1、BSI Standards PublicationThyristor valves for high voltage direct current (HVDC)power transmissionPart 1: Electrical testingBS EN 60700-1:2015National forewordThis British Standard is the UK implementation of EN 60700-1:2015. It isidentical to IEC 60700-1:2015. It supersedes BS EN 60700-1:1998+A2:20
2、08,which will be withdrawn on 1 September 2018.The UK participation in its preparation was entrusted to TechnicalCommittee PEL/22, Power electronics.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the n
3、ecessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2015.Published by BSI Standards Limited 2015ISBN 978 0 580 81025 1ICS 29.200; 31.080.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British S
4、tandard was published under the authority of theStandards Policy and Strategy Committee on 31 October 2015.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 60700-1:2015EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 60700-1 September 2015 ICS 29.200 Supersed
5、es EN 60700-1:1998 English Version Thyristor valves for high voltage direct current (HVDC) power transmission - Part 1: Electrical testing (IEC 60700-1:2015) Valves thyristors pour le transport dnergie en courant continu haute tension (CCHT) - Partie 1: Essais lectriques (IEC 60700-1:2015) Thyristor
6、ventile fr Hochspannungsgleichstrom-Energiebertragung (HG) - Teil 1: Elektrische Prfung (IEC 60700-1:2015) This European Standard was approved by CENELEC on 2015-09-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this Europe
7、an Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versi
8、ons (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical comm
9、ittees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia,
10、Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CENELEC
11、All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 60700-1:2015 E BS EN 60700-1:2015EN 60700-1:2015 2 European foreword The text of document 22F/341/CDV, future edition 2 of IEC 60700-1, prepared by SC 22F “Power electronics for electrical tra
12、nsmission and distribution systems” of IEC/TC 22 “Power electronic systems and equipment” was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 60700-1:2015. The following dates are fixed: latest date by which the document has to be implemented at national level by publication
13、 of an identical national standard or by endorsement (dop) 2016-06-01 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2018-09-01 This document supersedes EN 60700-1:1998. Attention is drawn to the possibility that some of the elements of this docu
14、ment may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 60700-1:2015 was approved by CENELEC as a European Standard without any modification. BS EN 60700-1:
15、2015EN 60700-1:2015 3 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only
16、 the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on t
17、he latest versions of the European Standards listed in this annex is available here: www.cenelec.eu Publication Year Title EN/HD Year IEC 60060 Series High-voltage test techniques EN 60060 Series IEC 60060-1 - High-voltage test techniques - Part 1: General definitions and test requirements EN 60060-
18、1 - IEC 60071-1 - Insulation co-ordination - Part 1: Definitions, principles and rules EN 60071-1 - IEC 60099 Series Surge arresters EN 60099 Series IEC 60270 - High-voltage test techniques - Partial discharge measurements EN 60270 - IEC 61803 +A1 1999 2010 Determination of power losses in high-volt
19、age direct current (HVDC) converter stations EN 61803 +A1 1999 2010 ISO/IEC Guide 25 1)- General requirements for the competence of calibration and testing laboratories - - 1)Withdrawn publication. BS EN 60700-1:2015 2 IEC 60700-1:2015 IEC 2015 CONTENTS FOREWORD . 5 1 Scope 7 2 Normative references
20、. 7 3 Terms and definitions. 7 3.1 Insulation co-ordination terms 8 3.2 Valve construction terms . 9 3.3 Terms related to type tests 10 3.4 Terms related to production tests 10 4 General requirements 10 4.1 Guidelines for the performance of type tests 10 4.1.1 Evidence in lieu 10 4.1.2 Test object .
21、 10 4.1.3 Sequence of tests 10 4.1.4 Test procedures . 11 4.1.5 Ambient temperature for testing . 11 4.1.6 Frequency for testing . 11 4.1.7 Test reports . 11 4.2 Atmospheric correction 11 4.3 Treatment of redundancy . 11 4.3.1 Dielectric tests . 11 4.3.2 Operational tests 11 4.4 Criteria for success
22、ful type testing . 12 4.4.1 General . 12 4.4.2 Criteria applicable to thyristor levels . 12 4.4.3 Criteria applicable to the valve as a whole 13 5 List of type tests 13 6 Dielectric tests on valve support . 14 6.1 Purpose of tests 14 6.2 Test object 14 6.3 Test requirements . 15 6.3.1 General . 15 6
23、.3.2 Valve support d.c. voltage test . 15 6.3.3 Valve support a.c. voltage test . 15 6.3.4 Valve support switching impulse test 16 6.3.5 Valve support lightning impulse test . 16 7 Dielectric tests for multiple valve units (MVU) . 16 7.1 Purpose of tests 16 7.2 Test object 16 7.3 Test requirements .
