EN 62209-2-2010 en Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models instrumentation and procedures - Part 2 Pr.pdf

上传人:吴艺期 文档编号:721053 上传时间:2019-01-04 格式:PDF 页数:118 大小:2.52MB
下载 相关 举报
EN 62209-2-2010 en Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models instrumentation and procedures - Part 2 Pr.pdf_第1页
第1页 / 共118页
EN 62209-2-2010 en Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models instrumentation and procedures - Part 2 Pr.pdf_第2页
第2页 / 共118页
EN 62209-2-2010 en Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models instrumentation and procedures - Part 2 Pr.pdf_第3页
第3页 / 共118页
EN 62209-2-2010 en Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models instrumentation and procedures - Part 2 Pr.pdf_第4页
第4页 / 共118页
EN 62209-2-2010 en Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models instrumentation and procedures - Part 2 Pr.pdf_第5页
第5页 / 共118页
点击查看更多>>
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 62209-2:2010Human exposure to radiofrequency fields from hand-held and bodymountedwireless communicationdevices Human models,instrumentation, andproceduresPart 2: Procedure

2、 to determine thespecific absorption rate (SAR) forwireless communication devices usedin close proximity to the human body(frequency range of 30 MHz to 6 GHz) (IEC62209-2:2010)BS EN 62209-2:2010 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 62209-2:2010.The UK

3、 participation in its preparation was entrusted to TechnicalCommittee GEL/106, Human exposure to low frequency and highfrequency electromagnetic radiation.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all

4、 the necessaryprovisions of a contract. Users are responsible for its correctapplication. BSI 2010ISBN 978 0 580 60039 5ICS 17.220.20; 33.050.10Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Poli

5、cy and Strategy Committee on 31 August 2010.Amendments/corrigenda issued since publicationDate Text affectedIt is identical to IEC 62209-2:2010, incorporating corrigendum June 2010. The start and finish of text introduced or altered by corrigendum is indicated in the text by tags. Text altered by IE

6、C corrigendum June 2010is indicated in the text by .EUROPEAN STANDARD EN 62209-2 NORME EUROPENNE EUROPISCHE NORM June 2010 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centr

7、e: Avenue Marnix 17, B - 1000 Brussels 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 62209-2:2010 E ICS 33.050.10 English version Human exposure to radio frequency fields from hand-held and body-mounted wireless communicati

8、on devices - Human models, instrumentation, and procedures - Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz) (IEC 62209-2:2010) Exposition humaine aux champs radio frqu

9、ence produits par les dispositifs de communications sans fils tenus la main ou ports prs du corps - Modles du corps humain, instrumentation et procdures - Partie 2: Procdure pour la dtermination du dbit dabsorption spcifique produit par les dispositifs de communications sans fils utiliss trs prs du

10、corps humain (gamme de frquence de 30 MHz 6 GHz) (CEI 62209-2:2010) Sicherheit von Personen in hochfrequenten Feldern von handgehaltenen und am Krper getragenen schnurlosen Kommunikationsgerten Krpermodelle, Messgerte und Verfahren Teil 2: Verfahren zur Bestimmung der spezifischen Absorptionsrate (S

11、AR) von schnurlosen Kommunikationsgerten, die in enger Nachbarschaft zum menschlichen Krper verwendet werden (Frequenzbereich von 30 MHz bis 6 GHz) (IEC 62209-2:2010) This European Standard was approved by CENELEC on 2010-06-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regul

12、ations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. Thi

13、s European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC member

14、s are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia,

15、 Slovenia, Spain, Sweden, Switzerland and the United Kingdom. - 2 - Foreword The text of document 106/195/FDIS, future edition 1 of IEC 62209-1, prepared by IEC TC 106, Methods for the assessment of electric, magnetic and electromagnetic fields associated with human exposure, was submitted to the IE

16、C-CENELEC parallel vote and was approved by CENELEC as EN 62209-2 on 2010-06-01. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be held responsible for identifying any or all such patent rights. The foll

17、owing dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2011-03-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2013-06-01 Annex ZA has been

