EN 60512-15-5-2008 en Connectors for electronic equipment - Tests and measurements - Part 15-5 Connector tests (mechanical) - Test 15e Contact retention in insert cable nutation《电子.pdf

上传人:lawfemale396 文档编号:718249 上传时间:2019-01-04 格式:PDF 页数:10 大小:443.26KB
下载 相关 举报
EN 60512-15-5-2008 en Connectors for electronic equipment - Tests and measurements - Part 15-5 Connector tests (mechanical) - Test 15e Contact retention in insert cable nutation《电子.pdf_第1页
第1页 / 共10页
EN 60512-15-5-2008 en Connectors for electronic equipment - Tests and measurements - Part 15-5 Connector tests (mechanical) - Test 15e Contact retention in insert cable nutation《电子.pdf_第2页
第2页 / 共10页
EN 60512-15-5-2008 en Connectors for electronic equipment - Tests and measurements - Part 15-5 Connector tests (mechanical) - Test 15e Contact retention in insert cable nutation《电子.pdf_第3页
第3页 / 共10页
EN 60512-15-5-2008 en Connectors for electronic equipment - Tests and measurements - Part 15-5 Connector tests (mechanical) - Test 15e Contact retention in insert cable nutation《电子.pdf_第4页
第4页 / 共10页
EN 60512-15-5-2008 en Connectors for electronic equipment - Tests and measurements - Part 15-5 Connector tests (mechanical) - Test 15e Contact retention in insert cable nutation《电子.pdf_第5页
第5页 / 共10页
点击查看更多>>
资源描述

1、BRITISH STANDARDBS EN 60512-15-5:2008Connectors for electronic equipment Tests and measurements Part 15-5: Connector tests (mechanical) Test 15e: Contact retention in insert, cable nutationICS 31.220.10g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g

2、40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 60512-15-5:2008This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 September 2008 BSI 2008ISBN 978 0 580 55903 7National forewordThis B

3、ritish Standard is the UK implementation of EN 60512-15-5:2008. It is identical to IEC 60512-15-5:2008.The UK participation in its preparation was entrusted to Technical Committee EPL/48, Electromechanical components and mechanical structures for electronic equipment.A list of organizations represen

4、ted on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendments/cor

5、rigenda issued since publicationDate CommentsEUROPEAN STANDARD EN 60512-15-5 NORME EUROPENNE EUROPISCHE NORM July 2008 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat:

6、 rue de Stassart 35, B - 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60512-15-5:2008 E ICS 31.220.10 English version Connectors for electronic equipment - Tests and measurements - Part 15-5: Connector tests

7、(mechanical) - Test 15e: Contact retention in insert, cable nutation (IEC 60512-15-5:2008) Connecteurs pour quipements lectroniques - Essais et mesures - Partie 15-5: Essais (mcaniques) des connecteurs - Essai 15e: Rtention du contact dans lisolant par nutation du cble (CEI 60512-15-5:2008) Steckver

8、binder fr elektronische Einrichtungen - Mess- und Prfverfahren - Teil 15-5: Mechanische Prfungen an Steckverbindern - Prfung 15e: Kontakthalterung im Einsatz - Kabelbeanspruchung (IEC 60512-15-5:2008) This European Standard was approved by CENELEC on 2008-07-01. CENELEC members are bound to comply w

9、ith the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secreta

10、riat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the

11、 official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Por

12、tugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Foreword The text of document 48B/1847/FDIS, future edition 1 of IEC 60512-15-5, prepared by SC 48B, Connectors, of IEC TC 48, Electromechanical components and mechanical structures for electronic equipment, was s

13、ubmitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60512-15-5 on 2008-07-01. This standard is to be read in conjunction with EN 60512-1 and EN 60512-1-100 which explains the structure of the EN 60512 series. The following dates were fixed: latest date by which the EN has to

14、be implemented at national level by publication of an identical national standard or by endorsement (dop) 2009-04-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2011-07-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the Inte

15、rnational Standard IEC 60512-15-5:2008 was approved by CENELEC as a European Standard without any modification. _ BS EN 60512-15-5:2008 2 CONNECTORS FOR ELECTRONIC EQUIPMENT TESTS AND MEASUREMENTS Part 15-5: Connector tests (mechanical) Test 15e: Contact retention in insert, cable nutation 1 Scope a

16、nd object This part of IEC 60512, when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this document is to detail a standard test method to

17、 verify the capability of the contact retention system to withstand dynamic mechanical loading of the contacts that tends to dislodge them. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited a

18、pplies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60512-1-1, Connectors for electronic equipment Tests and measurements Part 1-1: General examination Test 1a: Visual examination IEC 60512-2-5: Connectors for electronic equipment Tes

19、ts and measurements Part 2-5: Electrical continuity and contact resistance tests Test 2e: Contact disturbance 3 Preparations 3.1 Preparation of specimen The specimen shall consist of a connector with its terminations. Any accessories, which do not form part of the contact system, may be removed. Any

