EN 50153-2014 en Railway applications - Rolling stock - Protective provisions relating to electrical hazards (Incorporates Amendment A1 2017).pdf

上传人:wealthynice100 文档编号:716750 上传时间:2019-01-04 格式:PDF 页数:34 大小:1.06MB
下载 相关 举报
EN 50153-2014 en Railway applications - Rolling stock - Protective provisions relating to electrical hazards (Incorporates Amendment A1 2017).pdf_第1页
第1页 / 共34页
EN 50153-2014 en Railway applications - Rolling stock - Protective provisions relating to electrical hazards (Incorporates Amendment A1 2017).pdf_第2页
第2页 / 共34页
EN 50153-2014 en Railway applications - Rolling stock - Protective provisions relating to electrical hazards (Incorporates Amendment A1 2017).pdf_第3页
第3页 / 共34页
EN 50153-2014 en Railway applications - Rolling stock - Protective provisions relating to electrical hazards (Incorporates Amendment A1 2017).pdf_第4页
第4页 / 共34页
EN 50153-2014 en Railway applications - Rolling stock - Protective provisions relating to electrical hazards (Incorporates Amendment A1 2017).pdf_第5页
第5页 / 共34页
点击查看更多>>
资源描述

1、BSI Standards PublicationBS EN 50153:2014Railway applications Rollingstock Protective provisionsrelating to electrical hazardsBS EN 50153:2014 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 50153:2014. Itsupersedes BS EN 50153:2002 which is withdrawn.The UK par

2、ticipation in its preparation was entrusted to TechnicalCommittee GEL/9/2, Railway Electrotechnical Applications - Rollingstock.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of

3、 a contract. Users are responsible for its correctapplication. The British Standards Institution 2014. Published by BSI StandardsLimited 2014ISBN 978 0 580 73001 6ICS 45.060.10; 45.060.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was publish

4、ed under the authority of theStandards Policy and Strategy Committee on 31 May 2014.Amendments issued since publicationDate Text affectedBS EN 50153:2014EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 50153 May 2014 ICS 45.060.01 Supersedes EN 50153:2002English Version Railway applications - Ro

5、lling stock - Protective provisions relating to electrical hazards Applications ferroviaires - Matriel roulant - Mesures de protection vis-vis des dangers dorigine lectrique Bahnanwendungen - Fahrzeuge - Schutzmanahmen in Bezug auf elektrische Gefahren This European Standard was approved by CENELEC

6、on 2014-03-10. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.Up-to-date lists and bibliographical references concerning such national standards ma

7、y be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and n

8、otified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, German

9、y, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation

10、 Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 50153:2014 EBS EN 50153:2014EN 50153:2014 2 Con

11、tents Foreword . 4 Introduction . 5 1 Scope . 6 2 Normative references . 6 3 Terms, definitions and abbreviations . 7 3.1 Terms and definitions . 7 3.2 Abbreviations 10 4 Classification of voltage bands . 10 4.1 General principles . 10 4.2 Connections between circuits . 11 4.3 Exceptions 11 5 Protec

12、tive provisions against direct contact . 12 5.1 General . 12 5.2 Protection by insulation . 12 5.3 Protection by prevention of access . 12 5.4 Protection by the use of band I . 14 5.5 Warning labels 15 6 Protective provisions against indirect contact 15 6.1 General . 15 6.2 Protective bonding 15 6.3

13、 Disconnection of the supply 16 6.4 Main protective bonding 16 6.5 Clarifications and exceptions with reference to indirect contact . 18 6.6 Additional requirements Bearings 19 7 Power circuit . 19 7.1 General principles . 19 7.2 Power circuit insulated from the vehicle body or bogie . 20 7.3 Power

14、circuit using the vehicle body or bogie . 20 8 Additional requirements . 20 8.1 General . 20 8.2 Current collectors 20 8.3 Capacitors . 21 8.4 Plug and socket devices . 21 8.5 Special sources 22 Annex A (normative) Special national conditions . 23 Annex B (normative) List of items where contracting

15、parties shall co-operate . 24 Annex C (informative) Proposals for design of main protective connections . 25 C.1 General . 25 C.2 Example for main earth connections 26 C.3 Examples of technical specification for steel earthing wires. 27 Annex D (informative) Operate over 750 V DC third rail electrif

