EN 61300-2-34-2009 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-34 Tests - Resistance to solvents and contaminatin.pdf

上传人:sofeeling205 文档编号:719986 上传时间:2019-01-04 格式:PDF 页数:14 大小:842.35KB
下载 相关 举报
EN 61300-2-34-2009 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-34 Tests - Resistance to solvents and contaminatin.pdf_第1页
第1页 / 共14页
EN 61300-2-34-2009 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-34 Tests - Resistance to solvents and contaminatin.pdf_第2页
第2页 / 共14页
EN 61300-2-34-2009 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-34 Tests - Resistance to solvents and contaminatin.pdf_第3页
第3页 / 共14页
EN 61300-2-34-2009 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-34 Tests - Resistance to solvents and contaminatin.pdf_第4页
第4页 / 共14页
EN 61300-2-34-2009 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-34 Tests - Resistance to solvents and contaminatin.pdf_第5页
第5页 / 共14页
点击查看更多>>
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI British StandardsWB9423_BSI_StandardColCov_noK_AW:BSI FRONT COVERS 5/9/08 12:55 Page 1Fibre optic interconnectingdevices and passive components Basic test andmeasurement procedures Part 2-34: Tests R

2、esistance to solvents and contaminating fluids of inteconnecting components and closuresBS EN 61300-2-34:2009National forewordThis British Standard is the UK implementation of EN 61300-2-34:2009. It isidentical to IEC 61300-2-34:2009. It supersedes BS EN 61300-2-34:1997which is withdrawn.The UK part

3、icipation in its preparation was entrusted by Technical CommitteeGEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre optic interconnectingdevices and passive components.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purpor

4、t to include all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2009ISBN 978 0 580 55781 1ICS 33.180.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the Standar

5、dsPolicy and Strategy Committee on 30 September 2009Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 61300-2-34:2009EUROPEAN STANDARD EN 61300-2-34 NORME EUROPENNE EUROPISCHE NORM July 2009 CENELEC European Committee for Electrotechnical Standardization Comit Europ

6、en de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: Avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61300-2-34:2009 E ICS 33.180.20 Su

7、persedes EN 61300-2-34:1997English version Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-34: Tests - Resistance to solvents and contaminating fluids of interconnecting components and closures (IEC 61300-2-34:2009) Dispositifs dinterconnex

8、ion et composants passifs fibres optiques - Procdures fondamentales dessais et de mesures - Partie 2-34: Essais - Rsistance des composants dinterconnexion et des botiers aux solvants et aux fluides contaminants (CEI 61300-2-34:2009) Lichtwellenleiter -Verbindungselemente und passive Bauteile - Grund

9、legende Prf- und Messverfahren - Teil 2-34: Bestndigkeit von Verbindungsbauteilen und Muffen gegen Lsemittel und verschmutzende Flssigkeiten (IEC 61300-2-34:2009) This European Standard was approved by CENELEC on 2009-06-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulatio

10、ns which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This Eu

11、ropean Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members ar

12、e the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Sp

13、ain, Sweden, Switzerland and the United Kingdom. BS EN 61300-2-34:2009EN 61300-2-34:2009 2 Foreword The text of document 86B/2826/FDIS, future edition 2 of IEC 61300-2-34, prepared by SC 86B, Fibre optic interconnecting devices and passive components, of IEC TC 86, Fibre optics, was submitted to the

14、 IEC-CENELEC parallel vote and was approved by CENELEC as EN 61300-2-34 on 2009-06-01. This European Standard supersedes EN 61300-2-34:1997. The main changes from EN 61300-2-34:1997 are as follows: the procedure and severity have been reconsidered. The following dates were fixed: latest date by whic

15、h the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2010-03-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2010-06-01 Annex ZA has been added by CENELEC. _ Endorsement notice The

16、text of the International Standard IEC 61300-2-34:2009 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following note has to be added for the standard indicated: IEC 60068-2-74 NOTE Harmonized as EN 60068-2-74:1999 (not modified

17、). _ BS EN 61300-2-34:2009 3 EN 61300-2-34:2009 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cit

