1、BRITISH STANDARDBS EN 61754-7:2008Fibre optic interconnecting devices and passive components Fibre optic connector interfaces Part 7: Type MPO connector familyICS 33.180.20g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51
2、g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 61754-7:2008This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 October 2008 BSI 2008ISBN 978 0 580 57566 2National forewordThis British Standard is the UK implement
3、ation of EN 61754-7:2008. It is identical to IEC 61754-7:2008. It supersedes BS EN 61754-7:2005 which is withdrawn. The UK participation in its preparation was entrusted by Technical Committee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre optic interconnecting devices and passive components.
4、A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from
5、legal obligations.Amendments/corrigenda issued since publicationDate CommentsEUROPEAN STANDARD EN 61754-7 NORME EUROPENNE EUROPISCHE NORM June 2008 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische
6、 Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61754-7:2008 E ICS 33.180.20 Supersedes EN 61754-7:2005English version Fibre optic interconnecting devices an
7、d passive components - Fibre optic connector interfaces - Part 7: Type MPO connector family (IEC 61754-7:2008) Dispositifs dinterconnexion et composants passifs fibres optiques - Interfaces de connecteurs pour fibres optiques - Partie 7: Famille de connecteurs de type MPO (CEI 61754-7:2008) Lichtwel
8、lenleiter -Verbindungselemente und passive Bauteile - Steckgesichter von Lichtwellenleiter-Steckverbindern - Teil 7: Steckverbinderfamilie der Bauart MPO (IEC 61754-7:2008) This European Standard was approved by CENELEC on 2008-04-01. CENELEC members are bound to comply with the CEN/CENELEC Internal
9、 Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC membe
10、r. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC
11、members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Sl
12、ovenia, Spain, Sweden, Switzerland and the United Kingdom. Foreword The text of document 86B/2581/CDV, future edition 3 of IEC 61754-7, prepared by SC 86B, Fibre optic interconnecting devices and passive components, of IEC TC 86, Fibre optics, was submitted to the IEC-CENELEC parallel vote and was a
13、pproved by CENELEC as EN 61754-7 on 2008-04-01. This European Standard supersedes EN 61754-7:2005. Specific technical changes involve the addition of an aligned key adaptor interface definition to address all existing MPO applications The following dates were fixed: latest date by which the EN has t
14、o be implemented at national level by publication of an identical national standard or by endorsement (dop) 2009-01-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2011-04-01 The International Electrotechnical Commission (IEC) and CENELEC draw attent
15、ion to the fact that it is claimed that compliance with this document may involve the use of a patent concerning MPO connectors. The IEC and CENELEC take no position concerning the evidence, validity and scope of this patent right. The holder of this patent right has assured the IEC that he/she is w
16、illing to negotiate licences under reasonable and non-discriminatory terms and conditions with applicants throughout the world. In this respect, the statement of the holder of this patent right is registered with the IEC. Information may be obtained from: Intellectual Property Department, Nippon Tel
17、egraph and Telephone Corporation, 20-2 Nishi-shinjuku 3-Chome Shinjukuku, Tokyo 163-14, Japan. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights other than those identified above. IEC and CENELEC shall not be held responsible for ide
18、ntifying any or all such patent rights. _ Endorsement notice The text of the International Standard IEC 61754-7:2008 was approved by CENELEC as a European Standard without any modification. _ BS EN 61754-7:2008 2 CONTENTS 1 Scope.4 2 Description .4 3 Interfaces .4 Figure 1 MPO connector configuratio
19、ns 5 Figure 2 MPO female plug connector angled interface 6 Figure 3 Optical datum target location diagrams .8 Figure 4 Gauge pin.10 Figure 5 Gauge for plug11 Figure 6 MPO male plug connector angled interface .12 Figure 7 MPO adaptor interface14 Figure 8 MPO female plug connector flat interface16 Fig
20、ure 9 MPO male plug connector flat interface.18 Figure 10 MPO backplane housing interface 20 Figure 11 MPO printed board housing interface 23 Figure 12 MPO aligned key adaptor interface26 Table 1 Dimensions of the MPO female plug connector angled interface.7 Table 2 Dimensions of the gauge pin10 Tab
21、le 3 Dimensions of the gauge for plug.11 Table 4 Dimensions of the MPO male plug connector angled interface13 Table 5 Dimensions of the MPO adaptor interface 15 Table 6 Dimensions of the MPO female plug connector flat interface 17 Table 7 Dimensions of the MPO male plug connector flat interface .19
22、Table 8 Dimensions of the MPO backplane housing22 Table 9 Grade 23 Table 10 Dimensions of the MPO printed board housing interface.25 Table 11 Dimensions of the MPO aligned key adaptor interface 27 BS EN 61754-7:2008 3 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS FIBRE OPTIC CONNECTOR I
23、NTERFACES Part 7: Type MPO connector family 1 Scope This part of IEC 61754 defines the standard interface dimensions for type MPO family of connectors. 2 Description The parent connector for type MPO connector family is a multiway plug connector charac-terized by a rectangular ferrule normally 6,4 m
24、m 2,5 mm which utilizes two pins of 0,7 mm diameter as its alignment. It is applicable to a joint of multiple fibres up to 12 fibres by arraying them between two pin-positioning holes in the ferrule. Furthermore, it is capable of joining up to 24 fibres by arraying them with a two layer arrangement.
