EN 61300-2-22-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22 Tests - Change of temperature《光纤互连器件和无源器件 基本试验和.pdf

上传人:appealoxygen216 文档编号:719976 上传时间:2019-01-04 格式:PDF 页数:12 大小:490.24KB
下载 相关 举报
EN 61300-2-22-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22 Tests - Change of temperature《光纤互连器件和无源器件 基本试验和.pdf_第1页
第1页 / 共12页
EN 61300-2-22-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22 Tests - Change of temperature《光纤互连器件和无源器件 基本试验和.pdf_第2页
第2页 / 共12页
EN 61300-2-22-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22 Tests - Change of temperature《光纤互连器件和无源器件 基本试验和.pdf_第3页
第3页 / 共12页
EN 61300-2-22-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22 Tests - Change of temperature《光纤互连器件和无源器件 基本试验和.pdf_第4页
第4页 / 共12页
EN 61300-2-22-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22 Tests - Change of temperature《光纤互连器件和无源器件 基本试验和.pdf_第5页
第5页 / 共12页
点击查看更多>>
资源描述

1、BRITISH STANDARDBS EN 61300-2-22:2007Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-22: Tests Change of temperatureThe European Standard EN 61300-2-22:2007 has the status of a British StandardICS 33.180.20g49g50g3g38g50g51g60g44g49g42g3g58g44g

2、55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 61300-2-22:2007This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 August 2

3、007 BSI 2007ISBN 978 0 580 54207 7National forewordThis British Standard is the UK implementation of EN 61300-2-22:2007. It is identical to IEC 61300-2-22:2007. It supersedes BS EN 61300-2-22:1997 which is withdrawn. The UK participation in its preparation was entrusted by Technical Committee GEL/86

4、, Fibre optics, to Subcommittee GEL/86/2, Fibre optic interconnecting devices and passive components.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are re

5、sponsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARD EN 61300-2-22 NORME EUROPENNE EUROPISCHE NORM June 2007 CENELEC European Committee for Electrotechnical St

6、andardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61300-2

7、-22:2007 E ICS 33.180.20 Supersedes EN 61300-2-22:1997English version Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-22: Tests - Change of temperature (IEC 61300-2-22:2007) Dispositifs dinterconnexion et composants passifs fibres optiques

8、- Mthodes fondamentales dessais et de mesures - Partie 2-22: Essais - Variations de temprature (CEI 61300-2-22:2007) Lichtwellenleiter - Verbindungselemente und passive Bauteile - Grundlegende Prf- und Messverfahren - Teil 2-22: Prfungen - Temperaturwechsel (IEC 61300-2-22:2007) This European Standa

9、rd was approved by CENELEC on 2007-04-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concernin

10、g such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its

11、own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, It

12、aly, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Foreword The text of document 86B/2440/FDIS, future edition 2 of IEC 61300-2-22, prepared by SC 86B, Fibre optic interconnecting devic

13、es and passive components, of IEC TC 86, Fibre optics, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61300-2-22 on 2007-04-01. This European Standard supersedes EN 61300-2-22:1997. EN 61300-2-22:1997 specifies tests Na and Nb of EN 60068-2-14, however this EN 61300

14、-2-22:2007 describes the test method of Nb and specifies “optional cycle” for some other performance categories. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2008-01-01 lat

15、est date by which the national standards conflicting with the EN have to be withdrawn (dow) 2010-04-01 Annexes ZA and ZB have been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 61300-2-22:2007 was approved by CENELEC as a European Standard without any modification

16、. _ EN 61300-2-22:2007 2 CONTENTS 1 Scope.4 2 Normative references .4 3 General description 4 4 Apparatus.4 5 Procedure 4 5.1 Preconditioning .5 5.2 Initial measurements .5 5.3 Testing5 5.4 Recovery.6 5.5 Final measurements 6 6 Severity6 7 Details to be specified 7 Bibliography8 Figure 1 Temperature