18、ed applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 61300-1 - 1)Fi

19、bre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 1: General and guidance EN 61300-1 2003 2)1)Undated reference. 2)Valid edition at date of issue. BS EN 61300-2-34:2009 2 61300-2-34 IEC:2009(E) CONTENTS 1 Scope.5 2 Normative references5 3 General

20、 description.5 4 Apparatus.5 4.1 Containers.5 4.2 Fluids 5 4.3 Heat source.6 4.4 Oven .6 5 Procedure.6 5.1 General .6 5.2 Preconditioning6 5.3 Initial examinations and measurements6 5.4 Conditioning 6 5.5 Recovery.6 5.6 Final examinations and measurements 6 6 Severity 7 6.1 General .7 6.2 Exposure a

21、nd drying duration.7 6.3 Fuels, lubricants, hydraulic fluids, cleaning agents and moisture repellents and anti-freeze agents .7 7 Details to be specified.8 Bibliography9 Table 1 Preferred test durations .7 Table 2 Preferred drying durations7 Table 3 List of test fluids 8 BS EN 61300-2-34:200961300-2

22、-34 IEC:2009(E) 5 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS BASIC TEST AND MEASUREMENT PROCEDURES Part 2-34: Tests Resistance to solvents and contaminating fluids of interconnecting components and closures 1 Scope The purpose of this part of IEC 61300 is for testing fibre optic inte

23、rconnecting components and closures. The object of this test is to define a standard test method to assess the effects of short term exposure to fluids and lubricants on fibre optic interconnecting components and closures. 2 Normative references The following referenced documents are indispensable f

24、or the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61300-1, Fibre optic interconnecting devices and passive components Basic test and measurement proc

25、edures Part 1: General and guidance 3 General description This test method covers the effects of contaminating fluids on the properties of fibre optic interconnecting components and closures. Testing is performed by immersing specimens in a specified fluid for a specified period at a specified tempe

26、rature. A separate specimen shall be used with each fluid. Properties are measured prior to and after exposure to the fluid. WARNING Intended users of this procedure are cautioned that tests of this nature may involve the use of certain hazardous material, operations and equipment. In particular, so

27、me of the fluids that may be used are flammable or may constitute health hazards, or both. Test temperatures should be at least 10 C below the flashpoint of any fluid being used. Open flame heat sources should not be used with any organic solvents. Test personnel should consult the relevant material

28、s safety data sheets when necessary. 4 Apparatus 4.1 Containers A boro-silicate glass or stainless steel vessel of suitable volume for each test fluid shall be used. Vessels shall be of sufficient size and capacity to permit the specimen to be immersed until it is fully covered in the selected fluid

29、 without violating other physical constraints (e.g. minimum cable bend radius). 4.2 Fluids Fluids used shall be in accordance with the relevant specification for the fluid. BS EN 61300-2-34:2009 6 61300-2-34 IEC:2009(E) 4.3 Heat source A suitable heat source capable of achieving and maintaining the

30、specified temperatures within 2 C of the required setting shall be used. 4.4 Oven A suitable oven to dry the specimen shall be used. 5 Procedure 5.1 General The preparation of the specimen shall be in accordance with the relevant specification. If cables are fitted they must be long enough to exit t

31、he test medium. Where no cables are fitted blanking plugs must be inserted. 5.2 Preconditioning Clean the mechanical and optical alignment parts of the specimen according to the manufacturers instructions. Unless otherwise stated, maintain the specimen under standard atmospheric condition according

32、to IEC 61300-1 for 2 h minimum. 5.3 Initial examinations and measurements If specified, perform initial examinations and measurements as required by the relevant specification. 5.4 Conditioning For each specified fluid, prepare a vessel with sufficient fluid such that the specimen can be adequately

33、immersed. Immerse the specimen for the specified period while maintaining the fluid temperature. NOTE In the case of volatile fluids, it may be necessary to add additional amounts of fluid (heated to the test temperature) during the test in order to keep the specimen immersed. 5.5 Recovery At the en

34、d of the immersion period, remove the specimen and wipe off surplus fluid. Where applicable as defined in the relevant specification, dry components in an oven at an appropriate temperature for a defined period. 5.6 Final examinations and measurements Upon completion of the test, the specimen(s) sha

