EN 61300-2-51-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-51 Tests - Fibre optic connector test for transmis.pdf

上传人:twoload295 文档编号:720005 上传时间:2019-01-04 格式:PDF 页数:12 大小:431.13KB
下载 相关 举报
EN 61300-2-51-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-51 Tests - Fibre optic connector test for transmis.pdf_第1页
第1页 / 共12页
EN 61300-2-51-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-51 Tests - Fibre optic connector test for transmis.pdf_第2页
第2页 / 共12页
EN 61300-2-51-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-51 Tests - Fibre optic connector test for transmis.pdf_第3页
第3页 / 共12页
EN 61300-2-51-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-51 Tests - Fibre optic connector test for transmis.pdf_第4页
第4页 / 共12页
EN 61300-2-51-2007 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-51 Tests - Fibre optic connector test for transmis.pdf_第5页
第5页 / 共12页
点击查看更多>>
资源描述

1、BRITISH STANDARDBS EN 61300-2-51: 2007Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-51: Tests Fibre optic connector test for transmission with applied tensile load Singlemode and multimode The European Standard EN 61300-2-51:2007 has the stat

2、us of a British StandardICS 33.180.20g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN Incorporating corrigendum January 2015BS EN 61300-2-51:20

3、07ISBN 978 0 580 89481 7Amendments/corrigenda issued since publicationDate Comments28 February 2015 Implementation of IEC corrigendum January 2015: Normative references and subclause 5.5.1 correctedThis British Standard was published under the authority of the Standards Policy and Strategy Committee

4、 on 31 August 2007 The British Standards Institution 2015. Published by BSI Standards Limited 2015National forewordThis British Standard is the UK implementation of EN 61300-2-51:2007. It is identical to IEC 61300-2-51:2007 incorporating corrigendum January 2015.The UK participation in its preparati

5、on was entrusted by Technical Committee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre optic interconnecting devices and passive components.A list of organizations represented on this committee can be obtained on request to its secretary.The publication does not purport to include all the nec

6、essary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.EUROPEAN STANDARD EN 61300-2-51 NORME EUROPENNE EUROPISCHE NORM August 2007 CENELEC European Committee for Electrotechnical Standardizat

7、ion Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2007 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61300-2-51:2007 E

8、 ICS 33.180.20 English version Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-51: Tests - Fibre optic connector test for transmission with applied tensile load - Singlemode and multimode (IEC 61300-2-51:2007) Dispositifs dinterconnexion et

9、 composantspassifs fibres optiques - Mthodes fondamentales dessais et de mesures - Partie 2-51: Essais - Essai des connecteurs fibres optiques en transmission lorsquune charge de traction est applique - Unimodal et multimodal (CEI 61300-2-51:2007) Lichtwellenleiter - Verbindungselemente und passive

10、Bauteile - Grundlegende Prf- und Messverfahren - Teil 2-51: Prfungen - Prfung fr Lichtwellenleiter-Steckverbinder mit angelegter Zugkraft - Einmoden und Mehrmoden (IEC 61300-2-51:2007) This European Standard was approved by CENELEC on 2007-07-01. CENELEC members are bound to comply with the CEN/CENE

11、LEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any C

12、ENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versio

13、ns. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania,

14、Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 61300-2-51:2007 2 Foreword The text of document 86B/2510/FDIS, future edition 1 of IEC 61300-2-51, prepared by SC 86B, Fibre optic interconnecting devices and passive components, of IEC TC 86, Fibre optics, was submitted to th

15、e IEC-CENELEC parallel vote and was approved by CENELEC as EN 61300-2-51 on 2007-07-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2008-04-01 latest date by which the nat

16、ional standards conflicting with the EN have to be withdrawn (dow) 2010-07-01 Annex ZA has been added by CENELEC. _ Notice This document contains material that is Copyright 2006, Telcordia Technologies, Inc. (“Telcordia“). All rights reserved. The reader is advised that this IEC document and Telcord

17、ia source(s) may differ, and the context and use of said material in this IEC document may differ from that of Telcordia. Telcordia makes no representation or warranty, express or implied, with respect to the sufficiency, accuracy, or utility of any information or opinion contained herein. Any use o

