standard is the official English language version of EN 50065-4-5:2003. The UK participation
3、in its preparation was entrusted to Technical Committee PEL/205, Mains signalling, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publ
4、ications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the ne
5、cessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the in
6、terpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 7 and a back cover. The BSI c
7、opyright date displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEAN STANDARD EN 50065-4-5 NORME EUROPENNE EUROPISCHE NORM January 2003 CENELEC European Committee for Electrotechnical Standardization Comit Europen de
8、 Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2003 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50065-4-5:2003 E ICS 31.160; 33.040.3
9、0; 97.120 English version Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz Part 4-5: Low voltage decoupling filter - Segmentation filter Transmission de signaux sur les rseaux lectriques basse tension dans la bande de frquences de 3 kHz 148,5 kHz Partie 4-
10、5: Filtres basse tension de dcouplage - Filtre de segmentation Signalbertragung auf elektrischen Niederspannungsnetzen im Frequenzbereich 3 kHz bis 148,5 kHz Teil 4-5: Niederspannungs- Entkopplungsfilter - Bereichsfilter This European Standard was approved by CENELEC on 2002-04-01. CENELEC members a
11、re bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to
12、 the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has th
13、e same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerlan
14、d and United Kingdom. EN 50065-4-5:2003 - 2 - Foreword This European Standard was prepared by SC 205A, Mains communicating systems, of Technical Committee CENELEC TC 205, Home and Building Electronic Systems (HBES). The text of the draft was submitted to the Unique Acceptance Procedure and was appro
15、ved by CENELEC as EN 50065-4-5 on 2002-04-01. The following dates were fixed: - latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2003-08-01 - latest date by which the national standards conflicting with the E
16、N have to be withdrawn (dow) 2005-04-01 EN 50065 consists of the following parts, under the general title: Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz Part 1 General requirements, frequency bands and electromagnetic disturbances Part 2-1 Immunity requ
17、irements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in residential, commercial and light industrial environments Part 2-2 Immunity requirements for mains communications equipment and systems operating in the range of
18、frequencies 95 kHz to 148,5 kHz and intended for use in industrial environments Part 2-3 Immunity requirements for mains communications equipment and systems operating in the range of frequencies 3 kHz to 95 kHz and intended for use by electricity suppliers and distributors Part 4-1 Low voltage deco
19、upling filters Generic specification Part 4-2 Low voltage decoupling filters Safety requirements Part 4-3 Low voltage decoupling filters Incoming filter Part 4-4 Low voltage decoupling filters Impedance filter Part 4-5 Low voltage decoupling filters Segmentation filter Part 4-6 Low voltage decouplin
20、g filters Phase coupler Part 7 Equipment impedance _ - 3 - EN 50065-4-5:2003 Contents Page 1 Scope .4 2 Normative references .5 3 Classification.5 3.1 Type 1: Asymmetrical filter .5 3.2 Type 2: Symmetrical filter.5 4 Requirements6 4.1 Marking.6 4.2 Electrical characteristics at mains frequency .6 4.
21、2.1 Overvoltage .6 4.2.2 Immunity 6 4.3 Electrical characteristics at signalling frequency6 4.3.1 Operating frequency range6 4.3.2 Impedance .6 4.3.3 Transfer function7 4.4 Safety7 Figure 1 - The application of segmentation filters .4 EN 50065-4-5:2003 - 4 - 1 Scope This standard applies to segmenta
22、tion filters in a mains communication system used for single or multiphase installations having a phase to neutral voltage not exceeding 250 V a.c. and a nominal current not exceeding 125 A, intended for household and similar fixed installation including residential, commercial and light industrial
23、buildings and utility networks. These filters (see Figure 1) are used to control the coupling of signals between two areas of a mains communication system. The standard defines the minimum impedance in the relevant frequency range(s) at both ports, the minimum attenuation of signals transmitted betw
24、een port. asymmetrical segmentation filter segment 1 segment 2 segment k asymmetrical segmentation filter asymmetrical segmentation filter symmetrical segmentation filter segment n segment port segment port segment port supply backbone portFigure 1 - The application of segmentation filters - 5 - EN
25、50065-4-5:2003 2 Normative references This European Standard incorporates by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendmen
26、ts to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies (including amendments). EN 50065-2-1 Signalling on low-voltage electrical installati
27、ons in the frequency range 3 kHz to 148,5 kHz Part 2-1: Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in residential, commercial and light industrial environments EN 50065-2-2 Signalling on low-volt
28、age electrical installations in the frequency range 3 kHz to 148,5 kHz Part 2-2: Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in industrial environments EN 50065-2-3 Signalling on low-voltage elect
29、rical installations in the frequency range 3 kHz to 148,5 kHz Part 2-3: Immunity requirements for mains communications equipment and systems operating in the range of frequencies 3 kHz to 95 kHz and intended for use by electricity suppliers and distributors EN 50065-4-1 Signalling on low-voltage ele
