EN 60512-16-7-2008 en Connectors for electronic equipment - Tests and measurements - Part 16-7 Mechanical tests on contacts and terminations - Test 16g Measurement of contact defor.pdf

上传人:appealoxygen216 文档编号:718267 上传时间:2019-01-04 格式:PDF 页数:12 大小:565.64KB
下载 相关 举报
EN 60512-16-7-2008 en Connectors for electronic equipment - Tests and measurements - Part 16-7 Mechanical tests on contacts and terminations - Test 16g Measurement of contact defor.pdf_第1页
第1页 / 共12页
EN 60512-16-7-2008 en Connectors for electronic equipment - Tests and measurements - Part 16-7 Mechanical tests on contacts and terminations - Test 16g Measurement of contact defor.pdf_第2页
第2页 / 共12页
EN 60512-16-7-2008 en Connectors for electronic equipment - Tests and measurements - Part 16-7 Mechanical tests on contacts and terminations - Test 16g Measurement of contact defor.pdf_第3页
第3页 / 共12页
EN 60512-16-7-2008 en Connectors for electronic equipment - Tests and measurements - Part 16-7 Mechanical tests on contacts and terminations - Test 16g Measurement of contact defor.pdf_第4页
第4页 / 共12页
EN 60512-16-7-2008 en Connectors for electronic equipment - Tests and measurements - Part 16-7 Mechanical tests on contacts and terminations - Test 16g Measurement of contact defor.pdf_第5页
第5页 / 共12页
点击查看更多>>
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI British StandardsWB9423_BSI_StandardColCov_noK_AW:BSI FRONT COVERS 5/9/08 12:55 Page 1Connectors forelectronic equipment Tests and measurements Part 16-7: Mechanical tests on contacts and termination

2、s Test 16g: Measurement ofcontact deformation after crimpingBS EN 60512-16-7:2008NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LANational forewordThis British Standard is the UK implementation of EN 60512-16-7:2008. Itis identical to IEC 60512-16-7:2008.The UK participation in i

3、ts preparation was entrusted to TechnicalCommittee EPL/48, Electromechanical components and mechanical structures for electronic equipment.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary p

4、rovisionsof a contract. Users are responsible for its correct application. BSI 2009ISBN 978 0 580 55913 6ICS 31.220.10Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy and Strategy Committee

5、on Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 60512-16-7:200831 January 2009EUROPEAN STANDARD EN 60512-16-7 NORME EUROPENNE EUROPISCHE NORM September 2008 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrote

6、chnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60512-16-7:2008 E ICS 31.220.10 English version Connectors fo

7、r electronic equipment - Tests and measurements - Part 16-7: Mechanical tests on contacts and terminations - Test 16g: Measurement of contact deformation after crimping (IEC 60512-16-7:2008) Connecteurs pour quipements lectroniques - Essais et mesures - Partie 16-7: Essais mcaniques des contacts et

8、des sorties - Essai 16g: Mesure de la dformation dun contact aprs sertissage (CEI 60512-16-7:2008) Steckverbinder fr elektronische Einrichtungen - Mess- und Prfverfahren - Teil 16-7: Mechanische Prfungen an Kontakten und Anschlssen - Prfung 16g: Kontaktverformung nach dem Crimpen (IEC 60512-16-7:200

9、8) This European Standard was approved by CENELEC on 2008-08-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographic

10、al references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a C

11、ENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungar

12、y, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 60512-16-7:2008EN 60512-16-7:2008 - 2 - Foreword The text of document 48B/1888/FDIS, future edition 1 of

13、IEC 60512-16-7, prepared by SC 48B, Connectors, of IEC TC 48, Electromechanical components and mechanical structures for electronic equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60512-16-7 on 2008-08-01. This standard is to be read in conjunction with EN

14、 60512-1 and EN 60512-1-100 which explains the structure of the EN 60512 series. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2009-05-01 latest date by which the national s

15、tandards conflicting with the EN have to be withdrawn (dow) 2011-08-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 60512-16-7:2008 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliograph

16、y, the following note has to be added for the standard indicated: IEC 60352-2 NOTE Harmonized as EN 60352-2:2006 (not modified). _ BS EN 60512-16-7:2008- 3 - EN 60512-16-7:2008 Annex ZA (normative) Normative references to international publications with their corresponding European publications The

17、following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modif

18、ied by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60512-1-1 - 1)Connectors for electronic equipment - Tests and measurements - Part 1-1: General examination - Test 1a: Visual examination EN 60512-1-1 2002 2)1)Undated reference. 2)Valid

19、 edition at date of issue. BS EN 60512-16-7:2008 4 60512-16-7 IEC:2008 CONNECTORS FOR ELECTRONIC EQUIPMENT TESTS AND MEASUREMENTS Part 16-7: Mechanical tests on contacts and terminations Test 16g: Measurement of contact deformation after crimping 1 Scope and object This part of IEC 60512, when requi

