EN 50377-14-1-2011 en Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 14-1 Cords with IEC 60793-2-50 si.pdf

上传人:赵齐羽 文档编号:717049 上传时间:2019-01-04 格式:PDF 页数:22 大小:936.54KB
下载 相关 举报
EN 50377-14-1-2011 en Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 14-1 Cords with IEC 60793-2-50 si.pdf_第1页
第1页 / 共22页
EN 50377-14-1-2011 en Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 14-1 Cords with IEC 60793-2-50 si.pdf_第2页
第2页 / 共22页
EN 50377-14-1-2011 en Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 14-1 Cords with IEC 60793-2-50 si.pdf_第3页
第3页 / 共22页
EN 50377-14-1-2011 en Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 14-1 Cords with IEC 60793-2-50 si.pdf_第4页
第4页 / 共22页
EN 50377-14-1-2011 en Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 14-1 Cords with IEC 60793-2-50 si.pdf_第5页
第5页 / 共22页
点击查看更多>>
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 50377-14-1:2011Connector sets and interconnect components to be used in optical fibre communication systems Product specifications Part 14-1: Cords with IEC 60793-2-50 sing

2、lemode category B1.1 and B1.3 fibre for category CBS EN 50377-14-1:2011 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 50377-14-1:2011.BSI, as a member of CEN, is obliged to publish EN 50377-14-1 as a British Standard. However, attention is drawn to the fact th

3、at the UK committee voted against its approval as a European Standard.The UK committee submitted a number of comments at Formal Vote, of principal concern were:that the purpose of the document needs to be clarified and reconsidered to make it a proper patchcord test regime or alter it so that it bec

4、omes a description document that calls up the connector and cable tests.in Annex A, the specification of a reference cord is particularly tight, which may cause unnecessary expense on testing. The published optical interface standard (BS EN 61755-1) ensures that there is always fibre to fibre contac

5、t at 50 um apex offset (given a set radius and undercut) and so the apex of a reference connector does not need to be tighter than this. Also the advice on connector cleaning is contrary to best practice. Connectors should be inspected before they are mated every time not every 50 matings.The UK com

6、mittee is pressing for the document to be taken into immediate maintenance and revised accordingly.The UK participation in its preparation was entrusted to Technical Committee GEL/86/2, Fibre optic interconnecting devices and passive components.A list of organizations represented on this committee c

7、an be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. BSI 2011ISBN 978 0 580 65411 4ICS 33.180.20Compliance with a British Standard cannot confer immunity from legal oblig

8、ations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 October 2011.Amendments issued since publicationDateText affectedBS EN 50377-14-1:2011EUROPEAN STANDARD EN 50377-14-1 NORME EUROPENNE EUROPISCHE NORM June 2011 CENELEC European Committ

9、ee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC member

10、s. Ref. No. EN 50377-14-1:2011 E ICS 33.180.20 English version Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 14-1: Cords with IEC 60793-2-50 singlemode category B1.1 and B1.3 fibre for category C Steckverbinderstze und Ve

11、rbindungsbauelemente fr Lichtwellenleiter-Datenbertragungssysteme - Produktnormen - Teil 14-1: Verbindungskabel fr Einmodenfasern der Kategorien B1.1 und B1.3 nach EN 60793 2 50 fr die Kategorie C This European Standard was approved by CENELEC on 2011-05-02. CENELEC members are bound to comply with

12、the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat

13、 or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the off

14、icial versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland

15、, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 50377-14-1:2011EN 50377-14-1:2011 2 Foreword This European Standard was prepared by the Technical Committee CENELEC TC 86BXA, Fibre optic interconnect, passive and connectorised components. The text of

16、the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as EN 50377-14-1 on 2011-05-02. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying a

17、ny or all such patent rights. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2012-05-02 latest date by which the national standards conflicting with the EN have to be withdra

18、wn (dow) 2014-05-02 This document includes the performance of the patch cord, as well as latest attenuation and return loss grades as specified in IEC. _ BS EN 50377-14-1:2011 3 EN 50377-14-1:2011 Connector sets and interconnect components to be used in optical fibre communication systems Product sp

