1、raising standards worldwide NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BSI Standards Publication Fibre optic connector optical interfaces Part 3-1: Optical interface, 2,5 mm and 1,25 mm diameter cylindrical full zirconia PC ferrule, single mode fibre BS EN 61755-3-1:2009
2、Incorporating corrigendum January 2009 National foreword This British Standard is the UK implementation of EN 61755-3-1:2009. It was derived by CENELEC from IEC 61755-3-1:2006, incorporating corrigendum January 2009. The CENELEC common modifications have been implemented at the appro- priate places
3、in the text and are indicated by tags (e.g. ). The UK participation in its preparation was entrusted by Technical Committee GEL/86, Fibre optics, to Subcommittee GEL/86/2, Fibre optic interconnecting devices and passive components. A list of organizations represented on this committee can be obtaine
4、d on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. BSI 2010 ISBN 978 0 580 53573 4 ICS 33.180.20 Compliance with a British Standard cannot confer immunity from legal obligations. T
5、his British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 March 2010. Amendments/corrigenda issued since publication Date Text affected BRITISH STANDARD BS EN 61755-3-1:2009The start and finish of text introduced or altered by corrigendum is indicate
6、d in the text by tags. Text altered by IEC corrigendum January 2009 is indicated in the text by . EUROPEAN STANDARD EN 61755-3-1 NORME EUROPENNE EUROPISCHE NORM February 2009 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches K
7、omitee fr Elektrotechnische Normung Central Secretariat: avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61755-3-1:2009 E ICS 33.180.20 English version Fibre optic connector optical interfa
8、ces - Part 3-1: Optical interface, 2,5 mm and 1,25 mm diameter cylindrical full zirconia PC ferrule, single mode fibre (IEC 61755-3-1:2006, modified + corrigendum 2009) Interfaces optiques de connecteurs pour fibres optiques - Partie 3-1: Interfaces optiques, frules PC en zircone plein cylindrique d
9、e diamtre 2,5 mm et 1,25 mm, fibres unimodales (CEI 61755-3-1:2006, modifie + corrigendum 2009) Optische Schnittstellen fr Lichtwellenleiter-Steckverbinder - Teil 3-1: Optische Schnittstellen mit nicht abgeschrgten Zirkonium-Ferrulen mit 2,5 mm und 1,25 mm Durchmesser fr Einmodenfasern mit physikali
10、schem Kontakt (IEC 61755-3-1:2006, modifiziert + Corrigendum 2009) This European Standard was approved by CENELEC on 2008-12-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national sta
11、ndard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any ot
12、her language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Repu
13、blic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 61755-3-1:2009EN 61755-3-1:2009 - 2 - For
14、eword The text of the International Standard IEC 61755-3-1:2006, prepared by SC 86B, Fibre optic interconnecting devices and passive components, of IEC TC 86, Fibre optics, together with the common modifications prepared by the Technical Committee CENELEC TC 86BXA, Fibre optic interconnect, passive
15、and connectorised components, was submitted to the formal vote and was approved by CENELEC as EN 61755-3-1 on 2008-12-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2009-
16、12-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2011-12-01 _ Endorsement notice The text of the International Standard IEC 61755-3-1:2006 + corrigendum January 2009 was approved by CENELEC as a European Standard with agreed common modifications. B
17、S EN 61755-3-1:2009 7 FIBRE OPTIC CONNECTOR OPTICAL INTERFACES Part 3-1: Optical interface, 2,5 mm and 1,25 mm diameter cylindrical full zirconia PC ferrule, single mode fibre 1 Scope This part of IEC 61755 defines certain dimensional limits of a 2,5 mm and a 1,25 mm diameter cylindrical zirconia (Z
18、rO 2 ) PC ferrule optical interface to meet specific requirements for fibre- to-fibre interconnection. Ferrules made from the material specified in this document are suitable for use in categories C, U, E, and O as defined in IEC 61753-1. Ferrule dimensions and features are contained in the IEC 6175
19、4 series of fibre optic connector interface documents. 2 Description The performance of a cylindrical ferrule optical interface is determined by the accuracy with which the optical datum targets of two mating ferrules are aligned with each other. There are three conditions affecting the alignment of
20、 two optical datum targets: lateral offset, angular offset and longitudinal offset. Parameters influencing the lateral and angular offset of the optical fibre axes include the following: ferrule outside diameter; fibre hole concentricity relative to the ferrule outside diameter; fibre hole angle rel
21、ative to outside diameter axis; fibre cladding diameter relative to fibre hole clearance; alignment sleeve inside diameter; fibre core concentricity relative to the cladding diameter; fibre core orientation relative to keying feature. Parameters influencing the longitudinal offset of the optical fib
22、re axes include the following: end-face spherical radius; end-face spherical radius apex offset; fibre undercut; axial force on ferrule end-face; ferrule and fibre material physical constants; alignment sleeve frictional force. BS EN 61755-3-1:2009 EN 61755-3-1:2009 9 3 Interface parameters The opti
23、cal interface dimensions are shown in Figure 1, the ferrule dimensions in Figure 3, while Figure 2 underlines fibre core location. The parameter values are detailed in Tables 1, 2 and 3. C A D E B IEC 1313/06 Figure 1 Interface dimensions BS EN 61755-3-1:2009 EN 61755-3-1:2009 11 F F H G IEC 1314/06 IEC 1315/06 a) Grades B and C b) Grade D F, G and H define the radial and angular polar coordinate limits of the optical fibre core relative to the optical datum of the ferrule. Figure 2 Fibre core location BS EN 61755-3-1:2009 EN 61755-3-1:2009