EN 50291-2-2010 en Electrical apparatus for the detection of carbon monoxide in domestic premises - Part 2 Electrical apparatus for continuous operation in a fixed installation in .pdf

上传人:terrorscript155 文档编号:716949 上传时间:2019-01-04 格式:PDF 页数:18 大小:555.59KB
下载 相关 举报
EN 50291-2-2010 en Electrical apparatus for the detection of carbon monoxide in domestic premises - Part 2 Electrical apparatus for continuous operation in a fixed installation in .pdf_第1页
第1页 / 共18页
EN 50291-2-2010 en Electrical apparatus for the detection of carbon monoxide in domestic premises - Part 2 Electrical apparatus for continuous operation in a fixed installation in .pdf_第2页
第2页 / 共18页
EN 50291-2-2010 en Electrical apparatus for the detection of carbon monoxide in domestic premises - Part 2 Electrical apparatus for continuous operation in a fixed installation in .pdf_第3页
第3页 / 共18页
EN 50291-2-2010 en Electrical apparatus for the detection of carbon monoxide in domestic premises - Part 2 Electrical apparatus for continuous operation in a fixed installation in .pdf_第4页
第4页 / 共18页
EN 50291-2-2010 en Electrical apparatus for the detection of carbon monoxide in domestic premises - Part 2 Electrical apparatus for continuous operation in a fixed installation in .pdf_第5页
第5页 / 共18页
点击查看更多>>
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 50291-2:2010Electrical apparatus for the detection of carbon monoxide in domestic premisesPart 2: Electrical apparatus for continuous operation in a fixed installations in

2、recreational vehicles and similar premises including recreational craft Additional test methods and performance requirementsBS EN 50291-2:2010 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 50291-2:2010.The UK participation in its preparation was entrusted to T

3、echnicalCommittee GEL/31/19, Gas detectors.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. BSI 2011 ISBN 978 0

4、 580 63301 0 ICS 13.040.40; 13.120; 13.320; 97.030 Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 April 2011.Amendments issued since publicationDate T e x t

5、a f f e c t e dBS EN 50291-2:2010EUROPEAN STANDARD EN 50291-2 NORME EUROPENNE EUROPISCHE NORM April 2010 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 1

6、7, B - 1000 Brussels 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50291-2:2010 E ICS 13.320 English version Electrical apparatus for the detection of carbon monoxide in domestic premises - Part 2: Electrical apparatus for

7、continuous operation in a fixed installation in recreational vehicles and similar premises including recreational craft - Additional test methods and performance requirements Appareils lectriques pour la dtection du monoxyde de carbone dans les locaux usage domestiques - Partie 2: Appareils lectriqu

8、es en fonctionnement continu et en installation fixe dans les vhicules de loisir et locaux similaires incluant les embarcations de loisir - Mthodes dessai supplmentaires et exigences daptitude la fonction Elektrische Gerte fr die Detektion von Kohlenmonoxid in Wohnhusern - Teil 2: Ortsfeste elektris

9、che Gerte zum kontinuierlichen Betrieb in Freizeitfahrzeugen und hnlichen Umgebungen einschlielich Sportbooten -Ergnzende Prfverfahren und Anforderungen an das Betriebsverhalten This European Standard was approved by CENELEC on 2010-04-15. CENELEC members are bound to comply with the CEN/CENELEC Int

10、ernal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC

11、member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CEN

12、ELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania

13、, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 50291-2:2010EN 50291-2:2010 - 2 - Foreword This European Standard was prepared by the Technical Committee CENELEC TC 216, Gas detectors. The text of the draft was submitted to the formal vote and was approved by CENELEC a

14、s EN 50291-2 on 2010-04-15. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following dates were fixed: latest date by which the EN h

15、as to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2011-04-15 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2013-04-15 This Part 2 is to be used in conjunction with EN 50291-1:2010. This Par

16、t 2 supplements or modifies the corresponding clauses of EN 50291-1:2010. Where this Part 2 states “addition“, “modification“ or “replacement“, the relevant text of Part 1 is to be adapted accordingly. _ BS EN 50291-2:2010 3 EN 50291-2:2010 Contents 1 Scope 4 2 Normative references 4 3 Terms and def

