EN 50085-2-4-2009 en Cable trunking systems and cable ducting systems for electrical installations - Part 2-4 Particular requirements for service poles and service posts《电气装置用电缆槽和电.pdf

上传人:rimleave225 文档编号:716634 上传时间:2019-01-04 格式:PDF 页数:32 大小:883.97KB
下载 相关 举报
EN 50085-2-4-2009 en Cable trunking systems and cable ducting systems for electrical installations - Part 2-4 Particular requirements for service poles and service posts《电气装置用电缆槽和电.pdf_第1页
第1页 / 共32页
EN 50085-2-4-2009 en Cable trunking systems and cable ducting systems for electrical installations - Part 2-4 Particular requirements for service poles and service posts《电气装置用电缆槽和电.pdf_第2页
第2页 / 共32页
EN 50085-2-4-2009 en Cable trunking systems and cable ducting systems for electrical installations - Part 2-4 Particular requirements for service poles and service posts《电气装置用电缆槽和电.pdf_第3页
第3页 / 共32页
EN 50085-2-4-2009 en Cable trunking systems and cable ducting systems for electrical installations - Part 2-4 Particular requirements for service poles and service posts《电气装置用电缆槽和电.pdf_第4页
第4页 / 共32页
EN 50085-2-4-2009 en Cable trunking systems and cable ducting systems for electrical installations - Part 2-4 Particular requirements for service poles and service posts《电气装置用电缆槽和电.pdf_第5页
第5页 / 共32页
点击查看更多>>
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI British StandardsWB9423_BSI_StandardColCov_noK_AW:BSI FRONT COVERS 5/9/08 12:55 Page 1Cable trunking systems andcable ducting systems for electrical installations Part 2-4: Particular requirements fo

2、r service poles and service postsBS EN 50085-2-4:2009National forewordThis British Standard is the UK implementation of EN 50085-2-4:2009.The UK participation in its preparation was entrusted to Technical CommitteePEL/213, Cable management.A list of organizations represented on this committee can be

3、 obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2009 ISBN 978 0 580 59270 6 ICS 29.120.10Compliance with a British Standard cannot confer immunity from legal obligation

4、s.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 August 2009Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 50085-2-4:2009EUROPEAN STANDARD EN 50085-2-4 NORME EUROPENNE EUROPISCHE NORM June 2009 CENELEC

5、 European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: Avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide

6、 for CENELEC members. Ref. No. EN 50085-2-4:2009 E ICS 29.120.10 English version Cable trunking systems and cable ducting systems for electrical installations - Part 2-4: Particular requirements for service poles and service posts Systmes de goulottes et systmes de conduits-profils pour installation

7、s lectriques - Partie 2-4: Rgles particulires pour les colonnes et colonnettes Elektroinstallationskanalsysteme fr elektrische Installationen - Teil 2-4: Besondere Anforderungen fr freistehende Installationseinheiten This European Standard was approved by CENELEC on 2009-05-01. CENELEC members are b

8、ound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the

9、 Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the sa

10、me status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Nor

11、way, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 50085-2-4:2009EN 50085-2-4:2009 2 Foreword This European Standard was prepared by the Technical Committee CENELEC TC 213, Cable management systems. The text of the draft was submitted to the

12、formal vote and was approved by CENELEC as EN 50085-2-4 on 2009-05-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2010-05-01 latest date by which the national standards c

13、onflicting with the EN have to be withdrawn (dow) 2012-05-01 This European Standard is a system standard for cable management products used for electro-technical purposes. It relates to Low Voltage Directive 2006/95/EC 1)through consideration of the essential requirements of this directive. This Eur

14、opean Standard is supported by separate standards to which references are made. This Part 2-4 is to be used in conjunction with EN 50085-1:2005 “Cable trunking systems and cable ducting systems for electrical installations Part 1: General requirements”. This Part 2-4 supplements or modifies the corr

15、esponding clauses of EN 50085-1:2005. Where a particular clause or subclause of Part 1 is not mentioned in this Part 2-4, that clause or subclause of Part 1 applies as far as is reasonable. Where this Part 2-4 states “addition” or “replacement”, the relevant text of Part 1 is to be adapted according

