EN 60317-27-2014 en Specifications for particular types of winding wires - Part 27 Paper tape covered rectangular copper wire.pdf

上传人:feelhesitate105 文档编号:717860 上传时间:2019-01-04 格式:PDF 页数:16 大小:1.03MB
下载 相关 举报
EN 60317-27-2014 en Specifications for particular types of winding wires - Part 27 Paper tape covered rectangular copper wire.pdf_第1页
第1页 / 共16页
EN 60317-27-2014 en Specifications for particular types of winding wires - Part 27 Paper tape covered rectangular copper wire.pdf_第2页
第2页 / 共16页
EN 60317-27-2014 en Specifications for particular types of winding wires - Part 27 Paper tape covered rectangular copper wire.pdf_第3页
第3页 / 共16页
EN 60317-27-2014 en Specifications for particular types of winding wires - Part 27 Paper tape covered rectangular copper wire.pdf_第4页
第4页 / 共16页
EN 60317-27-2014 en Specifications for particular types of winding wires - Part 27 Paper tape covered rectangular copper wire.pdf_第5页
第5页 / 共16页
点击查看更多>>
资源描述

1、BSI Standards PublicationSpecifications for particular types of winding wiresPart 27: Paper tape covered rectangular copper wireBS EN 60317-27:2014National forewordThis British Standard is the UK implementation of EN 60317-27:2014. It isidentical to IEC 60317-27:2013. It supersedes BS EN 60317-27:19

2、98 which iswithdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee GEL/55, Winding wires.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contra

3、ct. Users are responsible for its correct application. The British Standards Institution 2014.Published by BSI Standards Limited 2014ISBN 978 0 580 75366 4ICS 29.060.10Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the author

4、ity of theStandards Policy and Strategy Committee on 28 February 2014.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 60317-27:2014EUROPEAN STANDARD EN 60317-27 NORME EUROPENNE EUROPISCHE NORM February 2014 CENELEC European Committee for Electrotechnical Standar

5、dization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B - 1000 Brussels 2014 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 6031

6、7-27:2014 E ICS 29.060.10 Supersedes EN 60317-27:1998 + A1:2000 English version Specifications for particular types of winding wires - Part 27: Paper tape covered rectangular copper wire (IEC 60317-27:2013) Spcifications pour types particuliers de fils de bobinage - Partie 27: Fil de section rectang

7、ulaire en cuivre recouvert de ruban papier (CEI 60317-27:2013) Technische Lieferbedingungen fr bestimmte Typen von Wickeldrhten - Teil 27: Flachdrhte aus Kupfer, papierisoliert (IEC 60317-27:2013) This European Standard was approved by CENELEC on 2013-11-14. CENELEC members are bound to comply with

8、the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Managem

9、ent Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the sa

10、me status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Li

11、thuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 60317-27:2014EN 60317-27:2014 - 2 - Foreword The text of document 55/1414/FDIS, future edition 4 of IEC 60317-27, prepared by IEC/TC 55

12、 “Winding wires“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 60317-27:2014. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2014-08-14 la

13、test date by which the national standards conflicting with the document have to be withdrawn (dow) 2016-11-14 This document supersedes EN 60317-27:1998. EN 60317-27:2014 includes the following significant technical changes with respect to EN 60317-27:1998: new subclause containing general notes on w

14、inding wire, formerly a part of the scope; revision to references to EN 60317-0-2:2014 to clarify that their application is normative; new 3.3, Appearance; modification to 4.4, Increase in dimensions due to paper tape covering; deletion of Clause 22, High temperature failure; new Clause 23, Pin hole

15、 test. This standard is to be read in conjunction with EN 60317-0-2:2014. The numbering of clauses in this standard is not continuous from Clauses 20 and 30 in order to reserve space for possible future wire requirements prior to those for wire packaging. Attention is drawn to the possibility that s

16、ome of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 60317-27:2013 was approved by CENELEC as a European Standard without

17、 any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60264 Series NOTE Harmonized as EN 60264 Series (not modified). IEC 60317 Series NOTE Harmonized as EN 60317 Series (not modified). IEC 60851 Series NOTE Harmonized as

18、EN 60851 Series (not modified). ISO 6892-1:2009 NOTE Harmonized as EN ISO 6892-1:2009 (not modified). BS EN 60317-27:2014- 3 - EN 60317-27:2014 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or