17、initions .5 4 General requirements .6 4.1 General6 4.2 Construction 6 4.3 Indicators and alarms 6 4.4 Fault signals 7 4.5 Output signal .7 4.6 Software-controlled apparatus 7 4.7 Labelling and instructions 7 5 Test and performance requirements .9 5.1 General requirements for tests .9 5.2 Normal cond

18、itions for tests9 5.3 Test methods and performance requirements 9 6 Self-contained battery powered apparatus .13 Annexes .13 Bibliography 14 Figure Figure 1 Examples for marking .8 Tables Table 1 Electromagnetic emission Test conditions and performance requirements 11 Table 2 Electromagnetic immunit

19、y Test conditions and performance requirements 12 Table 3 Immunity for DC powered apparatus 13 BS EN 50291-2:2010EN 50291-2:2010 - 4 - 1 Scope This European Standard specifies general requirements for the construction, testing and performance of electrically operated carbon monoxide gas detection ap

20、paratus, designed for continuous operation in a fixed installation in recreational vehicles and similar premises including recreational craft. NOTE For caravan holiday homes EN 50291-1 applies. This European Standard specifies apparatus designed to operate in the event of an escape of carbon monoxid

21、e and to provide a visual and audible alarms only (Type B of EN 50291-1), or to provide visual and audible alarms and an executive action in the form of an output signal that can actuate directly or indirectly a shut-off device and/or other ancillary device (Type A of EN 50291-1). This European Stan

22、dard excludes apparatus for the detection of combustible gases, other than carbon monoxide itself (see EN 50194-1), for the detection of CO in industrial installations (see EN 45544-1, EN 45544-2 and EN 45544-3) or commercial premises, for CO measurement for smoke and fire detection. 2 Normative ref

23、erences The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 50270:2006 Electromagnetic compatibili

24、ty Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen EN 50291-1 Electrical apparatus for the detection of carbon monoxide in domestic premises Part 1: Test methods and performance requirements EN 60068-2-6 Environmental testing Part 2-6: Tests Test Fc

25、: Vibration (sinusoidal) (IEC 60068-2-6) EN 60068-2-7 Environmental testing Part 2-7: Tests Test Ga: Acceleration, steady state (IEC 60068-2-7) EN 60068-2-27 Environmental testing Part 2-27: Tests Test Ea and guidance: Shock (IEC 60068-2-27) EN 60529:1991 Degrees of protection provided by enclosures

26、 (IP Code) (IEC 60529:1989) EN 60721-3-6:1993 Classification of environmental conditions Part 3-6: Classification of groups of environmental parameters and their severities Ship environment (IEC 60721-3-6:1987 + A1:1991) EN 60945:2002 Maritime navigation and radiocommunication equipment and systems

27、General requirements Methods of testing and required test results (IEC 60945:2002) ISO 7637-1:2002 Road vehicles Electrical disturbances from conduction and coupling Part 1: Definitions and general considerations ISO 7637-2:2004 Road vehicles Electrical disturbances from conduction and coupling Part

28、 2: Electrical transient conduction along supply lines only BS EN 50291-2:2010 5 EN 50291-2:2010 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 50291-1 and the following apply. 3.1 recreational vehicle recreational vehicles considered by this Europea

29、n Standard include recreational craft, caravans and motor caravans NOTE Other motorised vehicles like trucks are known to have residential accommodation. They are not recreational vehicles but are considered as similar premises in respect of this European Standard. 3.2 recreational craft boat of a m

30、inimum length of 2,5 m and a maximum length of 24 m as specified in Directive 94/25/EC, which is intended for sports or leisure purposes NOTE For the purposes of this European Standard the word boat should be taken with the meaning recreational craft. 3.3 remote sensor sensor assembly that is mounte

31、d in a separate location from the control unit NOTE This definition should be read in conjunction with EN 50291-1, Definition 3.7. 3.4 control unit unit that may contain the power supply, signal processing, alarm circuits and indicators 3.5 vehicle supply powered apparatus apparatus designed to be p

32、owered by the vehicles electrical supply 3.6 caravan trailer leisure accommodation vehicle that meets requirements for construction and use of road vehicles EN 13878:2003 3.7 motor caravan self-propelled leisure accommodation vehicle that meets requirements for construction and use of road vehicles.