18、f or reliance upon said information or opinion is at the risk of the user. Telcordia shall not be liable for any damage or injury incurred by any person arising out of the sufficiency, accuracy, or utility of any information or opinion contained herein. _ Endorsement notice The text of the Internati

19、onal Standard IEC 61300-2-51:2007 was approved by CENELEC as a European Standard without any modification. _ BS EN 61300-2-51:2007EN 61300-2-51:2007 - 2 - 3 EN 61300-2-51:2007 CONTENTS 1 Scope 4 2 Normative references .4 3 General description 4 4 Apparatus 4 5 Procedure 6 5.1 General.6 5.2 Preparati

20、on of specimen6 5.3 Preconditioning .6 5.4 Initial measurements .6 5.5 Test method 6 5.6 Recovery.7 5.7 Final measurements 7 6 Details to be specified 7 Annex ZA (normative) Normative references to international publications with their corresponding European publications .8Figure 1 Test apparatus fo

21、r transmission with applied tensile load5 Figure 2 Application of the load in the case of duplex cordage5 Table 1 Preferred tensile loads and angles for transmission with applied load 6 BS EN 61300-2-51:2007EN 61300-2-51:2007- 3 -EN 61300-2-51:2007 4 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE C

22、OMPONENTS BASIC TEST AND MEASUREMENT PROCEDURES Part 2-51: Tests Fibre optic connector test for transmission with applied tensile load Singlemode and multimode 1 Scope This part of IEC 61300 describes a test to quantitatively assess the capability of fibre optic connector terminated fibre assemblies

23、 to withstand static tensile loads without uncoupling of the connector, physical damage to the assembly or degradation of optical performance. This test is intended to apply to fibre assemblies using any of the following: Media type 1: reinforced jacketed cordage of any diameter, Media type 2: cable

24、 with 900 m buffer coating that may or may not be reinforced or Media type 3: connectors terminating fibre with 250 m coating. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For u

25、ndated references, the latest edition of the referenced document (including any amendments) applies. IEC 61300-1: Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 1: General and guidance guidance IEC 61300-3-1, Fiber optic interconnecting devices

26、and passive components Basic test and measurement procedures Part 3-1: Examinations and measurements Visual examination IEC 61300-3-6, Fiber optic interconnecting devices and passive components Basic test and measurement procedures Part 3-6: Examinations and measurements Return Loss IEC 61300-3-34,

27、Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-34: Examinations and measurements - Attenuation of random mated connectors 3 General description Static loads are applied in this test to the fibre or cable of the terminated assembly while th

28、e mated connector assembly is held fixed by the adapter. The loads are applied in increments parallel to and at angles to the connector axis and held for a fixed time. The sample is measured for attenuation and return loss before application of the loads, during the application of the load at each c

29、ombination of load and angle and at the end of the test after the sequence of load and angle combinations have been applied. 4 Apparatus The apparatus for this test is shown in Figure 1. Fibre/cable tension is applied with weights through a capstan. The patchcord is flexed at the point of entrance t

30、o the connector plug by rotating the test arm. The position of the connector assembly along the test arm should be adjusted so that, when the arm is at 90, the EN 61300-2-51:2007 4 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS BASIC TEST AND MEASUREMENT PROCEDURES Part 2-51: Tests Fibre

31、 optic connector test for transmission with applied tensile load Singlemode and multimode 1 Scope This part of IEC 61300 describes a test to quantitatively assess the capability of fibre optic connector terminated fibre assemblies to withstand static tensile loads without uncoupling of the connector

32、, physical damage to the assembly or degradation of optical performance. This test is intended to apply to fibre assemblies using any of the following: Media type 1: reinforced jacketed cordage of any diameter, Media type 2: cable with 900 m buffer coating that may or may not be reinforced or Media

33、type 3: connectors terminating fibre with 250 m coating. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (incl

34、uding any amendments) applies. IEC 61300-1: Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 1: General and guidance guidance IEC 61300-3-1, Fiber optic interconnecting devices and passive components Basic test and measurement procedures Part 3-1:

35、 Examinations and measurements Visual examination IEC 61300-3-6, Fiber optic interconnecting devices and passive components Basic test and measurement procedures Part 3-6: Examinations and measurements Return Loss IEC 61300-3-34, Fibre optic interconnecting devices and passive components - Basic tes