20、red by the detail specification, is used for testing connectors within the scope of IEC technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this part of IEC 60512 is to detail a standard test method to assess the effectiveness of co

21、ntacts to resist deformation (damage) from crimping operations. Although this test is intended for cylindrical contacts, especially machined contacts, it is applicable to contacts with other geometries and construction. In which case, the detail specification shall contain sufficient detail, given u

22、nder clause 4, to enable the test to be done. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any a

23、mendments) applies. IEC 60512-1-1, Connectors for electronic equipment Tests and measurements Part 1-1: General examination Test 1a: Visual examination 3 Preparations 3.1 Preparation of specimen The specimen shall consist of contact-wire assemblies. The length of cable protruding from the contact sh

24、all be at least 100 mm. Number of specimens: 10 specimens for each barrel size (5 for the minimum wire size and 5 for the maximum wire size) unless otherwise specified in the detail specification. The crimping tool(s) shall be those specified in the detail specification. If none are so specified, th

25、e contact manufacturers instructions for tooling shall be followed. In any case, full details of tooling shall be given in any reports supporting claims of conformance to this part of IEC 60512. Any preconditioning given in the detail specification shall be applied. BS EN 60512-16-7:200860512-16-7 I

26、EC:2008 5 3.2 Equipment A mounting collet shall be provided such that the contact may be rotated around its longitudinal axis to permit measurements at the specified points. The precision of the collet shall be such that the run-out of a steel gauge pin of 1,5 to 2,0 mm diameter measured 10 to 15 mm

27、 from the collet face shall not exceed 0,1 % of such distance. 4 Test procedure The contact shall be held in a collet in region H as shown in Figure 1, so that the contact can be rotated around the longitudinal axis to permit measurements at the specified points. A suitable test arrangement is shown

28、 in Figure 2. In the case of cylindrical contacts, readings (preferably with an indicator gauge) of the position of the contact shall be taken before and after crimping. The total excursion of the position when the contact is rotated is halved to give the deformation (or damage). Non-circular contac

29、ts shall be measured in a similar manner. The deformation (or damage) may be similarly calculated. MX YHIEC 1005/08 Key X Twice the male contact diameter. Also used for corresponding female contact OR If not circular, corresponding characteristic dimension of each contact. Y Mid point between end of

30、 crimp barrel, or end of contact, and beginning of crimp indentation M Measurement points for contact deformation H (Example of) Holding area NOTE This should correspond to the area in which the contact is intended to be held in use. Figure 1 Example of holding and measurement points BS EN 60512-16-

31、7:2008 6 60512-16-7 IEC:2008 Dial indicator 0,025 mm (0,001 in) Conductor Contact Super precision collet IEC 1006/08Figure 2 Typical test arrangement for deformation measurement 5 Measurements and requirements 5.1 Before testing Visual examination according to IEC 60512-1-1 shall be carried out. The

32、re shall be no defects that would impair the validity of the test. 5.2 After testing The requirements of the detail specification for deformation shall be met. Visual examination according to IEC 60512-1-1 shall be carried out. There shall be no defects, other than any found under 5.1, that would im

33、pair the normal functioning of the component. 6 Details to be specified When this test is required by the detail specification, the following details shall be specified. a) wire type and size; b) specification of crimping tool(s) to be used; c) area(s) of contact to be held by the mounting collet; N

34、OTE This should correspond to the housing or insert location point(s). d) points of measurement on the contact; if other than those given in 3.2; e) values of deformation permitted, for each point of measurement; f) number of specimens to be tested if different than specified in 3.1; g) any deviatio

35、n from the standard test method. BS EN 60512-16-7:200860512-16-7 IEC:2008 7 Bibliography IEC 60352-2, Solderless connections Part 2: Crimped connections General requirements, test methods and practical guidance _ BS EN 60512-16-7:2008This page deliberately left blankThis page deliberately left blank

36、BSI is the independent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter.British Standards Institution (BSI)raising standards worldwideBSI Group Headquarters389 Chiswick High R

37、oad London W4 4AL UKTel +44 (0)20 8996 9001Fax +44 (0)20 8996 Standards are updated by amendment or revision. Users of BritishStandards should make sure that they possess the latest amendments oreditions.It is the constant aim of BSI to improve the quality of our products andservices. We would be g

38、rateful if anyone finding an inaccuracy orambiguity while using this British Standard would inform the Secretary ofthe technical committee responsible, the identity of which can be foundon the inside front cover.Tel: +44 (0)20 8996 9000 Fax: +44 (0)20 8996 7400BSI offers members an individual updati

39、ng service called PLUS whichensures that subscribers automatically receive the latest editions ofstandards.Buying standardsOrders for all BSI, international and foreign standards publicationsshould be addressed to BSI Customer Services.Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001Email: You may

40、also buy directly using a debit/credit card from the BSI Shopon the website response to orders for international standards, it is BSI policy tosupply the BSI implementation of those that have been publishedas British Standards, unless otherwise requested.Information on standardsBSI provides a wide

