EN 61300-3-48-2013 en Fibre optic interconnect devices and passive components - Basic test and measurement procedures - Part 3-48 Examinations and measurements - Spring compression.pdf

上传人:rimleave225 文档编号:720051 上传时间:2019-01-04 格式:PDF 页数:12 大小:1.09MB
下载 相关 举报
EN 61300-3-48-2013 en Fibre optic interconnect devices and passive components - Basic test and measurement procedures - Part 3-48 Examinations and measurements - Spring compression.pdf_第1页
第1页 / 共12页
EN 61300-3-48-2013 en Fibre optic interconnect devices and passive components - Basic test and measurement procedures - Part 3-48 Examinations and measurements - Spring compression.pdf_第2页
第2页 / 共12页
EN 61300-3-48-2013 en Fibre optic interconnect devices and passive components - Basic test and measurement procedures - Part 3-48 Examinations and measurements - Spring compression.pdf_第3页
第3页 / 共12页
EN 61300-3-48-2013 en Fibre optic interconnect devices and passive components - Basic test and measurement procedures - Part 3-48 Examinations and measurements - Spring compression.pdf_第4页
第4页 / 共12页
EN 61300-3-48-2013 en Fibre optic interconnect devices and passive components - Basic test and measurement procedures - Part 3-48 Examinations and measurements - Spring compression.pdf_第5页
第5页 / 共12页
点击查看更多>>
资源描述

1、BSI Standards PublicationFibre optic interconnect devices and passive components Basic test and measurement proceduresPart 3-48: Examinations and measurements Spring compression force of the coupling sleeve for rectangular ferrule multi-fibre connectorsBS EN 61300-3-48:2013National forewordThis Brit

2、ish Standard is the UK implementation of EN 61300-3-48:2013. It isidentical to IEC 61300-3-48:2013.The UK participation in its preparation was entrusted by TechnicalCommittee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre opticinterconnecting devices and passive components.A list of organizat

3、ions represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2013.Published by BSI Standards Limited 2013ISBN

4、978 0 580 75981 9ICS 33.180.20Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 September 2013.Amendments/corrigenda issued since publicationDate Text affectedBRI

5、TISH STANDARDBS EN 61300-3-48:2013EUROPEAN STANDARD EN 61300-3-48 NORME EUROPENNE EUROPISCHE NORM September 2013 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Cen

6、tre: Avenue Marnix 17, B - 1000 Brussels 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61300-3-48:2013 E ICS 33.180.20 English version Fibre optic interconnect devices and passive components - Basic test and measurement pro

7、cedures - Part 3-48: Examinations and measurements - Spring compression force of the coupling sleeve for rectangular ferrule multi-fibre connectors (IEC 61300-3-48:2013) Dispositifs dinterconnexion et composants passifs fibres optiques - Procdures fondamentales dessais et de mesures - Partie 3-48: E

8、xamens et mesures - Force de compression du ressort du manchon de couplage des connecteurs multifibres munis de frules rectangulaires (CEI 61300-3-48:2013) Lichtwellenleiter - Verbindungselemente und passive Bauteile - Grundlegende Prf- und Messverfahren - Teil 3-48: Messungen - Federdruckkraft der

9、Kupplungshlse fr rechteckige Mehrfasersteckverbinder - Ferrulen (IEC 61300-3-48:2013) This European Standard was approved by CENELEC on 2013-08-19. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the statu

10、s of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French,

11、 German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Be

12、lgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Swed

13、en, Switzerland, Turkey and the United Kingdom. BS EN 61300-3-48:2013EN 61300-3-48:2013 - 2 - Foreword The text of document 86B/3522/CDV, future edition 1 of IEC 61300-3-48, prepared by SC 86B, “Fibre optic interconnecting devices and passive components“, of IEC TC 86, “Fibre optics“ was submitted t

14、o the IEC-CENELEC parallel vote and approved by CENELEC as EN 61300-3-48:2013. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2014-05-19 latest date by which the nationa

15、l standards conflicting with the document have to be withdrawn (dow) 2016-08-19 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endors

16、ement notice The text of the International Standard IEC 61300-3-48:2013 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 61300-3-1 NOTE Harmonised as EN 61300-3-1.