17、 profile5 Figure 2 Optional temperature profile.6 Table 1 Severities6 EN 61300-2-22:2007 3 Annex ZA (normative) Special national conditions .9 .17 nnex ZBBAnnex ZBibliography17 Annex ZB (normative) Normative references to international publications with their corresponding European publications 9 FI

18、BRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS BASIC TEST AND MEASUREMENT PROCEDURES Part 2-22: Tests Change of temperature 1 Scope This part of IEC 61300 describes a procedure to determine the suitability of a fibre optic device to withstand the effects of a change of temperature or a suc

19、cession of changes of temperature. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments)

20、applies. IEC 60068-2-14, Basic environmental testing procedures Part 2-14: Tests Test N: Change of temperature 3 General description This procedure is conducted in accordance with IEC 60068-2-14, test Nb. The device under test (DUT) is first subjected to one extreme of temperature for a given period

21、 of time. It is then subjected to the other extreme of temperature for an equal period of time. 4 Apparatus The apparatus consists of suitable environmental chambers in accordance with IEC 60068-2-14, test Nb. The rate of change of temperature shall be: (1 0,2) C/min 5 Procedure These procedures are

22、 in accordance with IEC 60068-2-14, test Nb. Unless otherwise stated in the relevant specification: include 1,5 m of cable in the climatic chamber for each port monitored during the test; if optical measurements are requested during the test by the relevant specification, these measurements shall be

23、 performed (at a minimum) at the end of each dwell at each temperature extreme; allow dependence on wavelength scan time for components that require wavelength scanning. EN 61300-2-22:2007 4 5.1 Preconditioning Unless otherwise stated in the relevant specification, maintain the DUT under standard at

24、mospheric conditions for 2 h minimum. Clean the mechanical and optical alignment parts of the DUT according to the manufacturers instructions. 5.2 Initial measurements Take initial examinations and measurements as required by the relevant specification. 5.3 Testing 5.3.1 Place the specimen in the ch

25、amber in its normal operating position and make connections to the monitoring equipment. 5.3.2 Unless otherwise specified, the temperature profile in Figure 1 shall be applied. Start at standard atmospheric conditions and ramp down to the low temperature AT at 1 C/min. Maintain the low temperature d

26、uring t1for a minimum of 60 min. Ramp up to the high temperature TBat 1 C/min. Maintain the temperature during t1, then ramp down to the low temperature and repeat this profile for the required number of cycles. t1t1TBTAA First cycle Second cycle Time t Temperature in the chamber IEC 263/07 A = star

27、t of first cycle. Figure 1 Temperature profile NOTE It is permissible to increase the dwell time at each extreme to allow sufficient time to perform a complete set of measurements. 5.3.3 Optional cycle: for some performance categories, it may be necessary to ramp to the high temperature first and in

28、clude a dwell at room temperature between ramps to the extreme temperatures. In this case, the profile in Figure 2 shall be applied. Start at standard atmospheric conditions and ramp up to the high temperature T at 1 C/min. Then maintain the high temperature during t1for a minimum of 60 min. Ramp do

29、wn to standard atmospheric conditions at 1 C/min. Maintain standard atmospheric conditions for a minimum of 60 min. Ramp down to the low temperature TLat 1 C/min. Maintain that temperature during t1for a minimum of 60 min. Ramp up to standard atmospheric conditions at 1 C/min and dwell for a minimum

30、 of 60 min. The subsequent cycles will have the same pattern. EN 61300-2-22:2007 5 t1T TLA First cycle Second cycle Time t t1IEC 264/07 A = start of first cycle Figure 2 Optional temperature profile 5.4 Recovery Allow the specimen to remain under standard atmospheric conditions for a period of at le

31、ast 2 h. 5.5 Final measurements Record final measurements as required by the relevant specification. Unless otherwise specified in the relevant specification, clean the DUT according to the manufacturers instructions prior to recording final measurements. 6 Severity Each of the following severities

