1、BRITISH STANDARDBS EN 61000-6-3:2007Electromagnetic compatibility (EMC) Part 6-3: Generic standards Emission standard for residential, commercial and light-industrial environments ICS 33.100.10g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g
2、40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58+A :20111Incorporating corrigendumAugust 2012National forewordThis British Standard is the UK implementation of EN 61000-6-3:2007+A1:2011, incorporating corrigendum August 2012. It is identical to IEC 61000-
3、6-3:2006, incorporating amendment 1:2010. It supersedes BS EN 61000-6-3:2007, which will be withdrawn on 12 January 2014.The start and finish of text introduced or altered by amendment is indicated in the text by tags. Tags indicating changes to IEC text carry the number of the IEC amendment. For ex
4、ample, text altered by IEC amendment 1 is indicated by !“.The UK participation in its preparation was entrusted by Technical Committee GEL/210, EMC Policy committee, to Subcommittee GEL/210/12, EMC basic, generic and low frequency phenomena Standardization.A list of organizations represented on this
5、 subcommittee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.BS EN 61000-6-3:2007+A
6、1:2011This British Standard was published under the authority of the Standards Policy and Strategy Committee on 28 February 2007 The British Standards Institution 2012. Published by BSI Standards Limited 2012Amendments/corrigenda issued since publicationDate Comments 30 June 2011 Implementation of I
7、EC amendment 1:2010, with CENELEC endorsement A1:2011.31 October 2012 Implementation of CENELEC corrigendum August 2012: Replaced date of withdrawal in National and EN forewords.ISBN 978 0 580 80428 1EUROPEAN STANDARD EN 61000-6-3:2007+A1 NORME EUROPENNE EUROPISCHE NORM March 2011 CENELEC European C
8、ommittee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: 0 Brussels 0Avenue Marnix 17, B - 10 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENEL
9、EC members. Ref. No. EN 61000-6-3:2007 E ICS 33.100.10 English version Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments (IEC 61000-6-3:2006) Compatibilit lectromagntique (CEM) - Partie 6-3: Normes gnri
10、ques - Norme sur lmission pour les environnements rsidentiels, commerciaux et de lindustrie lgre (CEI 61000-6-3:2006) Elektromagnetische Vertrglichkeit (EMV) - Teil 6-3: Fachgrundnormen - Straussendung fr Wohnbereich, Geschfts- und Gewerbebereiche sowie Kleinbetriebe (IEC 61000-6-3:2006) This Europe
11、an Standard was approved by CENELEC on 2006-12-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
12、concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member
13、into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ir
14、eland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Foreword The text of document CISPR/H/121/FDIS, future edition 2 of IEC 61000-6-3, prepared by CISPR SC H, Limits for the pro
15、tection of radio services, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61000-6-3 on 2006-12-01. This European Standard supersedes EN 61000-6-3:2001 + A11:2004. The major changes in EN 61000-6-3:2007 are the inclusion of a clause on tests for equipment in series p
16、roduction, a new clause on measurement uncertainty and the inclusion of requirements on dc power ports and telecommunications ports. The informative annex has been deleted. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identi
17、cal national standard or by endorsement (dop) 2007-09-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2009-12-01 This European Standard has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Associat
18、ion and covers essential requirements of EC Directives EMC (89/336/EEC), EMC (2004/108/EC) and RTTED (1999/5/EC). See Annex ZZ. Annexes ZA and ZZ have been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61000-6-3:2006 was approved by CENELEC as a European Standard
19、without any modification. _ Foreword to amendment A1 The text of document CISPR/H/206/FDIS, future amendment 1 to IEC 61000-6-3:2007, prepared by CISPR SC H, Limits for the protection of radio services, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as amendment A1 to EN
20、61000-6-3:2007 on 2011-01-01. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The following dates were fixed: latest date by which the am
21、endment has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2011-10-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2014-01- Annex ZA has been added by CENELEC. _ Endorsement notice The tex
22、t of amendment 1:2010 to the International Standard IEC 61000-6-3:2007 was approved by CENELEC as an amendment to the European Standard without any modification. _ 2 BS EN 61000-6-3:2007+A1:2011EN 61000-6-3:2007+A1:2011 (E)12CONTENTS INTRODUCTION.4 1 Scope and object5 2 Normative references .6 3 7 4
23、 Conditions during testing 9 5 Product documentation .9 6 Applicability10 7 Emission requirements .10 Measurement uncertainty10 Annex ZA (normative) Normative references to international publications with their corresponding European publications18 Annex ZZ (informative) Coverage of Essential Requir
24、ements of EC Directives Bibliography .17 Figure 1 Examples of ports 7 Table 1 Emission 1 Terms, definitions and abbreviations Application of limits in tests for conformity of equipment in series production Compliance with this standard Emission test requirements 8 91011 .121110 Enclosure port Table
25、2 g16 Emission g16 Low voltage AC mains port 1 .Table 3 Emission DC power port 1 Table 4 Emission Telecommunications/network port 1 3 BS EN 61000-6-3:2007+A1:2011EN 61000-6-3:2007+A1:2011 (E)202456! “! “! “! “! “! “! “! “! “4INTRODUCTION IEC 61000 is published in separate parts according to the foll
26、owing structure: Part 1: General General considerations (introduction, fundamental principles) Definitions, terminology Part 2: Environment Description of the environment Classification of the environment Compatibility levels Part 3: Limits Emission limits Immunity limits (insofar as they do not fal
27、l under the responsibility of the product committees) Part 4: Testing and measurement techniques Measurement techniques Testing techniques Part 5: Installation and mitigation guidelines Installation guidelines Mitigation methods and devices Part 6: Generic standards Part 9: Miscellaneous Each part i
