EN 61300-2-49-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-49 Tests - Connector installation test《光纤互连器件和无源器件.pdf

上传人:twoload295 文档编号:720002 上传时间:2019-01-04 格式:PDF 页数:12 大小:210.57KB
下载 相关 举报
EN 61300-2-49-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-49 Tests - Connector installation test《光纤互连器件和无源器件.pdf_第1页
第1页 / 共12页
EN 61300-2-49-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-49 Tests - Connector installation test《光纤互连器件和无源器件.pdf_第2页
第2页 / 共12页
EN 61300-2-49-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-49 Tests - Connector installation test《光纤互连器件和无源器件.pdf_第3页
第3页 / 共12页
EN 61300-2-49-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-49 Tests - Connector installation test《光纤互连器件和无源器件.pdf_第4页
第4页 / 共12页
EN 61300-2-49-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-49 Tests - Connector installation test《光纤互连器件和无源器件.pdf_第5页
第5页 / 共12页
点击查看更多>>
资源描述

1、BRITISH STANDARDBS EN 61300-2-49: 2007Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-49: Tests Connector installation test The European Standard EN 61300-2-49:2007 has the status of a British StandardICS 33.180.20g49g50g3g38g50g51g60g44g49g42g

2、3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 61300-2-49:2007This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31

3、August 2007 BSI 2007ISBN 978 0 580 54313 5National forewordThis British Standard is the UK implementation of EN 61300-2-49:2007. It is identical to IEC 61300-2-49:2007.The UK participation in its preparation was entrusted by Technical Committee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre o

4、ptic interconnecting devices and passive components.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance

5、with a British Standard cannot confer immunity from legal obligations.Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARD EN 61300-2-49 NORME EUROPENNE EUROPISCHE NORM August 2007 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation El

6、ectrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61300-2-49:2007 E ICS 33.180.20 English version Fibre

7、optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-49: Tests - Connector installation test (IEC 61300-2-49:2007) Dispositifs dinterconnexion et composants passifs fibres optiques - Mthodes fondamentales dessais et de mesures - Partie 2-49: Essais -

8、Essai dinstallation de connecteur (CEI 61300-2-49:2007) Lichtwellenleiter - Verbindungselemente und passive Bauteile - Grundlegende Prf- und Messverfahren - Teil 2-49: Prfungen - Einbauprfung fr Steckverbinder (IEC 61300-2-49:2007) This European Standard was approved by CENELEC on 2007-07-01. CENELE

9、C members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on app

10、lication to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secreta

11、riat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the N

12、etherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Foreword The text of document 86B/2508/FDIS, future edition 1 of IEC 61300-2-49, prepared by SC 86B, Fibre optic interconnecting devices and passive components, of IEC TC 86, Fibre o

13、ptics, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61300-2-49 on 2007-07-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2008-04-01 la

14、test date by which the national standards conflicting with the EN have to be withdrawn (dow) 2010-07-01 Annex ZA has been added by CENELEC. _ Notice This document contains material that is Copyright 2006, Telcordia Technologies, Inc. (“Telcordia“). All rights reserved. The reader is advised that thi

15、s IEC document and Telcordia source(s) may differ, and the context and use of said material in this IEC document may differ from that of Telcordia. Telcordia makes no representation or warranty, express or implied, with respect to the sufficiency, accuracy, or utility of any information or opinion c

16、ontained herein. Any use of or reliance upon said information or opinion is at the risk of the user. Telcordia shall not be liable for any damage or injury incurred by any person arising out of the sufficiency, accuracy, or utility of any information or opinion contained herein. _ Endorsement notice

17、 The text of the International Standard IEC 61300-2-49:2007 was approved by CENELEC as a European Standard without any modification. _ EN 61300-2-49:2007 2 3 EN 61300-2-49:2007 CONTENTS 1 Scope 4 2 Normative references .4 3 General description 4 4 Apparatus.4 4.1 Mounting fixture.4 4.2 Panel 4 4.3 O

18、ptical source and detector .5 5 Procedure 5 5.1 Preparation of specimens 5 5.2 Pre-conditioning 5 5.3 Initial measurements6 5.4 Conditioning 6 5.5 Measuring the attenuation6 5.6 Applying the panel.6 5.7 Monitoring attenuation with the panel applied .6 5.8 Final measurements and examinations.6 6 Seve

19、rity6 7 Details to be specified 7 Bibliography .8 Annex ZA (normative) Normative references to international publications with their corresponding European publications9 Figure 1 Example of the connector installation test .5 Table 1 Preferred wavelengths.5 EN 61300-2-49:2007 4 FIBRE OPTIC INTERCONNE

