1、BRITISH STANDARD BS EN 50065-4-6:2004 Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz Part 4-6: Low voltage decoupling filters Phase coupler The European Standard EN 50065-4-6:2004 has the status of a British Standard ICS 31.160; 33.040.30; 97.120 BS EN 5
2、0065-4-6:2004 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 25 November 2004 BSI 25 November 2004 ISBN 0 580 44889 4 National foreword This British Standard is the official English language version of EN 50065-4-6:2004. The UK participation
3、 in its preparation was entrusted to Technical Committee PEL/205, Mains signalling, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European pub
4、lications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the n
5、ecessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the i
6、nterpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 8, an inside back cover and
7、a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEAN STANDARD EN 50065-4-6 NORME EUROPENNE EUROPISCHE NORM July 2004 CENELEC European Committee for Electrotechnical Standardiz
8、ation Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2004 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50065-4-6:2004
9、E ICS 31.160; 33.040.30; 97.120 English version Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz Part 4-6: Low voltage decoupling filters Phase coupler Transmission de signaux sur les rseaux lectriques basse tension dans la bande de frquences de 3 kHz 148,
10、5 kHz Partie 4-6: Filtres basse tension de dcouplage Coupleur de phase Signalbertragung auf elektrischen Niederspannungsnetzen im Frequenzbereich 3 kHz bis 148,5 kHz Teil 4-6: Niederspannungs- Entkopplungsfilter Phasenkoppler This European Standard was approved by CENELEC on 2004-03-01. CENELEC memb
11、ers are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on applicati
12、on to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat h
13、as the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Pola
14、nd, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 50065-4-6:2004 2 Foreword This European Standard was prepared by SC 205A, Mains communicating systems, of Technical Committee CENELEC TC 205, Home and Building Electronic Systems (HBES). The text of the draft was sub
15、mitted to the Unique Acceptance Procedure and was approved by CENELEC as EN 50065-4-6 on 2004-03-01. The following dates were fixed: - latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2005-03-01 - latest date
16、 by which the national standards conflicting with the EN have to be withdrawn (dow) 2007-03-01 EN 50065 consists of several parts, under the general title: Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz Part 1 General requirements, frequency bands and el
17、ectromagnetic disturbances Part 2-1 Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in residential, commercial and light industrial environments Part 2-2 Immunity requirements for mains communications
18、 equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in industrial environments Part 2-3 Immunity requirements for mains communications equipment and systems operating in the range of frequencies 3 kHz to 95 kHz and intended for use by electricity sup
19、pliers and distributors Part 4-1 Low voltage decoupling filters Generic specification Part 4-2 *)Low voltage decoupling filters Safety requirements Part 4-3 Low voltage decoupling filters Incoming filter Part 4-4 Low voltage decoupling filters Impedance filter Part 4-5 Low voltage decoupling filters
20、 Segmentation filter Part 4-6 Low voltage decoupling filters Phase coupler Part 4-7*)Portable low voltage decoupling filters - Safety requirements Part 7 Equipment impedance _ *)This part covers the extended frequency ranges 3 kHz to 148,5 kHz and 1,6 MHz to 30 MHz. 3 EN 50065-4-6:2004 Contents 1 Sc
21、ope .4 2 Normative references .4 3 Definitions .5 4 Classification.5 4.1 Type 1 (standard type) .5 4.2 Type 2 (low leakage type) 5 5 Requirements5 5.1 Marking.5 5.2 Electrical characteristics at mains frequency .5 5.2.1 Over voltage 6 5.2.2 Immunity 6 5.2.3 Mains frequency leakage current 6 5.3 Elec
22、trical characteristics at signalling frequency7 5.3.1 Operating frequency range7 5.3.2 Transfer function7 5.3.3 Impedance .7 Figure 1 Mains frequency l eakage current test set up 6 Table 1 Mains frequency leakage current limits6 Annex A (normative) Special national conditions.8 EN 50065-4-6:2004 4 1
23、 Scope This European Standard applies to phase couplers in a mains communication system for phase to neutral voltage not exceeding 250 V a.c. and a nominal current not exceeding 125 A, intended for household and similar fixed installation including residential, commercial and light industrial buildi
24、ngs. This European Standard applies to phase couplers used to control the coupling of communication signals between phases or sections of a mains communication system. A phase coupler may be used to achieve coupling between the phases of a multiphase installation, or to provide bridging of signals a
25、round other system components. The standard defines the requirements to ensure a minimum coupling between the sections, and the requirements to ensure no change on the safety of the electrical installation. 2 Normative references The following referenced documents are indispensable for the applicati
26、on of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 50065-2-1 Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz Part 2-1: Imm
27、unity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in residential, commercial and light industrial environments EN 50065-2-2 Signalling on low-voltage electrical installations in the frequency range 3 kHz t
28、o 148,5 kHz Part 2-2: Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in industrial environments EN 50065-2-3 Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 k