33、 It contains at least seats and table, sleeping accommodation which may be converted from the seats, cooking facilities, and storage facilities EN 13878:2003 BS EN 50291-2:2010EN 50291-2:2010 - 6 - 3.8 caravan holiday home transportable leisure accommodation vehicle that does not meet requirements f

34、or construction and use of road vehicles, that retains means for mobility and that is for temporary or seasonal occupation EN 13878:2003 4 General requirements 4.1 General This subclause of EN 50291-1 is applicable, with the following addition: In this European Standard there are requirements that c

35、over all apparatus. Additional application specific requirements apply to certain groups of recreational vehicles, such as boats. An apparatus which complies with the requirements for recreational craft will automatically comply with the requirements for motor caravans and caravans. An apparatus whi

36、ch complies with the requirements for motor caravans will automatically comply with the requirements for caravans. The apparatus are designed for continuous operation. NOTE 1 When the vehicle is not in use the apparatus may be switched off in order to save the vehicles power supply or the internal b

37、atteries. The apparatus may consist of one or more sensor(s) and a control unit. Sensors (integrated into the apparatus or remote) shall be designed to detect carbon monoxide. NOTE 2 Sensors or apparatus designed according EN 50291-1 may be used as apparatus or as component of it, if the additional

38、requirements of this European Standard are complied with. The apparatus shall reliably detect the presence of carbon monoxide in recreational vehicles under the stated application conditions, shall produce an alarm and Type A apparatus shall be able to initiate executive actions whenever the level e

39、xceeds the alarm set point. The apparatus, electrical assemblies and components shall comply with EN 50291-1, where applicable, with the construction requirements of 4.2 to 4.7 and the test and performance requirements of Clause 5. 4.2 Construction This subclause of EN 50291-1 is applicable, with th

40、e following addition: Each sensor shall be constructed of materials that will not corrode in the environment where it is designed for, e.g. in the presence of a salt-laden atmosphere as exists in a marine environment, or be affected by the gases and vapours that may be expected to be present in a re

41、creational craft. Adequate means shall be provided to mount the remote sensor(s), pointing vertically downwards, securely to the vehicles substructure. The control unit shall be constructed of materials that are suitable for use in the intended application e.g. in the cabin or below deck area of a r

42、ecreational craft. 4.3 Indicators and alarms This subclause of EN 50291-1 is applicable, with the following addition: 4.3.3 Addition: If more than one sensor is connected to a control unit, the control unit shall indicate the alarm condition of the different sensors individually. BS EN 50291-2:2010

43、7 EN 50291-2:2010 4.4 Fault signals This subclause of EN 50291-1 is replaced by: The apparatus shall provide a visual and audible fault signal in the event of interruption of communication between control unit and the remote sensor(s). The audible fault signal shall be clearly identified and differe

44、nt from a gas alarm. 4.5 Output signal This subclause of EN 50291-1 is applicable, with the following addition: The output signal of the apparatus shall operate under the same conditions as the visual and audible alarm. For triggering an output signal, there shall be no built-in delay. 4.6 Software-

45、controlled apparatus This subclause of EN 50291-1 is applicable. 4.7 Labelling and instructions 4.7.1 General This subclause of EN 50291-1 is applicable, with the following additions: The manufacturer shall declare for which of the following application(s) the device is approved: domestic premises;

46、caravans; motor caravans; boats. This shall be noted on a label on the device or fixed to the device with a more detailed explanation in the manual (see Figure 1). If one instruction manual is used for different types of devices it shall be explicitly noted which type is related to which of the abov

47、e mentioned applications. BS EN 50291-2:2010EN 50291-2:2010 - 8 - a) Appropriate for domestic premises (caravan holiday homes), caravans, motor caravans and boats b) Appropriate for domestic premises (caravan holiday homes), caravans and motor caravans Not appropriate for boats c) Appropriate for do

