1、BRITISH STANDARDBS EN 61076-3-106: 2006Connectors for electronic equipment Product requirements Part 3-106: Rectangular connectors Detail specification for protective housings for use with 8-way shielded and unshielded connectors for industrial environments incorporating the IEC 60603-7 series inter
2、faceThe European Standard EN 61076-3-106:2006 has the status of a British StandardICS 31.220.10g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN
3、 61076-3-106:2006This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 2007 BSI 2007ISBN 978 0 580 49998 2National forewordThis British Standard was published by BSI. It is the UK implementation of EN 61076-3-106:2006. It is identical wi
4、th IEC 61076-3-106:2006.The UK participation in its preparation was entrusted to Technical Committee EPL/48, Electromechanical components and mechanical structures for electronic equipment.A list of organizations represented on EPL/48 can be obtained on request to its secretary.This publication does
5、 not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARD EN 61076-3-106 NORME EUROP
6、ENNE EUROPISCHE NORM December 2006 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2006 CENELEC - All rights of exploitation in
7、any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61076-3-106:2006 E ICS 31.220.10 English version Connectors for electronic equipment - Product requirements Part 3-106: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and
8、unshielded connectors for industrial environments incorporating the IEC 60603-7 series interface (IEC 61076-3-106:2006) Connecteurs pour quipements lectroniques - Exigences de produit Partie 3-106: Connecteurs rectangulaires - Spcification particulire pour botiers de protection utiliss avec des conn
9、ecteurs blinds et non blinds 8 voies pour des environnements industriels incorporant linterface srie CEI 60603-7 (CEI 61076-3-106:2006) Steckverbinder fr elektronische Einrichtungen - Produktanforderungen Teil 3-106: Rechteckige Steckverbinder - Bauartspezifikation fr Schutzgehuse fr die Anwendung m
10、it 8-poligen geschirmten und ungeschirmten Steckverbindern fr industrielle Umgebungen zur Aufnahme der Schnittstelle der Reihe IEC 60603-7 (IEC 61076-3-106:2006) This European Standard was approved by CENELEC on 2006-11-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulation
11、s which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This Eur
12、opean Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are
13、 the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden
14、, Switzerland and the United Kingdom. Foreword The text of document 48B/1692A/FDIS, future edition 1 of IEC 61076-3-106, prepared by SC 48B, Connectors, of IEC TC 48, Electromechanical components and mechanical structures for electronic equipment, was submitted to the IEC-CENELEC parallel vote and w
15、as approved by CENELEC as EN 61076-3-106 on 2006-11-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2007-08-01 latest date by which the national standards conflicting with
16、 the EN have to be withdrawn (dow) 2009-11-01 The International Electrotechnical Commission (IEC) and CENELEC draw attention to the fact that it is claimed that compliance with this standard may involve the use of patent(s) concerning the free connectors in 3.5, 3.6.2, 3.10.2, 3.11, 3.11.2, 3.12.2,
17、3.13.2 and 3.14.2. The IEC and CENELEC take no position concerning the evidence, validity and scope of these patent rights. The holder of this patent right (Subclause 3.5) has assured the IEC that he/she is willing to give free licences with applicants throughout the world. In this respect, the stat
18、ement of the holder of this patent right is registered with the IEC. Information may be obtained from: The Siemon Company 27 Siemon Company Drive Watertown, CT 06795-0400 USA The holder of this patent right (3.6.2, 3.10.2, 3.11.2, 3.12.2, 3.13.2, 3.14.2) has assured the IEC that he/she is willing to
19、 negotiate licenses under reasonable and non-discriminatory terms and conditions with applicants throughout the world. In this respect, the statement of the holder of this patent right is registered with IEC. The Siemon Company 27 Siemon Company Drive Watertown, CT 06795-0400 USA The holder of this
20、patent right (3.11) has assured the IEC that he/she is willing to negotiate licenses under reasonable and non-discriminatory terms and conditions with applicants throughout the world. In this respect, the statement of the holder of this patent right is registered with IEC. Information may be obtaine
