EN 50557-2011 en Requirements for automatic reclosing devices (ARDs) for circuit breakers- RCBOs-RCCBs for household and similar uses《家用和类似用途断路器(剩余电流动作断路器)的自动重合机构(ARD)要求》.pdf

上传人:fuellot230 文档编号:717277 上传时间:2019-01-04 格式:PDF 页数:54 大小:1.23MB
下载 相关 举报
EN 50557-2011 en Requirements for automatic reclosing devices (ARDs) for circuit breakers- RCBOs-RCCBs for household and similar uses《家用和类似用途断路器(剩余电流动作断路器)的自动重合机构(ARD)要求》.pdf_第1页
第1页 / 共54页
EN 50557-2011 en Requirements for automatic reclosing devices (ARDs) for circuit breakers- RCBOs-RCCBs for household and similar uses《家用和类似用途断路器(剩余电流动作断路器)的自动重合机构(ARD)要求》.pdf_第2页
第2页 / 共54页
EN 50557-2011 en Requirements for automatic reclosing devices (ARDs) for circuit breakers- RCBOs-RCCBs for household and similar uses《家用和类似用途断路器(剩余电流动作断路器)的自动重合机构(ARD)要求》.pdf_第3页
第3页 / 共54页
EN 50557-2011 en Requirements for automatic reclosing devices (ARDs) for circuit breakers- RCBOs-RCCBs for household and similar uses《家用和类似用途断路器(剩余电流动作断路器)的自动重合机构(ARD)要求》.pdf_第4页
第4页 / 共54页
EN 50557-2011 en Requirements for automatic reclosing devices (ARDs) for circuit breakers- RCBOs-RCCBs for household and similar uses《家用和类似用途断路器(剩余电流动作断路器)的自动重合机构(ARD)要求》.pdf_第5页
第5页 / 共54页
点击查看更多>>
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 50557:2011Requirements for automaticreclosing devices (ARDs) forcircuit breakers-RCBOs-RCCBsfor household and similar usesBS EN 50557:2011 BRITISH STANDARDNational foreword

2、This British Standard is the UK implementation of EN 50557:2011.The UK participation in its preparation was entrusted to TechnicalCommittee PEL/23/1, Circuit breakers and similar equipment forhousehold use.A list of organizations represented on this committee can beobtained on request to its secreta

3、ry.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2012ISBN 978 0 580 71224 1ICS 29.120.50Compliance with a British Standard cannot confer immunity fromlegal obligations.This B

4、ritish Standard was published under the authority of theStandards Policy and Strategy Committee on 31 January 2012.Amendments issued since publicationDate Text affectedBS EN 50557:2011EUROPEAN STANDARD EN 50557 NORME EUROPENNE EUROPISCHE NORM December 2011 CENELEC European Committee for Electrotechn

5、ical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 5055

6、7:2011 E ICS 29.120.50 English version Requirements for automatic reclosing devices (ARDs) for circuit breakers-RCBOs-RCCBs for household and similar uses Prescriptions pour les dispositifs refermeture automatique (DRA) pour disjoncteurs, ID et DD, pour usages domestiques et analogues Automatisch wi

7、edereinschaltende Einrichtungen fr Leitungsschutzschalter sowie Fehlerstrom-Schutzschalter mit und ohne eingebautem berstromschutz (RCBOs und RCCBs) fr Hausinstallationen und fr hnliche Anwendungen (ARDs) This European Standard was approved by CENELEC on 2011-07-19. CENELEC members are bound to comp

8、ly with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC

9、 Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre ha

10、s the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the

11、 Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 50557:2011EN 50557:2011 2 Contents Foreword . 5 Introduction . 61 Scope . 62 Normative references . 63 Terms and definitions . 84 Classification . 104.1 According to the meth

12、od of construction 104.2 According to the MPD . 104.3 According to the type of assessment means 104.4 According to the safety means during the assessment 114.5 According to the range of ambient air temperature (only for ARD according to 4.2.2 and 4.2.3) . 114.6 According to the connection to FE 114.