25、 The connector includes a push-pull coupling mechanism and a ferrule spring loaded in the direction of the optical axis. The connector has a single male key which may be used to orient and limit the relative position between the connector and the component to which it is mated. Connector interfaces
26、are configured using a female plug without pins, a male plug with pins fixed and an adaptor as shown in Figure 1. The female plug is intermateable with the male plug. Moreover, connector interfaces between the female plug and the male plug are configured by applying a backplane housing and a printed
27、 board housing instead of the adaptor. 3 Interfaces This standard contains the following standard interfaces: Interface 7-1: MPO female plug connector angled interface Push/pull consisting of: Interface 7-1-1 for 2 to 12 fibres Interface 7-1-2 for 16 to 24 fibres Interface 7-2: MPO male plug connect
28、or angled interface Push/pull consisting of: Interface 7-2-1 for 2 to 12 fibres Interface 7-2-2 for 16 to 24 fibres Interface 7-3: MPO adaptor interface Push/pull Interface 7-4: MPO female plug connector flat interface Push/pull consisting of: Interface 7-4-1 for 2 to 12 fibres Interface 7-4-2 for 1
29、6 to 24 fibres Interface 7-5: MPO male plug connector flat interface Push/pull consisting of: Interface 7-5-1 for 2 to 12 fibres Interface 7-5-2 for 16 to 24 fibres Interface 7-6: MPO backplane housing interface Self-retaining Interface 7-7: MPO printed board housing interface Self-retaining BS EN 6
30、1754-7:2008 4 Interface 7-8: MPO adaptor interface Push/pull, aligned key configuration The following standards are intermateable: Female plugs Adaptors/housings Male plugs 7-1-1 7-3 7-2-1 7-1-2 7-3 7-2-2 7-4-1 7-3 and 7-8 7-5-1 7-4-2 7-3 and 7-8 7-5-2 7-1-1 7-6 and 7-7 7-2-1 7-1-2 7-6 and 7-7 7-2-2
31、 7-4-1 7-6 and 7-7 7-5-1 7-4-2 7-6 and 7-7 7-5-2 NOTE Connector interfaces among 2 to 12 fibres will intermate and will correctly align the lower defined numbers of optical datum targets. Also connector interfaces among 16 to 24 fibres will intermate and will correctly align the lower defined number
32、s of optical datum targets. Female plug Male plug AdaptorBackplane housingPrinted board housingIEC 1065/2000 Figure 1 MPO connector configurations BS EN 61754-7:2008 5 See Figure 3 A E F G H Pin-holes Coupling sleeve Z I JK ACABAAL M C D S Y X R Q P O N T U ADIEC 395/08 Figure 2 MPO female plug conn
33、ector angled interface BS EN 61754-7:2008 6 Table 1 Dimensions of the MPO female plug connector angled interface Dimensions Reference Minimum Maximum Notes A C D E F G H I J K L M N O P Q R S T U AA AB AC AD 0,699 mm 4,597 mm 6,3 mm 8,34 mm 9,49 mm 10,85 mm 12,19 mm 8,8 mm 7,9 mm 1,4 mm 0,2 mm 2,4 m
34、m 2,8 mm 4,89 mm 5,59 mm 5,7 mm 2,9 mm 2,4 mm 42 7,5 0,701 mm 4,603 mm 6,5 mm 8,54 mm 9,59 mm 11,05 mm 12,59 mm 9,2 mm 8,1 mm 0,8 mm 2,6 mm 3,0 mm 4,99 mm 5,69 mm 7,7 mm 3,1 mm 0,8 mm 2,5 mm 45 45 45 8,5 1 2 3 4 and 5 NOTE 1 Each pin-hole must accept a gauge pin as shown in Figure 4 to a depth of 5,
35、5 mm with a maximum force of 1,7 N. In addition, two pin-holes of a plug must accept a gauge as shown in Figure 5 to a depth of 5,5 mm with a maximum force of 3,4 N. NOTE 2 Dimension C is defined as the distance between two pin-hole centres. NOTE 3 Dimension I is given for a fibre endface centre of
36、a plug end when not mated. It is noticed that a ferrule is movable by a certain axial compression force, and therefore dimension I is variable. Ferrule compression force must be 7,8 N to 11,8 N when a position of the fibre endface from the datum Z is in the range of 8,2 mm to 8,4 mm. NOTE 4 Coupling
37、 sleeve must be movable by a certain axial compression force. Dimension L is given for a coupling sleeve end when not mated. Coupling sleeve compression force must be 2,9 N to 6,9 N when a position of the coupling sleeve endface from datum Z is in the range of 0 mm to 0,1 mm to the right or to the l