36、t and measurement procedures - Part 3-34: Examinations and measurements - Attenuation of random mated connectors 3 General description Static loads are applied in this test to the fibre or cable of the terminated assembly while the mated connector assembly is held fixed by the adapter. The loads are

37、 applied in increments parallel to and at angles to the connector axis and held for a fixed time. The sample is measured for attenuation and return loss before application of the loads, during the application of the load at each combination of load and angle and at the end of the test after the sequ

38、ence of load and angle combinations have been applied. 4 Apparatus The apparatus for this test is shown in Figure 1. Fibre/cable tension is applied with weights through a capstan. The patchcord is flexed at the point of entrance to the connector plug by rotating the test arm. The position of the con

39、nector assembly along the test arm should be adjusted so that, when the arm is at 90, the BS EN 61300-2-51:2007EN 61300-2-51:2007 - 4 -IEC 61300-3-4, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-4: Examinations and measurements Attenuation 5

40、 EN 61300-2-51:2007 centerline along which the fibre/cable hangs, passes through the test point. The fixture is to be designed to allow the capstan to be rotated about the axis of the section of fibre/cable under tension. The bracket on which the adapter is mounted is to have provision for mounting

41、the adapter at one of the three specified angles from 0 to 135 to the axis of the connector. For transmission with applied load, angle is 0, 90 and 135 (only 90 shown) Pivot point of test arm 20 cm-28 cm Test arm Connector GuidesWeights Capstan 7,5 cm Jumper cableIEC 955/07 Figure 1 Test apparatus f

42、or transmission with applied tensile load In the case of duplex cordage, the loads shall not be doubled and the cordage shall be bent in the minor axis direction as shown in Figure 2. Load Duplex cordage IEC 954/07Figure 2 Application of the load in the case of duplex cordage BS EN 61300-2-51:2007EN

43、 61300-2-51:2007- 5 -EN 61300-2-51:2007 6 5 Procedure 5.1 General The following procedure shall be used in this test. The combinations of loads and angles to be applied at a rate of 5 N/s are those designated in the relevant specification. If these are not specified, the preferred loads and angles g

44、iven in Table 1 may be used. For small form factor connectors the preferred loads at the 90 and 135 tests are 2/3 those specified in Table 1. All optical measurements are made at singlemode 1 310 nm and 1 550 nm wavelengths and multimode 850 nm and 1 300 nm wavelengths. Optional: singlemode at 1 625

45、 nm, or as specified for the appropriate technology (for example, multimode at 650 nm). 5.2 Preparation of specimen Prepare and clean specimen in accordance with the manufacturers instructions. 5.3 Preconditioning Pre-condition the specimen for 2 h at the standard test conditions as defined in IEC 6

46、1300-1, unless otherwise specified in the relevant specification. 5.4 Initial measurements Complete initial examinations and measurements on the specimen as required by the relevant specification. 5.5 Test method 5.5.1 Measure attenuation and return loss as described in IEC 61300-3-6 and 61300-3-34

47、respectively. 5.5.2 Mount the sample in the apparatus shown in Figure 1. 5.5.3 Apply the combination of loads and angles as specified in the relevant specification beginning with 0 progressing from lowest to highest load for the appropriate media type, then repeat in order for the other angles. At e

48、ach combination of load and angle, after equilibrium is reached, measure attenuation and return loss during the test, record whether or not the connector uncouples, record whether or not damage occurs to the assembly, and, if so, record a description of the damage in accordance with IEC 61300-3-1. P

49、referred loads and angles are given in Table 1. Table 1 Preferred tensile loads and angles for transmission with applied load Media Type 1, reinforced cordage Load 0 90 135 2,4 N X X X 6,9 N X X 14,7 N X X 19,6 N X X Media Type 2, 900 m buffered coated fibre Load 0 90 135 2,4 N X X X 6,9 N X X BS EN 61300-2-51:2007EN 61300-2-51:2007 - 6 -attenuation and return loss as described in IEC 61300-3-4 and IEC 61300-3-6 respecti