35、ll be examined and all necessary observations recorded as specified in the relevant specification. Careful attention shall be given to swelling of materials, loss of adhesive bonding between bonded surfaces, corrosion of materials, softening of materials, cracks in material, degradation of optical c

36、haracteristics, etc. The functional measurements shall be accomplished at the standard test conditions as defined in IEC 61300-1, unless otherwise specified in the relevant specification. BS EN 61300-2-34:200961300-2-34 IEC:2009(E) 7 6 Severity 6.1 General The severity consists of the combination of

37、 the fluid, exposure duration and the fluid temperature. The severity shall be specified in the relevant specification. The following preferred severities are non-mandatory severities which may be specified for this procedure. 6.2 Exposure and drying duration Specimen shall be exposed to the test fo

38、r the following preferred duration: Table 1 Preferred test durations 1 h 24 h 5 days 7 days 1 month After exposure specimen shall be recovered by drying applied according to the temperatures given in the relevant specification and durations mentioned below. Table 2 Preferred drying durations 1 h 2 h

39、 24 h The dry out temperature should be at maximum temperature of the service environment. 6.3 Fuels, lubricants, hydraulic fluids, cleaning agents and moisture repellents and anti-freeze agents Table 3 provides a non exhaustive list of recommended fluids. BS EN 61300-2-34:2009 8 61300-2-34 IEC:2009

40、(E) Table 3 List of test fluids Chemical description Test fluid code aTest temperature C A mixture of toluene (aromatic) 30 % and iso-octane (aliphatic) 70 % (V/V) Wide cut aviation turbine fuel Di-octyl sebacate (aircraft turbine engine lubrication oil) Mineral oil, viscosity approximately 15 cSt a

41、t 38 C Castor oil 20 %, ethoxyethanol 80 % (V/V) (this represents a normal hydraulic fluid) Phosphate ester hydraulic fluid (synthetic hydraulic fluid) Dimethyl silicone fluid (high temperature hydraulic fluid) Monopropylene glycol (de-icing fluid) Lithium soap/synthetic oil grease (low temperature

42、grease) Acetone White spirit, 0,79 0,81 g/ml Isopropyl alcohol Petroleum jelly, Vaseline HCl(pH2) NaOH(pH12) Kerosene Diesel fuel 10 % Nonyl Phenol Ethoxylate solution - F-34 b- O-135 b- H-544 bS-1720 bS-745 bG-395 b- - - - - - - EN 590 - 40 2 70 2 150 2 70 2 20 2 70 2 150 2 20 2 20 2 15 to 35 15 to

43、 35 15 to 35 15 to 35 15-35 15-35 15-35 15-35 50 2 aWherever possible the fluid given is specified in an International Standard or is described by its constituent chemicals. In some cases a NATO identification has been used in preference to a commercial identification. Reference to relevant commerci

44、al literature can correlate the NATO number with commercially available fluid(s). bNATO code. 7 Details to be specified The following details, as applicable, shall be specified in the relevant specification. Test fluid Specimen optically functioning or non-functioning Specimen mated or unmated (capp

45、ed or uncapped) and all spare ports sealed or capped Pre-conditioning procedure Immersion period Fluid temperature Recovery procedure, duration and temperature Initial examinations and measurements and performance requirements Final examinations and measurements and performance requirements Deviatio

46、ns from test procedure Additional pass/fail criteria BS EN 61300-2-34:200961300-2-34 IEC:2009(E) 9 Bibliography ISO 1817, Rubber, vulcanized Determination of the effect of liquids IEC 60068-2-74, Environmental testing Part 2-74: Tests Test Xc: Fluid contamination EN 590, Automotive fuels Diesel Requ

47、irements and test methods _ BS EN 61300-2-34:2009This page deliberately left blankThis page deliberately left blankBSI is the independent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Ro

48、yal Charter.British Standards Institution (BSI)raising standards worldwideBSI Group Headquarters389 Chiswick High Road London W4 4AL UKTel +44 (0)20 8996 9001Fax +44 (0)20 8996 Standards are updated by amendment or revision. Users of BritishStandards should make sure that they possess the latest am

49、endments oreditions.It is the constant aim of BSI to improve the quality of our products andservices. We would be grateful if anyone finding an inaccuracy orambiguity while using this British Standard would inform the Secretary ofthe technical committee responsible, the identity of which can be foundon the inside front cover.Tel: +44 (0)20 8996 90

