EN 50393-2015 en Test methods and requirements for accessories for use on distribution cables of rated voltage 0 6 1 0 (1 2) kV.pdf

上传人:diecharacter305 文档编号:717099 上传时间:2019-01-04 格式:PDF 页数:42 大小:1.73MB
下载 相关 举报
EN 50393-2015 en Test methods and requirements for accessories for use on distribution cables of rated voltage 0 6 1 0 (1 2) kV.pdf_第1页
第1页 / 共42页
EN 50393-2015 en Test methods and requirements for accessories for use on distribution cables of rated voltage 0 6 1 0 (1 2) kV.pdf_第2页
第2页 / 共42页
EN 50393-2015 en Test methods and requirements for accessories for use on distribution cables of rated voltage 0 6 1 0 (1 2) kV.pdf_第3页
第3页 / 共42页
EN 50393-2015 en Test methods and requirements for accessories for use on distribution cables of rated voltage 0 6 1 0 (1 2) kV.pdf_第4页
第4页 / 共42页
EN 50393-2015 en Test methods and requirements for accessories for use on distribution cables of rated voltage 0 6 1 0 (1 2) kV.pdf_第5页
第5页 / 共42页
点击查看更多>>
资源描述

1、BSI Standards PublicationBS EN 50393:2015Test methods and requirementsfor accessories for use ondistribution cables of ratedvoltage 0,6/1,0 (1,2) kVBS EN 50393:2015 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 50393:2015.It supersedes BS EN 50393:2006, which

2、will be withdrawn on 8December, 2017.The UK participation in its preparation was entrusted to TechnicalCommittee GEL/20/11, Electric Cable accessories.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the

3、 necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2015. Published by BSI StandardsLimited 2015ISBN 978 0 580 78805 5ICS 29.120.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard

4、 was published under the authority of theStandards Policy and Strategy Committee on 28 February 2015.Amendments issued since publicationDate Text affectedBS EN 50393:2015EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 50393 February 2015 ICS 29.120.20 Supersedes EN 50393:2006English Version Tes

5、t methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV Mthodes et prescriptions dessai pour les accessoires de cbles de distribution de tension assigne 0,6/1,0 (1,2) kVPrfverfahren und Prfanforderungen fr die Garnituren von Verteilerkabeln mit ein

6、er Nennspannung von 0,6/1,0 (1,2) kV This European Standard was approved by CENELEC on 2014-12-08. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.U

7、p-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by

8、translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republ

9、ic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. Eu

10、ropean Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CENELEC All rights of exploitation in any form and by any means reserved worldw

11、ide for CENELEC Members. Ref. No. EN 50393:2015 EBS EN 50393:2015EN 50393:2015 2 Contents Foreword.4 1 Scope 5 2 Normative references 5 3 Terms and definitions 7 4 Components 8 4.1 Connectors 8 4.2 Materials . 9 5 Electrical characteristics . 9 5.1 Rated voltage 9 5.2 Current rating 9 6 Range of com

12、pliance 9 6.1 General . 9 6.2 Cables . 9 6.3 Connectors for joints . 10 6.4 Water immersion depth 11 6.5 Transition joints . 11 7 Type tests 11 7.1 General . 11 7.2 Test samples . 12 7.3 Sequence of tests . 12 8 Test methods . 15 8.1 General . 15 8.2 Impulse voltage withstand test at ambient tempera

13、ture 16 8.3 AC voltage withstand test 16 8.4 Insulation resistance test . 17 8.5 Impact test at ambient temperature . 17 8.6 Heating cycle test 18 8.7 Immersion test test installation . 19 8.8 Examination 19 8.9 Metallic screen short-circuit current withstand test 20 Annex A (informative) Determinat

14、ion of cable conductor temperature . 29 Annex B (informative) Identification of test cable 34 Annex C (informative) Identification of accessory test samples . 35 Annex D (informative) Identification of connector 36 Bibliography 37 Figures Figure 1 Example of envelope diameter . 11 Figure 2 Typical a

15、rrangement for the impact test for joints at ambient temperature 21 Figure 3 Typical arrangement for the heating cycle for joints in air . 22 Figure 4 Typical arrangement for the heating cycle test for joints in water 22 Figure 5 Typical arrangement for the heating cycle test for outdoor termination