41、range of information on national, European andinternational standards through its Library.Various BSI electronic information services are also available which givedetails on all its products and services. Contact the Information Centre. Tel: +44 (0)20 8996 7111 Fax: +44 (0)20 8996 7048 Email: Subscr

42、ibing members of BSI are kept up to date with standardsdevelopments and receive substantial discounts on the purchase priceof standards. For details of these and other benefits contact MembershipAdministration. Tel: +44 (0)20 8996 7002 Fax: +44 (0)20 8996 7001 Email: Information regarding online ac

43、cess to British Standards via BritishStandards Online can be found at information about BSI is available on the BSI website CopyrightCopyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of thepublications of the international standardization bodies. Except as permitt

44、ed under theCopyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrievalsystem or transmitted in any form or by any means electronic, photocopying, recording orotherwise without prior written permission from BSI. This does not preclude the free use, in the course of im

45、plementing the standard of necessarydetails such as symbols, and size, type or grade designations. If these details are to be used forany other purpose than implementation then the prior written permission of BSI must beobtained. Details and advice can be obtained from the Copyright & Licensing Manager.Tel: +44 (0)20 8996 7070 Email: WB9423_BSI_StandardColCov_noK_AW:BSI FRONT COVERS 5/9/08 12:55 Page 2

展开阅读全文
相关资源
猜你喜欢
  • BS ISO 11783-13-2011 Tractors and machinery for agriculture and forestry Serial control and communications data network File server《农业和林业用拖拉机及机械 串行控制和通信数据网 文件服务器》.pdf BS ISO 11783-13-2011 Tractors and machinery for agriculture and forestry Serial control and communications data network File server《农业和林业用拖拉机及机械 串行控制和通信数据网 文件服务器》.pdf
  • BS ISO 11783-14-2013 Tractors and machinery for agriculture and forestry Serial control and communications data network Sequence control《农业和林业用拖拉机及机械 系列控制和通信数据网 顺序控制》.pdf BS ISO 11783-14-2013 Tractors and machinery for agriculture and forestry Serial control and communications data network Sequence control《农业和林业用拖拉机及机械 系列控制和通信数据网 顺序控制》.pdf
  • BS ISO 11783-2-2012 Tractors and machinery for agriculture and forestry Serial control and communications data network Physical layer《农林用拖拉机和机械 系列控制和通信数据网 物理层》.pdf BS ISO 11783-2-2012 Tractors and machinery for agriculture and forestry Serial control and communications data network Physical layer《农林用拖拉机和机械 系列控制和通信数据网 物理层》.pdf
  • BS ISO 11783-3-2014 Tractors and machinery for agriculture and forestry Serial control and communications data network Data link layer《农业和林业用拖拉机和机械 串行控制和通信数据网 数据链层》.pdf BS ISO 11783-3-2014 Tractors and machinery for agriculture and forestry Serial control and communications data network Data link layer《农业和林业用拖拉机和机械 串行控制和通信数据网 数据链层》.pdf
  • BS ISO 11783-4-2011 Tractors and machinery for agriculture and forestry Serial control and communications data network Network layer《农林拖拉机和机械 串行控制和通信数据网 网络层》.pdf BS ISO 11783-4-2011 Tractors and machinery for agriculture and forestry Serial control and communications data network Network layer《农林拖拉机和机械 串行控制和通信数据网 网络层》.pdf
  • BS ISO 11783-5-2011 Tractors and machinery for agriculture and forestry Serial control and communications data network Network management《农业和林业用拖拉机及机械 串行控制和通信数据网 网络管理》.pdf BS ISO 11783-5-2011 Tractors and machinery for agriculture and forestry Serial control and communications data network Network management《农业和林业用拖拉机及机械 串行控制和通信数据网 网络管理》.pdf
  • BS ISO 11783-6-2014 en 4084 Tractors and machinery for agriculture and forestry Serial control and communications data network Virtual termina《农林用拖拉机和机械 系列控制和通信数据网 虚拟终端》.pdf BS ISO 11783-6-2014 en 4084 Tractors and machinery for agriculture and forestry Serial control and communications data network Virtual termina《农林用拖拉机和机械 系列控制和通信数据网 虚拟终端》.pdf
  • BS ISO 11783-7-2015 Tractors and machinery for agriculture and forestry Serial control and communications data network Implement messages application layer《农业和林业用牵引车和机械设备 串行控制和通信数据.pdf BS ISO 11783-7-2015 Tractors and machinery for agriculture and forestry Serial control and communications data network Implement messages application layer《农业和林业用牵引车和机械设备 串行控制和通信数据.pdf
  • BS ISO 11783-8-2006 Tractors and machinery for agriculture and forestry - Serial control and communications data network - Power train messages《农业和林业用拖拉机及机械 系列控制和通信数据网 动力传动系信息》.pdf BS ISO 11783-8-2006 Tractors and machinery for agriculture and forestry - Serial control and communications data network - Power train messages《农业和林业用拖拉机及机械 系列控制和通信数据网 动力传动系信息》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1