1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationCable networks for television signals, sound signals and interactive servicesPart 7-3: Hybrid fibre coax outside plant status monitoring Power supply to transponder interface bus
2、 (PSTIB)BS EN 60728-7-3:2009National forewordThis British Standard is the UK implementation of EN 60728-7-3:2009. It isidentical to IEC 60728-7-3:2009. It supersedes BS EN 60728-7-3:2005 whichis withdrawn.The UK participation in its preparation was entrusted to Technical CommitteeEPL/100, Audio, vid
3、eo and multimedia systems and equipment.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2010ISBN 978 0 580 6
4、1961 8ICS 33.040.01; 33.160.01Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy and Strategy Committee on 30 April 2010.Amendments issued since publicationAmd. No. Date Text affectedBRITISH S
5、TANDARDBS EN 60728-7-3:2009EUROPEAN STANDARD EN 60728-7-3 NORME EUROPENNE EUROPISCHE NORM December 2009 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: Avenue Marnix
6、17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60728-7-3:2009 E ICS 33.040; 33.160 Supersedes EN 60728-7-3:2005English version Cable networks for television signals, sound signals and interactive servic
7、es - Part 7-3: Hybrid fibre coax outside plant status monitoring - Power supply to transponder interface bus (PSTIB) (IEC 60728-7-3:2009) Rseaux de distribution par cbles pour signaux de tlvision, signaux de radiodiffusion sonore et services interactifs - Partie 7-3: Surveillance de ltat des install
8、ations extrieures des rseaux hybrides fibre optique et cble coaxial - Alimentation du bus dinterface du rpteur (CEI 60728-7-3:2009) Kabelnetze fr Fernsehsignale, Tonsignale und interaktive Dienste - Teil 7-3: Zustandsberwachung Hybrid-Faser-Koax-Netze (HFC) - Schnittstellenbus von Fernspeise-Stromve
9、rsorgung zu Transponder (PSTIB)(IEC 60728-7-3:2009) This European Standard was approved by CENELEC on 2009-11-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without a
10、ny alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language ma
11、de by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark,
12、Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 60728-7-3:2009EN 60728-7-3:2009 - 2 - Foreword The text
13、of document 100/1464/CDV, future edition 2 of IEC 60728-7-3, prepared by technical area 5: Cable networks for television signals, sound signals and interactive services, of IEC TC 100, Audio, video and multimedia systems and equipment, was submitted to the IEC-CENELEC parallel vote and was approved
14、by CENELEC as EN 60728-7-3 on 2009-11-01. This European Standard supersedes EN 60728-7-3:2005. EN 60728-7-3:2009 includes the following significant technical changes with respect to EN 60728-7-3:2005: all changes from standard ANSI/SCTE 25-3 v1.0 to standard ANSI/SCTE 25-3 v1.1 (2005) have been take
15、n into account in EN 60728-7-3:2009; Clause 7 is based on standard ANSI/SCTE 110 (2005); addition of informative Annex A concerning hybrid management sub-layer. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national
16、 standard or by endorsement (dop) 2010-08-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2012-11-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 60728-7-3:2009 was approved by CENELEC as a Europ
17、ean Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60728-7-1 NOTE Harmonized as EN 60728-7-1:2005 (not modified). IEC 60728-7-2 NOTE Harmonized as EN 60728-7-2:2005 (not modified). IEC 60728-7-3 NOTE
18、 Harmonized as EN 60728-7-3:2005 (not modified). _ BS EN 60728-7-3:2009- 3 - EN 60728-7-3:2009 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this docum
19、ent. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publi
20、cation Year Title EN/HD Year IEC 60603-7 -1)Connectors for electronic equipment - Part 7: Detail specification for 8-way, unshielded, free and fixed connectors EN 60603-7 20092)1)Undated reference. 2)Valid edition at date of issue. BS EN 60728-7-3:2009 2 60728-7-3 IEC:2009(E) CONTENTS INTRODUCTION.7
21、 1 Scope.8 2 Normative references .9 3 Terms, definitions and abbreviations 9 3.1 Terms and definitions 9 3.2 Abbreviations 10 4 Reference architecture forward and return channel specifications 10 5 Power supply to transponder interface bus specification overview 11 5.1 General .11 5.2 Interface com
