1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 50525-3-41:2011Electric cables Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Part 3-41: Cables with special fire performance Single core
2、non-sheathed cables with halogen-free crosslinked insulation, and low emission of smokeBS EN 50525-3-41:2011 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN50525-3-41:2011. It partially supersedes BS7211:1998.The UK participation in its preparation was entrusted
3、 to TechnicalCommittee GEL/20/17, Electric Cables - Low voltage.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. B
4、SI 2011ISBN 978 0 580 64378 1ICS 29.060.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 September 2011.Amendments issued since publicationDate Text affectedBS
5、 EN 50525-3-41:2011 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN50525-3-41:2011. It partially supersedes BS7211:1998.The UK participation in its preparation was entrusted to TechnicalCommittee GEL/20/17, Electric Cables - Low voltage.A list of organizations r
6、epresented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. BSI 2011ISBN 978 0 580 64378 1ICS 29.060.20Compliance with a British Standard cannot confe
7、r immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 September 2011.Amendments issued since publicationDate Text affectedThis British Standard is the UK implementation of EN 50525-3-41:2011. In the UKnull the BS
8、EN 50525 series of standards nullontain nullomplenullsnullpersession details. The tanullle nullelonull nullest snullmmarinulles the relationship nulletnulleen these standards:Part 1 together with Supersedes2-null1 BS null3null-4:1nullnullnull2-41null 2-42 BS null00null: 200null2-11 nullin partnullnu
9、ll 2-12null 2-21 nullin partnullnull 2-null1 BS null500:20002-11 nullin partnullnull 2-21 nullin partnullnull 2-51 nullin partnullnull 2-null3null 3-21 BS nullnull1null:20012-31null 2-51 nullin partnull BS 6004:20003-41 BS 7211:19982-22null 2-null2null 2-null2null 3-11null 3-31 NoneNOTE All British
10、Standards will remain current until they are withdrawn on 31 December 2012. British Standards in bold are only partially supersedednull and new editions onull BS null00null and BS null211 will be introduced on 1 nullanuary 2013.National nullnnenull Nnull nullinformatinullenull nullinulles informatio
11、n on the orinullins and identinullnullation of partinullnulllar nullanullle tnullpes.BS EN 50525-3-41:2011EUROPEAN STANDARD EN 50525-3-41 NORME EUROPENNE EUROPISCHE NORM May 2011 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisch
12、es Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50525-3-41:2011 E ICS 29.060.20 Supersedes HD 22.9 S3:2007English version Electric
13、 cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke Cbles lectriques - Cbles dnergie basse tension de tension
14、 assigne au plus gale 450/750 V (U0/U) - Partie 3-41: Cbles performances spciales au feu - Conducteurs isols en matriau lastomre rticul sans halogne, faible dgagement de fume Kabel und Leitungen - Starkstromleitungen mit Nennspannungen bis 450/750 V (U0/U) - Teil 3-41: Starkstromleitungen mit verbes
15、sertem Verhalten im Brandfall - Halogenfreie, raucharme Ader- und Verdrahtungsleitungen mit vernetzter Isolierung This European Standard was approved by CENELEC on 2011-01-17. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
16、 European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions
17、 (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Aus
18、tria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United
19、Kingdom. BS EN 50525-3-41:2011EN 50525-3-41:2011 - 2 - Foreword This European Standard was prepared by the Technical Committee CENELEC TC 20, Electric cables. The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50525-3-41 on 2011-01-17. This document, which is on
20、e of a multipart series, supersedes HD 22.9 S3:2007. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following dates were fixed: late
21、st date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2012-01-17 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2014-01-17 _ BS EN 50525-3-41:2011- 3 - EN 50525-3-41:201
22、1 Contents Page 1 Scope 42 Normative references . 43 Terms and definitions . 54 Heat resistant cables (90 C) . 54.1 Cables for fixed wiring H07Z-U and H07Z-R . 54.2 Cables for fixed wiring H07Z-K . 54.3 Cables for internal wiring H05Z-U 64.4 Cables for internal wiring H05Z-K . 7Annex A (normative) T
