EN 61169-50-2015 en Radio-frequency connectors - Part 50 Sectional specification for RF coaxial connectors with inner diameter of outer conductors 4 11 mm with quick lock system - .pdf

上传人:ideacase155 文档编号:719682 上传时间:2019-01-04 格式:PDF 页数:26 大小:1.38MB
下载 相关 举报
EN 61169-50-2015 en Radio-frequency connectors - Part 50 Sectional specification for RF coaxial connectors with inner diameter of outer conductors 4 11 mm with quick lock system - .pdf_第1页
第1页 / 共26页
EN 61169-50-2015 en Radio-frequency connectors - Part 50 Sectional specification for RF coaxial connectors with inner diameter of outer conductors 4 11 mm with quick lock system - .pdf_第2页
第2页 / 共26页
EN 61169-50-2015 en Radio-frequency connectors - Part 50 Sectional specification for RF coaxial connectors with inner diameter of outer conductors 4 11 mm with quick lock system - .pdf_第3页
第3页 / 共26页
EN 61169-50-2015 en Radio-frequency connectors - Part 50 Sectional specification for RF coaxial connectors with inner diameter of outer conductors 4 11 mm with quick lock system - .pdf_第4页
第4页 / 共26页
EN 61169-50-2015 en Radio-frequency connectors - Part 50 Sectional specification for RF coaxial connectors with inner diameter of outer conductors 4 11 mm with quick lock system - .pdf_第5页
第5页 / 共26页
点击查看更多>>
资源描述

1、BSI Standards PublicationRadio-frequency connectorsPart 50: Sectional specification for RF coaxial connectors with inner diameter of outer conductors 4,11 mm with quick lock system Characteristic impedance 50 Ohm (type QMA)BS EN 61169-50:2015National forewordThis British Standard is the UK implement

2、ation of EN 61169-50:2015. It isidentical to IEC 61169-50:2014.The UK participation in its preparation was entrusted to TechnicalCommittee EPL/46, Cables, wires and waveguides, radio frequency connectors and accessories for communication and signalling.A list of organizations represented on this com

3、mittee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2015.Published by BSI Standards Limited 2015ISBN 978 0 580 83683 1ICS 33.120.

4、30Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 March 2015.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 61169-50:2015

5、EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 61169-50 March 2015 ICS 33.120.30 English Version Radio-frequency connectors - Part 50: Sectional specification for RF coaxial connectors with inner diameter of outer conductors 4,11 mm with quick lock system - Characteristic impedance 50 Ohm (typ

6、e QMA) (IEC 61169-50:2014) Connecteurs pour frquences radiolectriques - Partie 50: Spcification intermdiaire relative aux connecteurs coaxiaux pour frquences radiolectriques avec diamtre intrieur des conducteurs extrieurs de 4,11 mm systme de verrouillage rapide - Impdance caractristique 50 Ohm (typ

7、e QMA) (IEC 61169-50:2014) Hochfrequenz-Steckverbinder - Teil 50: Rahmenspezifikation fr koaxiale HF Steckverbinder mit 4,11 mm Innendurchmesser des Auenleiters und Schnellverriegelung - Wellenwiderstand 50 Ohm (Typ QMA) (IEC 61169-50:2014) This European Standard was approved by CENELEC on 2014-11-2

8、7. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtain

9、ed on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to

10、the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece,

11、Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotec

12、hnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 61169-50:2015 E BS EN 61169-50:2015EN 61169-50:2015 - 2 -

13、Foreword The text of document 46F/264/CDV, future edition 1 of IEC 61169-50, prepared by SC 46F “R.F. and microwave passive components“, of IEC/TC 46 “Cables, wires, waveguides, R.F. connectors, R.F. and microwave passive components and accessories“ was submitted to the IEC-CENELEC parallel vote and

14、 approved by CENELEC as EN 61169-50:2015. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2015-09-13 latest date by which the national standards conflicting with the docu

15、ment have to be withdrawn (dow) 2017-11-27 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the Internat

16、ional Standard IEC 61169-50:2014 was approved by CENELEC as a European Standard without any modification. BS EN 61169-50:2015- 3 - EN 61169-50:2015 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole

17、 or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE 1 When an International Publication

18、 has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here: www.cenelec.eu. Publication Year Title EN/HD Year IEC 61169-1 2013 Radio-frequency connec

19、tors - Part 1: Generic specification - General requirements and measuring methods EN 61169-1 2013 IEC 62037 series Passive RF and microwave devices, intermodulation level measurement EN 62037 series BS EN 61169-50:2015 2 IEC 61169-50:2014 IEC 2014 CONTENTS INTRODUCTION . 5 1 Scope 6 2 Normative refe