18、added by CENELEC. _ Endorsement notice The text of the International Standard IEC 62209-2:2010 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: 30 IEC 62311:2007 NOTE

19、Harmonized as EN 62311:2008 (modified). 31 IEC 62479 NOTE Harmonized as EN 62479. 34 ISO 10012:2003 NOTE Harmonized as EN ISO 10012:2003 (not modified). _ BS EN 62209-2:2010EN 62209-2:2010- 3 - Annex ZA (normative) Normative references to international publications with their corresponding European

20、publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publicati

21、on has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 62209-1 2005 Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - P

22、art 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close proximity to the ear (frequency range of 300 MHz to 3 GHz) EN 62209-1 2006 ISO/IEC 17025 2005 General requirements for the competence of testing and calibration laboratories EN ISO/IEC 17025 2005 BS

23、EN 62209-2:2010EN 62209-2:2010 2 CONTENTS FOREWORD.5 INTRODUCTION.7 1 Scope.8 2 Normative references .8 3 Terms and definitions .9 4 Symbols and abbreviated terms12 4.1 Physical quantities 12 4.2 Constants12 4.3 Abbreviations 12 5 Measurement system specifications .13 5.1 General requirements13 5.2

24、Phantom specifications shell and liquid 14 5.2.1 General requirements 14 5.2.2 Phantom material, shape and size .14 5.2.3 Tissue-equivalent liquid material properties .15 5.3 Measurement instrumentation system specifications .17 5.3.1 General requirements 17 5.3.2 Scanning system .17 5.3.3 Probes.17

25、 5.3.4 Probe calibration .17 5.3.5 Specifications for fixture(s) to hold the DUT in the test position .17 6 Protocol for SAR evaluation18 6.1 Measurement preparation18 6.1.1 General preparation.18 6.1.2 System check 18 6.1.3 Preparation of the device under test 18 6.1.4 Position of the device under

26、test in relation to the phantom .20 6.1.5 Test frequencies30 6.2 Tests to be performed .30 6.2.1 General requirements 30 6.2.2 Test reductions30 6.2.3 General test procedure31 6.2.4 Fast SAR evaluations 32 6.3 Measurement procedure34 6.3.1 General procedure.34 6.3.2 Procedures for testing of DUTs wi

27、th simultaneous multi-band transmission 35 6.4 Post-processing 37 6.4.1 Interpolation 37 6.4.2 Probe offset extrapolation37 6.4.3 Definition of averaging volume.37 6.4.4 Searching for the maxima38 7 Uncertainty estimation38 7.1 General considerations38 7.1.1 Concept of uncertainty estimation38 7.1.2

28、 Type A and type B evaluations 38 BS EN 62209-2:2010EN 62209-2:2010 3 7.1.3 Degrees of freedom and coverage factor .39 7.2 Components contributing to uncertainty.40 7.2.1 General .40 7.2.2 Contribution of the measurement system (probe and associated electronics)40 7.2.3 Contribution of mechanical co

29、nstraints 46 7.2.4 Contribution of physical parameters.49 7.2.5 Contribution of post-processing .53 7.2.6 Standard source offset and tolerance 57 7.3 Uncertainty estimation.58 7.3.1 Combined and expanded uncertainties 58 7.3.2 Maximum expanded uncertainty 58 8 Measurement report .64 8.1 General .64

30、8.2 Items to be recorded in the measurement report64 Annex A (informative) Phantom rationale .66 Annex B (normative) SAR measurement system verification 69 Annex C (informative) Fast SAR testing .78 Annex D (informative) Standard sources and phantoms for system validation 80 Annex E (informative) Ex

31、ample recipes for phantom tissue-equivalent liquids86 Annex F (normative) SAR correction for deviations of complex permittivity from targets.89 Annex G (informative) Hands-free kit testing91 Annex H (informative) Skin enhancement factor.94 Annex I (informative) Tissue-equivalent liquid dielectric pr

32、operty measurements and measurement uncertainty estimation.98 Annex J (informative) Testing compliance for the exposure of the hand .100 Annex K (informative) Test reduction .102 Annex L (normative) Power scaling procedure .104 Annex M (informative) Rationale for probe parameters 106 Bibliography108

