EN 60192-2001 en Low Pressure Sodium Vapour Lamps - Performance Specifications《低压钠灯 性能规格 IEC 60192-2001》.pdf

上传人:appealoxygen216 文档编号:717699 上传时间:2019-01-04 格式:PDF 页数:46 大小:918.08KB
下载 相关 举报
EN 60192-2001 en Low Pressure Sodium Vapour Lamps - Performance Specifications《低压钠灯 性能规格 IEC 60192-2001》.pdf_第1页
第1页 / 共46页
EN 60192-2001 en Low Pressure Sodium Vapour Lamps - Performance Specifications《低压钠灯 性能规格 IEC 60192-2001》.pdf_第2页
第2页 / 共46页
EN 60192-2001 en Low Pressure Sodium Vapour Lamps - Performance Specifications《低压钠灯 性能规格 IEC 60192-2001》.pdf_第3页
第3页 / 共46页
EN 60192-2001 en Low Pressure Sodium Vapour Lamps - Performance Specifications《低压钠灯 性能规格 IEC 60192-2001》.pdf_第4页
第4页 / 共46页
EN 60192-2001 en Low Pressure Sodium Vapour Lamps - Performance Specifications《低压钠灯 性能规格 IEC 60192-2001》.pdf_第5页
第5页 / 共46页
点击查看更多>>
资源描述

1、BRITISH STANDARD Low pressure sodium vapour lamps - Performance specification The European Standard EN 60192:2001 has the status of a British Standard ICs 29.140.20 BS EN 60192:2001 IEC 60192:2001 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BS EN 60192:2001 Amd. No. Nation

2、al foreword Date Comments This British Standard is the official English language version of EN 60192:2001. It is identical with IEC 60192:2001. It supersedes BS EN 60192:1993 which is withdrawn. The UK participation in its preparation was entrusted by Technical Committee CPIJ34, Lamps and related eq

3、uipment, to Subcommittee CPL13411, Electric lamps, which has the responsibility to: - - aid enquirers to understand the text; present to the responsible internationallEuropean committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related

4、international and European developments and promulgate them in the UK. - A list of organizations represented on this subcommittee can be obtained on request to its secretary. From 1 January 1997, all IEC publications have the number 60000 added to the old number. For instance, IEC 27-1 has been renu

5、mbered as IEC 60027-1. For a period of time during the change over from one numbering system to the other, publications may contain identifiers from both systems. Cross-references The British Standards which implement international or European publications referred to in this document may be found i

6、n the BSI Standards Catalogue under the section entitled ?International Standards Correspondence Index?, or by using the ?Find? facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards ar

7、e responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. This British Standard, having been prepared under the direction of the Electrotechnical Sector Policy and Strategy Committee, was published under the authority o

8、f the Standards Policy and Strategy Committee on 25 September 2001 Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 14, lamp data sheets, the annex ZA page and a back cover. The BSI copyright notice displayed in this document indicates when

9、 the document was last issued. Amendments issued since publication P BI 25 September 2001 ISBN O 580 38483 7 EUROPEAN STANDARD EN 60192 NORME EUROPENNE EUROPISCHE NORM Julv 2001 ICs 29.140.30 Supersedes EN 60192:1993 + A4:1995 +A5:1995 English version Low pressure sodium vapour lamps - Performance s

10、pecifications (IEC 60192:2001) Lampes vapeur de sodium basse pression - Prescriptions de performance (CE1 601 92:ZOOl) Natriumdampf-Niederdrucklampen - Anforderungen an die Arbeitsweise (IEC 60192:2001) This European Standard was approved by CENELEC on 2001-07-01. CENELEC members are bound to comply

11、 with the CEWCENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secret

12、ariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibiliiy of a CENELEC member into its own language and notified to the Central Secretariat has the same status as th

13、e official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netheriands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Commit

14、tee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels O 2001 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC

15、 members. Ref. No. EN 60192:2001 E Page 2 EN 60192:2001 Foreword The text of document 34A953/FDIS, future edition 3 of IEC 60192, prepared by SC 34A, Lamps, of IEC TC 34, Lamps and related equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60192 on 2001-07-01

16、. This European Standard supersedes EN 60192:1993 + A4:1995 + A5:1995. The following dates were fixed: - latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement - latest date by which the national standards conflicting wi

