EN 60598-2-22-1998 en Luminaires - Part 2-22 Particular Requirements Luminaires for Emergency Lighting (Incorporates Amendment A2 2008 Incorporating Corrigenda December 2005 and Oc.pdf

上传人:syndromehi216 文档编号:718395 上传时间:2019-01-04 格式:PDF 页数:32 大小:5.10MB
下载 相关 举报
EN 60598-2-22-1998 en Luminaires - Part 2-22 Particular Requirements Luminaires for Emergency Lighting (Incorporates Amendment A2 2008 Incorporating Corrigenda December 2005 and Oc.pdf_第1页
第1页 / 共32页
EN 60598-2-22-1998 en Luminaires - Part 2-22 Particular Requirements Luminaires for Emergency Lighting (Incorporates Amendment A2 2008 Incorporating Corrigenda December 2005 and Oc.pdf_第2页
第2页 / 共32页
EN 60598-2-22-1998 en Luminaires - Part 2-22 Particular Requirements Luminaires for Emergency Lighting (Incorporates Amendment A2 2008 Incorporating Corrigenda December 2005 and Oc.pdf_第3页
第3页 / 共32页
EN 60598-2-22-1998 en Luminaires - Part 2-22 Particular Requirements Luminaires for Emergency Lighting (Incorporates Amendment A2 2008 Incorporating Corrigenda December 2005 and Oc.pdf_第4页
第4页 / 共32页
EN 60598-2-22-1998 en Luminaires - Part 2-22 Particular Requirements Luminaires for Emergency Lighting (Incorporates Amendment A2 2008 Incorporating Corrigenda December 2005 and Oc.pdf_第5页
第5页 / 共32页
点击查看更多>>
资源描述

1、BRITISH STANDARDBS EN 60598-2-22:1998+A2:2008Incorporating corrigenda December 1999, December 2005, October 2007 andLuminaires Part 2-22: Particular requirements Luminaires for emergency lightingICS 29.140.40; 91.160.10g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g

2、54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g582010AugustNational forewordThis British Standard is the UK implementation of EN 60598-2-22:1998+A2:2008, incorporating corrigenda December 2005 and October 2007. It is derived from

3、IEC 60598-2-22:1997, incorporating amendment 2:2008. It supersedes BS EN 60598-2-22:1998+A1:2003 which will be withdrawn on 1 March 2011.The CENELEC common modifications have been implemented at the appropriate places in the text. The start and finish of each common modification is indicated in the

4、text by tags .The start and finish of text introduced or altered by amendment is indicated in the text by tags. Tags indicating changes to IEC text carry the number of the IEC amendment. For example, text altered by IEC amendment 1 is indicated by !“.The UK participation in its preparation was entru

5、sted by Technical Committee CPL/34/4, Luminaires, to Subcommittee CPL/34/4/2, Luminaires for emergency lighting.A list of organizations represented on this subcommittee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contrac

6、t. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.BS EN 60598-2-22:1998+A2:2008This British Standard was published under the authority of the Standards Committee and comes into effect on 15 March 1999 BSI 2010Amendme

7、nts/corrigenda issued since publicationAmd. No. Date Comments 10562Corrigendum No. 1December 1999 Change to date of withdrawal (dow) of conflicting national standards14393 20 June 2003 See national foreword16331Corrigendum No. 230 June 2006 Revision of Foreword, Annex ZA and Annex ZB17505Corrigendum

8、 No. 331 December 2007Revision of EN foreword30 September 2008Implementation of IEC amendment 2:2008 with CENELEC endorsement A2:2008, and alignment of BSI and CENELEC publication dates31 August 2010 Inclusion of IEC amendment 2:2008 that was left out of previous amendmentISBN 978 0 580 70987 6EN 60

9、598-2-22:1998+A2May 2008 Page 2BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)Foreword to amendment A2 The text of document 34D/883/FDIS, future amendment 2 to IEC 60598-2-22:1997, prepared by SC 34D, Luminaires, of IEC TC 34, Lamps and related equipment, was submitted to the IEC-CENELEC

10、 parallel vote and was approved by CENELEC as amendment A2 to EN 60598-2-22:1998 on 2008-03-01. The following dates were fixed: latest date by which the amendment has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2008-12-01 latest date b

11、y which the national standards conflicting with the amendment have to be withdrawn (dow) 2011-03-01 _ Endorsement notice The text of amendment 2:2008 to the International Standard IEC 60958-2-22:1997 was approved by CENELEC as an amendment to the European Standard without any modification. _ Page 3B