32、consist of a combination of a low temperature with the corresponding high temperature and the corresponding number of cycles. One of them shall be specified in the relevant specification: Table 1 Severities Category Low temperature C High temperature C Number of cycles C 10 +60 5 U 25 +70 12 E 40 +8

33、5 12 O 40 +75 21 A 40 +65 20 G 40 +65 20 S 30 +60 20 EN 61300-2-22:2007 6 7 Details to be specified The following details, as applicable, shall be specified in the relevant specification: severity; initial examinations and measurements and performance requirements; examinations and measurements duri

34、ng test and performance requirements; final examinations and measurements and performance requirements; deviations from test procedure; additional pass/fail criteria; relevant monitoring procedure. EN 61300-2-22:2007 7 Bibliography IEC 61300-1, Fibre optic interconnecting devices and passive compone

35、nts Basic test and measurement procedures Part 1: General and guidance IEC 61300-2-47, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-47: Tests Thermal shocks _ EN 61300-2-22:2007 8 NOTE Harmonized as EN 61300-1:2003 (not modified). NOTE Harmo

36、nized as EN 61300-2-47:2007 (not modified). Annex ZA (normative) Special national conditions Special national condition: National characteristic or practice that cannot be changed even over a long period, e.g. climatic conditions, electrical earthing conditions. NOTE If it affects harmonization, it

37、forms part of the European Standard / Harmonization Document. For the countries in which the relevant special national conditions apply these provisions are normative, for other countries they are informative. Clause Special national condition 6, Table 1 Finland In the categories E, O, A and G, the

38、minimum temperature shall be 45 C. _ EN 61300-2-22:2007 9 Annex ZB (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the e

39、dition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 6006

40、8-2-14 -1)Environmental testing - Part 2: Tests - Test N: Change of temperatureEN 60068-2-14 19992)_ BS EN 61300-2-22:2007BSI389 Chiswick High RoadLondonW4 4ALBSI British Standards InstitutionBSI is the independent national body responsible for preparing British Standards. It presents the UK view on

41、 standards in Europe and at the international level. It is incorporated by Royal Charter.RevisionsBritish Standards are updated by amendment or revision. Users of British Standards should make sure that they possess the latest amendments or editions.It is the constant aim of BSI to improve the quali

42、ty of our products and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using this British Standard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover. Tel: +44 (0)20 8996 9000. Fax: +44 (0)

43、20 8996 7400.BSI offers members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards.Buying standardsOrders for all BSI, international and foreign standards publications should be addressed to Customer Services. Tel: +44 (0)

44、20 8996 9001. Fax: +44 (0)20 8996 7001. Email: ordersbsi-. Standards are also available from the BSI website at http:/www.bsi-.In response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as British Standards, unless otherwise

45、 requested.Information on standardsBSI provides a wide range of information on national, European and international standards through its Library and its Technical Help to Exporters Service. Various BSI electronic information services are also available which give details on all its products and ser

46、vices. Contact the Information Centre. Tel: +44 (0)20 8996 7111. Fax: +44 (0)20 8996 7048. Email: infobsi-.Subscribing members of BSI are kept up to date with standards developments and receive substantial discounts on the purchase price of standards. For details of these and other benefits contact

47、Membership Administration. Tel: +44 (0)20 8996 7002. Fax: +44 (0)20 8996 7001. Email: membershipbsi-.Information regarding online access to British Standards via British Standards Online can be found at http:/www.bsi- information about BSI is available on the BSI website at http:/www.bsi-.CopyrightC

48、opyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of the publications of the international standardization bodies. Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any

49、form or by any means electronic, photocopying, recording or otherwise without prior written permission from BSI.This does not preclude the free use, in the course of implementing the standard, of necessary details such as symbols, and size, type or grade designations. If these details are to be used for any other purpose than implementation