20、 preconditioning given in the detail specification shall be applied. The contacts to be tested shall be attached to a flexible stranded steel cable of a diameter suitable for attachment to the contact under test and to support the specified mass shown on Figure 1. If specified in the detail specific

21、ation, a specified copper or other cable may be used. NOTE It may be necessary to enlarge the end of the cable before attachment to the contact(s), in order to prevent the cable pulling out of the contact during testing. Where the connector has four or more contacts, three contacts shall be selected

22、 at random provided that two contacts shall be near periphery and one near the centre of the connector insert or housing. All other contacts shall be installed. In the case where a corresponding connector is to be used, this shall have all contacts installed. BS EN 60512-15-5:2008 3 3.2 Equipment Te

23、st apparatus such as that shown in Figure 1 shall be provided. The mass shall be sufficient to provide tension in the cable without deforming the specimen under test. Unless otherwise stated in the detail specification, this shall be 1,4 kg 0,02 kg. NOTE 1 If the detail specification requires specia

24、l preconditioning of the specimen, all the necessary equipment detailed in the relevant documents describing such conditioning would also be required. NOTE 2 Another possible apparatus for this test is that of IEC 60999-1, Figure 1. If this apparatus is used, the 45 degree angle and the 1,4 kg load

25、shall be used. 45 5 2 3 XXXX1 IEC 722/08 Key 1 connector under test 2 swivel pulley 3 mass e.g. 1,4 kg Figure 1 Example of test apparatus NOTE 3 In this example, the connector is mounted in such a way that axis XX in the figure remains in a vertical position as the mounting surface is rotated. 3.3 M

26、ounting Connectors having no suitable mounting flange shall be mated to their corresponding fixed connector, which shall be mounted on the apparatus. In the case of neither connector having suitable mounting means, the corresponding connector shall be clamped to the apparatus in such a manner that d

27、oes not affect the validity of the test. NOTE See note under 4.1.2. BS EN 60512-15-5:2008 4 The connector, corresponding connector, or insert which is mounted on the apparatus, shall be prevented from rotating about its longitudinal axis. 4 Test method Unless otherwise stated in the detail specifica

28、tion, 3 connectors shall be tested. The connector shall be arranged on the apparatus as described in Clause 3 and shown on Figure 1. The apparatus shall be operated such that the connector under test is rotated through 360. This constitutes one cycle. This cycle shall be repeated 100 times at a rate

29、 of 10 to 20 cycles per minute. This procedure shall be repeated for the other contacts. 4.1 Measurements and requirements 4.1.1 Before testing Visual examination according to IEC 60512-1-1 shall be done. 4.1.2 During testing The contact shall not be either temporally or permanently fully or partial

30、ly dislodged from their normal position. If required by the detail specification, monitoring for electrical continuity may be done. In which case this shall be done according to IEC 60512-2-5. NOTE In the case of continuity monitoring, it will be necessary to mount both the connector under test and

31、its corresponding half, irrespective of the nature of mounting means provided by the connectors. 4.1.3 After testing Visual examination according to IEC 60512-1-1 shall be done. 5 Details to be specified When this test is required by a detail specification, the following shall be given therein: a) n

32、umber of connectors to be tested (if other than 3); b) preconditioning required; c) wiring of the specimen, if other than a steel cable given on Clause 3; d) if continuity monitoring is required; e) when c (above) is specified, criteria for discontinuity; f) voltage and current requirements; g) mass

33、 to be used if other than 1,4 kg; h) any deviation from the standard test method. BS EN 60512-15-5:2008 5 Bibliography IEC 60512-9:1992, Electromechanical components for electronic equipment; basic testing procedures and measuring methods Part 9: Miscellaneous tests1IEC 60999-1:1999, Connecting devi

34、ces Electrical copper conductors Safety requirements for screw-type and screwless-type clamping units Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2(included) _ _ 1Similar apparatus to that required by this test is used in test 17

35、a. NOTE Harmonized as EN 60999-1:2000 (not modified). BS EN 60512-15-5:2008 6 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated re

36、ferences, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title

37、 EN/HD Year IEC 60512-1-1 -1)Connectors for electronic equipment - Tests and measurements - Part 1-1: General examination - Test 1a: Visual examination EN 60512-1-1 20022)IEC 60512-2-5 -1)Connectors for electronic equipment - Tests and measurements - Part 2-5: Electrical continuity and contact resis

38、tance tests - Test 2e: Contact disturbance EN 60512-2-5 20032)1)Undated reference. 2)Valid edition at date of issue. BS EN 60512-15-5:2008 7 BS EN 60512-15-5:2008BSI Group Headquarters389 Chiswick High Road,London W4 4AL, UKTel +44 (0)20 8996 9001Fax +44 (0)20 8996 Standards Institution (BSI)BSI is

39、 the independent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter.RevisionsBritish Standards are updated by amendment or revision. Users of British Standards should make sure

40、that they possess the latest amendments or editions.It is the constant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using this British Standard would inform the Secretary of the technical committee responsible

41、, the identity of which can be found on the inside front cover. Tel: +44 (0)20 8996 9000 Fax: +44 (0)20 8996 7400BSI offers members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards.Buying standardsOrders for all BSI, int