13、7 According to maximum number of reclosing operations 114.8 According to mechanical interlock between MPD operating means and ARD enabling/disabling system . 115 Characteristics 115.1 Summary of characteristics 115.2 Rated quantities 126 Marking and other product information . 136.1 Standard marking

14、 . 136.2 Instructions for assembly and operation . 147 Standard conditions for operation in service 157.1 General . 157.2 Conditions of installation . 157.3 Pollution degree 158 Requirements for construction and operation 158.1 Mechanical design 158.2 Protection against electric shock 198.3 Dielectr

15、ic properties and isolating capability . 198.4 Temperature rise 208.5 Mechanical and electrical endurance . 208.6 Performance at short-circuit currents . 208.7 Resistance to mechanical shock and impact 208.8 Resistance to heat 208.9 Resistance to abnormal heat and to fire . 208.10 Behaviour at low a

16、mbient air temperature 218.11 Operating characteristic 218.12 Assessment means for ARD according to 4.3.2 . 228.13 Safety in blocked condition . 238.14 Test device 238.15 Ageing . 238.16 Electromagnetic compatibility (EMC) 239 Tests . 239.1 General . 239.2 Test condition . 239.3 Measurement of the r

17、eclosing time after the tripping of the MPD 24BS EN 50557:2011 3 EN 50557:2011 9.4 Test of indelibility of marking 249.5 Verification of the non influence of the ARD on the correct operation of the MPD 249.6 Tests of creepage distances and clearances for electronic circuits (abnormal conditions) . 2

18、69.7 Requirements for capacitors and specific resistors and inductors used in electronic circuits 289.8 Test of reliability of screws, current-carrying parts and connections 289.9 Test of reliability of terminals for external conductors 299.10 Verification of protection against electric shock 299.11

19、 Test of dielectric properties and isolating capability . 299.12 Temperature rise 309.13 Verification of the mechanical and electrical endurance Verification of the reclosing system of the ARD 309.14 Short-circuit test 309.15 Resistance to mechanical shock and impact 319.16 Test of resistance to hea

20、t . 319.17 Resistance to abnormal heat and to fire . 329.18 Verification of the correct operation at low ambient air temperatures for RCCBs for use at temperatures between -25 C and +40 C . 329.19 Verification of the operating characteristics 329.20 Verification of the safety during the assessment 3

21、39.21 Verification of the operation of the test device at the limits of rated voltage 349.22 Verification of ageing 349.23 Electromagnetic compatibility . 35Annex A (informative) Classification of ARDs according to 4.3.1 . 43Annex B (informative) Classification of ARDs according to 4.3.2.1 a) and/or

22、 4.3.2.2 a) 44Annex C (informative) Classification of ARDs according to 4.3.2.1 b) and/or 4.3.2.2 b) . 45Annex D (normative) Number of samples for full test procedure 46Annex E (normative) Test sequences . 47Annex F (informative) A-deviations . 48Annex ZZ (informative) Coverage of Essential Requirem

23、ents of EC Directives. 49Bibliography 50Figures Figure 1 Minimum creepage distances and clearances measured in millimetres 37Figure 2 Minimum creepage distances and clearances as a function of peak value of operating voltage . 38Figure 3 Verification of the reclosing subordinated to the measurements

24、 of the resistance to earth for ARD without functional earthing (9.19.1 a) 9.19. 1 b) 9.20.2) 39Figure 4 Verification of the reclosing subordinated to the measurements of the resistance to earth for ARD with functional earthing (9.19.1 a) 9.19. 1 b) 9.20.2) . 40Figure 5 Verification of the reclosing

25、 subordinated to the measurements of the resistance between live parts (9.19.2 a) 9.19.2 b) 41Figure 6 Test circuit for the verification of the maximum current in FE under normal condition 42Figure A.1 Classification of ARDs according to 4.3.1 . 43Figure B.1 Classification of ARDs according to 4.3.2

26、.1 a) and/or 4.3.2.2 a) 44Figure C.1 Classification of ARDs according to 4.3.2.1 b) and/or 4.3.2.2 b) 45BS EN 50557:2011EN 50557:2011 4 Tables Table 1 Minimum admissible Rdvalues 12Table 2 Minimum clearances and creepage distances 18Table 3 Behaviour of the ARD in enable condition . 22Table 4 Maximu

27、m permissible temperatures under abnormal conditions 27Table 5 Low frequency immunity test conditions 35Table 6 High-frequency immunity test conditions . 36Table 7 Test conditions for electrostatic discharges 36Table D.1 Number of samples for full test procedure . 46Table D.2 Additional tests for AR

28、D already fully tested together with one kind of MPD 46Table E.1 Test sequences 47BS EN 50557:2011 5 EN 50557:2011 Foreword This document (EN 50557:2011) has been prepared by CLC/TC 23E “Circuit breakers and similar devices for household and similar applications“. The following dates are fixed: late

29、st date by which this document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2012-07-19 latest date by which the national standards conflicting with this document have to be withdrawn (dow) 2014-07-19 Attention is drawn to the possib

