EN 60286-6-2004 en Packaging of components for automatic handling Part 6 Bulk case packaging for surface mounting components《自动装配用元件的包装 第6部分 表面安装组件的批量包装 IEC 60286-6-2004》.pdf

上传人:brainfellow396 文档编号:717800 上传时间:2019-01-04 格式:PDF 页数:18 大小:357.97KB
下载 相关 举报
EN 60286-6-2004 en Packaging of components for automatic handling Part 6 Bulk case packaging for surface mounting components《自动装配用元件的包装 第6部分 表面安装组件的批量包装 IEC 60286-6-2004》.pdf_第1页
第1页 / 共18页
EN 60286-6-2004 en Packaging of components for automatic handling Part 6 Bulk case packaging for surface mounting components《自动装配用元件的包装 第6部分 表面安装组件的批量包装 IEC 60286-6-2004》.pdf_第2页
第2页 / 共18页
EN 60286-6-2004 en Packaging of components for automatic handling Part 6 Bulk case packaging for surface mounting components《自动装配用元件的包装 第6部分 表面安装组件的批量包装 IEC 60286-6-2004》.pdf_第3页
第3页 / 共18页
EN 60286-6-2004 en Packaging of components for automatic handling Part 6 Bulk case packaging for surface mounting components《自动装配用元件的包装 第6部分 表面安装组件的批量包装 IEC 60286-6-2004》.pdf_第4页
第4页 / 共18页
EN 60286-6-2004 en Packaging of components for automatic handling Part 6 Bulk case packaging for surface mounting components《自动装配用元件的包装 第6部分 表面安装组件的批量包装 IEC 60286-6-2004》.pdf_第5页
第5页 / 共18页
点击查看更多>>
资源描述

1、BRITISH STANDARD BS EN 60286-6:2004 Packaging of components for automatic handling Part 6: Bulk case packaging for surface mounting components The European Standard EN 60286-6:2004 has the status of a British Standard ICS 31.020 BS EN 60286-6:2004 This British Standard was published under the author

2、ity of the Standards Policy and Strategy Committee on 16 September 2004 BSI 16 September 2004 ISBN 0 580 44460 0 National foreword This British Standard is the official English language version of EN 60286-6:2004. It is identical with IEC 60286-6:2004. It supersedes BS EN 60286-6:1999 which is withd

3、rawn. The UK participation in its preparation was entrusted to Technical Committee EPL/40X, Capacitors and resistors for electronic equipment, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The Brit

4、ish Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Onl

5、ine. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsi

6、ble international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover,

7、 the EN title page, pages 2 to 14, an inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEAN STANDARD EN 60286-6 NORME EUROPENNE EUROPISCHE NORM March 2004

8、 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2004 CENELEC - All rights of exploitation in any form and by any means reserved

9、 worldwide for CENELEC members. Ref. No. EN 60286-6:2004 E ICS 31.020 Supersedes EN 60286-6:1998English version Packaging of components for automatic handling Part 6: Bulk case packaging for surface mounting components (IEC 60286-6:2004) Emballage des composants pour oprations automatises Partie 6:

10、Emballage en vrac des composants pour montage en surface (CEI 60286-6:2004) Gurtung und Magazinierung von Bauelementen fr automatische Verarbeitung Teil 6: Schttgutbehlter fr oberflchenmontierbare Bauelemente (IEC 60286-6:2004) This European Standard was approved by CENELEC on 2004-03-01. CENELEC me

11、mbers are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on applica

12、tion to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat

13、 has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Po

14、land, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. Foreword The text of document 40/1365/FDIS, future edition 2 of IEC 60286-6, prepared by IEC TC 40, Capacitors and resistors for electronic equipment, was submitted to the IEC-CENELEC parallel vote and was approved by

15、 CENELEC as EN 60286-6 on 2004-03-01. This European Standard supersedes EN 60286-6:1998. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2004-12-01 latest date by which the na

16、tional standards conflicting with the EN have to be withdrawn (dow) 2007-03-01 The International Electrotechnical Commission (IEC) and CENELEC draw attention to the fact that it is claimed that compliance with this document may involve the use of a patent concerning the structure of the bulk case gi

17、ven in 4.1. The IEC and CENELEC take no position concerning the evidence, validity and scope of this patent right. The holder of this patent right has assured the IEC that he is willing to negotiate licences under reasonable and non-discriminatory terms and conditions with applicants throughout the

18、world. In this respect, the statement of the holder of this patent right is registered with the IEC. Information may be obtained from: Murata Manufacturing Co., Ltd. 26-10, 2-Chome Tenjin Nagaokakyo-Shi Kyoto 617-8555 JAPAN Fax: +81-75-955-6526 E-Mail: wwwmurataa.co.jp Attention is drawn to the poss