16、s in water . 23 Figure 6 Method of connection of three-phase cables for the heating cycle test on a straight joint . 24 BS EN 50393:2015 3 EN 50393:2015 Figure 7 Method of connection of three-phase cables for the heating cycle test on a branch joint where the main cable conductor cross-section is gr

17、eater than 50 mm and the branch cable conductor cross-section is less than or equal to 50 mm . 25 Figure 8 Method of connection of three-phase main and branch cables of equal conductor cross-section for the heating cycle test on a branch joint 26 Figure 9 Method of connection of three-phase main and

18、 branch cables of unequal conductor cross-section for the heating cycle test on a branch joint 27 Figure 10 Typical heating cycle 28 Figure 11 Arrangement for the screen short-circuit test . 28 Figure A.1 Arrangement for the cable calibration test 30 Figure A.2 Variation of cwith stfor various heati

19、ng currents . 33 Tables Table 1 Summary of compliance with different cable insulations. 10 Table 2 Compliance extension for conductor connectors in joints . 10 Table 3 Test sequence for joints for solid extruded dielectric insulated cables and for transition joints between solid extruded dielectric

20、insulated cables and impregnated paper insulated cables . 12 Table 4 Test sequence for stop ends on solid extruded dielectric insulated cables 13 Table 5 Test sequence for outdoor terminations on solid extruded dielectric insulated cables . 13 Table 6 Number of test samples and conductor cross-secti

21、on: straight joints . 14 Table 7 Number of test samples and conductor cross-section: branch joints 14 Table 8 Number of test samples and conductor cross-section: stop ends 15 Table 9 Number of test samples and conductor cross-section: outdoor terminations . 15 BS EN 50393:2015EN 50393:2015 4 Forewor

22、d This document (EN 50393:2015) has been prepared by CLC/TC 20 “Electric cables”. The following dates are fixed: latest date by which this document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2015-12-08 latest date by which the nat

23、ional standards conflicting with this document have to be withdrawn (dow) 2017-12-08 This document supersedes EN 50393:2006. EN 50393:2015 includes the following significant technical changes with respect to EN 50393:2006: in Clause 1 Scope, the revised statement referring to existing approvals has

24、been inserted; in Clause 3 Definitions, definitions of stop end types have been revised to align with those of joints, and definitions of rigid and non-rigid joints have been removed; in Clause 6 Range of compliance, the numbers of joint and termination test samples have been increased (see also Tab

25、le 6), compliance restriction and extension with regard to different cable designs have been clarified, and compliance restrictions and extensions relating to conductor connectors have been inserted and shown in a new Table 2; in 7.3, Table 3, joints of Type II are subject to a new test involving 9

26、heating cycles in water without oversheath damage (see also 8.6.2); in 7.3, Tables 3, 4 and 5, the footnotes referring to examination of tested accessories have been removed; in Clause 8 Test methods, the AC voltage withstand test procedure has been simplified and clarified, references to rigid and

27、non-rigid joints have been removed, reference to the 9 cycle test for Type II joints (Table 3) has been inserted, and requirements relating to examination of tested joints have been simplified and references to specific technologies or materials have been removed; Annexes B, C and D have been added

28、to assist in full and accurate identification of test cable, accessories and connectors for inclusion in test reports. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifyin

29、g any or all such patent rights. BS EN 50393:2015 5 EN 50393:2015 1 Scope This European Standard details the performance requirements and the test methods for type testing of cable accessories for use with power distribution cables of rated voltage 0,6/1,0 (1,2) kV as defined in HD 603 or other rele

30、vant cable standards. Cable accessories covered by this European Standard include joints, stop ends and outdoor terminations for extruded solid dielectric insulated cables and transition joints between extruded solid dielectric insulated and impregnated paper insulated cables. Joints, stop ends and

31、outdoor terminations for impregnated paper insulated cables are not included. The service operating conditions of accessories should be compatible with the service operating conditions of cables on which they are to be installed. Accessories for special applications such as submarine, shipboard, exp

32、losive or seismic environments, or where specified fire performance characteristics are required, are not included. NOTE 1 This European Standard does not invalidate existing approvals of products achieved on the basis of national standards and specifications and/or the demonstration of satisfactory