29、Hz Part 2-3: Immunity requirements for mains communications equipment and systems operating in the range of frequencies 3 kHz to 95 kHz and intended for use by electricity suppliers and distributors EN 50065-4-1 Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5
30、 kHz Part 4-1: Low voltage decoupling filters Generic specification EN 50065-4-2 Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz Part 4-2: Low voltage decoupling filters Safety requirements 5 EN 50065-4-6:2004 3 Definitions For the purposes of this docume
31、nt, the terms and definitions given in EN 50065-1, EN 50065-4-1 and the following apply. 3.1 phase terminal (PT) connection to a phase conductor of the electrical installation in which the phase coupler is used 3.2 neutral terminal (NT) connection to a neutral conductor of the electrical installatio
32、n in which the phase coupler is used (may or may not be provided) 3.3 mains frequency leakage current r.m.s. value of any mains frequency current flowing between phase terminals 4 Classification The classification is made according to the mains frequency leakage current of the phase coupler. The fil
33、ter shall meet the requirements given in Part 4-2: Low voltage decoupling filters Safety requirements. 4.1 Type 1 (standard type) The coupling may be achieved with suitable capacitors. Due to significant mains frequency leakage current the use of this type of phase coupler may be limited for safety
34、reasons. 4.2 Type 2 (low leakage type) The coupling may be achieved using a transformer. 5 Requirements 5.1 Marking In addition and in accordance with EN 50065-4-2, Clause 8, the operating frequency range f minto f maxshall be marked, and the attenuation within the frequency range with a 10 load at
35、the output port shall be marked. 5.2 Electrical characteristics at mains frequency The filter shall meet the requirements given in Part 4-1: Low voltage decoupling filters Generic specification. EN 50065-4-6:2004 6 5.2.1 Over voltage The phase coupler shall meet the requirements in accordance with E
36、N 50065-4-2, subclause 7.1.5: overvoltage category III for phase couplers used on the consumer network; overvoltage category IV for phase couplers used on the utility network. 5.2.2 Immunity The phase coupler shall conform to the relevant specification: according to EN 50065-2-1 for phase coupler in
37、 residential, commercial and light industrial environments, according to EN 50065-2-2 for phase coupler in industrial environments, according to EN 50065-2-3 for phase coupler in the utility networks. 5.2.3 Mains frequency leakage current The mains frequency leakage current, at the nominal voltage,
38、is measured according to Figure 1. All terminals of the phase coupler are connected to the appropriate voltage, except one phase terminal that is connected to neutral through a gauge. LL1 PT1 PT2 PT3 NT 230 V a.c. A Phase couplerFigure 1 Mains frequency leakage current test set up NOTE 1 Repeat this
39、 measurement for all phase terminals provided by the phase coupler. NOTE 2 For multiport/multiphase device, each phase port is tested independently. The mains frequency leakage current of the phase coupler shall not exceed the following limits: Table 1 Mains frequency leakage current limits Type of
40、phase coupler Mains frequency leakage current (r.m.s. value) Type 1 30 mA Type 2 200 A 7 EN 50065-4-6:2004 5.3 Electrical characteristics at signalling frequency 5.3.1 Operating frequency range The operating frequency range shall be specified by the manufacturer within the relevant frequency band: 3
41、 kHz to 95 kHz for utility phase couplers, 95 kHz to 148,5 kHz for consumer phase couplers. 5.3.2 Transfer function The maximum attenuation between phase terminals measured according to EN 50065-4-1 subclause 6.2 with 10 resistive load shall not exceed the value specified by the manufacturer. 5.3.3
42、Impedance All active phase terminals are connected with a 10 resistive load. On one phase, the load is disconnected and the impedance is measured. The modulus of this impedance shall not be less than all resistors connected in parallel. EN 50065-4-6:2004 8 Annex A (normative) Special national condit
43、ions Special national condition: National characteristic or practice that cannot be changed even over a long period, e.g. climatic conditions, electrical earthing conditions. NOTE If it affects harmonization, it forms part of the European Standard. For the countries in which the relevant special nat
44、ional conditions apply these provisions are normative, for other countries they are informative. Clause Special national condition 5.2.3 Norway Add a third note: NOTE 3 The IT power distribution system is widely used, isolated from earth with a voltage limiter and the neutral not distributed. _ blan
45、kBS EN 50065-4-6:2004 BSI 389 Chiswick High Road London W4 4AL BSI British Standards Institution BSI is the independent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter. Revis
46、ions British Standards are updated by amendment or revision. Users of British Standards should make sure that they possess the latest amendments or editions. It is the constant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an inaccuracy or amb
47、iguity while using this British Standard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover. Tel: +44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400. BSI offers members an individual updating service called PLUS which ensures th
48、at subscribers automatically receive the latest editions of standards. Buying standards Orders for all BSI, international and foreign standards publications should be addressed to Customer Services. Tel: +44 (0)20 8996 9001. Fax: +44 (0)20 8996 7001. Email: ordersbsi-. Standards are also available f
49、rom the BSI website at http:/www.bsi-. In response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as British Standards, unless otherwise requested. Information on standards BSI provides a wide range of information on national, European and international standards thr