23、ests for cables to EN 50525-3-41 8Annex B (normative) General data . 9Bibliography . 11Tables Table A.1 8Table B.1 Cables with rigid conductor (450/750 V) 9Table B.2 Cables with flexible conductor (450/750 V) 10Table B.3 Cables with rigid conductor (300/500 V) 10Table B.4 Cables with flexible conduc
24、tor (300/500 V) 10BS EN 50525-3-41:2011EN 50525-3-41:2011 - 4 - 1 Scope EN 50525-3-41 applies to non-sheathed single core cables insulated with halogen-free crosslinked compound and having low emission of smoke and corrosive gases when exposed to fire. NOTE 1 Low emission of smoke is checked in acco
25、rdance with EN 61034-2. Low emission of corrosive gases is checked as part of the check for absence of halogens (see Annex B of EN 50525-1). The cables are of rated voltages U0/U up to and including 450/750 V. NOTE 2 Cables rated 450/750 V may be used at 600/1 000 V when this cable is used in fixed
26、installations with mechanical protection, within switchgear and control gear - see HD 516. The cables are intended for fixed wiring applications. The maximum conductor operating temperature for each of the cables in this standard is 90 C. NOTE 3 HD 516 contains extensive guidance on the safe use of
27、cables in this standard. This EN 50525-3-41 should be read in conjunction with EN 50525-1, which specifies general requirements. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For
28、 undated references, the latest edition of the referenced document (including any amendments) applies. NOTE One or more references to the standards below are in respect of a specific sub-division of that standard, for instance a clause, a table, a class or a type. Cross-references to these standards
29、 are undated and, at all times, the latest version applies. EN 50363-5 Insulating, sheathing and covering materials for low voltage energy cables - Part 5: Halogen-free, cross-linked insulating compounds EN 50395 Electrical test methods for low voltage energy cables EN 50396 Non electrical test meth
30、ods for low voltage energy cables EN 50525-1 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements EN 60228 Conductors of insulated cables (IEC 60228) EN 60332-1-2 Tests on electric and optical fibre cables under fire condit
31、ions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame (IEC 60332-1-2) EN 60811-1-4 Insulating and sheathing materials of electric and optical cables - Common test methods - Part 1-4: General application - Tests at low temperatu
32、re (IEC 60811-1-4) EN 61034-2 Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements (IEC 61034-2) BS EN 50525-3-41:2011- 5 - EN 50525-3-41:2011 3 Terms and definitions For the purposes of this document the terms and definitions given in Cla
33、use 3 of EN 50525-1 apply. 4 Heat resistant cables (90 C) 4.1 Cables for fixed wiring H07Z-U and H07Z-R 4.1.1 Construction 4.1.1.1 Conductor The conductor shall be class 1 or class 2, according to EN 60228. 4.1.1.2 Sizes of cable The sizes of cable shall be: - class 1 1,5 mm2to 10 mm2;- class 2 1,5
34、mm2to 630 mm2.4.1.1.3 Insulation The insulation shall be a polyolefin cross-linked material of Type EI 5 to EN 50363-5 applied around the conductor. 4.1.1.4 Marking The cable shall be marked with the CENELEC code H07Z-U for cables with class 1 conductor, or H07Z-R for cables with class 2 conductor.
35、The marking shall comply with Clause 6 of EN 50525-1. 4.1.2 Requirements Each cable shall comply with the appropriate requirements given in EN 50525-1, and the particular requirements of this Part. Testing shall be in accordance with Annex A, and the relevant tests indicated in column 6. The dimensi
36、ons of the cables shall conform to Table B.1 for the relevant size. When tested in accordance with the method and procedure given in EN 61034-2, all sizes of cable shall exceed 60 % light transmittance throughout the test. 4.2 Cables for fixed wiring H07Z-K 4.2.1 Construction 4.2.1.1 Conductor The c
37、onductor shall be class 5, according to EN 60228. BS EN 50525-3-41:2011EN 50525-3-41:2011 - 6 - 4.2.1.2 Sizes of cable The sizes of cable shall be 1,5 mm2to 240 mm2. 4.2.1.3 Insulation The insulation shall be a polyolefin cross-linked material of Type EI 5 to EN 50363-5 applied around the conductor.