30、ility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trad

31、e Association, and supports essential requirements of EU Directive(s). For the relationship with EU Directive(s) see informative Annex ZZ, which is an integral part of this document. _ BS EN 50557:2011EN 50557:2011 6 Introduction Automatic Reclosing Devices are intended to reclose circuit-breakers-R

32、CBOs-RCCBs after tripping in order to re-establish continuity of service. 1 Scope This European Standard applies to Automatic Reclosing Devices (hereinafter referred to as “ARD”) for household and similar uses, for rated voltage not exceeding 440 V a.c. intended to be used in combination with circui

33、t-breakers and/or RCCBs and/or RCBOs, and designed either for factory assembly or for assembly on site. These devices are intended to reclose main protective devices (hereinafter referred to as “MPD”) such as circuit-breakers complying to EN 60898-1 and/or EN 60898-2, RCCBs complying to EN 61008-1 a

34、nd RCBOs complying to EN 61009-1 after tripping of those devices in order to re-establish continuity of service. In detail, this European Standard applies to the following types of ARD: ARD with assessment means, reclosing only if both the prospective line current and the prospective earth-fault cur

35、rent do not exceed given values; ARD with assessment means, reclosing only if the prospective line current does not exceed a given value; ARD with assessment means, reclosing only if the prospective earth-fault current does not exceed a given value; ARD that reclose without any assessment. NOTE 1 Th

36、e assessment cannot substitute the verifications required by HD 60364-6:2007. NOTE 2 The requirements and tests for the assessment function in IT systems are under consideration. This European Standard does not apply to ARDs with multiple settings adjustable by means accessible to the user in normal

37、 service. This European Standard states: the terms and definitions used for ARD (Clause 3); the classification of ARD (Clause 4); the characteristics of ARD (Clause 5); the preferred values of the operating and influencing quantities (Clause 5); the marking and information to be provided for ARD (Cl

38、ause 6); the standard conditions for installation and operation in service (Clause 7); the requirements for construction and operation (Clause 8); the list of minimum requirements to be tested (Clause 9). 2 Normative references The following referenced documents are indispensable for the application

39、 of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 55014-1:2006 + A1:2009, Electromagnetic compatibility Requirements for household appliances, electric tools and simila

40、r apparatus Part 1: Emission (CISPR 14-1:2005 + A1:2008) EN 60065:2002 + A1:2006 + corr. Aug. 2007 + A11:2008 + A2:2010, Audio, video and similar electronic apparatus Safety requirements (IEC 60065:2001, mod. + A1:2005, mod. + A2:2010, mod.) BS EN 50557:2011 7 EN 50557:2011 EN 60112:2003 + A1:2009,

41、Method for the determination of the proof and the comparative tracking indices of solid insulating materials (IEC 60112:2003 + A1:2009) EN 60384-14 series, Fixed capacitors for use in electronic equipment (IEC 60384 series) EN 60384-14:2005, Fixed capacitors for use in electronic equipment Part 14:

42、Sectional specification Fixed capacitors for electromagnetic interference suppression and connection to the supply mains (IEC 60384-14:2005) EN 60664-1:2007, Insulation coordination for equipment within low-voltage systems Part 1: Principles requirements and tests (IEC 60664-1:2007) EN 60664-3:2003

43、+ A1:2010, Insulation coordination for equipment within low-voltage systems Part 3: Use of coating, potting or moulding for protection against pollution (IEC 60664-3:2003 + A1:2010 + corr. Nov. 2010) EN 60898-1:2003 + corr. Feb. 2004 + A1:2004 + A11:2005 + A12:2008, Electrical accessories Circuit-br

44、eakers for overcurrent protection for household and similar installations Part 1: Circuit-breakers for a.c. operation (IEC 60898-1:2002, mod. + A1:2002, mod.) EN 60898-2:2006, Electrical accessories Circuit-breakers for overcurrent protection for household and similar installations Part 2: Circuit-b

45、reakers for a.c. and d.c. operation (IEC 60898-2:2000, mod. + A1:2003, mod.) EN 60947-5-1:2004 + corr. Jul. 2005 + A1:2009, Low-voltage switchgear and controlgear Part 5-1: Control circuit devices and switching elements Electromechanical control circuit devices (IEC 60947-5-1:2003 + A1:2009) EN 6095

46、0-1:2006 + A11:2009 + A1:2010, Information technology equipment Safety Part 1: General requirements (IEC 60950-1:2005, mod. + A1:2009, mod.) EN 61008-1:2004 + A11:2007 + A12:2009, Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs

47、) Part 1: General rules (IEC 61008-1:1996, mod. + A1:2002, mod.) EN 61009-1:2004 + A11:2008 + A12:2009 + A13:2009, Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) Part 1: General rules (IEC 61009-1:1996, mod. + A1:2002, mod. + co