17、th the EN have to be withdrawn (dop) 2002-04-01 (dow) 2004-07-01 Annexes designated “normative“ are part of the body of the standard. Annexes designated “informative“ are given for information only. In this standard, annexes A, B and ZA are normative and annex C is informative. Annex ZA has been add

18、ed by CENELEC. Endorsement notice The text of the International Standard IEC 60192:2001 was approved by CENELEC as a European Standard without any modification. Page 3 EN 60192:2001 CONTENTS 1 General 4 1.1 Scope . 4 1.2 Normative references 4 1.3 Definitions 5 1.4 Lamp requirements . 6 1.4.1 Genera

19、l . 6 1.4.2 Dimensions . 6 1.4.3 Caps . 6 1.4.4 Starting characteristics 6 1.4.5 Electrical characteristics 6 1.4.6 Photometric characteristics . 6 Information for luminaire design 6 1.5 Annex A (normative) Method of measuring starting characteristics 7 Annex B (normative) Method of measuring electr

20、ical and photometric characteristics 8 Annex C (informative) Information for luminaire design 10 Bibliography 11 2 Data Sheets 13 2.1 2.2 General principles of numbering sheets 13 Lists of data sheets 13 2.2.1 List of lamp data sheets . 13 2.2.2 List of maximum lamp outline sheets 13 Page 4 EN 60192

21、:2001 LOW-PRESSURE SODIUM VAPOUR LAMPS - PERFORMANCE SPECIFICATIONS I General 1.1 Scope This standard specifies the performance requirements for low-pressure sodium vapour lamps for general lighting purposes. For some of the requirements given in this standard, reference is made to “the relevant lam

22、p data sheet“. For some lamps these data sheets are contained in this standard. For other lamps, falling under the scope of this standard, the relevant data are supplied by the lamp manufacturer or responsible vendor. The requirements of this standard relate only to type testing. NOTE The requiremen

23、ts and tolerances permitted by this standard correspond to testing of a type test sample submitted by the manufacturer for that purpose. In principle this type test sample should consist of units having characteristics typical of the manufacturers production and being as close to the production cent

24、re point values as possible. It may be expected with the tolerances given in the standard that products manufactured in accordance with the type test sample will comply with the standard for the majority of production. Due to the production spread however, it is inevitable that there will sometimes

25、be products outside the specified tolerances. For guidance on sampling plans and procedures for inspection by attributes, see IEC 60410. 1.2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this International St

26、andard. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. However, parties to agreements based on this International Standard are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated

27、 below. For undated references, the latest edition of the normative document referred to applies. Members of IEC and IS0 maintain registers of currently valid International Standards. IEC 60050(845), International Electrotechnical Vocabulary (IEV) - Chapter 845: Lighting IEC 60061-1, Lamp caps and h

28、olders together with gauges for the control of interchangeability and safety - Pari I: Lamp caps IEC 60923, Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - Performance requirements IEC 62035, Discharge lamps (excluding fluorescent lamps) - Safety specific

29、ations Page 5 EN 60192:2001 1.3 Definitions For the purposes of this International Standard, the following terms and definitions, as well as others given in IEC 60050(845), apply: 1.3.1 low pressure sodium (vapour) lamp discharge lamp in which the light is produced by radiation from sodium vapour op

30、erating at a partial pressure of 0,l to 13 pascal IEV 845-07-241 I .3.2 nominal value approximate quantity value used to designate or identify a lamp 1.3.3 rated value quantity value for a characteristic of a lamp for specified operating conditions. The value and the conditions are specified in this

31、 standard, or assigned by the manufacturer or responsible vendor 1.3.4 lamp designation: type E Code, indicating economy, to designate a type of low-pressure sodium vapour lamp with improved luminous efficacy NOTE As these lamps may be operated on various ballasts with slightly different wattages, i

32、t is not satisfactory to designate them with a nominal wattage. A lamp designation has been chosen consisting of the letter E and a number approximately numerically equal to their rated wattage. The number in the designation is different from that of the rated wattage, in order to avoid confusion wi

33、th the existing lamps designated with their nominal wattage. 1.3.5 lamp starting voltage r.m.s. voltage at lamp terminals at which the lamp starts 1.3.6 initial readings starting characteristics of a lamp, measured before ageing, and the electrical and photometric characteristics of a lamp, measured

34、 at the end of the ageing period 1.3.7 reference ballast special inductive type ballast, designed for the purpose of providing comparison standards for use in testing ballasts, for the selection of reference lamps and for testing regular production lamps under standardised conditions. It is essentia

