EN 61300-2-7-2013 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-7 Tests - Bending moment.pdf

上传人:postpastor181 文档编号:720009 上传时间:2019-01-04 格式:PDF 页数:14 大小:1.11MB
下载 相关 举报
EN 61300-2-7-2013 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-7 Tests - Bending moment.pdf_第1页
第1页 / 共14页
EN 61300-2-7-2013 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-7 Tests - Bending moment.pdf_第2页
第2页 / 共14页
EN 61300-2-7-2013 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-7 Tests - Bending moment.pdf_第3页
第3页 / 共14页
EN 61300-2-7-2013 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-7 Tests - Bending moment.pdf_第4页
第4页 / 共14页
EN 61300-2-7-2013 en Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-7 Tests - Bending moment.pdf_第5页
第5页 / 共14页
点击查看更多>>
资源描述

1、BSI Standards PublicationFibre optic interconnecting devices and passive components Basic test and measurement proceduresPart 2-7: Tests Bending momentBS EN 61300-2-7:2013National forewordThis British Standard is the UK implementation of EN 61300-2-7:2013. It is identical to IEC 61300-2-7:2013. It s

2、upersedes BS EN 61300-2-7:1997 which is withdrawn.The UK participation in its preparation was entrusted by TechnicalCommittee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre opticinterconnecting devices and passive components.A list of organizations represented on this committee can be obtaine

3、d onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2013.Published by BSI Standards Limited 2013ISBN 978 0 580 75317 6ICS 33.180.20Compliance with a B

4、ritish Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 August 2013.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 61300-2-7:2013EUROPEAN STANDARD E

5、N 61300-2-7 NORME EUROPENNE EUROPISCHE NORM July 2013 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2013 CENELEC - All rights of e

6、xploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61300-2-7:2013 E ICS 33.180.20 Supersedes EN 61300-2-7:1997 English version Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-7: Tests - Bending mome

7、nt (IEC 61300-2-7:2013) Dispositifs dinterconnexion et composants passifs fibres optiques - Procdures fondamentales dessais et de mesures - Partie 2-7: Essais - Moment de flexion (CEI 61300-2-7:2013) Lichtwellenleiter - Verbindungselemente und passive Bauteile - Grundlegende Prf- und Messverfahren -

8、 Teil 2-7: Prfungen - Biegemoment (IEC 61300-2-7:2013) This European Standard was approved by CENELEC on 2013-06-12. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard withou

9、t any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any othe

10、r language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cypru

11、s, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the

12、 United Kingdom. BS EN 61300-2-7:2013EN 61300-2-7:2013 - 2 - Foreword The text of document 86B/3579A/FDIS, future edition 2 of IEC 61300-2-7, prepared by SC 86B, “Fibre optic interconnecting devices and passive components”, of IEC TC 86, “Fibre optics” was submitted to the IEC-CENELEC parallel vote

13、and approved by CENELEC as EN 61300-2-7:2013. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2014-03-12 latest date by which the national standards conflicting with the

14、document have to be withdrawn (dow) 2014-06-12 This document supersedes EN 61300-2-7:1997. EN 61300-2-7:2013 includes the following significant technical changes with respect to EN 61300-2-7:1997: a) a complete reconsideration of the entire document, including additional normative references; b) cla

15、rification of the device under test (DUT); c) clarification of the relationship between severities, performance categories and the DUT. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsib

16、le for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 61300-2-7:2013 was approved by CENELEC as a European Standard without any modification. BS EN 61300-2-7:2013- 3 - EN 61300-2-7:2013 Annex ZA (normative) Normative references to internation

17、al publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the

18、referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 61300-3-1 - Fibre optic interconnecting devices and passive components - Bas

19、ic test and measurement procedures - Part 3-1: Examinations and measurements - Visual examination EN 61300-3-1 - IEC 61300-3-3 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-3: Examinations and measurements - Active monitoring of changes

20、 in attenuation and return loss EN 61300-3-3 - IEC 61300-3-4 - Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation EN 61300-3-4 - BS EN 61300-2-7:2013 2 61300-2-7 IEC:2013 CONTENTS 1 Scope . 5 2 No

21、rmative references . 5 3 General description 5 4 Apparatus . 5 4.1 Design for a 1 piece or 3 piece DUT . 5 4.2 Design for a 2 piece DUT 6 4.3 Optical measurements . 7 5 Procedure. 7 5.1 Preconditioning . 7 5.2 Initial examinations and measurements . 7 5.3 Conditioning for a 1 piece or 3 piece DUT .

