EN 60512-17-3-2010 en Connectors for electronic equipment - Tests and measurements - Part 17-3 Cable clamping tests - Test 17c Cable clamp resistance to cable pull (tensile)《电子设备连接.pdf

上传人:testyield361 文档编号:718272 上传时间:2019-01-04 格式:PDF 页数:10 大小:1.21MB
下载 相关 举报
EN 60512-17-3-2010 en Connectors for electronic equipment - Tests and measurements - Part 17-3 Cable clamping tests - Test 17c Cable clamp resistance to cable pull (tensile)《电子设备连接.pdf_第1页
第1页 / 共10页
EN 60512-17-3-2010 en Connectors for electronic equipment - Tests and measurements - Part 17-3 Cable clamping tests - Test 17c Cable clamp resistance to cable pull (tensile)《电子设备连接.pdf_第2页
第2页 / 共10页
EN 60512-17-3-2010 en Connectors for electronic equipment - Tests and measurements - Part 17-3 Cable clamping tests - Test 17c Cable clamp resistance to cable pull (tensile)《电子设备连接.pdf_第3页
第3页 / 共10页
EN 60512-17-3-2010 en Connectors for electronic equipment - Tests and measurements - Part 17-3 Cable clamping tests - Test 17c Cable clamp resistance to cable pull (tensile)《电子设备连接.pdf_第4页
第4页 / 共10页
EN 60512-17-3-2010 en Connectors for electronic equipment - Tests and measurements - Part 17-3 Cable clamping tests - Test 17c Cable clamp resistance to cable pull (tensile)《电子设备连接.pdf_第5页
第5页 / 共10页
点击查看更多>>
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationConnectors for electronic equipment Tests and measurementsPart 17-3: Cable clamping tests Test 17c: Cable clamp resistance to cable pull (tensile)BS EN 60512-17-3:2010National fo

2、rewordThis British Standard is the UK implementation of EN 60512-17-3:2010. It isidentical to IEC 60512-17-3:2010. This standard supersedes Test 17c from The UK participation in its preparation was entrusted to Technical CommitteeEPL/48, Electromechanical components and mechanical structures for ele

3、ctronic equipment.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2010ISBN 978 0 580 62163 5ICS 31.220.01Com

4、pliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy and Strategy Committee on 30 November 2010.Amendments issued since publicationDate Text affectedBRITISH STANDARDBS EN 60512-17-3:2010BS 5772-9:1

5、993, IEC 60512-9:1992, which will remain current until all the tests it contains have been revised.EUROPEAN STANDARD EN 60512-17-3 NORME EUROPENNE EUROPISCHE NORM September 2010 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europische

6、s Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60512-17-3:2010 E ICS 31.220.01 English version Connectors for electronic equipment

7、 - Tests and measurements - Part 17-3: Cable clamping tests - Test 17c: Cable clamp resistance to cable pull (tensile) (IEC 60512-17-3:2010) Connecteurs pour quipements lectroniques - Essais et mesures - Partie 17-3: Essais de maintien des cbles - Essai 17c: Rsistance de la pince de maintien des cbl

8、es au tirage (CEI 60512-17-3:2010) Steckverbinder fr elektronische Einrichtungen - Mess- und Prfverfahren - Teil 17-3: Prfungen der Kabelabfangung - Prfung 17c: Widerstandsfhigkeit der Kabelabfangung gegen axialen Zug (IEC 60512-17-3:2010) This European Standard was approved by CENELEC on 2010-09-01

9、. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtaine

10、d on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central

11、 Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembo

12、urg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 60512-17-3:2010EN 60512-17-3:2010 - 2 - Foreword The text of document 48B/2156/FDIS, future edition 1 of IEC 60512-17-3, prepared by SC 48B, Connectors, of IEC

13、 TC 48, Electromechanical components and mechanical structures for electronic equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60512-17-3 on 2010-09-01 Attention is drawn to the possibility that some of the elements of this document may be the subject of pa

14、tent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2011-06-01 latest dat

15、e by which the national standards conflicting with the EN have to be withdrawn (dow) 2013-09-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 60512-17-3:2010 was approved by CENELEC as a European Standard without any modification. _ BS EN 60512-1

16、7-3:2010- 3 - EN 60512-17-3:2010 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For

17、 undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60512-1-1 - Connectors for el

18、ectronic equipment - Tests and measurements - Part 1-1: General examination - Test 1a: Visual examination EN 60512-1-1 - BS EN 60512-17-3:2010 4 60512-17-3 IEC:2010 CONNECTORS FOR ELECTRONIC EQUIPMENT TESTS AND MEASUREMENTS Part 17-3: Cable clamping tests Test 17c: Cable clamp resistance to cable pu