24、 17 7.3.1 MVU d.c. voltage test to earth 17 7.3.2 MVU a.c. voltage test . 18 7.3.3 MVU switching impulse test 18 7.3.4 MVU lightning impulse test . 19 8 Dielectric tests between valve terminals . 20 8.1 Purpose of tests 20 8.2 Test object 20 BS EN 60700-1:2015IEC 60700-1:2015 IEC 2015 3 8.3 Test req
25、uirements . 20 8.3.1 Valve d.c. voltage test 20 8.3.2 Valve a.c. voltage test 21 8.3.3 Valve impulse tests (general) . 22 8.3.4 Valve switching impulse test . 23 8.3.5 Valve lightning impulse test 23 8.3.6 Valve steep front impulse test 23 8.4 Valve non-periodic firing test . 24 8.4.1 Purpose of tes
26、t 24 8.4.2 Test object . 24 8.4.3 Test requirements 24 9 Periodic firing and extinction tests 25 9.1 Purpose of tests 25 9.2 Test object 26 9.3 Test requirements . 26 9.3.1 General . 26 9.3.2 Maximum continuous operating duty tests 27 9.3.3 Maximum temporary operating duty test ( = 90) . 28 9.3.4 Mi
27、nimum a.c. voltage tests . 29 9.3.5 Temporary undervoltage test 30 9.3.6 Intermittent direct current tests . 31 10 Tests with transient forward voltage during the recovery period 31 10.1 Purpose of tests 31 10.2 Test object 31 10.3 Test requirements . 31 11 Valve fault current tests . 33 11.1 Purpos
28、e of tests 33 11.2 Test object 33 11.3 Test requirements . 33 11.3.1 General . 33 11.3.2 One-loop fault current test with re-applied forward voltage 34 11.3.3 Multiple-loop fault current test without re-applied forward voltage . 35 12 Tests for valve insensitivity to electromagnetic disturbance 35 1
29、2.1 Purpose of tests 35 12.2 Test object 36 12.3 Test requirements . 36 12.3.1 General . 36 12.3.2 Approach one 36 12.3.3 Approach two . 36 12.3.4 Acceptance criteria 37 13 Testing of special features and fault tolerance 37 13.1 Purpose of tests 37 13.1.1 General . 37 13.1.2 Circuits to facilitate t
30、he proper control, protection and monitoring of the valve 37 13.1.3 Features included in the valve to provide fault tolerance . 37 13.2 Test object 37 13.3 Test requirements . 38 14 Production tests . 38 BS EN 60700-1:2015 4 IEC 60700-1:2015 IEC 2015 14.1 General . 38 14.2 Purpose of tests 38 14.3 T
31、est object 38 14.4 Test requirements . 38 14.5 Routine test minimum requirements 38 14.5.1 Visual inspection 38 14.5.2 Connection check 39 14.5.3 Voltage-grading circuit check . 39 14.5.4 Voltage withstand check . 39 14.5.5 Partial discharge tests 39 14.5.6 Check of auxiliaries 39 14.5.7 Firing chec
32、k . 39 14.5.8 Pressure test . 39 15 Method for loss determination 39 16 Presentation of type test results . 39 Annex A (normative) Test safety factors . 40 A.1 General . 40 A.2 Test safety factors for dielectric tests 40 A.2.1 Impulse tests . 40 A.2.2 AC and d.c. temporary and long-term voltage test
33、s . 43 A.3 Test safety factors for operational tests . 43 Annex B (normative) Partial discharge measurements 44 B.1 Measurement of partial discharge 44 B.2 Partial discharge during a.c. tests 44 B.3 Partial discharge during d.c. tests 44 B.4 Composite a.c. plus d.c. voltage stress 45 Figure 1 Steep
34、front impulse test voltage 8 Table 1 Thyristor level faults permitted during type tests . 13 Table 2 List of type tests 14 BS EN 60700-1:2015IEC 60700-1:2015 IEC 2015 5 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ THYRISTOR VALVES FOR HIGH VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION Part 1: Elec
35、trical testing FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standar
36、dization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation
37、 is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with th
38、e International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects
39、 since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical con
40、tent of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possi
41、ble in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformi
42、ty assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services carried out by independent certification bodies. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its director
43、s, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising ou
44、t of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn
45、to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC 60700-1 has been prepared by subcommittee 22F: Power electronics for electrical transm
46、ission and distribution systems, of IEC technical committee 22: Power electronic systems and equipment. This second edition cancels and replaces the first edition published in 1998, its Amendment 1:2003 and its Amendment 2: 2008. This edition constitutes a technical revision. This edition includes t
47、he following significant technical changes with respect to the previous edition. a) Definitions of terms “redundant thyristor levels”, “thyristor level”, “valve section” have been changed for clarification. b) The notes were added to test requirements of dielectric d.c. voltage tests for valve suppo
48、rt, MVU, valve, specifying that before repeating the test with opposite polarity, the tested BS EN 60700-1:2015 6 IEC 60700-1:2015 IEC 2015 object may be short-circuited and earthed for several hours. The same procedure may be followed at the end of the d.c. voltage test. c) Table 1 on thyristor lev
49、el faults permitted during type tests was supplemented. d) The alternative MVU dielectric test method was added. e) It was specified that production tests may include routine tests as well as sample tests. f) It was added into test requirements for periodic firing and extinction tests that a scaling factor for tests shall be applied when testing with valve sections. The text of this standard is based on the following documents: CDV Report on voting 22F/341/CDV 22F/351A/RVC Full information on the vo