20、CTING DEVICES AND PASSIVE COMPONENTS BASIC TEST AND MEASUREMENT PROCEDURES Part 2-49: Tests Connector installation test 1 Scope This part of IEC 61300 provides a test to determine that a connector is capable of functioning when installed in a cabinet or other enclosure in which the space available i

21、s limited. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61300-1, Fi

22、bre optic interconnecting devices and passive components Basic test and measurement procedures Part 1: General guidance IEC 61300-3-1, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-1: Examinations and measurements Visual examination IEC 61300

23、-3-4, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-4: Measurements Attenuation 3 General description The specimen is mounted into the test apparatus as shown in Figure 1. A panel is brought parallel to the mounting fixture and change in loss

24、 is measured. 4 Apparatus 4.1 Mounting fixture The mounting fixture is a vertical surface that consists of a means to hold the device under test in a stable and representative manner. For connectors the mounting fixture will incorporate an adaptor. The mounting fixture shall be capable of accommodat

25、ing those devices where the input and output fibre cables are co-located on the same side of the device. For connectors, where an adapter is used to connect two connectors, if there is more than one way to mount the adapter in the fixture, the adapter should be mounted so as to maximize the distance

26、 from the end of the connector to the panel. 4.2 Panel The panel consists of a flat surface that is brought parallel to the mounting fixture to simulate a cabinet door closing on the installed device. 5 EN 61300-2-49:2007 To detector To optical source Mounting fixture Device under test PanelFibre ca

27、ble For example, 70 mm IEC 952/07 Figure 1 Example of the connector installation test 4.3 Optical source and detector The optical source and detector used to measure changes in attenuation shall comply with that specified in IEC 61300-3-4. See Table 1 for preferred wavelengths. Table 1 Preferred wav

28、elengths Singlemode 1 310 nm and 1 550 nm, optional 1 625 nm Multimode 850 nm and 1300 nm 5 Procedure 5.1 Preparation of specimens Prepare the specimens according to the manufacturers instructions or as specified in the relevant specification. The device under test shall be terminated with a suffici

29、ent length of fibre cable to facilitate interfacing with the optical source and detector. 5.2 Pre-conditioning Pre-condition the device under test for 2 h at the standard test conditions as given in IEC 61300-1, unless otherwise specified in the relevant specification. Measure and record the attenua

30、tion of the device under test. EN 61300-2-49:2007 6 5.3 Initial measurements Complete initial examinations and measurements on the specimen as required by the relevant specification. 5.4 Conditioning Clean the connector according to the manufacturers instructions. The body of the specimen shall be m

31、ounted in a representative manner onto the mounting fixture (see Figure 1). The jumper cable that exits from the device under test is to be dressed so that about one metre of cable is supported by the end of the connector boot. 5.5 Measuring the attenuation Re-measure the attenuation to ensure that

32、the fixturing has not affected the cables attenuation. 5.6 Applying the panel Bring the panel to a position that is parallel to the mounting fixture surface and at a distance from the mounting panel as illustrated in Figure 1. 5.7 Monitoring attenuation with the panel applied The attenuation of the

33、specimen shall be measured with the panel in position, as described in IEC 61300-3-4, unless otherwise specified in the relevant specification. Any deviation in the device attenuation from that measured in 5.5 shall be considered attributable to the cable/device interface, or to fibre-to-fibre inter

34、faces in the device. 5.8 Final measurements and examinations On completion of the test, remove the panel and make a final attenuation measurement to ensure that there is no permanent damage to the device under test. Remove the device from the mounting fixture and, unless otherwise specified, visuall

35、y examine the specimen in accordance with IEC 61300-3-1. Check for evidence of any degradation in the specimen. This may include, for example: broken, loose or damaged parts or accessories; breaking or damage to the cable jacket, seals, strain relief, or fibres; displaced, bent, or broken parts; 6 S

36、everity The severity of the test is dependent upon the distance of the panel from the samples mounting position and the length of the connector. 7 EN 61300-2-49:2007 7 Details to be specified The following details, as applicable, shall be specified in the relevant specification: distance of the pane

37、l to the mounting device/fixture; initial examinations, measurements and performance requirements; examinations, measurements and performance requirements during test; final examinations, measurements and performance requirements; deviations from this test method; additional pass/fail criteria. EN 6

38、1300-2-49:2007 8 Bibliography IEC 61300-3-3, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-3: Examinations and measurements Active monitoring of changes in attenuation and return loss _ NOTE Harmonized as EN 61300-3-3:2003 (not modified). 9 E

39、N 61300-2-49:2007 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated refere

40、nces, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD YearIEC 61300-1 -1)Fibre optic interconnecting device

41、s and passive components - Basic test and measurement procedures - Part 1: General and guidance EN 61300-1 20032)IEC 61300-3-1 -1)Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1: Examinations and measurements - Visual examination EN 61300