21、d for the variant in 3.11 from: Harting Electric GmbH & Co KG Postfach 1473 32328 Espelkamp Germany Attention is drawn to the possibility that some of the elements of this standard may be the subject of patent rights other than those identified above. IEC shall not be held responsible for identifyin
22、g any or all such patent rights. Annex ZA has been added by CENELEC. _ EN 61076-3-106:2006 2 Endorsement notice The text of the International Standard IEC 61076-3-106:2006 was approved by CENELEC as a European Standard without any modification. _ EN 61076-3-106:2006 3 CONTENTS 1 General data 7 1.1 S
23、cope7 1.2 Normative references 7 1.3 IEC type designation .9 2 Terminology .9 3 Dimensional information .10 3.1 Common features 10 3.2 General .10 3.3 Contact arrangement of all connector types.10 3.4 IP65 and IP67 sealing .10 3.5 Industrial IEC 60603-7 variant 01 bayonet coupling 10 3.6 Industrial
24、IEC 60603-7 variant 02 snap-in coupling.13 3.7 Industrial IEC 60603-7 variant 03 threaded coupling.17 3.8 Industrial IEC 60603-7 variant 04 snap-in coupling.19 3.9 Industrial IEC 60603-7 variant 05 locking lever coupling.21 3.10 Industrial IEC 60603-7 variant 06 snap-in coupling.23 3.11 Industrial I
25、EC 60603-7 variant 07 locking lever coupling.25 3.12 Industrial IEC 60603-7 variant 08 threaded coupling.27 3.13 Industrial IEC 60603-7 variant 09 quarter turn coupling 29 3.14 Industrial IEC 60603-7, variant 10 Pulse lock coupling .31 3.15 Termination and mounting information.32 3.16 Mounting infor
26、mation for variant 01, fixed connector33 3.17 Mounting information for variant 02, fixed connector34 3.18 Mounting information for variant 03, fixed connector35 3.19 Mounting information for variant 04, fixed connector35 3.20 Mounting information for variant 05, fixed connector36 3.21 Mounting infor
27、mation for variant 06, fixed connector37 3.22 Mounting information for variant 07, fixed connector38 3.23 Mounting information for variant 08, fixed connector39 3.24 Mounting information for variant 09, fixed connector39 3.25 Mounting information for variant 10, fixed connector40 4 Gauges Connectors
28、 for the IEC 60603-7 interface.40 5 Characteristics .40 5.1 Climatic category.40 5.2 Electrical .41 5.3 Transmission characteristics .43 5.4 Mechanical43 6 Test schedule.43 6.1 General .43 6.2 Test procedures and measuring methods 44 6.3 Preconditioning .44 6.4 Wiring and mounting of specimens 44 EN
29、 61076-3-106:2006 4 6.5 Arrangement for contact resistance test: .44 6.6 Arrangement for dynamic stress tests (test phase AP2).44 6.7 Basic (minimum) test schedule 44 6.8 Full test schedule 44 Figure 1 Variant 01, fixed connector 11 Figure 2 Variant 01, free connector12 Figure 3 Variant 02, fixed co
30、nnector 13 Figure 4 Variant 02, free connector15 Figure 5 Variant 03, fixed connector 17 Figure 6 Variant 03, free connector18 Figure 7 Variant 04, fixed connector 19 Figure 8 Variant 04, free connector20 Figure 9 Variant 05, fixed connector 21 Figure 10 Variant 05, free connector22 Figure 11 Varian
31、t 06, fixed connector.23 Figure 12 Variant 06, free connector24 Figure 13 Variant 07, fixed connector.25 Figure 14 Variant 07, free connector26 Figure 15 Variant 08, fixed connector.27 Figure 16 Variant 08, free connector28 Figure 17 Variant 09, fixed connector.29 Figure 18 Variant 09, free connecto
32、r30 Figure 19 Variant 10, fixed connector.31 Figure 20 Variant 10, free connector32 Figure 21 Variant 01, style 1 mounting drawing33 Figure 22 Variant 01, style 2 mounting drawing33 Figure 23 Variant 02 mounting drawing34 Figure 24 Variant 03 mounting drawing35 Figure 25 Variant 04 mounting drawing3
33、5 Figure 26 Variant 05 mounting drawing36 Figure 27 Variant 06 mounting drawing37 Figure 28 Variant 07 mounting drawing38 Figure 29 Variant 08 mounting drawing39 Figure 30 Variant 09 mounting drawing39 Figure 31 Variant 10, mounting drawing.40 Figure 32 Connector derating curve .42 Table 1 Dimension
34、s fixed connector variant 01 11 Table 2 Dimensions free connector variant 0112 Table 3 Dimensions fixed connector variant 02 14 Table 4 Dimensions free connector variant 0216 Table 5 Dimension fixed connector variant 0317 Table 6 Dimensions free connector variant 0318 EN 61076-3-106:2006 5 Table 7 D