22、7 5.4 Conditioning for a 2 piece DUT 7 5.5 Recovery . 8 5.6 Final examinations and measurements 8 6 Severity 8 7 Details to be specified 9 Annex A (informative) Example for a bending moment test method for splices . 10 Figure 1 Test apparatus to apply a bending moment to a 1 piece or 3 piece DUT. 6

23、Figure 2 Test apparatus to apply a bending moment to a 2 piece DUT . 7 Figure A.1 Example for a bending moment test set-up for splices 10 Table 1 Relationship between severities, performance categories and DUT . 8 Table 2 Severities for an 1 piece or 3 piece DUT . 9 Table 3 Severities for an 2 piece

24、 DUT 9 BS EN 61300-2-7:201361300-2-7 IEC:2013 5 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS BASIC TEST AND MEASUREMENT PROCEDURES Part 2-7: Tests Bending moment 1 Scope This part of IEC 61300 details a procedure for determining the suitability of a fibre optic device to withstand the

25、environmental condition of a bending moment which may occur in actual use, storage and/or transport. The test is primarily intended to permit the observation of effects of a bending moment. The bending moment may result in effects that would destroy functional utility, cause loss of physical strengt

26、h, and cause changes in other important mechanical properties. Degradation of optical properties may also occur. The specimen may be a component, a connector set, a splice or other device combination intended for fibre optic usage. 2 Normative references The following documents, in whole or in part,

27、 are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61300-3-1, Fibre optic interconnecting devices a

28、nd passive components Basic test and measurement procedures Part 3-1: Examinations and measurements Visual examination IEC 61300-3-3, Fibre optic interconnecting devices and passive components Basic tests and measurement procedures Part 3-3: Examinations and measurements Active monitoring of changes

29、 in attenuation and return loss IEC 61300-3-4, Fibre optic interconnecting devices and passive components Basic tests and measurement procedures Part 3-4: Examinations and measurements Attenuation 3 General description The specimen is placed in an apparatus and subjected to a bending moment which is

30、 maintained at a given temperature for a specified duration, as specified in the relevant specification. The bending moment is smoothly applied to the specimen so as to bend its longitudinal axis. 4 Apparatus 4.1 Design for a 1 piece or 3 piece DUT This design is suitable for specimens which consist

31、 of one part, like splices. The apparatus consists of the following elements: a) two steel rods placed at an appropriate distance in from the extreme ends of the DUT; BS EN 61300-2-7:2013 6 61300-2-7 IEC:2013 b) a steel finger with a defined endface radius which is placed in the middle of the suppor

32、ted DUT; c) a force generator capable of smoothly applying the specified force at the specified rate to the steel finger; d) an optional clamping device to fix the DUT; e) additional measuring equipment. If the specimen has to operate during the test, then additional equipment and operating conditio

33、ns shall be specified in the relevant specification. An example of an apparatus is shown in Figure 1. Rigid plateCBAForce FDDUTFigure 1 Test apparatus to apply a bending moment to a 1 piece or 3 piece DUT 4.2 Design for a 2 piece DUT This design is suitable for specimens which consist of two parts,

34、like connector sets. The two parts are joined together. The apparatus consists of the following elements: a) a clamping device on which the DUT, Part 1 is placed; b) a steel finger with a defined endface radius which is placed at the end of the DUT, Part 2; c) a force generator capable of smoothly a

35、pplying the specified force at the specified rate to the steel finger; d) additional measuring equipment. If the specimen has to operate during the test, then additional equipment and operating conditions shall be specified in the relevant specification. An example of an apparatus is shown in Figure

36、 2. IEC 956/13 BS EN 61300-2-7:201361300-2-7 IEC:2013 7 BAForce FDUT Part 2DUT Part 1Clamping deviceClamping deviceEFigure 2 Test apparatus to apply a bending moment to a 2 piece DUT 4.3 Optical measurements Where active monitoring is specified, measuring equipment specified in IEC 61300-3-3 shall b

37、e connected to the specimen for monitoring optical performance during the test. The optical source and detector used to measure changes in attenuation shall comply with those specified in IEC 61300-3-4. 5 Procedure 5.1 Preconditioning Maintain the specimen under standard atmospheric condition (room