展开阅读全文
相关资源
猜你喜欢
  • BS 2782-10 Method 1002-1977 Methods of testing plastics - Glass reinforced plastics - Determination of loss on ignition《塑料试验方法 第10部分 玻璃纤维增强塑料 试验方法1002 灼烧重量损失测定》.pdf BS 2782-10 Method 1002-1977 Methods of testing plastics - Glass reinforced plastics - Determination of loss on ignition《塑料试验方法 第10部分 玻璃纤维增强塑料 试验方法1002 灼烧重量损失测定》.pdf
  • BS 2782-10 Method 1003-1977 Methods of testing plastics - Glass reinforced plastics - Determination of tensile properties《塑料试验方法 第10部分 玻璃纤维增强塑料 试验方法1003 拉伸性能测定》.pdf BS 2782-10 Method 1003-1977 Methods of testing plastics - Glass reinforced plastics - Determination of tensile properties《塑料试验方法 第10部分 玻璃纤维增强塑料 试验方法1003 拉伸性能测定》.pdf
  • BS 2782-10 Method 1004-1977 Methods of testing plastics Glass reinforced plastics Standard atmospheres for conditioning and testing《塑料试验方法 第10部分 玻璃纤维增强塑料 试验方法1004 调节和试验用标准大气压》.pdf BS 2782-10 Method 1004-1977 Methods of testing plastics Glass reinforced plastics Standard atmospheres for conditioning and testing《塑料试验方法 第10部分 玻璃纤维增强塑料 试验方法1004 调节和试验用标准大气压》.pdf
  • BS 2782-10 Method 1005-1977 Methods of testing plastics Glass reinforced plastics Determination of flexural properties Three point method《塑料的试验方法 第10部分 玻璃纤维增强塑料 试验方法1005 挠曲特性测定 三点法.pdf BS 2782-10 Method 1005-1977 Methods of testing plastics Glass reinforced plastics Determination of flexural properties Three point method《塑料的试验方法 第10部分 玻璃纤维增强塑料 试验方法1005 挠曲特性测定 三点法.pdf
  • BS 2782-10 Method 1006-1978 Methods of testing plastics - Glass reinforced plastics - Determination of volatile matter and resin content of synthetic resin-impregnated textile glas.pdf BS 2782-10 Method 1006-1978 Methods of testing plastics - Glass reinforced plastics - Determination of volatile matter and resin content of synthetic resin-impregnated textile glas.pdf
  • BS 2782-11 Method 1108A-1989 Methods of testing plastics - Thermoplastics pipes fittings and valves - True impact rate (TIR) boundaries of pipes《塑料试验方法 第11部分 热塑性塑料管、接头和阀门 试验方法1108A.pdf BS 2782-11 Method 1108A-1989 Methods of testing plastics - Thermoplastics pipes fittings and valves - True impact rate (TIR) boundaries of pipes《塑料试验方法 第11部分 热塑性塑料管、接头和阀门 试验方法1108A.pdf
  • BS 2782-11 Method 1109A-1989 Methods of testing plastics - Thermoplastics pipes fittings and valves - Resistance to environmental stress cracking of polyethylene pipes and fittings.pdf BS 2782-11 Method 1109A-1989 Methods of testing plastics - Thermoplastics pipes fittings and valves - Resistance to environmental stress cracking of polyethylene pipes and fittings.pdf
  • BS 2782-11 Method 1121C-1997 Methods of testing plastics - Thermoplastics pipes fittings and valves - Thermoplastics pipes for the conveyance of fluids - Nominal outside diameters .pdf BS 2782-11 Method 1121C-1997 Methods of testing plastics - Thermoplastics pipes fittings and valves - Thermoplastics pipes for the conveyance of fluids - Nominal outside diameters .pdf
  • BS 2782-11 Method 1121H-1996 Methods of testing plastics - Thermoplastics pipes fittings and valves - Thermoplastics pipes for the transport of liquids under pressure - Calculation.pdf BS 2782-11 Method 1121H-1996 Methods of testing plastics - Thermoplastics pipes fittings and valves - Thermoplastics pipes for the transport of liquids under pressure - Calculation.pdf