17、 IEC 61754-7 NOTE Harmonised as EN 61754-7. IEC 61754-10 NOTE Harmonised as EN 61754-10. IEC 61754-18 NOTE Harmonised as EN 61754-18. BS EN 61300-3-48:2013 2 61300-3-48 IEC:2013(E) CONTENTS 1 Scope . 5 2 Normative references . 5 3 General description 5 4 Apparatus . 5 4.1 General . 5 4.2 Fixture . 5

18、 4.3 Force transfer cup . 5 4.4 Force gauge 5 4.5 Sliding stage . 6 4.6 Observation instrument . 6 5 Procedure. 7 6 Details to be specified 7 Annex A (informative) Example of positions for MPO connector (IEC 61754-7) 8 Bibliography 9 Figure 1 Measurement of coupling sleeve compression force . 6 Figu

19、re 2 Details of force transfer 7 Figure A.1 Position of coupling sleeve before measurement 8 Figure A.2 Position of coupling sleeve during measurement . 8 BS EN 61300-3-48:201361300-3-48 IEC:2013(E) 5 FIBRE OPTIC INTERCONNECT DEVICES AND PASSIVE COMPONENTS BASIC TEST AND MEASUREMENT PROCEDURES Part

20、3-48: Examinations and measurements Spring compression force of the coupling sleeve for rectangular ferrule multi-fibre connectors 1 Scope The purpose of this part of IEC 61300 is to describe the procedure required to measure the spring compression force of the coupling sleeve for rectangular ferrul

21、e multi-fibre connectors. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced doc

22、ument (including any amendments) applies. None. 3 General description The measurement of the coupling sleeve compression force is made with the optical connector fixed. Then the coupling sleeve is moved to the stipulated position to measure the coupling sleeve compression force with a force gauge. 4

23、 Apparatus 4.1 General The apparatus consists of the following elements. See Figures 1 and 2. 4.2 Fixture The fixture shall be able to hold the optical connector without influencing the measurement of the spring compression force of the coupling sleeve. The fixture shall be able to hold the optical

24、connector with a force larger than the stipulated coupling sleeve compression force. If measurement is repeated, the location of the optical connector shall not be changed. 4.3 Force transfer cup The force transfer cup shall push only the coupling sleeve without contacting any other elements of the

25、optical connector. 4.4 Force gauge The force gauge shall be able to measure at least from 2,9 N to 6,9 N (compression force range). The force gauge is placed so that its pushing direction is the same as the coupling sleeve steering direction. BS EN 61300-3-48:2013 6 61300-3-48 IEC:2013(E) 4.5 Slidin

26、g stage The sliding stage shall not impede the location of the force gauge (4.4) and should be placed so that it can move in the same direction as the coupling sleeve. 4.6 Observation instrument The observation instrument shall have sufficient magnification to verify that the coupling sleeve is loca

27、ted at the stipulated location within a 0,1 mm margin. Coupling sleeve Force transfer cup Force gauge Sliding stage Fixture IEC 1604/13 Figure 1a Top view Observation instrument Sliding stage Force gauge Coupling sleeve Force transfer cup Fixture IEC 1605/13 Figure 1b Side view Figure 1 Measurement

28、of coupling sleeve compression force BS EN 61300-3-48:201361300-3-48 IEC:2013(E) 7 Force transfer cup Coupling sleeve IEC 1607/13 IEC 1606/13 Figure 2a Top view Figure 2b Perspective view Figure 2 Details of force transfer 5 Procedure The procedure is as follows: a) Set the optical connector under t

29、est into the fixture. b) Have the pushing part contact the edge of the coupling sleeve under test and confirm that it is located such that only the coupling sleeve is pushed, checking that the force transfer cup does not interfere with the optical connector. c) Set the observation instrument to conf

30、irm that the coupling sleeve is properly compressed to the intended position. d) Use the force gauge to set the force transfer cup and coupling sleeve at the measurement position. Confirm the location of the coupling sleeve with the observation instrument. When the edge of the coupling sleeve is wit

31、hin a 0,1 mm range from the measurement position, read the value of the force gauge. 6 Details to be specified The following details, as applicable, shall be stated in the relevant specification: maximum allowed compression force for the force gauge; pre-conditioning procedure; recovery procedure; a