35、lly characterized by the fact that at its rated frequency, it has a stable voltagelcurrent ratio which is relatively uninfluenced by variations in current, temperature and magnetic surroundings, as outlined in the relevant ballast standard 1.3.8 calibration current of a reference ballast value of th

36、e current on which the calibration and control of the reference ballast are based Page 6 EN 60192:2001 1.3.9 type test test or a series of tests made on a type test sample for the purpose of checking compliance of the design of a given product with the requirements of the relevant standard 1.3.10 ty

37、pe test sample sample consisting of one or more similar units submitted by the manufacturer or the responsible vendor for the purpose of a type test 1.4 Lamp requirements 1.4.1 General A lamp, on which compliance with this standard is claimed, shall comply with the requirements of IEC 62035. A lamp

38、shall be so designed that its performance is reliable in normal and accepted use. In general, this can be achieved by satisfying the requirements of the following subclauses. The requirements given apply to 95 % of production. 1.4.2 Dimensions The dimensions of a lamp shall comply with the values sp

39、ecified on the relevant lamp data sheet. 1.4.3 Caps The cap on a finished lamp shall comply with IEC 60061-1. 1.4.4 Starting characteristics A lamp shall start within the starting time specified on the relevant lamp data sheet and remain alight for at least 1 min. The test shall be made before agein

40、g, using the measuring method given in annex A. 1.4.5 Electrical characteristics The initial readings of the voltage at lamp terminals and of the power dissipated by a lamp shall not exceed the maximum values specified on the relevant lamp data sheet, using the measuring method given in annex B. 1.4

41、.6 Photometric characteristics The initial reading of the luminous flux of a lamp shall be not less than 90 % of the rated value, using the measuring method given in annex B. 1.5 Information for luminaire design Refer to annex C for information for luminaire design. Page 7 EN 60192:2001 Annex A (nor

42、mative) Method of measuring starting characteristics A.l General Lamps shall not be operated during the 5 h immediately prior to making this test. Lamps shall be tested in a circuit as shown in figure A.l, at an ambient temperature between 20 OC and 30 OC, using a nominal 50 Hz or 60 Hz supply as ap

43、propriate. The ballast used shall satisfy the requirements of IEC 60923. During the test, lamps shall be at a sufficient distance from any earthed metal or starting aid. A.2 Measurement With switch S, closed and switch S2 open, the voltage measured by voltmeter V, shall be set to the starting voltag

44、e given on the relevant lamp data sheet, and then switch S2 shall be closed. After the test, switch Si shall be opened before switching off the lamp. IEC 525/01 Key 1. Supply 2. Ballast 3. Lamp Figure A.l - Circuit diagram for starting test Page 8 EN 60192:2001 Annex B (normative) Method of measurin

45、g electrical and photometric characteristics 6.1 General Lamps shall be tested in a circuit as shown in figure B.l, at an ambient temperature of between 20 OC and 30 OC, using a nominal 50 Hz or 60 Hz supply as appropriate. Ballasts used for these measurements shall be reference ballasts having a vo

46、ltage-to-current ratio and power factor as specified on the relevant lamp data sheets and meeting the general requirements for reference ballasts given in IEC 60923. Before initial readings are taken, the lamp shall be aged for 100 h on a ballast that satisfies the requirements of IEC 60923, at the

47、rated voltage and frequency of the ballast. The supply voltage shall not vary by more than i10 % and the frequency by not more than il Hz. NOTE The allowed tolerances are chosen to avoid the necessity of having a stabilized voltage and to permit the use of a normal mains supply. Lamps shall operate

48、within i5“ of the horizontal position 6.2 Supply The supply voltage and frequency shall be equal to the rated values of the reference ballast, with a tolerance of I0,5 %. The wave shape of the supply voltage shall be a sine wave. The total harmonic content shall not exceed 3 % of the fundamental. Th

49、e total harmonic content is defined as the root-mean- square (r.m,s.) summation of the individual harmonic components, using the fundamental as 100 %. NOTE This implies that the source of supply should have sufficient power and that the supply circuit should have a sufficiently low impedance compared with the ballast impedance and care should be taken that this applies under all conditions that occur during the measurement. During the period of stabilisation, the supply voltage and frequency shall be stable within I0,5 %, this tolerance being reduced to k0,2 % at the moment of m