16、ly. NOTE The following numbering system is used: subclauses, tables and figures that are additional to those in Part 1 are numbered starting from 101; additional annexes are lettered AA, BB, etc. _ 1)Directive 2006/95/EC of the European Parliament and of the Council of 12 December 2006 on the harmon

17、isation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits, OJ L 374, 27.12.2006, p. 1019. BS EN 50085-2-4:2009 3 EN 50085-2-4:2009 Contents Page 1 Scope . 4 2 Normative references 4 3 Definitions 5 4 General requirements . 5 5 General condit

18、ions for tests 5 6 Classification 6 7 Marking and documentation 7 8 Dimensions . 7 9 Construction . 7 10 Mechanical properties . 8 11 Electrical properties 15 12 Thermal properties . 16 13 Fire hazard . 16 14 External influences . 16 15 Electromagnetic compatibility 17 Annex A (informative) Types of

19、 cable trunking systems (CTS) and cable ducting systems (CDS) 22 Annex B (informative) A-deviations . 22 Annex C (normative) CTS/CDS IK code 22 Annex AA (normative) Use of test results according to EN 50085-2-4 for service poles and service posts being part of a CTS/CDS intended for wall or ceiling

20、mounting covered by EN 50085-2-1 or floor mounting covered by EN 50085-2-2 . 23 Annex AB (normative) Routine test for the socket outlets wiring of pre-wired service poles and service posts (correct polarity and protection against electric shock) 26 Figures Figure 101 Types and application of service

21、 poles and service posts 19 Figure 102 Detail of the cylinder for vertical load test in accordance with 10.5.103 20 Figure 103 Detail of the circular plate for vertical load test in accordance with 10.5.104 21 Tables Table AA.1 EN 50085-2-1 . 23 Table AA.2 EN 50085-2-2 . 24 Table AB.1 Diagrammatic r

22、epresentation of routine tests to be applied to the socket outlets wiring of pre-wired service poles and service posts 26 BS EN 50085-2-4:2009EN 50085-2-4:2009 4 1 Scope Replacement: This European Standard specifies requirements and tests for cable trunking systems (CTS) and cable ducting systems (C

23、DS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V a.c. and 1 500 V

24、 d.c. Service poles and service posts are intended to be mounted in free space and in contact with mounting surface(s) only at one or two ends, where the word “mounted” means fixed or placed on the floor with a weighted base or linked to a mounting surface through a flexible component. NOTE Service

25、poles and service posts can also be part of a CTS/CDS intended for wall or ceiling mounting covered by Part 2-1 or floor mounting covered by Part 2-2 and are then also tested according to Part 2-1 and/or Part 2-2 as appropriate. This European Standard does not apply to conduit systems, cable tray sy

26、stems, cable ladder systems, powertrack systems or equipment covered by other standards. This European Standard shall be used in conjunction with EN 50085-1:2005 “Cable trunking systems and cable ducting systems for electrical installations Part 1: General requirements” which is referred to in this

27、document as Part 1. 2 Normative references This clause of Part 1 is applicable except as follows: Add the following references: EN 20535 1994 Paper and board Determination of water absorptiveness Cobb method (ISO 535:1991) EN 50085-1 2005 Cable trunking systems and cable ducting systems for electric

28、al installations Part 1: General requirements EN 60068-2-75 1997 Environmental testing Part 2-75: Tests Test Eh: Hammer tests (IEC 60068-2-75:1997) EN 60695-11-2 2003 Fire hazard testing Part 11-2: Test flames 1 kW nominal pre-mixed flame Apparatus, confirmatory test arrangement and guidance (IEC 60

29、695-11-2:2003) EN 62262 2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) (IEC 62262:2002) EN ISO 536 1996 Paper and board Determination of grammage (ISO 536:1995) ISO 9328-7 2004 Steel flat products for pressure purposes Technic

30、al delivery conditions Part 7: Stainless steels BS EN 50085-2-4:2009 5 EN 50085-2-4:2009 3 Definitions This clause of Part 1 is applicable except as follows: Additional definitions: 3.101 service pole CTS/CDS intended to be mounted in free space and in contact with mounting surfaces only at two ends

31、 NOTE 1 Service pole can be part of a CTS/CDS intended for wall, ceiling or floor mounting. NOTE 2 The word “mounted” means fixed or placed on the floor with a weighted base or linked to a mounting surface through a flexible component. 3.102 service post CTS/CDS intended to be mounted in free space