19、in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has b

20、een modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60317-0-2 2013 Specifications for particular types of winding wires - Part 0-2: General requirements - Enamelled rectangular copper wire EN 60317-0-2 2014 IEC 60554-1 - Specifi

21、cation for cellulosic papers for electrical purposes - Part 1: Definitions and general requirements - - BS EN 60317-27:2014 2 60317-27 IEC:2013 CONTENTS INTRODUCTION . 5 1 Scope . 6 2 Normative references . 6 3 Terms, definitions, general notes and appearance 6 3.1 Terms and definitions 6 3.2 Genera

22、l notes 6 3.2.1 Methods of test 6 3.2.2 Winding wire 7 3.3 Appearance . 7 4 Dimensions 7 4.1 Conductor dimensions . 7 4.2 Tolerance on conductor dimensions 7 4.3 Rounding of corners 7 4.4 Increase in dimensions due to paper tape covering . 7 4.5 Maximum overall dimensions . 8 5 Electrical resistance

23、 . 8 6 Elongation 8 7 Springiness 8 8 Flexibility and adherence 8 9 Heat shock . 8 10 Cut-through 8 11 Resistance to abrasion . 9 12 Resistance to solvents 9 13 Breakdown voltage . 9 14 Continuity of insulation . 9 15 Temperature index . 9 16 Resistance to refrigerants . 9 17 Solderability . 9 18 He

24、at or solvent bonding 9 19 Dielectric dissipation factor . 9 20 Resistance to hydrolysis and to transformer oil . 9 21 Loss of mass 9 23 Pin hole test . 9 30 Packaging 10 Annex A (informative) Method of determination of x % proof stress: Rpx 11 Bibliography 12 Figure A.1 Load-elongation diagram 11 T

25、able 1 Increase in dimensions 8 BS EN 60317-27:201460317-27 IEC:2013 5 INTRODUCTION This part of IEC 60317 is one of a series which deals with insulated wires used for windings in electrical equipment. The series has three groups describing: 1) Winding wires Test methods (IEC 60851); 2) Specificatio

26、ns for particular types of winding wires (IEC 60317); 3) Packaging of winding wires (IEC 60264). BS EN 60317-27:2014 6 60317-27 IEC:2013 SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES Part 27: Paper tape covered rectangular copper wire 1 Scope This part of IEC 60317 specifies the requirements

27、of paper tape covered rectangular copper winding wires. This covering consists of two or more layers of paper tape, all in the same direction and is primarily intended for winding coils for oil immersed transformers. The range of nominal conductor dimensions covered by this standard is: width: min.

28、2,0 mm max. 16,0 mm; thickness: min. 0,80 mm max. 5,60 mm. The paper tapes covered by this standard are restricted to those specified in IEC 60554-1 having thicknesses in the range 25 m to 125 m inclusive. 2 Normative references The following documents, in whole or in part, are normatively reference

29、d in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60317-0-2:2013, Specifications for particular types of winding wires Part

30、0-2: General requirements Enamelled rectangular copper wire IEC 60554-1, Specification for cellulosic papers for electrical purposes Part 1: Definitions and general requirements 3 Terms, definitions, general notes and appearance 3.1 Terms and definitions For the purposes of this document, the terms

31、and definitions given in IEC 60317-0-2 and the following apply. 3.1.1 covering material which is wound, wrapped or braided around a bare or insulated conductor 3.2 General notes 3.2.1 Methods of test Subclause 3.2.1 of IEC 60317-0-2:2013 applies. In case of inconsistency between IEC 60317-0-2:2013 a

32、nd this standard, IEC 60317-27 shall prevail. BS EN 60317-27:201460317-27 IEC:2013 7 3.2.2 Winding wire The number of paper tapes, type of paper, paper tape thickness, and the degree of overlap shall be agreed upon between the purchaser and supplier. When a reference is made to winding wire accordin

33、g to this standard, the following information shall be given in the description: reference to IEC 60317-27; nominal conductor dimensions in millimetres (width thickness); nominal increase in dimensions due to paper. EXAMPLE: IEC 60317-27 4,00 1,00 + 0,20 proof stress minimum (and maximum) value EXAM

34、PLES: IEC 60317-27 4,00 1,00 + 0,20 IEC 60317-27 7,00 2,50 + 1,00 Rp0,2 = 150 MPa 3.3 Appearance The conductor shall be essentially free from copper dust and other extraneous matter when examined with normal vision, as wound on the original spool or reel. The paper covering shall be of one or more t