12、S EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)56688101313131313131515151517181820222425262818Page 4BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)Page 5BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)Page 6BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)

13、Page 7BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)The provisions of section 3 of IEC 60598-1 shall apply together with the requirements of 22.5.1 to 22.5.20 below. #$NOTE The information relating to correct lamp replacement may include the number, type, rated voltage and rated wattage

14、, etc. Luminaires containing non-replaceable lamp(s) need not meet this subclause. #$NOTE Luminaires containing non-replaceable battery need not meet this subclause. For luminaires with non-replaceable batteries, such information shall be provided in a label to be observed during installation, accor

15、ding to 3.2b) of IEC 60598-1. #$Page 8BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)22.5.10 In the instruction leaflet supplied with the self-contained emergency luminaire, the manufacturer shall state that the replacement of the battery or of the whole luminaire (if having non-replacea

16、ble lamp(s) and/or battery) is needed when they no longer meet their rated duration of operation. #$22.5.13 Not in use. # $“22.5.19 In the instruction leaflet supplied with the luminaire, the manufacturer shall specify if the lamp(s) and/or the battery is/are non-replaceable. #$22.5.20 Compliance wi

17、th the requirements of 22.5.1 to 22.5.19 is checked by inspection.Page 9BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)Page 10BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)Where an electrical light source indicator is used, it shall comply with the colour requirements of IEC

18、 60073 and be green. When a single indicator provides dual functions, either red or greenis acceptable. #$Page 11BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)Page 12BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)Page 13BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008

19、 (E)Page 14BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)For emergency lighting luminaires containing a battery, any part or component of the luminaire that it is possible to move and can come into possible contact with the battery, or the leads from the charger to the battery or charge

20、r circuit, shall be compliant with the glow wire test as stated in subclause 13.3.2 of IEC 60598-1 but at a test temperature of 850 C. Other parts of the luminaire which do not perform this protective function do not need to be subjected to this test at 850 C. Compliance is checked by the test in su

21、bclause 13.3.2 of IEC 60598-1. #$Page 15BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)Page 16BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)Page 17BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)Page 18BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)Pag

22、e 19BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)Page 20BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)A.8 The battery of a self-contained emergency luminaire is not a user serviceable item and shall only be replaced by a competent person. #$Page 21BS EN 60598-2-22:1998+A2:

23、2008EN 60598-2-22:1998+A2:2008 (E)E with non-replaceable lamp(s) and/or battery.Page 22BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)# $Page 23BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)Page 24BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)Page 25BS EN 60598-

24、2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)Page 26BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)Page 27BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)Annex ZB (informative) A-deviations A-deviation: National deviation due to regulations, the alteration of which is for th

25、e time being outside the competence of the CENELEC member. This European Standard falls under Directive 2006/95/EC. NOTE (from CEN/CENELEC IR Part 2:2006, 2.17) Where standards fall under EC Directives, it is the view of the Commission of the European Communities (OJ No C 59, 1982-03-09) that the ef

26、fect of the decision of the Court of Justice in case 815/79 Cremonini/Vrankovich (European Court Reports 1980, p. 3583) is that compliance with A-deviations is no longer mandatory and that the free movement of products complying with such a standard should not be restricted except under the safeguar

27、d procedure provided for in the relevant Directive. A-deviations in an EFTA-country are valid instead of the relevant provisions of the European Standard in that country until they have been removed. Clause Deviation 22.5.18 and 22.10.1 France (Arrt relatif la scurit dans les tablissements recevant

28、du public Article EL 10 1). In premises open to the public, electrical installations shall have only permanent fittings. 22.6.6 and 22.3.7 France (Rglement de scurit contre les risques dincendie et de panique dans les tablissements recevant du public - Article EC 5 3). The lamps for general purpose

29、lighting and the lamps for emergency lighting shall be inserted in separate luminaries. 22.15 France (Rglement de scurit contre les risques dincendie et de panique dans les tablissements recevant du public - Article EC 5 2). The external parts of fixed or suspended luminaires shall also withstand th

30、e glow wire test at 850 C. 22.16.2 and 22.16.3 France (Rglement de scurit contre les risques dincendie et de panique dans les tablissements recevant du public - Articles EC 9 et EC 10). Characteristics of the products are only based on the rated lumen output and therefore photometric characteristics of the luminaire may not to be provided, or checked. _ Page 28BS EN 60598-2-22:1998+A2:2008EN 60598-2-22:1998+A2:2008 (E)