展开阅读全文
相关资源
猜你喜欢
  • ASTM C1666 C1666M-2008 Standard Specification for Alkali Resistant (AR) Glass Fiber for GFRC and Fiber-Reinforced Concrete and Cement《玻璃纤维增强水泥(GFRC)和纤维增强混凝土及水泥用耐碱(AR)玻璃纤维的标准规范》.pdf ASTM C1666 C1666M-2008 Standard Specification for Alkali Resistant (AR) Glass Fiber for GFRC and Fiber-Reinforced Concrete and Cement《玻璃纤维增强水泥(GFRC)和纤维增强混凝土及水泥用耐碱(AR)玻璃纤维的标准规范》.pdf
  • ASTM C1666 C1666M-2008(2015) Standard Specification for Alkali Resistant (AR) Glass Fiber for GFRC and Fiber-Reinforced Concrete and Cement《GFRC和纤维增强混凝土及水泥用耐碱 (AR) 玻璃纤维的标准规格》.pdf ASTM C1666 C1666M-2008(2015) Standard Specification for Alkali Resistant (AR) Glass Fiber for GFRC and Fiber-Reinforced Concrete and Cement《GFRC和纤维增强混凝土及水泥用耐碱 (AR) 玻璃纤维的标准规格》.pdf
  • ASTM C1667-2007 Standard Test Method for Using Heat Flow Meter Apparatus to Measure the Center-of-Panel Thermal Resistivity of Vacuum Panels《用热流仪表器具测量真空板条中心点耐热性的标准试验方法》.pdf ASTM C1667-2007 Standard Test Method for Using Heat Flow Meter Apparatus to Measure the Center-of-Panel Thermal Resistivity of Vacuum Panels《用热流仪表器具测量真空板条中心点耐热性的标准试验方法》.pdf
  • ASTM C1667-2009 Standard Test Method for Using Heat Flow Meter Apparatus to Measure the Center-of-Panel Thermal Resistivity of Vacuum Panels《用热流仪表器具测量真空板条中心点耐热性的标准试验方法》.pdf ASTM C1667-2009 Standard Test Method for Using Heat Flow Meter Apparatus to Measure the Center-of-Panel Thermal Resistivity of Vacuum Panels《用热流仪表器具测量真空板条中心点耐热性的标准试验方法》.pdf
  • ASTM C1667-2015 Standard Test Method for Using Heat Flow Meter Apparatus to Measure the Center-of-Panel Thermal Transmission Properties of Vacuum Insulation Panels《使用热流计测量真空隔热板中心热传.pdf ASTM C1667-2015 Standard Test Method for Using Heat Flow Meter Apparatus to Measure the Center-of-Panel Thermal Transmission Properties of Vacuum Insulation Panels《使用热流计测量真空隔热板中心热传.pdf
  • ASTM C1668-2009 Standard Specification for Externally Applied Reflective Insulation Systems on Rigid Duct in Heating Ventilation and Air Conditioning (HVAC) Systems.pdf ASTM C1668-2009 Standard Specification for Externally Applied Reflective Insulation Systems on Rigid Duct in Heating Ventilation and Air Conditioning (HVAC) Systems.pdf
  • ASTM C1668-2010 Standard Specification for Externally Applied Reflective Insulation Systems on Rigid Duct in Heating Ventilation and Air Conditioning (HVAC) Systems《供暖、通风和空调(HVAC)系.pdf ASTM C1668-2010 Standard Specification for Externally Applied Reflective Insulation Systems on Rigid Duct in Heating Ventilation and Air Conditioning (HVAC) Systems《供暖、通风和空调(HVAC)系.pdf
  • ASTM C1668-2012 Standard Specification for Externally Applied Reflective Insulation Systems on Rigid Duct in Heating Ventilation and Air Conditioning (HVAC) Systems《供暖、通风和空调(HVAC)系.pdf ASTM C1668-2012 Standard Specification for Externally Applied Reflective Insulation Systems on Rigid Duct in Heating Ventilation and Air Conditioning (HVAC) Systems《供暖、通风和空调(HVAC)系.pdf
  • ASTM C1668-2013 Standard Specification for Externally Applied Reflective Insulation Systems on Rigid Duct in Heating Ventilation and Air Conditioning (HVAC) Systems《供暖、通风和空调(HVAC)系.pdf ASTM C1668-2013 Standard Specification for Externally Applied Reflective Insulation Systems on Rigid Duct in Heating Ventilation and Air Conditioning (HVAC) Systems《供暖、通风和空调(HVAC)系.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1