35、apes wrapped firmly, closely, evenly, and continuously around the conductor. No bonding or adhesive material shall be used except to anchor the ends of paper tapes. 4 Dimensions 4.1 Conductor dimensions Subclause 4.1 of IEC 60317-0-2: 2013 applies. 4.2 Tolerance on conductor dimensions Subclause 4.2

36、 of IEC 60317-0-2: 2013 applies. 4.3 Rounding of corners Subclause 4.3 of IEC 60317-0-2: 2013 applies. 4.4 Increase in dimensions due to paper tape covering The increase in width or thickness due to the paper tape covering shall be agreed between purchaser and supplier and the minus tolerance shall

37、not exceed the values given in Table 1. The increase in width due to the paper covering shall be equal to or less than the increase in thickness. The maximum increase may be exceeded, provided that the maximum overall dimension does not exceed the sum of the maximum dimensions of the conductor plus

38、the maximum increase given in Table 1. BS EN 60317-27:2014 8 60317-27 IEC:2013 Table 1 Increase in dimensions Increase in dimensions due to the paper covering mm Tolerance % Over Up to and including 0,50 0100,50 1,25 07 5 ,1,25 054.5 Maximum overall dimensions The overall dimensions shall be measure

39、d under a pressure of (1 0,1) N/mm2over the cross-section of the bare conductor nominal dimension. The overall dimensions shall not exceed the sum of the maximum bare dimensions given in 4.2 and the maximum increase in dimensions permitted in 4.4. 5 Electrical resistance Clause 5 of IEC 60317-0-2:20

40、13 applies. 6 Elongation Clause 6 of IEC 60317-0-2:2013 applies. NOTE When the value of the proof stress of the copper is specified between minimum and maximum limits, the requirements are agreed upon between the purchaser and supplier. The description of the term “proof stress” and the method of de

41、termination are given in Annex A. 7 Springiness Test appropriate but no requirements specified. 8 Flexibility and adherence Because of the great variation in the number and the thickness of papers applied, the requirements for flexibility shall be agreed between purchaser and supplier at the time of

42、 placing the order. 9 Heat shock Test inappropriate. 10 Cut-through Test inappropriate. BS EN 60317-27:201460317-27 IEC:2013 9 11 Resistance to abrasion Test inappropriate. 12 Resistance to solvents Test inappropriate. 13 Breakdown voltage Test inappropriate. 14 Continuity of insulation Test inappro

43、priate. 15 Temperature index Test requirements under consideration. 16 Resistance to refrigerants Test inappropriate. 17 Solderability Test inappropriate. 18 Heat or solvent bonding Test inappropriate. 19 Dielectric dissipation factor Test inappropriate. 20 Resistance to hydrolysis and to transforme

44、r oil Test appropriate but no requirements specified. 21 Loss of mass Test inappropriate. 23 Pin hole test Test inappropriate. BS EN 60317-27:2014 10 60317-27 IEC:2013 30 Packaging The kind of packaging may influence certain properties of the wire, for example flexibility and adherence. Therefore th

45、e kind of packaging, for example the type of spool, shall be agreed between purchaser and supplier. The wire shall be evenly and compactly wound on spools. Where wires are delivered in coils, the dimensions and the maximum masses of such coils shall be agreed between purchaser and supplier. Any addi

46、tional protection for coils shall also be agreed between purchaser and supplier. A clearance of at least 25 mm shall be arranged between the outermost layer and the periphery of the spool flange. Where there is a requirement for a protective paper between the layers and between the wire and the spoo

47、l, this shall be agreed between the purchaser and the supplier. Marking of the label when there is more than one length, identification of the separate lengths and identification of joints shall also be by agreement between the purchaser and supplier. BS EN 60317-27:201460317-27 IEC:2013 11 Annex A

48、(informative) Method of determination of x % proof stress: Rpx Proof stress is the stress (load divided by the original area of cross-section of a test piece) which is just sufficient to produce, under increasing load, a non-proportional elongation equal to a specified percentage x of the original g

49、auge length. In specifying or describing a proof stress the percentage should be quoted: the most usual example is 0,2 % proof stress (Rp0,2) expressed in megapascals (1 MPa = 1 N/mm2). The proof stress is determined from the load-elongation curve by drawing a line parallel to the straight portion of the curve and distant from it by an amount representing the required non-proportional elongation, thus determining the load at which the line cuts the curve (see Fi