19、ibility that some of the elements of this document may be the subject of patent rights other than those identified above. IEC and CENELEC shall not be held responsible for identifying any or all such patent rights. Annex ZA has been added by CENELEC. _ Endorsement notice The text of the Internationa

20、l Standard IEC 60286-6:2004 was approved by CENELEC as a European Standard without any modification. _ Page2 EN602866:2004 CONTENTS 1 Scope.4 2 Normative references4 3 Terms and definitions .4 4 Requirements .5 4.1 Case assembly5 4.2 Shutter mechanism5 4.3 Dimensions .5 4.4 Material .7 4.5 Mechanica

21、l characteristics.8 5 Marking 8 Annex A (informative) Packing capacity9 A.1 Component types.9 A.2 Component quantities9 Annex B (informative) Indication of residual SMDs11 B.1 Indication of residual SMDs .11 Annex C (informative) Label information.12 C.1 Label material12 C.2 Adhesive property of the

22、 label12 Annex D (informative) Characteristics and test methods of bulk case13 Annex ZA (normative) Normative references to International publications with their corresponding publications 14 Figure 1 Bulk case General view5 Figure 2 Dimensions 6 Table 1 Dimensions of coupling interface7 Table A.1 C

23、apacitors9 Table A.2 Resistors9 Table A.3 Resistors (cylindrical) .10 Table D.1 Characteristics and test methods of bulk case 13 Page3 EN602866:2004 PACKAGING OF COMPONENTS FOR AUTOMATIC HANDLING Part 6: Bulk case packaging for surface mounting components 1 Scope This part of IEC 60286 is applicable

24、 to bulk case packaging capable of containing surface mounting components. The bulk case is designed for transport and storage of components and the supply of components directly or by an appropriate feeder to the placement machine. The bulk case is attached to the automatic handling machine by mean

25、s of a coupling interface. NOTE For size limitations of components, see Annex A, Tables A.1, A.2 and A.3. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, th

26、e latest edition of the referenced document (including any amendments) applies. IEC 60093: Methods of test for volume resistivity and surface resistivity of solid electrical insulating materials ISO 180: Plastics Determination of Izod impact strength ISO 2248: Packaging Complete filled transport pac

27、kages Vertical impact test by dropping ISO 6906: Vernier callipers reading to 0,02 mm ISO 11469: Plastics Generic identification and marking of plastic products ISO/IEC 16388: Information tefhnology Automatic identification and data capture techniques Bar code technology spefifications Code 39 3 Ter

28、ms and definitions For the purposes of this document the following definition applies. 3.1 destaticized plastics (electrostatic dissipative plastics) plastics with a surface resistivity of more than or equal to 1,0 10 5 per square, but less than or equal to 1,0 10 12 per square. Page4 EN602866:2004

29、4 Requirements 4.1 Case assembly For details about the label, see Annex C. Figure 1 shows the general view of the assembly of the bulk case. Label Shutter mechanism Access hole Coupling interface IEC 1 417/98Figure 1 Bulk case General view 4.2 Shutter mechanism The bulk case shall have a slide combi

30、ned with a shutter to open and close the access hole. 4.3 Dimensions A general description and letter symbols for individual dimensions are given in Figure 2. A proportion scale shall be on the side opposite the label to indicate the percentage of contents remaining. See for further residual indicat

31、ion Annex B. Optional: a suitable number of small vent holes may be provided in the end face of the case. Page5 EN602866:2004 H 1 L 2 X X X-X H 5 H 6 H 7 L 1 L 3 P 1 W 4 H 2 H 3 H 4 L 4 P 2 W 1 W 2 W 3 P 3 IEC 2912/03Figure 2 Dimensions 4.3.1 Overall dimensions Length L 1= 36,0 0,20 mm Height H 1= 1

32、10 mm 0,7 mm Width W 1= 12,0 mm 0,1 mm Page6 EN602866:2004 4.3.2 Coupling interface See Table 1. Table 1 Dimensions of coupling interface Dimensions in millimetres Length of coupling interface L 20 02 31 5 + , ,Length of access hole (typical) L 319 Height H 20 01 15 + , ,Height H 301 0 20 , ,Height

33、H 40 02 30 + , ,Height H 5 (typical) 11 Height H 6 (typical) 1,9 Height H 71,0 0,1 Width P 31,6 0,1 Width W 28,8 0,1 Width W 3 6,8 0,1 Width of access hole (typical) W 45 Access hole position P 1 (nominal dimension) 7 4.3.3 Slide/shutter Slide length (typical) L 4 = 10 mm Slide start position (acces