38、temperature condition) for a minimum of 2 h. Clean the specimen according to the manufacturers instructions. 5.2 Initial examinations and measurements Complete initial examinations and measurements as required by the relevant specification. 5.3 Conditioning for a 1 piece or 3 piece DUT a) Apply the

39、DUT on the steel rods and securely clamp them, if necessary. b) Smoothly apply a force to the steel finger at the middle of the DUT and at the values specified in the relevant specification. c) Maintain the force for 10 s minimum. d) If required in the relevant specification, optical measurements (i

40、.e. attenuation, return loss) shall be performed and the results shall be collected. e) Where optical measurements are required during the test, measurements shall be made in accordance with IEC 61300-3-3. The relevant specification shall define the measurements and period(s) during testing after wh

41、ich they shall be carried out. The measurements shall not cause any change to the test conditions. 5.4 Conditioning for a 2 piece DUT a) Properly join the two parts of the DUT together, according to the manufacturers instruction. IEC 957/13 BS EN 61300-2-7:2013 8 61300-2-7 IEC:2013 b) Securely clamp

42、 DUT, Part 1. c) Smoothly apply a force to DUT, Part 2 at the specified point of application and at the values specified in the relevant specification. d) Maintain the force for 10 s minimum. e) If required in the relevant specification, optical measurements (i.e. attenuation, return loss) shall be

43、performed and the results shall be collected. f) Where optical measurements are required during the test, measurements shall be made in accordance with IEC 61300-3-3. The relevant specification shall define the measurements and period(s) during testing after which they shall be carried out. The meas

44、urements shall not cause any change to the test conditions. 5.5 Recovery Allow the specimen to remain under standard atmospheric conditions for a period of 10 min. 5.6 Final examinations and measurements On completion of the test, remove all fixtures. Clean the mechanical and optical alignment parts

45、 of the specimen according to the manufacturers instructions. Take final measurements as required by the relevant specification. If specified, visually examine the specimen in accordance with IEC 61300-3-1 and take any measurements specified to ensure that there is no permanent damage. 6 Severity Th

46、e severities for both methods are determined as indicated in Table 1. Table 1 Relationship between severities, performance categories and DUT DUT Operating environment Force F N Remark 1 piece or 3 piece DUT: Mechanical splices and closures Controlled C Uncontrolled U and O 2 10 For mechanical splic

47、es For closures Extreme E Aerial A Ground G Subterranean S 2 piece DUT: Connectors Controlled C Uncontrolled U and O 10 Extreme E The severity shall be given in the relevant specification. The severities according to Table 2 or Table 3 may be used for the procedure. BS EN 61300-2-7:201361300-2-7 IEC

48、:2013 9 Table 2 Severities for an 1 piece or 3 piece DUT Force F N Diameter A mm Radius B mm Diameter C mm Distance D mm Remark 2 10 30 5 The point of application shall be at the ends of the rigid part of the DUT minus 2 mm For mechanical splices 10 10 30 5 The point of application shall be at the e

49、nds of the rigid part of the DUT minus 2 mm For closures Table 3 Severities for an 2 piece DUT Force F N Diameter A mm Radius B mm Distance E mm 10 10 30 The point of application shall be at the end of the rigid part of the DUT part two minus 2 mm 7 Details to be specified The following details, as applicable, shall be specified in the relevant specification: a) Force F b) Diameter A c) Diameter B d) Diameter C e) Distance D (if applicable) f) Distance E (if a