28、s further subdivided into several parts published either as International Standards or technical reports/specifications, some of which have already been published as sections. Others will be published with the part number followed by a dash and a second number identifying the subdivision (example: 6
29、1000-6-1). 4 BS EN 61000-6-3:2007+A1:2011EN 61000-6-3:2007+A1:2011 (E)ELECTROMAGNETIC COMPATIBILITY (EMC) Part 6-3: Generic standards Emission standard for residential, commercial and light-industrial environments 1 Scope and object This part of IEC 61000 for EMC emission requirements applies to ele
30、ctrical and electronic apparatus intended for use in residential, commercial and light-industrial environments. Emission requirements in the frequency range 0 Hz to 400 GHz are covered. No measurement needs to be performed at frequencies where no requirement is specified. This generic EMC emission s
31、tandard is applicable if no relevant dedicated product or product-family EMC emission standard exists. This standard applies to apparatus intended to be directly connected to a low-voltage public mains network or connected to a dedicated DC source, which is intended to interface between the apparatu
32、s and the low-voltage public mains network. This standard applies also to apparatus which is battery operated or is powered by a non-public, but non-industrial, low-voltage power distribution system if this apparatus is intended to be used in the locations described below. The environments encompass
33、ed by this standard are residential, commercial and light-industrial locations, both indoor and outdoor. The following list, although not comprehensive, gives an indication of locations that are included: residential properties, for example houses, apartments; retail outlets, for example shops, supe
34、rmarkets; business premises, for example offices, banks; areas of public entertainment, for example cinemas, public bars, dance halls; outdoor locations, for example petrol stations, car parks, amusement and sports centres; light-industrial locations, for example workshops, laboratories, service cen
35、tres. Locations that are characterised by being supplied directly at low voltage from the public mains network are considered to be residential, commercial or light-industrial. The object of this standard is to define the emission test requirements for apparatus defined in the scope in relation to c
36、ontinuous and transient, conducted and radiated disturbances. The emission requirements have been selected so as to ensure that disturbances generated by apparatus operating normally in residential, commercial and light-industrial locations do not exceed a level which could prevent other apparatus f
37、rom operating as intended. Fault conditions of apparatus are not taken into account. Not all disturbance phenomena have been included for testing purposes in this standard but only those considered as relevant for the equipment covered by this standard. These requirements represent essential electro
38、magnetic compatibility emission requirements. 5 BS EN 61000-6-3:2007+A1:2011EN 61000-6-3:2007+A1:2011 (E)6Requirements are specified for each port considered. NOTE 1 Safety considerations are not covered by this standard. NOTE 2 In special cases, situations will arise where the levels specified in t
39、his standard will not offer adequate protection; for example where a sensitive receiver is used in close proximity to an apparatus. In these instances, special mitigation measures may have to be employed. NOTE 3 As the requirements in this standard are more stringent than the requirements in IEC 610
40、00-6-4, equipment fulfilling the requirements of this standard will also comply with the requirements of IEC 61000-6-4. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated
41、references, the latest edition of the referenced document (including any amendments) applies. IEC 61000-3-2:2005 Electromagnetic compatibility (EMC) g16 Part 3-2: Limits g16 Limits for harmonic current emissions (equipment input current g100 16 A per phase) Amendment 1:2008 Amendment 2:2009 IEC 6100
42、0-3-3:2008, Electromagnetic compatibility (EMC) g16 Part 3-3: Limits g16 Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current g100 16 A per phase and not subject to conditional connection IEC 61000-3-11:2000, Electroma
43、gnetic compatibility (EMC) Part 3-11: Limits Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems Equipment with rated current g100 75 A and subject to conditional connection IEC 61000-3-12:2004, Electromagnetic compatibility (EMC) Part 3-12: Limits Li
44、mits for harmonic currents produced by equipment connected to public low-voltage systems with input current g33 16 A and g100 75 A per phase CISPR 14-1:2005, Electromagnetic compatibility Requirements for household appliances, electric tools and similar apparatus Part 1: Emission Amendment 1:2008 CI
45、SPR 16-1-2:2003, Specification for radio disturbance and immunity measuring apparatus and methods Part 1-2: Radio disturbance and immunity measuring apparatus Ancillary equipment Conducted disturbances Amendment 1:2004 Amendment 2:2006 IEC 60050-161, International Electrotechnical Vocabulary (IEV) g
46、16 Chapter 161: Electromagnetic compatibility IEC 61000-4-20:2010, Electromagnetic compatibility (EMC) Part 4-20: Testing and measurement techniques Emission and immunity testing in transverse electromagnetic (TEM) waveguide CISPR 16-1-1:2010, Specification for radio disturbance and immunity measuri
47、ng apparatus and methods Part 1-1: Radio disturbance and immunity measuring apparatus Measuring apparatus CISPR 16-1-4:2007, Specification for radio disturbance and immunity measuring apparatus and methods Part 1-4: Radio disturbance and immunity measuring apparatus Ancillary equipment Radiated dist
48、urbances Amendment 1:2007 !“ 6 BS EN 61000-6-3:2007+A1:2011EN 61000-6-3:2007+A1:2011 (E)CISPR 16-2-1:2008, Specification for radio disturbance and immunity measuring apparatus and methods Part 2-1: Methods of measurement of disturbances and immunity Conducted disturbance measurementsCISPR 16-2-3:200
49、6, Specification for radio disturbance and immunity measuring apparatus and methods Part 2-3: Methods of measurement of disturbances and immunity Radiated disturbance measurements CISPR 16-4-2:2003, Specification for radio disturbance and immunity measuring apparatus and methods Part 4-2: Uncertainties, statistics and limit modelling Uncertainty in EMC measurements CISPR 22:2008, Information technology equipment Radio disturbanc