33、 service performance. However, products approved according to such national standards or specifications cannot directly claim approval to this European standard. NOTE 2 It may be possible, subject to agreement between supplier and purchaser, and/or the relevant conformity assessment body, to demonst

34、rate that conformity to the earlier standard can be used to claim conformity to this European Standard, provided an assessment is made of any additional type testing that may need to be carried out. Any such additional testing that is part of a sequence of testing cannot be done separately. 2 Normat

35、ive references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) a

36、pplies. EN 61180-1:1994, High-voltage test techniques for low-voltage equipment Part 1: Definitions, test and procedure requirements (IEC 61180-1:1992) EN 61238-1, Compression and mechanical connectors for power cables for rated voltages up to 36 kV (Um= 42 kV) Part 1: Test methods and requirements

37、(IEC 61238-1) HD 603, Distribution cables of rated voltage 0,6/1 kV IEC 60050-461, International Electrotechnical Vocabulary Chapter 461: Electric cables 3 Terms and definitions For the purposes of this document, the terms and definitions given in IEC 60050-461 and the following apply. 3.1 joint acc

38、essory suitable for use in air or underground which makes a connection between two or more insulated power cables to form a continuous circuit BS EN 50393:2015EN 50393:2015 6 3.2 type I joint joint where impact withstand, impulse voltage withstand and metallic screen short-circuit current withstand

39、tests are not required 3.3 type II joint joint tested for impact withstand but not for impulse voltage withstand or metallic screen short-circuit current withstand 3.4 type III joint joint tested for impulse voltage withstand and metallic screen short-circuit current withstand but not for impact wit

40、hstand 3.5 transition joint accessory making a connection between cables having extruded solid dielectric insulation and impregnated paper insulation 3.6 stop end accessory providing a means of insulating the end of an energised cable 3.7 type I stop end stop end where impact withstand and impulse v

41、oltage withstand tests are not required 3.8 type II stop end stop end tested for impact withstand but not for impulse voltage withstand 3.9 type III stop end stop end tested for impulse voltage withstand but not for impact withstand 3.10 cable crutch position at which the laid up cores of a multicor

42、e cable separate into individual cores 3.11 outdoor termination termination intended for use where it is directly exposed to either solar radiation or weathering or both 3.12 type I termination termination where impulse voltage withstand is not required 3.13 type II termination termination tested fo

43、r impulse voltage withstand 3.14 connector device to connect cable conductors together BS EN 50393:2015 7 EN 50393:2015 3.15 compression (crimp) connector connector in which electrical connection is made by deformation or reshaping of the barrel around the cable conductor 3.16 mechanical connector c

44、onnector in which electrical connection is made by pressure applied using screws or bolts 3.17 multi-polar connector connector with the facility to connect conductors of two or more phases within one body and having electrical insulation between phases 3.18 IPC Insulation Piercing Connector connecto

45、r in which electrical contact with the conductor is made by metallic protrusions which pierce the insulation of the cable core SOURCE: IEV 461-11-08 3.19 product family group of products to be considered to have the same design criteria, the same insulation material characteristics, the same install

46、ation technology and the same connector technology 3.20 lug metallic device to connect a cable conductor to other electrical equipment SOURCE: IEV 461-17-01 4 Components 4.1 Connectors Conductor connectors used with joints and terminations shall comply with EN 61238-1, where applicable, or with anot

47、her relevant performance standard. Connectors are considered integral components of accessories and are subject to compliance extensions and limitations detailed in 6.3. Connectors for circumferential conductors comprising metal wires that are designed to carry neutral or induced current shall meet

48、the electrical requirements of EN 61238-1, where applicable, or those of another relevant performance standard. 4.2 Materials Component material characterization, either by fingerprinting or by type testing, is not a prerequisite for compliance with this performance standard. If material characteriz

49、ation by type testing is required for components included in the test sample kits, EN 60455-3-8 should be used for resins, and the relevant parts of EN 60684 and EN 62677 for respectively heat-shrink tubing or moulded components if applicable. For “fingerprinting” the appropriate part of HD 631 should be used. BS EN 50393:2015EN 50393:2015 8 5 Electrical characteristics 5.1 Rated voltage The rated voltage of the joints, stop ends and outdoor termination