20、rences 6 3 Mating face and gauge information 7 3.1 Dimensions General connectors . 7 3.1.1 Connector with socket-centre contact 7 3.1.2 Connector with pin-centre contact 9 3.2 Gauges for general purpose connectors 10 3.2.1 Gauge pins for socket-centre contact . 10 3.2.2 Test procedure 11 4 Quality a

21、ssessment procedures . 11 4.1 General . 11 4.2 Ratings and characteristics (see Clause 5 of IEC 61169-1:2013) 11 4.3 Test schedule and inspection requirements. 13 4.3.1 Acceptance tests . 13 4.4 Procedures for the quality conformance 14 Quality conformance inspection . 14 4.4.1Qualification approval

22、 and its maintenance 15 4.4.25 Instructions for preparation of detail specifications 15 5.1 General . 15 5.2 Identification of the component . 15 5.3 Performance . 15 5.4 Marking, ordering information and related matters 15 5.5 Selection of tests, test conditions and severities . 16 5.6 Blank detail

23、 specification pro-forma for type QMA connector . 16 6 Marking . 21 6.1 Marking of component . 21 6.2 Marking and contents of package 21 Figure 1 Connector with socket centre contact (for dimensions, see Table 1) . 7 Figure 2 Female centre contact (for dimensions, see Table 1) . 7 Figure 3 Connector

24、 with pin centre contact (for dimensions, see Table 2) 9 Figure 4 Details of pin centre contact (for dimensions, see Table 2) . 9 Figure 5 Gauge pin for socket-centre contact (for dimensions, see Table 3) . 10 Table 1 Dimensions of connector with socket centre contact 8 Table 2 Dimensions of connect

25、or with pin-centre contact . 10 Table 3 Gauge dimensions for socket centre contact . 11 Table 4 Rating and characteristics . 11 Table 5 Acceptance tests . 13 Table 6 Periodic tests 14 BS EN 61169-50:2015IEC 61169-50:2014 IEC 2014 5 INTRODUCTION The International Electrotechnical Commission (IEC) dra

26、ws attention to the fact that it is claimed that compliance with this document may involve the use of a patent concerning the design of the connector given in 3.1. IEC takes no position concerning the evidence, validity and scope of this patent right. The holder of this patent right has assured the

27、IEC that he/she is willing to negotiate licence under reasonable and non-discriminatory terms and conditions with applicants throughout the world. In this respect, the statement of the holders of this patent right is registered with IEC. More detailed information may be obtained from: HUBER+SUHNER A

28、G Mr. Germann Reto, RF Division R Phone:+41 71 353 4653 Degersheimerstrasse 14, CH-9100 Herisau, Switzerland Or Radiall SA Mr. Pierre Bigot, RFI Division P Phone:+33 47 650 0057 Z.I Centralp 642 rue Emile Romanet, B.P. 35 F-38341 Voreppe Cedex, France Attention is drawn to the possibility that some

29、of elements of this document may be the subject of patent rights other than those identified above .IEC shall not be held responsible for identifying any or all such patent rights. ISO (www.iso.org/patents) and IEC (http:/patents.IEC.ch) maintain on-line data bases of patents relevant to their stand

30、ards. Users are encouraged to consult the data bases for the most up to date information concerning patents. BS EN 61169-50:2015 6 IEC 61169-50:2014 IEC 2014 RADIO-FREQUENCY CONNECTORS Part 50: Sectional specification for RF coaxial connectors with inner diameter of outer conductors 4,11 mm with qui

31、ck lock system Characteristic impedance 50 (type QMA) 1 Scope This part of IEC 61169, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for type QMA R.F. coaxial connectors with quick lock. The connectors are normally used with

32、50 corrugated cable and flexible cables for middle power applications in an operating range up to 6 GHz. It describes the interface dimensions for general purpose connectors with gauging information and the mandatory tests selected from IEC 61169-1, applicable to all detail specifications relative t

33、o type QMA connectors. This specification indicates the recommended performance characteristics to be considered when writing a DS and covers all tests schedules and inspection requirements. NOTE Metric dimension are original dimensions. All un-dimensioned pictorial configurations are for reference

34、purpose only. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (inclu

35、ding any amendments) applies. IEC 61169-1:2013, Radio-frequency connectors Part 1: Generic specification General requirements and measuring methods IEC 62037 (all parts), Passive RF and microwave devices, intermodulation level measurement BS EN 61169-50:2015IEC 61169-50:2014 IEC 2014 7 3 Mating face

36、 and gauge information 3.1 Dimensions General connectors 3.1.1 Connector with socket-centre contact Figure 1 Connector with socket-centre contact (for dimensions, see Table 1) Figure 2 Female centre contact (for dimensions, see Table 1) IEC IEC BS EN 61169-50:2015 8 IEC 61169-50:2014 IEC 2014 Table