42、-3-1 20052)IEC 61300-3-4 -1)Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation EN 61300-3-4 20012)1)Undated reference. 2)Valid edition at date of issue. BS EN 61300-2-49: 2007BSI389 Chiswick High

43、RoadLondonW4 4ALBSI British Standards InstitutionBSI is the independent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter.RevisionsBritish Standards are updated by amendment or

44、 revision. Users of British Standards should make sure that they possess the latest amendments or editions.It is the constant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using this British Standard would info

45、rm the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover. Tel: +44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400.BSI offers members an individual updating service called PLUS which ensures that subscribers automatically receive the latest edit

46、ions of standards.Buying standardsOrders for all BSI, international and foreign standards publications should be addressed to Customer Services. Tel: +44 (0)20 8996 9001. Fax: +44 (0)20 8996 7001. Email: ordersbsi-. Standards are also available from the BSI website at http:/www.bsi-.In response to o

47、rders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as British Standards, unless otherwise requested.Information on standardsBSI provides a wide range of information on national, European and international standards through its Libra

48、ry and its Technical Help to Exporters Service. Various BSI electronic information services are also available which give details on all its products and services. Contact the Information Centre. Tel: +44 (0)20 8996 7111. Fax: +44 (0)20 8996 7048. Email: infobsi-.Subscribing members of BSI are kept

49、up to date with standards developments and receive substantial discounts on the purchase price of standards. For details of these and other benefits contact Membership Administration. Tel: +44 (0)20 8996 7002. Fax: +44 (0)20 8996 7001. Email: membershipbsi-.Information regarding online access to British Standards via British Standards Online can be found

展开阅读全文
相关资源
猜你喜欢
  • BS EN 14789-2017 Stationary source emissions Determination of volume concentration of oxygen Standard reference method Paramagnetism《固定源排放 氧(O2)体积密度的测定 标准参照方法 顺磁性》.pdf BS EN 14789-2017 Stationary source emissions Determination of volume concentration of oxygen Standard reference method Paramagnetism《固定源排放 氧(O2)体积密度的测定 标准参照方法 顺磁性》.pdf
  • BS EN 14790-2017 Stationary source emissions Determination of the water vapour in ducts Standard reference method《固定源排放 管道中水蒸汽的测定 标准参照法》.pdf BS EN 14790-2017 Stationary source emissions Determination of the water vapour in ducts Standard reference method《固定源排放 管道中水蒸汽的测定 标准参照法》.pdf
  • BS EN 14791-2017 Stationary source emissions Determination of mass concentration of sulphur oxides Standard reference method《固定源排放 二氧化硫质量浓度的测定 标准参照法》.pdf BS EN 14791-2017 Stationary source emissions Determination of mass concentration of sulphur oxides Standard reference method《固定源排放 二氧化硫质量浓度的测定 标准参照法》.pdf
  • BS EN 14792-2017 Stationary source emissions Determination of mass concentration of nitrogen oxides Standard reference method Chemiluminescence《固定源排放 氧化氮(NOx)质量浓度的测定 标准参照法 化学发光》.pdf BS EN 14792-2017 Stationary source emissions Determination of mass concentration of nitrogen oxides Standard reference method Chemiluminescence《固定源排放 氧化氮(NOx)质量浓度的测定 标准参照法 化学发光》.pdf
  • BS EN 14793-2017 Stationary source emissions Demonstration of equivalence of an alternative method with a reference method《固定源排放 证明替代法和参照法的等效性》.pdf BS EN 14793-2017 Stationary source emissions Demonstration of equivalence of an alternative method with a reference method《固定源排放 证明替代法和参照法的等效性》.pdf
  • BS EN 14797-2006 Explosion venting devices《防爆泻压装置》.pdf BS EN 14797-2006 Explosion venting devices《防爆泻压装置》.pdf
  • BS EN 14798-2005 Glass packaging — Hand-held crown bottle openers — Dimensions《玻璃包装 手动冠形开瓶器 尺寸》.pdf BS EN 14798-2005 Glass packaging — Hand-held crown bottle openers — Dimensions《玻璃包装 手动冠形开瓶器 尺寸》.pdf
  • BS EN 14799-2007 Air filters for general air cleaning - Terminology《一般空气清洁用空气过滤器 术语》.pdf BS EN 14799-2007 Air filters for general air cleaning - Terminology《一般空气清洁用空气过滤器 术语》.pdf
  • BS EN 14800-2007 Corrugated safety metal hose assemblies for the connection of domestic appliances using gaseous fuels《使用气体燃料家用器具连接用波纹状安全金属软管组件》.pdf BS EN 14800-2007 Corrugated safety metal hose assemblies for the connection of domestic appliances using gaseous fuels《使用气体燃料家用器具连接用波纹状安全金属软管组件》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1