32、and in contact with mounting surface only at one end NOTE 1 Service post can be part of a CTS/CDS intended for wall, ceiling or floor mounting. NOTE 2 The word “mounted” means fixed or placed on the floor with a weighted base or linked to a mounting surface through a flexible component. 3.103 pre-eq

33、uipped service pole / service post service pole / service post already assembled by the manufacturer or responsible vendor with one or more electrical accessories and/or communication components 3.104 pre-wired service pole / service post service pole / service post already assembled by the manufact

34、urer or responsible vendor, wired by means of insulated conductors and/or cables connecting one or more electrical accessories and/or communication components 3.105 modular service pole / service post service pole / service post which includes the assembly of two or more modules allowing to increase

35、 the height or width or depth of the product 3.106 rated current, rated voltage value assigned to a pre-wired and/or pre-equipped service pole / service post by the manufacturer and to which operation and performances characteristics are referred 4 General requirements This clause of Part 1 is appli

36、cable. 5 General conditions for tests This clause of Part 1 is applicable except as follows: 5.1 Replace by: 5.1 Unless otherwise specified, tests according to this standard are type tests. BS EN 50085-2-4:2009EN 50085-2-4:2009 6 Additional subclause: 5.101 Unless otherwise specified in the relevant

37、 test, service poles / service posts are tested on the longest version declared by the manufacturer and service poles / service posts which differ only by being shorter than one which complies with the requirements for a given test are deemed to comply with the requirements for the same test. 6 Clas

38、sification This clause of Part 1 is applicable except as follows: 6.4.1 This subclause of Part 1 is not applicable. Additional subclauses: 6.101 According to floor treatment for service poles / service posts placed on the floor 6.101.1 Service poles / service posts for dry-treatment of floor 6.101.2

39、 Service poles / service posts for wet-treatment of floor 6.102 According to resistance to vertical load applied through small surface area 6.102.1 CTS/CDS for 500 N 6.102.2 CTS/CDS for 750 N 6.102.3 CTS/CDS for 1 000 N 6.102.4 CTS/CDS for 1 500 N 6.102.5 CTS/CDS for 2 000 N 6.102.6 CTS/CDS for 2 50

40、0 N 6.102.7 CTS/CDS for 3 000 N 6.103 Optional classification according to resistance to vertical load applied through large surface area 6.103.1 CTS/CDS for 2 000 N 6.103.2 CTS/CDS for 3 000 N 6.103.3 CTS/CDS for 5 000 N 6.103.4 CTS/CDS for 10 000 N 6.103.5 CTS/CDS for 15 000 N BS EN 50085-2-4:2009

41、 7 EN 50085-2-4:2009 7 Marking and documentation This clause of Part 1 is applicable except as follows: 7.3 Add the following three last indents: - for modular service poles / service posts the constraints concerning the number or configuration of assembled modules; - whether non vertical mounting i

42、s allowed; - whether the flexible component, if any, linking to the mounting surface is not part of the enclosure. 8 Dimensions This clause of Part 1 is applicable except as follows: Addition: There are no dimensional requirements. 9 Construction This clause of Part 1 is applicable except as follows

43、: 9.1 Sharp edges Replace the second paragraph by: Compliance is checked by inspection using one sample, if necessary after cutting the samples apart. Replace the fourth paragraph by: Compliance is checked by inspection using one sample. 9.3 Means for protective separation and/or retention Replace t

44、he second paragraph by: Compliance is checked by the tests of 10.3 and 10.5. Additional subclause: 9.101 Service poles / service posts which are likely to be moved during use shall be provided with means to relieve conductors from strain in terminals or terminations. NOTE A service pole with a weigh

45、ted base is an example of service pole likely to be moved during use. A clamped service pole is not considered likely to be moved during use. When a cable anchorage is used, compliance is checked by inspection and by the test of 9.12. Other means are checked by the following test. After installation

46、 according to the manufacturers instructions a pull force of 100 N 2 N is applied to this mean in the most unfavourable direction for 60 s 5 s. During the application of the force there shall be no stress on insulated conductors. BS EN 50085-2-4:2009EN 50085-2-4:2009 8 9.102 Areas of service poles /