33、 Figure 1 Dimensions of the elliptical phantom 15 Figure 2 Definition of reference points .21 Figure 3 Measurements by shifting of the device at the phantom .22 Figure 4 Test positions for a generic device .23 Figure 5 Test positions for body-worn devices .24 Figure 6 Device with swivel antenna (exa

34、mple of desktop device)24 Figure 7 Test positions for body supported devices26 Figure 8 Test positions for desktop devices .27 Figure 9 Test positions for front-of-face devices.28 Figure 10 Test position for limb-worn devices 29 Figure 11 Test position for clothing-integrated wireless devices.30 Fig

35、ure 12 Block diagram of the tests to be performed 33 Figure 13 Orientation of the probe with respect to the normal of the phantom surface35 Figure B.1 Set-up for the system check71 BS EN 62209-2:2010EN 62209-2:2010 4 Figure D.1 Mechanical details of the reference dipole 82 Figure D.2 Dimensions of t

36、he flat phantom set-up used for deriving the minimal dimensions for W and L 83 Figure D.3 FDTD predicted uncertainty in the 10 g peak spatial-average SAR as a function of the dimensions of the flat phantom compared with an infinite flat phantom 84 Figure D.4 Standard waveguide source85 Figure G.1 Co

37、nfiguration of a wired personal hands-free headset 91 Figure G.2 Configuration without a wired personal hands-free headset 92 Figure H.1 SAR and temperature increase (T) distributions simulated for a three-layer (skin, fat, muscle) planar torso model.94 Figure H.2 Statistical approach to protect 90

38、% of the population95 Figure H.3 Spatial-average SAR skin enhancement factors96 Figure J.1 Test position for hand-held devices, not used at the head or torso 100 Table 1 Dielectric properties of the tissue-equivalent liquid material 16 Table 2 Example uncertainty template and example numerical value

39、s for relative permittivity (r) and conductivity () measurement; separate tables may be needed for each rand .50 Table 3 Parameters for reference function f1.54 Table 4 Reference SAR values in watts per kilogram used for estimating post-processing uncertainties .55 Table 5 Measurement uncertainty ev

40、aluation template for DUT SAR test .59 Table 6 Measurement uncertainty evaluation template for system validation 61 Table 7 Measurement uncertainty evaluation template for system repeatability63 Table B.1 Numerical reference SAR values for reference dipoles and flat phantom All values are normalized

41、 to a forward power of 1 W.76 Table B.2 Numerical reference SAR values for reference matched waveguides in contact with flat phantom (from reference 53) .77 Table D.1 Mechanical dimensions of the reference dipoles 81 Table D.2 Parameters used for calculation of reference SAR values in Table B.1 84 T

42、able D.3 Mechanical dimensions of the standard waveguide85 Table E.1 Suggested recipes for achieving target dielectric parameters .87 Table F.1 Root-mean-squared error of Equations (F.1) to (F.3) as a function of the maximum change in permittivity or conductivity 1390 Table H.1 Spatial-average SAR c

43、orrection factors96 Table I.1 Parameters for calculating the dielectric properties of various reference liquids.98 Table I.2 Dielectric properties of reference liquids at 20 C99 Table M.1 Minimum probe requirements as a function of frequency and parameters of the tissue equivalent liquid106 Table M.

44、2 Extrapolation and integration uncertainty of the 10 g peak spatial average SAR (k=2) for homogeneous and graded meshes .107 BS EN 62209-2:2010EN 62209-2:2010 5 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ HUMAN EXPOSURE TO RADIO FREQUENCY FIELDS FROM HAND-HELD AND BODY-MOUNTED WIRELESS COMMUNICATIO

45、N DEVICES HUMAN MODELS, INSTRUMENTATION, AND PROCEDURES Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz) FOREWORD 1) The International Electrotechnical Commission (IEC)

46、is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition t

47、o other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in

48、 the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with condi

49、tions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and ar

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1