22、pliance .11 5.3 Implementation compliance .11 5.4 Revision control 12 6 Power supply to transponder interface bus Physical layer specification .12 6.1 Interface requirements 12 6.1.1 Connector type 12 6.1.2 Communications interface .12 6.1.3 Connector signals12 6.1.4 Transponder power12 6.1.5 Line b
23、alance13 6.1.6 Cable length 13 6.1.7 Data encoding .13 6.1.8 Bit rate 13 6.1.9 Duplex.13 6.1.10 Method of communications 13 6.1.11 Indicators 13 6.2 Interface diagram 14 7 Alternative power supply to transponder interface bus Physical layer specification .15 7.1 Introduction to alternative15 7.2 Int
24、erface requirements 15 7.2.1 Connector type 15 7.2.2 Communications interface .15 7.2.3 Connector signals15 7.2.4 Transponder power15 7.2.5 Line balance16 7.2.6 Cable length 16 7.2.7 Data encoding .16 7.2.8 Bit rate 16 7.2.9 Duplex.16 7.2.10 Method of communication16 7.2.11 Indicators 17 7.3 Interfa
25、ce diagram 17 8 Power supply to transponder interface bus Data link layer specification.18 8.1 DLL packet structure .18 BS EN 60728-7-3:200960728-7-3 IEC:2009(E) 3 8.1.1 General .18 8.1.2 Start 18 8.1.3 Destination Address 18 8.1.4 Source Address.19 8.1.5 Identification19 8.1.6 Datagram 19 8.1.7 End
26、 .19 8.1.8 Checksum .19 8.2 DLE sequence.19 8.3 Interface timing .20 8.3.1 Message synchronization and interaction 20 8.3.2 Transmission timing requirements .21 8.4 DLL datagrams22 8.4.1 Structure .22 8.4.2 Resolution versus accuracy.23 8.4.3 DLL datagram types 23 Annex A (informative) HMS specifica
27、tion documents37 Bibliography38 Figure 1 Reference architecture diagram .11 Figure 2 Sample PSTIB RS-485 interface 14 Figure 3 Sample PSTIB RS-485 interface 17 Figure 4 DLL packet structure18 Figure 5 PSTIB data and timing diagram21 Figure 6 DLL datagram structure22 Figure 7 Battery string naming co
28、nventions33 Table 1 Transponder type classifications .8 Table 2 RJ-45 Connector pin assignment.12 Table 3 Sample PSTIB RS-485 interface Reference signals14 Table 4 RJ-45 Connector pin assignment.15 Table 5 Sample PSTIB RS-485 interface Reference signals17 Table 6 Generic DLL packet structure 18 Tabl
29、e 7 Reserved destination address ranges19 Table 8 PSTIB timing specifications .21 Table 9 Generic DLL datagram structure22 Table 10 DLL datagrams24 Table 11 Command: Get_Configuration datagram24 Table 12 Response: Get_Configuration datagram 25 Table 13 Response: Get_Configuration datagram variable b
30、inding (general)25 Table 14 Response: Get_Configuration datagram variable binding (power supply).26 Table 15 Response: Get_Configuration datagramavariable binding (generator) .29 Table 16 Command: Get_Power_Supply_Data datagram .30 Table 17 Response: Get_Power_Supply_Data datagram .30 Table 18 Respo
31、nse: Get_Power_Supply_Data datagram variable binding30 BS EN 60728-7-3:2009 4 60728-7-3 IEC:2009(E) Table 19 Command: Power_Supply_Control datagram.33 Table 20 Command: Get_Generator_Data datagram33 Table 21 Response: Get_Generator_Data datagram 34 Table 22 Response: Get_Generator_Data Datagram vari
32、able binding 34 Table 23 Command: Generator_Control datagram .35 Table 24 Response: Invalid_Request datagram .35 Table 25 Response: Request_Processed datagram .36 Table A.1 HMS document family 37 BS EN 60728-7-3:200960728-7-3 IEC:2009(E) 7 INTRODUCTION Standards of the IEC 60728 series deal with cab
33、le networks including equipment and associ-ated methods of measurement for headend reception, processing and distribution of television signals, sound signals and their associated data signals and for processing, interfacing and transmitting all kinds of signals for interactive services using all ap
34、plicable transmission me-dia. This includes CATV1-networks; MATV-networks and SMATV-networks; individual receiving networks; and all kinds of equipment, systems and installations installed in such networks. The extent of this standardization work is from the antennas and/or special signal source in-
35、puts to the head-end or other interface points to the network up to the terminal input. The standardization of any user terminals (i.e. tuners, receivers, decoders, multimedia termi-nals, etc.) as well as of any coaxial, balanced and optical cables and accessories thereof is excluded. The following