42、ernational and foreign standards publications should be addressed to Customer Services. Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001 Email: You may also buy directly using a debit/credit card from the BSI Shop on the Website http:/ response to orders for international standards, it is BSI polic

43、y to supply the BSI implementation of those that have been published as British Standards, unless otherwise requested.Information on standardsBSI provides a wide range of information on national, European and international standards through its Library and its Technical Help to Exporters Service. Va

44、rious BSI electronic information services are also available which give details on all its products and services. Contact the Information Centre. Tel: +44 (0)20 8996 7111 Fax: +44 (0)20 8996 7048 Email: Subscribing members of BSI are kept up to date with standards developments and receive substantia

45、l discounts on the purchase price of standards. For details of these and other benefits contact Membership Administration. Tel: +44 (0)20 8996 7002 Fax: +44 (0)20 8996 7001 Email: Information regarding online access to British Standards via British Standards Online can be found at http:/ information

46、 about BSI is available on the BSI website at http:/.CopyrightCopyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of the publications of the international standardization bodies. Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be

47、reproduced, stored in a retrieval system or transmitted in any form or by any means electronic, photocopying, recording or otherwise without prior written permission from BSI. This does not preclude the free use, in the course of implementing the standard, of necessary details such as symbols, and size, type or grade designations. If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained. Details and advice can be obtained from the Copyright & Licensing Manager. Tel: +44 (0)20 8996 7070 Email:

展开阅读全文
相关资源
猜你喜欢
  • ASTM D4188-2017 Standard Practice for Performing Pressure In-Line Coagulation-Flocculation-Filtration Test in Water《水中进行压力在线混凝絮凝过滤试验的标准实施规程》.pdf ASTM D4188-2017 Standard Practice for Performing Pressure In-Line Coagulation-Flocculation-Filtration Test in Water《水中进行压力在线混凝絮凝过滤试验的标准实施规程》.pdf
  • ASTM D4189-2007 Standard Test Method for Silt Density Index (SDI) of Water《水的淤泥密度指数(SDI)的标准试验方法》.pdf ASTM D4189-2007 Standard Test Method for Silt Density Index (SDI) of Water《水的淤泥密度指数(SDI)的标准试验方法》.pdf
  • ASTM D4189-2007(2014) Standard Test Method for Silt Density Index &40 SDI&41 of Water《水污染密度指数(SDI)的标准试验方法》.pdf ASTM D4189-2007(2014) Standard Test Method for Silt Density Index &40 SDI&41 of Water《水污染密度指数(SDI)的标准试验方法》.pdf
  • ASTM D4190-2003 Standard Test Method for Elements in Water by Direct-Current Argon Plasma Atomic Emission Spectroscopy《用直流氩等离子体原子发射光谱法测定水中元素的标准试验方法》.pdf ASTM D4190-2003 Standard Test Method for Elements in Water by Direct-Current Argon Plasma Atomic Emission Spectroscopy《用直流氩等离子体原子发射光谱法测定水中元素的标准试验方法》.pdf
  • ASTM D4190-2008 Standard Test Method for Elements in Water by Direct-Current Argon Plasma Atomic Emission Spectroscopy《用直流氩等离子体原子辐射分光光度技术测定水中素的标准试验方法》.pdf ASTM D4190-2008 Standard Test Method for Elements in Water by Direct-Current Argon Plasma Atomic Emission Spectroscopy《用直流氩等离子体原子辐射分光光度技术测定水中素的标准试验方法》.pdf
  • ASTM D4190-2015 Standard Test Method for Elements in Water by Direct-Current Plasma Atomic Emission Spectroscopy《采用直流等离子体原子发射光谱法测定水中元素的标准试验方法》.pdf ASTM D4190-2015 Standard Test Method for Elements in Water by Direct-Current Plasma Atomic Emission Spectroscopy《采用直流等离子体原子发射光谱法测定水中元素的标准试验方法》.pdf
  • ASTM D4191-2003 Standard Test Method for Sodium in Water by Atomic Absorption Spectrophotometry《原子吸收分光光度法对水中钠含量的标准试验方法》.pdf ASTM D4191-2003 Standard Test Method for Sodium in Water by Atomic Absorption Spectrophotometry《原子吸收分光光度法对水中钠含量的标准试验方法》.pdf
  • ASTM D4191-2008 Standard Test Method for Sodium in Water by Atomic Absorption Spectrophotometry《原子吸收分光光度法对水中钠含量的标准试验方法》.pdf ASTM D4191-2008 Standard Test Method for Sodium in Water by Atomic Absorption Spectrophotometry《原子吸收分光光度法对水中钠含量的标准试验方法》.pdf
  • ASTM D4191-2015 Standard Test Method for Sodium in Water by Atomic Absorption Spectrophotometry《采用原子吸收光谱法的水中钠含量的标准试验方法》.pdf ASTM D4191-2015 Standard Test Method for Sodium in Water by Atomic Absorption Spectrophotometry《采用原子吸收光谱法的水中钠含量的标准试验方法》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1