38、eft of datum Z. NOTE 5 An adaptor coupling part must be unlocked by a left-direction movement of a coupling sleeve, when it is separate from an adaptor. When the coupling sleeve is moved for unlocking, a position of the coupling sleeve endface must be larger than 2,0 mm in the left direction from th
39、e datum Z. BS EN 61754-7:2008 7 1,375 1,375 1,125 1,125 0,875 0,875 0,375 0,375 0,125 0,125 0,625 0,625 Twelve fibres Y X 1,125 1,125 0,875 0,875 0,375 0,375 0,125 0,125 0,625 0,625 Ten fibres YX 0,375 0,375 0,125 0,125 Four fibres Y X 0,125 0,125 Two fibres Y X 0,8750,875 0,375 0,375 0,125 0,125 0,
40、625 0,625 Eight fibres Y X IEC 1594/04 Figure 3 Optical datum target location diagrams (1 of 2) BS EN 61754-7:2008 8 0,125 0,125 1,125 1,125 0,875 0,875 0,375 0,375 0,625 0,625 Twenty fibres Y X 0,250 0,2500,125 0,1250,875 0,875 0,375 0,375 0,625 0,625 Sixteen fibres YX 0,250 0,250 0,125 0,125 1,375
41、 1,375 1,125 1,125 0,875 0,875 0,375 0,375 0,625 0,625 Twenty four fibres Y X 0,250 0,250 IEC 1595/04 NOTE The optical datum target location diagram is shown in the figure. Here, datum X is defined as the line passing through two pin-hole centres, and datum Y is defined as the line perpendicular to
42、datum X and passing through the midpoint of two pin-hole centres. Figure 3 (2 of 2) BS EN 61754-7:2008 9 0,0005 BC B BB BA A IEC 1596/04 Figure 4 Gauge pin Table 2 Dimensions of the gauge pin Dimensions mm Reference Minimum Maximum Notes A B BA BB BC 0,698 5 10,8 0,2 0,2 6,0 0,699 0 11,2 0,4 0,5 1 2
43、 NOTE 1 Surface roughness Rz= 0,1 m for the length of dimension BC. NOTE 2 Typical dimensions. BS EN 61754-7:2008 10 0,001 WWBAADCBB BC 0,000 5 U IEC 396/08 Figure 5 Gauge for plug Table 3 Dimensions of the gauge for plug Dimensions mm Reference Minimum Maximum Notes A C D U BA BB BC 0,698 5 4,599 5
44、 6,3 2,4 0,2 0,2 6,0 0,699 0 4,600 5 6,5 2,5 0,4 0,5 6,5 For two pins, 1 2 2 NOTE 1 Surface roughness Rz= 0,1 m. NOTE 2 Typical dimensions. BS EN 61754-7:2008 11 0,002 W W ABB U EFGHBAT Guide-pin Guide-pin Coupling sleeve See Figure 3 Z K I J AC AB AA L M C D S X Y R Q P O N AD CAIEC 397/08 Figure 6
45、 MPO male plug connector angled interface BS EN 61754-7:2008 12 Table 4 Dimensions of the MPO male plug connector angled interface Dimensions Reference Minimum Maximum Notes A C D E F G H I J K L M N O P Q R S T U AA AB AC AD BA BB CA 0,697 mm 4,597 mm 6,3 mm 8,34 mm 9,49 mm 10,85 mm 12,19 mm 8,8 mm
46、 7,9 mm 1,4 mm 0,2 mm 2,4 mm 2,8 mm 4,89 mm 5,59 mm 5,7 mm 2,9 mm 2,4 mm 42 7,5 0,2 mm 0,2 mm 1,6 mm 0,699 mm 4,603 mm 6,5 mm 8,54 mm 9,59 mm 11,05 mm 12,59 mm 9,2 mm 8,1 mm 0,8 mm 2,6 mm 3,0 mm 4,99 mm 5,69 mm 7,7 mm 3,1 mm 0,8 mm 2,5 mm 45 45 45 8,5 0,4 mm 0,5 mm 3,3 mm 1 2 3 4 and 5 6 NOTE 1 Each
47、 guide pin must be retained with a minimum force of 19,6 N. Surface roughness Rzmust be below 0,5 m. NOTE 2 Dimension C is defined as the distance between two guide-pin centres. NOTE 3 Dimension I is given for a fibre endface centre of a plug end when not mated. It is noticed that a ferrule is movab
48、le by a certain axial compression force, and therefore the dimension I is variable. Ferrule compression force must be 7,8 N to 11,8 N when a position of the fibre endface from the datum Z is in the range of 8,2 mm to 8,4 mm. NOTE 4 Coupling sleeve must be movable by a certain axial compression force
49、. Dimension L is given for a coupling sleeve end when not mated. Coupling sleeve compression force must be 2,9 N to 6,9 N when a position of the coupling sleeve endface from datum Z is in the range of 0 mm to 0,1 mm to the right or to the left of datum Z. NOTE 5 An adaptor coupling part must be unlocked by a left-direction movement of a coupling sleeve, when it is separate from an a