36、differences exist in some countries: The Japanese de facto standard (NCTEA S-006) concerning requirements for the HFC out-side plant management, which was published in 1995, has already been available in Japan. The purpose of this standard is to support the design and implementation of interoperable
37、 management systems for HFC cable networks used in Japan. _ 1This word encompasses the HFC networks used nowadays to provide telecommunications services, voice, data, audio and video both broadcast and narrowcast.BS EN 60728-7-3:2009 8 60728-7-3 IEC:2009(E) CABLE NETWORKS FOR TELEVISION SIGNALS, SOU
38、ND SIGNALS AND INTERACTIVE SERVICES Part 7-3: Hybrid fibre coax outside plant status monitoring Power supply to transponder interface bus (PSTIB) 1 Scope This part of IEC 60728 specifies requirements for the Hybrid Fibre Coax (HFC) Outside Plant (OSP) Power Supplies (PS). This standard is part of a
39、series developed to support the design and implementation of interoperable management systems for evolving HFC cable networks. The purpose of the standards is to support the design and implementation of interoperable management systems for evolving HFC cable networks. The Power Supply to Transponder
40、 In-terface Bus (PSTIB) specification describes the physical (PHY) interface and related messag-ing and protocols implemented at the Data Link Layer (DLL), layers 1 and 2 respectively in the 7-layer ISO-OSI reference model, that support communications between compliant trans-ponders and the managed
41、OSP power supplies and other related power equipment to which they interface. This standard describes the PSTIB PHY and DLL layer requirements and protocols that shall be implemented to support reliable communications between all type 2 and type 3 compliant OSP transponders on the HFC plant and mana
42、ged OSP power supplies and related hardware. Any exceptions to compliance with this standard will be specifically noted as necessary. Transponder type classifications referenced within the HMS series of standards are defined in Table 1. Table 1 Transponder type classifications Type Description Appli
43、cation Type 0 Refers to legacy transponder equip-ment which is incapable of supporting the specifications This transponder interfaces with legacy network equipment through proprietary means. This transponder could be managed through the same management applications as the other types through proxies
44、 or other means at the head-end. Type 1 Refers to stand-alone transponder equipment (legacy or new), which can be upgraded to support the specifica-tions This transponder interfaces with legacy network equipment through proprietary means. Type 1 is a standards-compliant transponder (either manufactu
45、red to the standard or upgraded) that con-nects to legacy network equipment via a proprietary interface. Type 2 Refers to a stand-alone, compliant transponder This transponder interfaces with network equipment designed to support the electrical and physical specifications defined in the standards. I
46、t can be factory or field-installed. Its RF connection is independent of the monitored NE. Type 3 Refers to a stand-alone or embedded, compliant transponder This transponder interfaces with network equipment designed to support the electrical specifications de-fined in the standards. It may or may n
47、ot support the physical specifications defined in the standards. It can be factory-installed. It may or may not be field-installed. Its RF connection is through the monitored NE. BS EN 60728-7-3:200960728-7-3 IEC:2009(E) 9 A list of documents in the HMS specifications family is provided in informati
48、ve Annex A. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60603-7, C
49、onnectors for electronic equipment Part 7: Detail specification for 8-way, un-shielded, free and fixed connectors 3 Terms, definitions and abbreviations 3.1 Terms and definitions For the purposes of this document, the following definitions apply. 3.1.1 data link layer DLL layer 2 in the Open System Interconnection (OSI) architecture; the layer that provides ser-vic