34、s hole completely open) P 2 = 53,3 mm 4.4 Material The material of the bulk case shall be electrostatically dissipative and shall be transparent or translucent. It shall not adversely affect the mechanical and electrical characteristics, solderability, or marking of the devices during or after trans

35、port and storage. 4.4.1 Recycling Bulk cases defined in Figures 1 and 2 shall be permanently and visibly marked with an appropriate recycling symbol. ISO 11469 is recommended. Page7 EN602866:2004 4.5 Mechanical characteristics 4.5.1 Mechanical stability Mechanical stability of loaded bulk cases duri

36、ng storage, transport and use shall be such that the components are retained without damage and that they can be easily removed. 4.5.2 Characteristics and test method See Annex D, Table D.1. 5 Marking The bulk case shall provide space for a peelable label. The label shall be fixed onto the front and

37、 the shutter mechanism side as shown in Figure 1. The marking on the label shall comply with the requirements of the detail specification of the component. Information may be given by normal script or in code form for automatic reading, for example OCR, bar code, magnetic, etc. In the case of bar co

38、des, it is recommended to use bar code 39 as specified in ISO/IEC 16388. For optical character recognition (OCR), OCR B should be used. For recycling symbology, see 4.4.1. Page8 EN602866:2004 Annex A (informative) Packing capacity A.1 Component types This packaging technique can be applied to small

39、sized surface mounting devices, for example certain capacitors, resistors and other electronic or electromechanical components. A.2 Component quantities Typical quantities for specific sizes of capacitors and resistors are shown in Tables A.1, A.2 and A.3. Table A.1 Capacitors Typical dimensions Sty

40、le code Length L mm Width W mm Thickness T mm Typical quantities pcs 1005M 1,0 0,5 0,5 50 000 1608M 1,6 0,8 0,8 15 000 2012M 2,0 1,25 0,6 1,25 10 000 5 000 NOTE The identifier M after the style code indicates a metric dimension base. Table A.2 Resistors Typical dimensions Style code Length L mm Widt

41、h W mm Thickness T mm Typical quantities pcs 1005M 1,0 0,5 0,35 50 000 1608M 1,6 0,8 0,45 25 000 2012M 2,0 1,25 0,55 10 000 NOTE The identifier M after the style code indicates a metric dimension base. Page9 EN602866:2004 Table A.3 Resistors (cylindrical) Typical dimensions Style code Length L mm Di

42、ameter D mm Typical quantities pcs RC 3514M 3,5 1,4 3 000 RC 2211M 2,2 1,1 8 000 NOTE - The identifier M after the style code indicates a metric dimension base. Page10 EN602866:2004 Annex B (informative) Indication of residual SMDs B.1 Indication of residual SMDs Assuming that the distance from the

43、inside wall of the bottom wall to the inside wall of the opening is 100 %, put markings of 10, 9, 8, 7, 6, 5, 4, 3, 2, 1 and 0 on the case at each height of 100 %, 90 %, 80 %, 70 %, 60 %, 50 %, 40 %, 30 %, 20 %, 10 %, and 0 % distance, respectively, as an indicator of residual amount of SMDs. Page11

44、 EN602866:2004 Annex C (informative) Label information C.1 Label material Not specified. However, when the original peelable label is not removed and another label is put over the original one (e.g. when reusing the bulk case), labels of the same material shall be used. If a plastic label is used, i

45、ts material shall be indicated on the label in accordance with ISO 11469. C.2 Adhesive property of the label When the bulk case is stored at the temperature of 25 C to +50 C and at the relative humidity of 45 % to 75 %, the label shall be capable of being peeled from the bulk case, prior to re-use.

46、Page12 EN602866:2004 Annex D (informative) Characteristics and test methods of bulk case Table D.1 Characteristics and test methods of bulk case No. Item Performance Test method 1 Material strength Izod impact strength 30 J/m or more As per ISO 180 “Determination of Izod impact strength”. 2 Surface

47、resistivity 1,0 10 5 per square to 1,0 10 12 per square As per IEC 60093 “Methods of test for volume resistivity and surface resistivity of solid electrical insulating materials” 3 Dropping strength There shall be no abnormalities including flaws and looseness in engaging parts, nor significant chan

48、ge in appearance. The empty bulk case shall be freely dropped, with its opening downward, one time from a height of 1 m. Other conditions shall conform to ISO 2248 ”Packings-Vertical impact test by dropping”. 4 Sliding force The sliding force of the shutter shall be 1 N to 5 N before and after the t

49、est. The sliding force shall be measured with a push- pull gauge before start of sliding and after 50 times of sliding the shutter. 5 Exposure to high temperature Specified dimensions in 4.3 shall be met. There shall be no abnormalities such as looseness in engaging parts, nor significant change in appearance. After exposure to the ambient

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1