16、ied lines in Great Britain . 28 D.1 Introduction . 28 D.2 Bonding between rail vehicle main body to bogie . 28 D.3 Inter-vehicle bonding 28 BS EN 50153:2014 3 EN 50153:2014 Bibliography 29 Figure Figure C.1 Earthing wire . 26 Tables Table 1 Voltage bands 11 Table 2 Maximum impedance between each veh

17、icle body of a unit and protective conductor of the fixed installation 17 BS EN 50153:2014EN 50153:2014 4 Foreword This document (EN 50513:2014) has been prepared by CLC/SC 9XB “Electromechanical material on board rolling stock“ from CLC/TC 9X “Electrical and electronic applications for railways“. T

18、he following dates are fixed: latest date by which this document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2015-03-10 latest date by which the national standards conflicting with this document have to be withdrawn (dow) 2017-03-1

19、0 This document supersedes EN 50153:2002. EN 50153:2013 includes the following significant technical changes with respect to EN 50153:2002: the document now takes into account EN 50122-1:2011 and UIC leaflet 533:2011; other normative references and some definitions have been updated; Annex D has bee

20、n added, Annex C has been changed. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate giv

21、en to CENELEC by the European Commission and the European Free Trade Association. BS EN 50153:2014 5 EN 50153:2014 Introduction It is generally accepted that safety depends on human factors, based on the normal behaviour of the operators involved, as well as upon technical factors. For these reasons

22、, this European Standard, in several instances, leaves a choice to the contracting parties between two alternatives. These alternatives consist of either the provision of operating rules, regulations and procedures, or in the application of technical measures such as mechanical or electrical interlo

23、cking devices. A list of the cases for which the contracting parties (e.g. user and manufacturer) should reach agreement before signing the contract is included in Annex B. BS EN 50153:2014EN 50153:2014 6 1 Scope This European Standard defines requirements to be applied in the design and manufacture

24、 of electrical installations and equipment to be used on rolling stock to protect persons from electric shocks. This European Standard is applicable to rolling stock of rail transport systems, road transport systems, if they are powered by an external supply (e.g. trolley buses), magnetically levita

25、ted transport systems and to the electrical equipment installed in these systems. This European Standard does not apply to: mine railways in mines, crane installations, moving platforms and similar transport systems on rails, funicular railways, temporary constructions. 2 Normative references The fo

26、llowing documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 50122-1:20

27、111), Railway applications Fixed installations Electrical safety, earthing and the return circuit Part 1: Protective provisions against electric shock EN 50124-1, Railway applications Insulation coordination Part 1: Basic requirements Clearances and creepage distances for all electrical and electron

28、ic equipment EN 50388, Railway applications Power supply and rolling stock Technical criteria for the coordination between power supply (substation) and rolling stock to achieve interoperability HD 60364-4-41:2007, Low-voltage electrical installations Part 4-41: Protection for safety Protection agai

29、nst electric shock (IEC 60364-4-41:2005, modified) EN 60529, Degrees of protection provided by enclosures (IP Code) (IEC 60529) EN 61140, Protection against electric shock Common aspects for installation and equipment (IEC 61140) EN 61310-1, Safety of machinery Indication, marking and actuation Part

30、 1: Requirements for visual, acoustic and tactile signals (IEC 61310-1) IEC/TS 60479-1, Effects of current on human beings and livestock Part 1: General aspects 1) This document is currently impacted by the amendment EN 50122-1:2011/A1:2011. BS EN 50153:2014 7 EN 50153:2014 3 Terms, definitions and

31、abbreviations 3.1 Terms and definitions For the purposes of this document, the following terms and definitions apply. NOTE For more information relating to definitions of parts of the fixed installations, see EN 50122-1 from which these definitions are derived. 3.1.1 Definitions concerning persons 3

32、.1.1.1 (electrically) instructed person person adequately advised or supervised by electrically skilled persons to enable them to perceive risks and to avoid hazards electricity can create 3.1.1.2 ordinary person person who is neither a skilled person nor an (electrically) instructed person 3.1.1.3

33、skilled person person who can judge the work assigned to him and recognize possible dangers on the basis of their professional training, knowledge and experience and of their knowledge of the relevant requirements 3.1.2 Other definitions 3.1.2.1 closed electrical operating area room or location whic