47、 service posts shall have adequate resistance to vertical load when both following conditions are fulfilled: these areas are reasonably subjected to vertical load during installation and/or application. Some areas of service poles or service posts are considered not to be subjected to vertical load

48、due to their dimensions or shape or height at least 100 mm above the floor; damage to these areas would impair mechanical or electrical safety. Compliance is checked by the test of 10.5.103 and, when a resistance to vertical load through large surface area is declared, by the test of 10.5.104. 9.103

49、 Insulated conductors and/or cables used to connect electrical accessories and/or communication components in pre-wired service poles / service posts shall be selected in accordance with the rated voltage of the connected equipment and, in case of electrical accessories, its rated current. Compliance is checked by inspection. 9.104 Service poles / service posts placed on the floor declared according to 6.101.2 shall avoid water coming into contact with insulated condu

展开阅读全文
相关资源
猜你喜欢
  • BS 1982-1-1990 Fungal resistance of panel products made of or containing materials of organic origin - Method for determination of resistance to wood-rotting Basidiomycetes《有机材料制成或.pdf BS 1982-1-1990 Fungal resistance of panel products made of or containing materials of organic origin - Method for determination of resistance to wood-rotting Basidiomycetes《有机材料制成或.pdf
  • BS 1982-2-1990 Fungal resistance of panel products made of or containing materials of organic origin - Method for determination of resistance to cellulose-decomposing microfungi《有机.pdf BS 1982-2-1990 Fungal resistance of panel products made of or containing materials of organic origin - Method for determination of resistance to cellulose-decomposing microfungi《有机.pdf
  • BS 1982-3-1990 Fungal resistance of panel products made of or containing materials of organic origin - Methods for determination of resistance to mould or mildew《有机材料制成或含有有机材料的板条制品.pdf BS 1982-3-1990 Fungal resistance of panel products made of or containing materials of organic origin - Methods for determination of resistance to mould or mildew《有机材料制成或含有有机材料的板条制品.pdf
  • BS 1983-1-1969 Specification for chucks for machine tools and portable power tools - Tool-holding chucks《机床与便携式电动工具用卡盘规范 刀具夹紧卡盘》.pdf BS 1983-1-1969 Specification for chucks for machine tools and portable power tools - Tool-holding chucks《机床与便携式电动工具用卡盘规范 刀具夹紧卡盘》.pdf
  • BS 1983-3-1987 Chucks for machine tools and portable power tools - Specification for dimensions of collet pads for base jaws of power operated workholding chucks《机床与便携电动工具用卡盘规范 第3部.pdf BS 1983-3-1987 Chucks for machine tools and portable power tools - Specification for dimensions of collet pads for base jaws of power operated workholding chucks《机床与便携电动工具用卡盘规范 第3部.pdf
  • BS 1983-4-1987 Chucks for machine tools and portable power tools - Specification of criteria to be stated affecting performance of power operated workholding chucks at speed《机床与便携电.pdf BS 1983-4-1987 Chucks for machine tools and portable power tools - Specification of criteria to be stated affecting performance of power operated workholding chucks at speed《机床与便携电.pdf
  • BS 1983-5-1989 Chucks for machine tools and portable power tools - Code of practice for the safe operation of workholding chucks used on lathes《机床与便携式电动工具用卡盘规范 第5部分 车床工作状态卡盘的安全操作实用.pdf BS 1983-5-1989 Chucks for machine tools and portable power tools - Code of practice for the safe operation of workholding chucks used on lathes《机床与便携式电动工具用卡盘规范 第5部分 车床工作状态卡盘的安全操作实用.pdf
  • BS 1990-1-1984 Wood poles for overhead power and telecommunication lines - Specification for softwood poles《架空输电与通讯线路用木杆 第1部分 软木杆规范》.pdf BS 1990-1-1984 Wood poles for overhead power and telecommunication lines - Specification for softwood poles《架空输电与通讯线路用木杆 第1部分 软木杆规范》.pdf
  • BS 1994-1993 Specification for dichloromethane (methylene chloride)《二氯甲烷规范》.pdf BS 1994-1993 Specification for dichloromethane (methylene chloride)《二氯甲烷规范》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有