38、 4.2.1.4 Marking The cable shall be marked with the CENELEC code H07Z-K. The marking shall comply with Clause 6 of EN 50525-1. 4.2.2 Requirements Each cable shall comply with the appropriate requirements given in EN 50525-1, and the particular requirements of this Part. Testing shall be in accordanc
39、e with Annex A, and the relevant tests indicated in column 7. The dimensions of the cables shall conform to Table B.2 for the relevant size. When tested in accordance with the method and procedure given in EN 61034-2, all sizes of cable shall exceed 60 % light transmittance throughout the test. 4.3
40、Cables for internal wiring H05Z-U 4.3.1 Construction 4.3.1.1 Conductor The conductor shall be class 1, according to EN 60228. 4.3.1.2 Sizes of cable The sizes of cable shall be 0,5 mm2to 1 mm2. 4.3.1.3 Insulation The insulation shall be a polyolefin cross-linked material of Type EI 5 to EN 50363-5 a
41、pplied around the conductor. 4.3.1.4 Marking The cable shall be marked with the CENELEC code H05Z-U. The marking shall comply with Clause 6 of EN 50525-1. 4.3.2 Requirements Each cable shall comply with the appropriate requirements given in EN 50525-1, and the particular requirements of this Part. T
42、esting shall be in accordance with Annex A, and the relevant tests indicated in column 8. The dimensions of the cables shall conform to Table B.3 for the relevant size. BS EN 50525-3-41:2011- 7 - EN 50525-3-41:2011 When tested in accordance with the method and procedure given in EN 61034-2, all size
43、s of cable shall exceed 60 % light transmittance throughout the test. 4.4 Cables for internal wiring H05Z-K 4.4.1 Construction 4.4.1.1 Conductor The conductor shall be class 5, according to EN 60228. 4.4.1.2 Sizes of cable The sizes of cable shall be 0,5 mm2to 1 mm2. 4.4.1.3 Insulation The insulatio
44、n shall be a polyolefin cross-linked material of Type EI 5 to EN 50363-5 applied around the conductor. 4.4.1.4 Marking The cable shall be marked with the CENELEC code H05Z-K. The marking shall comply with Clause 6 of EN 50525-1. 4.4.2 Requirements Each cable shall comply with the appropriate require
45、ments given in EN 50525-1, and the particular requirements of this Part. Testing shall be in accordance with Annex A, and the relevant tests indicated in column 9. The dimensions of the cables shall conform to Table B.4 for the relevant size. When tested in accordance with the method and procedure g
46、iven in EN 61034-2, all sizes of cable shall exceed 60 % light transmittance throughout the test. BS EN 50525-3-41:2011EN 50525-3-41:2011 - 8 - Annex A (normative) Tests for cables to EN 50525-3-41 Table A.1 1 2 3 4 5 6 7 8 9 Ref No. Tests a Category of test Test method described in Applicability of
47、 test Subclause EN (Sub)clause 4.1 4.2 4.3 4.4 H07Z-UH07Z-RH07Z-kH05Z-UH05Z-K1 Electrical tests b 1.1 Resistance of conductors T, S 50395 5 X X X X 1.2.1 Voltage test at 2 500 V T, S 50395 6 X X - - 1.2.2 Voltage test at 2 000 V T, S 50395 6 - - X X 1.3 Insulation resistance at 90 C T 50395 8.1 X X
48、X X 1.4 Absence of faults in insulation R 50395 10 X X X X 2 Constructional and dimensional tests 2.1 Checking of compliance with constructional provisions T, S 50525-1 Inspection and manual tests X X X X 2.2 Measurement of thickness of insulation T, S 50396 4.1 X X X X 2.3 Measurement of overall di
49、ameter T, S 50396 4.4 X X X X 3 Insulation material tests T 50363-5 c - X X X X 4 Impact test at - 5 C T 60811-1-4 8.5 X X X X 5 Tests under fire conditions 5.1 Test on single vertical cable T 60332-1-2 - X X X X 5.2 Smoke emission T 61034-2 - X X X X 6 Assessment of halogens for all non-metallic materials T, S 50525-1 Annex B X X X X a The order given does not imply a sequence of testing. bParticular test conditions and requirements are given in Table 1 o