30、ctrical installations in the frequency range 3 kHz to 148,5 kHz Part 4-1: Low voltage decoupling filters - Generic specification EN 50065-4-2 Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz Part 4-2: Low voltage decoupling filters - Safety requirements 3
31、Classification Segmentation filters are used to separate one powerline communication system that operates in one operating frequency band, in several independent segments. The combination of the appropriate segmentation filter in conjunction with an incoming filter and/or with an impedance filter sh
32、all be made according to local regulations. 3.1 Type 1: Asymmetrical filter This filter has one “supply backbone port“ and one “segment port“. The “supply backbone port“ and the “segment port“ have different impedance characteristics in the operating frequency band and shall not be inverted. Communi
33、cation may not be possible on the “supply backbone port”. 3.2 Type 2: Symmetrical filter This filter has two “segment port“. Both “segment ports“ have the same impedance characteristics at the operating frequency band and may be inverted. Usually the ports of a symmetrical segmentation filter are co
34、nnected to different segments of one mains communication system. EN 50065-4-5:2003 - 6 - 4 Requirements 4.1 Marking In addition and in accordance with clause 8 of EN 50065-4-2: the operating frequency range f minto f max when relevant shall be marked; the attenuation within these bands. 4.2 Electric
35、al characteristics at mains frequency 4.2.1 Over voltage The filter shall meet the requirements in accordance with 15.2 of EN 50065-4-2 with overvoltage category III for segmentation filters used on the consumer network, overvoltage category IV for segmentation filters used on the utility network. 4
36、.2.2 Immunity Immunity is specified as follows: according to EN 50065-2-1 for segmentation filters in residential, commercial and light industrial environments; according to EN 50065-2-2 for segmentation filters in industrial environments; according to EN 50065-2-3 for segmentation filters in the ut
37、ility networks. 4.3 Electrical characteristics at signalling frequency 4.3.1 Operating frequency range The operating frequency range is a (reduced) frequency range the filter is designed for in the relevant band: it shall be in the frequency band 3 kHz to 95 kHz for utility segmentation filters; it
38、shall be in the frequency band 95 kHz to 148,5 kHz for consumer segmentation filters. The manufacturer shall specify the operating frequency range. 4.3.2 Impedance 4.3.2.1 Asymmetrical segmentation filter (type 1) On the segment port of the filter, when measured in the operating frequency range spec
39、ified by the manufacturer f minto f max , according to 6.1 of EN 50065-4-1, the modulus value of the impedance shall be greater than 10 . On the “supply backbone port” there is no requirement 4.3.2.2 Symmetrical segmentation filter (type 2) On both ports of the filter, when measured in the operating
40、 frequency range specified by the manufacturer f minto f max , according to 6.1 of EN 50065-4-1, the modulus value of the impedance shall be greater than 10 . - 7 - EN 50065-4-5:2003 4.3.3 Transfer function The transfer function and the measuring methods are defined in 6.2 of EN 50065-4-1. In the op
41、erating frequency range specified by the manufacturer f minto f max , the segmentation filter shall provide an attenuation specified by the manufacturer, in each direction when the filter is loaded with 5 on both sides. 4.4 Safety The filter shall meet the requirements given in EN 50065-4-1 and EN 5
42、0065-4-2. BS EN 50065-4-5:2003 BSI 389 Chiswick High Road London W4 4AL BSI British Standards Institution BSI is the independent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Chart
43、er. Revisions British Standards are updated by amendment or revision. Users of British Standards should make sure that they possess the latest amendments or editions. It is the constant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an inaccura
44、cy or ambiguity while using this British Standard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover. Tel: +44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400. BSI offers members an individual updating service called PLUS which e
45、nsures that subscribers automatically receive the latest editions of standards. Buying standards Orders for all BSI, international and foreign standards publications should be addressed to Customer Services. Tel: +44 (0)20 8996 9001. Fax: +44 (0)20 8996 7001. Email: ordersbsi-. Standards are also av
46、ailable from the BSI website at http:/www.bsi-. In response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as British Standards, unless otherwise requested. Information on standards BSI provides a wide range of information o
47、n national, European and international standards through its Library and its Technical Help to Exporters Service. Various BSI electronic information services are also available which give details on all its products and services. Contact the Information Centre. Tel: +44 (0)20 8996 7111. Fax: +44 (0)
48、20 8996 7048. Email: infobsi-. Subscribing members of BSI are kept up to date with standards developments and receive substantial discounts on the purchase price of standards. For details of these and other benefits contact Membership Administration. Tel: +44 (0)20 8996 7002. Fax: +44 (0)20 8996 700
49、1. Email: membershipbsi-. Information regarding online access to British Standards via British Standards Online can be found at http:/www.bsi- Further information about BSI is available on the BSI website at http:/www.bsi-. Copyright Copyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of the publications of the inte