48、mestic premises (caravan holiday homes) and caravans Not appropriate for motor caravans and boats Figure 1 Examples for marking 4.7.2 Labelling This subclause of EN 50291-1 is applicable, with the following additions: The following is applicable to recreational craft only: i) The classification of t

49、he environmental condition as defined in EN 60721-3-6: remote sensor(s): 6K3/6B1/6S1/6M3; control unit: 6K2/6B1/6S1/6M3. 4.7.3 Cautions This subclause of EN 50291-1 is applicable. 4.7.4 Instruction booklet This subclause of EN 50291-1 is applicable, with the following additions: o) power consumption of mains operated apparatus; p) the correct operating voltage, fuse-rating, if any, and method of connection to the vehicles power system; q) a list of

展开阅读全文
相关资源
猜你喜欢
  • DIN EN ISO 11126-4-1998 Preparation of steel substrates before application of paints and related products - Specifications for non-metallic blast-cleaning abrasives - Part 4 Coal f.pdf DIN EN ISO 11126-4-1998 Preparation of steel substrates before application of paints and related products - Specifications for non-metallic blast-cleaning abrasives - Part 4 Coal f.pdf
  • DIN EN ISO 11126-5-1998 Preparation of steel substrates before application of paints and related products - Specifications for non-metallic blast-cleaning abrasives - Part 5 Nickel.pdf DIN EN ISO 11126-5-1998 Preparation of steel substrates before application of paints and related products - Specifications for non-metallic blast-cleaning abrasives - Part 5 Nickel.pdf
  • DIN EN ISO 11126-6-1997 Preparation of steel substrates before application of paints and related products - Specifications for non-metallic blast-cleaning abrasives - Part 6 Iron f.pdf DIN EN ISO 11126-6-1997 Preparation of steel substrates before application of paints and related products - Specifications for non-metallic blast-cleaning abrasives - Part 6 Iron f.pdf
  • DIN EN ISO 11126-7-1999 Preparation of steel substrates before application of paints and related products - Specifications for non-metallic blast-cleaning abrasives - Part 7 Fused .pdf DIN EN ISO 11126-7-1999 Preparation of steel substrates before application of paints and related products - Specifications for non-metallic blast-cleaning abrasives - Part 7 Fused .pdf
  • DIN EN ISO 11126-8-1997 Preparation of steel substrates before application of paints and related products - Specifications for non-metallic blast-cleaning abrasives - Part 8 Olivin.pdf DIN EN ISO 11126-8-1997 Preparation of steel substrates before application of paints and related products - Specifications for non-metallic blast-cleaning abrasives - Part 8 Olivin.pdf
  • DIN EN ISO 11126-9-2005 Preparation of steel substrates before application of paints and related products - Specifications for non-metallic blast-cleaning abrasives - Part 9 Stauro.pdf DIN EN ISO 11126-9-2005 Preparation of steel substrates before application of paints and related products - Specifications for non-metallic blast-cleaning abrasives - Part 9 Stauro.pdf
  • DIN EN ISO 11127-1-2012 Preparation of steel substrates before application of paints and related products - Test methods for non-metallic blast-cleaning abrasives - Part 1 Sampling.pdf DIN EN ISO 11127-1-2012 Preparation of steel substrates before application of paints and related products - Test methods for non-metallic blast-cleaning abrasives - Part 1 Sampling.pdf
  • DIN EN ISO 11127-2-2012 Preparation of steel substrates before application of paints and related products - Test methods for non-metallic blast-cleaning abrasives - Part 2 Determin.pdf DIN EN ISO 11127-2-2012 Preparation of steel substrates before application of paints and related products - Test methods for non-metallic blast-cleaning abrasives - Part 2 Determin.pdf
  • DIN EN ISO 11127-3-2012 Preparation of steel substrates before application of paints and related products - Test methods for non-metallic blast-cleaning abrasives - Part 3 Determin.pdf DIN EN ISO 11127-3-2012 Preparation of steel substrates before application of paints and related products - Test methods for non-metallic blast-cleaning abrasives - Part 3 Determin.pdf