35、imensions fixed connector variant 04 19 Table 8 Dimensions free connector variant 0420 Table 9 Dimensions fixed connector variant 05 21 Table 10 Dimensions free connector variant 0522 Table 11 Dimensions fixed connector variant 06 23 Table 12 Dimensions free connector variant 0624 Table 13 Dimension
36、s fixed connector variant 07 25 Table 14 Dimensions free connector variant 0726 Table 15 Dimensions fixed connector variant 08 27 Table 16 Dimensions free connector variant 0828 Table 17 Dimensions fixed connector variant 09 29 Table 18 Dimensions free connector variant 0930 Table 19 Dimensions fixe
37、d connector variant 10 31 Table 20 Dimensions free connector variant 1032 Table 21 Variant 01, style 1 mounting information33 Table 22 Variant 01, style 2 mounting information34 Table 23 Variant 02 mounting information 34 Table 24 Variant 03 mounting information 35 Table 25 Variant 04 mounting infor
38、mation 35 Table 26 Variant 05 mounting information 36 Table 27 Variant 06 mounting information 37 Table 28 Variant 07 mounting Information38 Table 29 Variant 08 mounting information 39 Table 30 Variant 09 mounting information 39 Table 31 Variant 10 mounting information 40 Table 32 Climatic categorie
39、s selected values for environmental performance level A40 Table 33 Creepage and clearance .41 Table 34 Test group P .45 Table 35 Test group AP Dynamic/climatic .46 Table 36 Test Group BP Mechanical .48 Table 37 Test group CP Continuity49 Annex ZA (normative) Normative references to international pub
40、lications with their corresponding European publications50EN 61076-3-106:2006 6 CONNECTORS FOR ELECTRONIC EQUIPMENT PRODUCT REQUIREMENTS Part 3-106: Rectangular connectors Detail specification for protective housings for use with 8-way shielded and unshielded connectors for industrial environments i
41、ncorporating the IEC 60603-7 series interface 1 General data 1.1 Scope This part of IEC 61076 constitutes the detail specification in the IEC system for electronic components for 8-way connectors for frequencies up to 600 MHz. This part of IEC 61076 covers protective housings for upgrading existing
42、8-way shielded and unshielded connectors utilizing the interface described in the IEC 60603-7 series to IP65 and IP67 ratings according to IEC 60529, for use in industrial environments. The housings cover a variety of different locking mechanisms according to this part of IEC 61076 and a variety of
43、different mounting configurations and termination types which are detailed in the IEC 60603-7 series. Common mating configuration for all variants are defined in IEC 60603-7. The mating dimensions for the housings under Clause 3 allow the mating conditions under IEC 60603-7 to be fulfilled. The full
44、y assembled variants (connectors) described in this part of IEC 61076 incorporate fully compliant IEC 60603-7 series fixed and free connectors. 1.2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition c
45、ited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60050(581):1978, International Electrotechnical Vocabulary (IEV) Chapter 581: Electro-mechanical components for electronic equipment IEC 60068-1, Environmental testing Part 1:
46、General and guidance IEC 60068-2-14, Environmental testing Part 2: Tests. Test N: Change of temperature IEC 60068-2-30, Environmental testing Part 2-30: Tests Test Db: Damp heat, cyclic (12 h + 12 h cycle) IEC 60512 (all parts), Connectors for electronic equipment Tests and measurements EN 61076-3-1
47、06:2006 7 IEC 60512-1-100, Connectors for electronic equipment Tests and measurements Part 1-100: General Applicable publications IEC 60529, Degrees of protection provided by enclosures (IP Code) IEC 60603-7 (all parts), Connectors for electronic equipment IEC 60664-1, Insulation coordination for eq
48、uipment within low-voltage systems Part 1: Principles, requirements and tests IEC 61076-1, Connectors for electronic equipment Product requirements Part 1: Generic specification IEC 61156-2, Multicore and symmetrical pair/quad cables for digital communications Part 2: Horizontal floor wiring Section
49、al specification IEC 61156-3, Multicore and symmetrical pair/quad cables for digital communications Part 3: Work area wiring Sectional specification IEC 61156-4, Multicore and symmetrical pair/quad cables for digital communications Part 4: Riser cables Sectional specification EN 61076-3-106:2006 8 1.3 IEC type designation P