37、1 Dimensions of connector with socket-centre contact Ref. mm Additional notes Min. Max. A 5,555 5,585 B 4,9 4,95 C - - Dimensions shall match the 50 line D - 4,95 E - 5,585 F 0,95 - G 1,24 1,3 X1 54 56 Degree X2 13 17 Degree X3 28 32 Degree Z1 0,055 0,105 Radius Z2 0,9 1,1 Radius Z3 - 0,2 Radius 1 9

38、,1 - Degree 2 5,53 5,56 3 0,2 0,4 4 6,8 - 5 0,2 0,3 6 0,00 0,25 7 0,00 0,25 8 2,2 - BS EN 61169-50:2015IEC 61169-50:2014 IEC 2014 9 3.1.2 Connector with pin-centre contact Figure 3 Connector with pin-centre contact (for dimensions, see Table 2) Figure 4 Details of pin-centre contact (for dimensions,

39、 see Table 2) IEC IEC BS EN 61169-50:2015 10 IEC 61169-50:2014 IEC 2014 Table 2 Dimensions of connector with pin-centre contact Ref. mm Additional notes Min. Max. A - 10,55 B 5,62 - C 4,98 5,02 D 5,60 - E 0,90 0,94 F - 0,38 G - - H - - X1 - - Degree X2 33 35 Degree Z1 0,07 0,13 Radius 1 9,28 2 - - 3

40、 - - 4 0,00 0,25 5 0,88 - 6 1,35 1,7 7 0 0,25 3.2 Gauges for general purpose connectors 3.2.1 Gauge pins for socket-centre contact Figure 5 Gauge pin for socket-centre contact (for dimensions, see Table 3) IEC BS EN 61169-50:2015IEC 61169-50:2014 IEC 2014 11 Table 3 Gauge dimensions for socket-centr

41、e contact Gauge A Maximum material for measurement of maximum insertion force Gauge B Minimum material for measurement of minimum retention force Mass of gauge: 20 g + 2 g Ref. mm mm Min. Max. Min. Max. B 0,950 0,955 0,899 0,902 L 1,27 1,90 1,27 1,90 A1 40 60 89 91 R 0,38 0,38 Material: steel, polis

42、hed, surface roughness: Ra=0,4 m maximum. 3.2.2 Test procedure The gauge A (see Figure 5) shall be inserted into the socket-centre contact one time with a minimum depth of 0,51 mm. The insertion force shall not exceed 13,3 N. After this, the gauge B shall be inserted in socket-centre contact. The co

43、ntact shall retain the mass the gauge in a vertical downward position. The test also shall be carried out on connector when socket-centre contact is not removed. 4 Quality assessment procedures 4.1 General Subclauses 4.2 to 4.4 provide recommended ratings, performance and test conditions to be consi

44、dered when writing a detail specification (DS). They also provide an appropriate schedule of tests with minimum levels of conformance inspection sampling, together with the pro-forma blank detail specification (BDS) and instructions for the preparation of a detail specification. 4.2 Ratings and char

45、acteristics (see Clause 5 of IEC 61169-1:2013) The values indicated below are recommended for QMA series RF connectors and are given for the writer of the detail specification. They are applicable for the condition when the connectors are fully mated. Certain tests will usually not be required. When

46、 these tests are required, appropriate values shall be entered in the detail specification at the discretion of the specification writer. Rating and characteristics are given in Table 4. Table 4 Rating and characteristics Ratings and characteristics Test method IEC 61169-1:2013 Subclause Value Remar

47、ks, deviation from standard test method Electrical Nominal Impedance 50 Frequency range DC to 6 GHz Or upper frequency limit of cable Reflection factor a9.2.1 For interface only DC to 2,5 GHz 0,025 BS EN 61169-50:2015 12 IEC 61169-50:2014 IEC 2014 Ratings and characteristics Test method IEC 61169-1:

48、2013 Subclause Value Remarks, deviation from standard test method 2,5 GHz to 4 GHz 0,038 4 GHz to 6 GHz 0,057 Insertion loss 1 000 Vrms Working voltage at sea level 335 Vrms Screening effectiveness e9.2.7 0,5 GHz to 3 GHz 80 dB 3 GHz to 6 GHz 70 dB Intermodulation level IEC 62037 1,8 GHz 120 dBc Mec

49、hanical Gauge retention force (resilient contact) 9.3.4 centre contact 0,20 N Centre contact captivationf9.3.5 axial force 22 N torque 0,028 Nm Engagement and separation axial force engagement 27 N Typical separation 20 N Typical Tensile strength of coupling mechanism 9.3.11 60 N Vibration random 9.3.3 5 Hz to 20 Hz 0,02 g/Hz 20 Hz to 500 Hz 3 dB/oct E