48、rr. May 2003) EN 61000-4-2:2009, Electromagnetic compatibility (EMC) Part 4-2: Testing and measurement techniques Electrostatic discharge immunity test (IEC 61000-4-2:2008) EN 61000-4-3:2006 + A1:2008 + A2:2010, Electromagnetic compatibility (EMC) Part 4-3: Testing and measurement techniques Radiated, radio-frequency, electromagnetic field immunity test (IEC 61000-4-3:2006 + A1:2007 + A2:2010) EN 61000-4-4:2004 + A1:

展开阅读全文
相关资源
猜你喜欢
  • BS ISO 12619-6-2017 Road vehicles Compressed gaseous hydrogen (CGH2) and hydrogen natural gas blend fuel system components Automatic valve《道路车辆 压缩气态氢(CGH2)和氢 天然气混合燃料系统部件 自动阀》.pdf BS ISO 12619-6-2017 Road vehicles Compressed gaseous hydrogen (CGH2) and hydrogen natural gas blend fuel system components Automatic valve《道路车辆 压缩气态氢(CGH2)和氢 天然气混合燃料系统部件 自动阀》.pdf
  • BS ISO 12619-8-2017 Road vehicles Compressed gaseous hydrogen (CGH2) and hydrogen natural gas blends fuel system components Pressure indicator《公路车辆 压缩气态氢(CGH 2)和氢 天然气混合燃料系统部件 压力指示器.pdf BS ISO 12619-8-2017 Road vehicles Compressed gaseous hydrogen (CGH2) and hydrogen natural gas blends fuel system components Pressure indicator《公路车辆 压缩气态氢(CGH 2)和氢 天然气混合燃料系统部件 压力指示器.pdf
  • BS ISO 12619-9-2017 Road vehicles Compressed gaseous hydrogen (CGH2) and hydrogen natural gas blends fuel system components Pressure relief valve (PRV)《公路车辆 压缩气态氢(CGH 2)和氢 天然气混合燃料系.pdf BS ISO 12619-9-2017 Road vehicles Compressed gaseous hydrogen (CGH2) and hydrogen natural gas blends fuel system components Pressure relief valve (PRV)《公路车辆 压缩气态氢(CGH 2)和氢 天然气混合燃料系.pdf
  • BS ISO 12632-2015 Graphic technology Ink paper and labels Requirements on hot alkali penetration and resistance《印刷技术 油墨 纸张和标签 热碱渗透和阻力要求》.pdf BS ISO 12632-2015 Graphic technology Ink paper and labels Requirements on hot alkali penetration and resistance《印刷技术 油墨 纸张和标签 热碱渗透和阻力要求》.pdf
  • BS ISO 12637-1-2006 Graphic technology - Vocabulary - Fundamental terms《印刷技术 词汇 基本术语》.pdf BS ISO 12637-1-2006 Graphic technology - Vocabulary - Fundamental terms《印刷技术 词汇 基本术语》.pdf
  • BS ISO 12637-3-2009 Graphic technology - Vocabulary - Printing terms《图形技术 词汇表 印刷术语》.pdf BS ISO 12637-3-2009 Graphic technology - Vocabulary - Printing terms《图形技术 词汇表 印刷术语》.pdf
  • BS ISO 12637-4-2008 Graphic technology - Vocabulary - Postpress terms《图形技术 词汇 印刷术语》.pdf BS ISO 12637-4-2008 Graphic technology - Vocabulary - Postpress terms《图形技术 词汇 印刷术语》.pdf
  • BS ISO 12640-2-2004 Graphic technology - Prepress digital data exchange - XYZ sRGB encoded standard colour image data (XYZ SCID)《印刷技术 印前数字数据交换 XYZ sRGB编码的标准彩色图像数据(XYZ SCID)》.pdf BS ISO 12640-2-2004 Graphic technology - Prepress digital data exchange - XYZ sRGB encoded standard colour image data (XYZ SCID)《印刷技术 印前数字数据交换 XYZ sRGB编码的标准彩色图像数据(XYZ SCID)》.pdf
  • BS ISO 12640-3-2007 Graphic technology Prepress digital data exchange CIELAB standard colour image data (CIELAB SCID)《图形技术 预印数字数据交换 CIELAB标准颜色图象数据(CIELAB SCID)》.pdf BS ISO 12640-3-2007 Graphic technology Prepress digital data exchange CIELAB standard colour image data (CIELAB SCID)《图形技术 预印数字数据交换 CIELAB标准颜色图象数据(CIELAB SCID)》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1