34、h serves exclusively for the operation of electrical equipment and is kept secure by a means appropriate to the voltage and location Note 1 to entry: Access to such areas is permitted only to skilled persons and (electrically) instructed persons. Note 2 to entry: The definition of closed electrical

35、operating area can be suitable for underfloor or upperroof cabinets. Generally speaking, it is any location (inside or outside the car body) which is kept secured because of the voltage that can assumed to be present on the equipment inside it. Access to such areas is not allowed for ordinary person

36、s. 3.1.2.2 contact line conductor system for supplying electrical energy to rolling stock systems through current-collecting equipment 3.1.2.3 contact wire electric conductor of an overhead contact line with which the current collectors make contact 3.1.2.4 cut-off supply of electrical energy to liv

37、e parts is switched off BS EN 50153:2014EN 50153:2014 8 3.1.2.5 direct contact contact of persons or livestock with live parts 3.1.2.6 double insulation insulation comprising both basic insulation and supplementary insulation 3.1.2.7 earth conductive mass of the earth, whose electrical potential at

38、any point is conventionally taken as equal to zero 3.1.2.8 electrical operating area room or location which serves primarily for the operation of electrical equipment and is normally entered only by skilled persons or (electrically) instructed persons Note 1 to entry: Generally speaking, an electric

39、al operating area is any location (mainly inside the car body) where electrical equipments operate. The above is the main function of this area but not the only one. In fact, normally the area is not kept secured and protection against direct contact is achieved by other means (e.g. (electrically) p

40、rotective obstacles). 3.1.2.9 electric shock pathophysiological effect resulting from an electric current passing through a human or animal body 3.1.2.10 equipotential bond electrical connection putting various exposed conductive parts at a substantially equal potential Note 1 to entry: This can be

41、abbreviated to bond or bonding. 3.1.2.11 exposed conductive part conductive part of electrical equipment, which can be touched and which is not normally live, but can become live when basic insulation fails Note 1 to entry: A conductive part of electrical equipment which can only become live through

42、 contact with an exposed conductive part which has become live is not considered to be an exposed conductive part itself. 3.1.2.12 indirect contact electric contact of persons or livestock with exposed conductive parts which have become live under fault conditions 3.1.2.13 interlocking device device

43、 which makes the operation of a switching device dependent upon the position or operation of one or more other pieces of equipment BS EN 50153:2014 9 EN 50153:2014 3.1.2.14 interlock system system incorporating interlocking devices on access points to electrical equipment to prevent energisation of

44、accessible live parts 3.1.2.15 insulation/insulated supply of electrical energy to live parts is switched off and inadvertent reconnection prevented 3.1.2.16 live part conductor or conductive part intended to be energized in normal use Note 1 to entry: By convention this does not include the running

45、 rails and parts connected to them. 3.1.2.17 locking system system which comprises interlocking devices and physically prevents access to live parts unless the supply of electrical energy to the live parts has been isolated and made safe 3.1.2.18 mechanical locking use of a lock or bolted /screwed f

46、ixings to prevent access panels or doors being opened and require the use of a key or tool to remove 3.1.2.19 multi-stage insulation insulation which is employed in, e.g., roof or underframe-mounted traction resistors which are air-insulated 3.1.2.20 nominal voltage voltage by which an installation

47、or part of an installation is designated Note 1 to entry: The voltages are expressed by the value between poles, ripple-free for DC and by the r.m.s. value between phases for AC. Note 2 to entry: The actual voltage may differ from the nominal voltage by a quantity within permitted tolerances. For fu

48、rther information about traction systems supply voltages, see EN 50163. 3.1.2.21 PELV system electric system in which the voltage cannot exceed the value of extra-low voltage: under normal conditions and under single fault conditions, except earth faults in other electric circuits 3.1.2.22 (electric

49、ally) protective obstacle part preventing unintentional direct contact, but not preventing direct contact by deliberate action BS EN 50153:2014EN 50153:2014 10 3.1.2.23 power circuit circuit carrying the current of the machines and equipment, such as convertors and traction motors, which transmit the traction output 3.1.2.24 protection system means of ensuring safety against electrical hazards by means of system design as opposed to reliance on procedures 3.1.2.25 protective condu