19、ecifications Part 14-1: Cords with IEC 60793-2-50 singlemode category B1.1 and B1.3 fibre for category C Description Performance Fibre category: EN 60793-2-50 Types B1.1 and B1.3 Application: For use in EN category C (controlled environment) Cable type: EN 60794-2-50 Type simplex cables Attenuation

20、grades: (random mate) B: 0,12 dB mean 0,25 dB for 97 % of measurements C: 0,25 dB mean 0,50 dB for 97 % of measurements Return loss grade: (random mate) 1: 60 dB 2: 45 dB Related documents: EN 50377 series Connector sets and interconnect components to be used in optical fibre communication systems P

21、roduct specifications EN 60793-2-50 Optical fibres Part 2-50: Product specifications Sectional specification for class B single-mode fibres (IEC 60793-2-50) EN 60794-2-50 Optical fibre cables Part 2-50: Indoor cables Family specification for simplex and duplex cables for use in terminated cable asse

22、mblies (IEC 60794-2-50) EN 61300 series Fibre optic interconnecting devices and passive components Basic test and measurement procedures (IEC 61300 series) EN 61753-1 Fibre optic interconnecting devices and passive components performance standard Part 1: General and guidance for performance standard

23、s (IEC 61753-1) ETSI TS 100 671 Transmission and Multiplexing (TM); Passive optical components; Optical fibre connectors for single mode optical fibre communication systems; Common requirements and conformance testing Outline and maximum dimensions: Length BS EN 50377-14-1:2011EN 50377-14-1:2011 4 C

24、ontents 1 Scope 51.1 Product definition . 51.2 Intermateability of the plugs 51.3 Operating environment 51.4 Reliability . 51.5 Quality assurance 52 Normative references 63 Description . 63.1 Plug . 73.2 Cable . 73.3 Materials 73.4 Marking 74 Variants . 85 Dimensional requirements . 95.1 Outline dim

25、ensions 96 Tests . 96.1 Sample size . 96.2 Test and measurement methods 96.3 Test sequence . 96.4 Pass/fail criteria . 97 Test report 98 Product qualification requirements . 108.1 Dimensional and marking requirements 108.2 Optical performance requirements 108.3 Mechanical performance requirements .

26、128.4 Environmental performance requirements 14Annex A (informative) Reference connector details 15Annex B (normative) Tests, sample size and product sourcing requirements 16Annex C (normative) Cable bend (coiling) test procedure . 17Bibliography 18Figures Figure 1 Length of patch cord 9Figure C.1 C

27、able bend (coiling) test set-up . 17Tables Table 1 Ensured level of random attenuation 5Table 2 Connector references . 7Table 3 Optical performance requirements . 11Table 4 Mechanical performance requirements 12Table 5 Environmental performance requirements . 14Table B.1 Test, sample size and sourci

28、ng . 16BS EN 50377-14-1:2011 5 EN 50377-14-1:2011 1 Scope 1.1 Product definition This standard contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements that an assembled singlemode patch cord with cylindrical ferruled connectors shall meet in or

29、der for it to be categorised as an EN standard product. Since different variants and grades of performance are permitted, product marking details are given in 3.4 and Clause 4. 1.2 Intermateability of the plugs Although all products conforming to the requirements of this standard will intermate, the

30、 resulting level of random attenuation performance will only be ensured in accordance with Table 1. The intention is that this will be true irrespective of the manufacturing source(s) of the product. When intermating plug variants having different attenuation grades as specified in EN 61755-1, the r

31、esulting level of attenuation cannot be assured to be any better than the worst attenuation grade. The intermating of a grade C plug with a grade B plug will result in a grade C level of random attenuation performance. Table 1 Ensured level of random attenuation Plug variant / Attenuation grade Plug

32、 2 C B Plug 1 C C C B C B 1.3 Operating environment The tests selected combined with the severities and durations are representative of an EN 61753-1 category C environment. 1.4 Reliability Whilst the anticipated service life expectancy of the product in this environment is 20 years, compliance with