展开阅读全文
相关资源
猜你喜欢
  • ARMY MIL-PRF-39007 10 H VALID NOTICE 1-2013 Resistor Fixed Wire-Wound (Power Type) Nonestablished Reliability Established Reliability and Space Level Style RWR84.pdf ARMY MIL-PRF-39007 10 H VALID NOTICE 1-2013 Resistor Fixed Wire-Wound (Power Type) Nonestablished Reliability Established Reliability and Space Level Style RWR84.pdf
  • ARMY MIL-PRF-39007 10 H-2008 RESISTOR FIXED WIRE-WOUND (POWER TYPE) NONESTABLISHED RELIABILITY ESTABLISHED RELIABILITY AND SPACE LEVEL STYLE RWR84《RWR84型太空级未设可靠度和已设可靠度的绕线式(电源型)固定薄膜.pdf ARMY MIL-PRF-39007 10 H-2008 RESISTOR FIXED WIRE-WOUND (POWER TYPE) NONESTABLISHED RELIABILITY ESTABLISHED RELIABILITY AND SPACE LEVEL STYLE RWR84《RWR84型太空级未设可靠度和已设可靠度的绕线式(电源型)固定薄膜.pdf
  • ARMY MIL-PRF-39007 11 J VALID NOTICE 1-2013 Resistor Fixed Wire-Wound (Power Type) Nonestablished Reliability Established Reliability and Space Level Style RWR89.pdf ARMY MIL-PRF-39007 11 J VALID NOTICE 1-2013 Resistor Fixed Wire-Wound (Power Type) Nonestablished Reliability Established Reliability and Space Level Style RWR89.pdf
  • ARMY MIL-PRF-39007 11 J-2008 RESISTOR FIXED WIRE-WOUND (POWER TYPE) NONESTABLISHED RELIABILITY ESTABLISHED RELIABILITY AND SPACE LEVEL STYLE RWR89《RWR89型太空级未设可靠度和已设可靠度的绕线式(电源型)固定薄膜.pdf ARMY MIL-PRF-39007 11 J-2008 RESISTOR FIXED WIRE-WOUND (POWER TYPE) NONESTABLISHED RELIABILITY ESTABLISHED RELIABILITY AND SPACE LEVEL STYLE RWR89《RWR89型太空级未设可靠度和已设可靠度的绕线式(电源型)固定薄膜.pdf
  • ARMY MIL-PRF-39007 12 F VALID NOTICE 1-2013 Resistor Fixed Wire-Wound (Power Type) Nonestablished Reliability established Reliability and Space Level Style RWR82.pdf ARMY MIL-PRF-39007 12 F VALID NOTICE 1-2013 Resistor Fixed Wire-Wound (Power Type) Nonestablished Reliability established Reliability and Space Level Style RWR82.pdf
  • ARMY MIL-PRF-39007 12 F-2008 RESISTOR FIXED WIRE-WOUND (POWER TYPE) NONESTABLISHED RELIABILITY ESTABLISHED RELIABILITY AND SPACE LEVEL STYLE RWR82《RWR82型太空级未设可靠度和已设可靠度的绕线式(电源型)固定薄膜.pdf ARMY MIL-PRF-39007 12 F-2008 RESISTOR FIXED WIRE-WOUND (POWER TYPE) NONESTABLISHED RELIABILITY ESTABLISHED RELIABILITY AND SPACE LEVEL STYLE RWR82《RWR82型太空级未设可靠度和已设可靠度的绕线式(电源型)固定薄膜.pdf
  • ARMY MIL-PRF-39007 5 J VALID NOTICE 1-2013 Resistor Fixed Wire-Wound(Power Type) Nonreliability Established Reliability and Space Level Style RWR71.pdf ARMY MIL-PRF-39007 5 J VALID NOTICE 1-2013 Resistor Fixed Wire-Wound(Power Type) Nonreliability Established Reliability and Space Level Style RWR71.pdf
  • ARMY MIL-PRF-39007 5 J-2008 RESISTOR FIXED WIRE-WOUND (POWER TYPE) NONESTABLISHED RELIABILITY ESTABLISHED RELIABILITY AND SPACE LEVEL STYLE RWR71《RWR71型太空级未设可靠度和已设可靠度的绕线式(电源型)固定薄膜电.pdf ARMY MIL-PRF-39007 5 J-2008 RESISTOR FIXED WIRE-WOUND (POWER TYPE) NONESTABLISHED RELIABILITY ESTABLISHED RELIABILITY AND SPACE LEVEL STYLE RWR71《RWR71型太空级未设可靠度和已设可靠度的绕线式(电源型)固定薄膜电.pdf
  • ARMY MIL-PRF-39007 6 H VALID NOTICE 1-2013 Resistor Fixed Wire-Wound (Power Type) Nonestablished Reliability Established Reliability and Space Level Style RWR74.pdf ARMY MIL-PRF-39007 6 H VALID NOTICE 1-2013 Resistor Fixed Wire-Wound (Power Type) Nonestablished Reliability Established Reliability and Space Level Style RWR74.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1