32、cceptance/failure criteria; number of times the test is performed on each component; any deviation from measuring procedure; measurement uncertainty. BS EN 61300-3-48:2013 8 61300-3-48 IEC:2013(E) Annex A (informative) Example of positions for MPO connector (IEC 61754-7) Coupling sleeve endface Z(Me

33、chanical reference plane) IEC 1608/13 Figure A.1a Side view ZCoupling sleeve endface IEC 1609/13 Figure A.1b Top view Figure A.1 Position of coupling sleeve before measurement ZIEC 1610/13 Figure A.2a Side view Coupling sleeve endface (in the range of 0 m to 0,1 mm to the rig or to the left of datum

34、 Z) ZIEC 1611/13 Figure A.2b Top view Figure A.2 Position of coupling sleeve during measurement BS EN 61300-3-48:201361300-3-48 IEC:2013(E) 9 Bibliography IEC 61300-3-1, Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-1: Examinations and measur

35、ements Visual examination IEC 61754-7, Fibre optic interconnecting devices and passive components Fibre optic connector interfaces Part 7: Type MPO connector family IEC 61754-10, Fibre optic interconnecting devices and passive components Fibre optic connector interfaces Part 10: Type Mini-MPO connec

36、tor family IEC 61754-18, Fibre optic interconnecting devices and passive components Fibre optic connector interfaces Part 18: Type MT-RJ connector family _ BS EN 61300-3-48:2013This page deliberately left blankBSI is the national body responsible for preparing British Standards and other standards-r

37、elated publications, information and services.BSI is incorporated by Royal Charter. British Standards and other standardization products are published by BSI Standards Limited.British Standards Institution (BSI)BSI Group Headquarters389 Chiswick High Road London W4 4AL UKAbout usWe bring together bu

38、siness, industry, government, consumers, innovators and others to shape their combined experience and expertise into standards -based solutions.The knowledge embodied in our standards has been carefully assembled in a dependable format and refined through our open consultation process. Organizations

39、 of all sizes and across all sectors choose standards to help them achieve their goals.Information on standardsWe can provide you with the knowledge that your organization needs to succeed. Find out more about British Standards by visiting our website at or contacting our Customer Services team or

40、Knowledge Centre.Buying standardsYou can buy and download PDF versions of BSI publications, including British and adopted European and international standards, through our website at where hard copies can also be purchased. If you need international and foreign standards from other Standards Develo

41、pment Organizations, hard copies can be ordered from our Customer Services team.SubscriptionsOur range of subscription services are designed to make using standards easier for you. For further information on our subscription products go to British Standards Online (BSOL) youll have instant access t

42、o over 55,000 British and adopted European and international standards from your desktop. Its available 24/7 and is refreshed daily so youll always be up to date. You can keep in touch with standards developments and receive substantial discounts on the purchase price of standards, both in single co

43、py and subscription format, by becoming a BSI Subscribing Member. PLUS is an updating service exclusive to BSI Subscribing Members. You will automatically receive the latest hard copy of your standards when theyre revised or replaced. To find out more about becoming a BSI Subscribing Member and the

44、benefits of membership, please visit a Multi-User Network Licence (MUNL) you are able to host standards publications on your intranet. Licences can cover as few or as many users as you wish. With updates supplied as soon as theyre available, you can be sure your documentation is current. For furthe

45、r information, email .RevisionsOur British Standards and other publications are updated by amendment or revision. We continually improve the quality of our products and services to benefit your business. If you find an inaccuracy or ambiguity within a British Standard or other BSI publication please

46、 inform the Knowledge Centre.CopyrightAll the data, software and documentation set out in all British Standards and other BSI publications are the property of and copyrighted by BSI, or some person or entity that owns copyright in the information used (such as the international standardization bodie

47、s) and has formally licensed such information to BSI for commercial publication and use. Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means electronic, photocopying, recording or

48、otherwise without prior written permission from BSI. Details and advice can be obtained from the Copyright & Licensing Department.Useful Contacts:Customer ServicesTel: +44 845 086 9001Email (orders): Email (enquiries): SubscriptionsTel: +44 845 086 9001Email: Knowledge CentreTel: +44 20 8996 7004Email: Copyright & LicensingTel: +44 20 8996 7070Email: NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1