19、ll (tensile) 1 Scope and object This part of IEC 60512, when required by the detail specification, is used for testing connectors within the scope of technical committee 48. It may also be used for similar devices when specified in a detail specification. The object of this standard is to detail a s

20、tandard test method to assess the ability of a cable-clamping device to prevent longitudinal movement of the cable/wire bundle. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For

21、undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60512-1-1, Connectors for electronic equipment Tests and measurements Part 1-1: General examination Test 1a: Visual examination 3 Preparation of the specimen The specimen shall consist of the sp

22、ecified cable/wire bundle fitted in the normal manner to its associated component or sub-assembly by means of the cable-clamping device. The specimen shall be prepared and mounted in accordance with the detail specification. 4 Test method This test shall be done by means of a suitable device to meas

23、ure and control the forces, e.g. a universal materials testing machine. With the specimen rigidly mounted in such an attitude that the cable/wire bundle is in a vertical position, a specified tensile force shall be applied axially to the free end of the cable/wire bundle. This force shall be increas

24、ed gradually at a rate not exceeding 20 N/s until the specified value is reached. The maximum value shall be maintained for 1 min, unless otherwise specified in the detail specification. 5 Final measurements The specimen shall be examined visually in accordance with IEC 60512-1-1, test 1a at the jun

25、ction of the cable/wire bundle and the clamping device and at the junction of the clamping device and the component or sub-assembly. BS EN 60512-17-3:201060512-17-3 IEC:2010 5 6 Requirements There shall be no damage such as would impair operation and the cable/wire bundle shall be displaced by not m

26、ore than the amount specified in the detail specification. 7 Details to be specified When this test is required by the detail specification, the following details shall be specified: a) preparation of the specimen and type of cable/wire bundle to be used; b) mounting of the specimen; c) force to be

27、applied; d) requirements for final measurements, e.g. maximum displacement of the cable/wire bundle; e) any deviation from the standard test method. _ BS EN 60512-17-3:2010This page deliberately left blankThis page deliberately left blankBSI is the independent national body responsible for preparing

28、 British Standardsand other standards-related publications, information and services. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter.British Standards Institution (BSI)raising standards worldwideBSI Group Headquarters389 Chiswick Hi

29、gh Road London W4 4AL UKTel +44 (0)20 8996 9001Fax +44 (0)20 8996 Standards are updated by amendment or revision. Users of British Stan-dards should make sure that they possess the latest amendments or editions.It is the constant aim of BSI to improve the quality of our products and serv-ices. We w

30、ould be grateful if anyone finding an inaccuracy or ambiguity whileusing this British Standard would inform the Secretary of the technical com-mittee responsible, the identity of which can be found on the inside frontcover.Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001BSI offers Members an indivi

31、dual updating service called PLUS which ensuresthat subscribers automatically receive the latest editions of standards.Tel: +44 (0)20 8996 7669 Fax: +44 (0)20 8996 7001Email: Buying standardsYou may buy PDF and hard copy versions of standards directly using acredit card from the BSI Shop on the webs

32、ite addition all orders for BSI, international and foreign standards publicationscan be addressed to BSI Customer Services.Tel: +44 (0)20 8996 9001 Fax: +44 (0)20 8996 7001Email: In response to orders for international standards, it is BSI policy tosupply the BSI implementation of those that have b

33、een publishedas British Standards, unless otherwise requested.Information on standardsBSI provides a wide range of information on national, Europeanand international standards through its Knowledge Centre.Tel: +44 (0)20 8996 7004 Fax: +44 (0)20 8996 7005Email: Various BSI electronic information serv

34、ices are also available whichgive details on all its products and services. Tel: +44 (0)20 8996 7111 Fax: +44 (0)20 8996 7048Email: BSI Subscribing Members are kept up to date with standardsdevelopments and receive substantial discounts on the purchase priceof standards. For details of these and oth

35、er benefits contact Membership Ad-ministration. Tel: +44 (0)20 8996 7002 Fax: +44 (0)20 8996 7001 Email: Information regarding online access to British Standards via BritishStandards Online can be found at information about BSI is available on the BSI website at www.bsi- subsists in all BSI public

36、ations. BSI also holds the copyright,in the UK, of the publications of the international standardization bodies. Ex-cept as permitted under the Copyright, Designs and Patents Act 1988 no ex-tract may be reproduced, stored in a retrieval system or transmitted in anyform or by any means electronic, ph

37、otocopying, recording or otherwise without prior written permission from BSI. This does not preclude the freeuse, in the course of implementing the standard of necessary details such assymbols, and size, type or grade designations. If these details are to be usedfor any other purpose than implementation then the prior written permissionof BSI must be obtained. Details and advice can be obtained from the Copy-right & Licensing Manager.Tel: +44 (0)20 8996 7070Email:

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1