33、 this standard does not guarantee the reliability of the product. This should be predicted using a recognised reliability assessment programme. 1.5 Quality assurance Compliance with this standard does not guarantee the manufacturing consistency of the product. This should be maintained using a recog

34、nised quality assurance programme. BS EN 50377-14-1:2011EN 50377-14-1:2011 6 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the refer

35、enced document (including any amendments) applies. EN 50377 series Connector sets and interconnect components to be used in optical fibre communication systems Product specifications EN 60793-2-50 Optical fibres Part 2-50: Product specifications Sectional specification for class B single-mode fibres

36、 (IEC 60793-2-50) EN 60794-2-50 Optical fibre cables Part 2-50: Indoor cables Family specification for simplex and duplex cables for use in terminated cable assemblies (IEC 60794-2-50) EN 61300-2-4 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part

37、2-4: Tests Fibre/cable retention (IEC 61300-2-4) EN 61300-2-22 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-22: Tests Change of temperature (IEC 61300-2-22) EN 61300-2-42 Fibre optic interconnecting devices and passive components Basic test

38、and measurement procedures Part 2-42: Tests Static side load for connectors (IEC 61300-2-42) EN 61300-2-44 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-44: Tests Flexing of the strain relief of fibre optic devices (IEC 61300-2-44) EN 61300-3

39、-3 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-3: Examinations and measurements Active monitoring of changes in attenuation and return loss (IEC 61300-3-3) EN 61300-3-6 Fibre optic interconnecting devices and passive components Basic test a

40、nd measurement procedures Part 3-6: Examinations and measurements Return loss (IEC 61300-3-6) EN 61300-3-22 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-22: Examinations and measurements Ferrule compression force (IEC 61300-3-22) EN 61300-3-

41、28 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-28: Examinations and measurements Transient loss (IEC 61300-3-28) EN 61300-3-34 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-34: Exami

42、nations and measurements Attenuation of random mated connectors (IEC 61300-3-34) EN 61753-1 Fibre optic interconnecting devices and passive components performance standard Part 1: General and guidance for performance standards (IEC 61753-1) EN 61755-1 Fibre optic connector optical interfaces Part 1:

43、 Optical interfaces for single mode non-dispersion shifted fibres General and guidance (IEC 61755-1) 3 Description This document applies to both patch cords and work area cords. A patch cord is defined as a short length of cable with connector plugs assembled at both cable ends. Typical length (but

44、not limited to) is 1 m to 10 m, measured from tip to tip at the extremes. Patch cords are installed in mechanically protected locations (inside cabinets, distribution frames and enclosures). BS EN 50377-14-1:2011 7 EN 50377-14-1:2011 Work area cords are typically more ruggedized (larger diameter) an

45、d used in mechanically less protected locations. For the purpose of this document, both patch cords and work area cords are called patch cords. 3.1 Plug The plug features a cylindrical ferrule. It has a single male key that is used to limit and may be used to orientate, the relative rotation between

46、 mated connectors. A cover (dust cap) to protect the ferrule end faces when the connectors are in the unmated condition shall be provided. The plug shall meet the relevant product specification as listed in Table 2 (most common types are listed). Table 2 Connector references Connector Reference FC E

47、N 50377-2 series SC EN 50377-4 series SC-RJ EN 50377-6 series LC EN 50377-7 series LSH EN 50377-8 series MU EN 50377-10 series LX.5 EN 50377-13 series 3.2 Cable The cable shall meet the requirements of EN 60794-2-50. 3.3 Materials Materials which are not specified or which are not specifically descr

48、ibed are left to the discretion of the manufacturer. The plug materials shall meet the relevant requirements of the product specifications listed in Table 2. The cable materials shall meet the requirements of EN 60794-2-50. 3.4 Marking Marking of the product shall be in the following order of precedence: a) identification of the cable assembly manufacturer; b) manufacturing date code: year/week; c) manufacturers part number; d) variant identification number. Provision should be taken to avoid confusion between the original cable marking and the patch cord product information. BS EN 50377-1