EN 62386-206-2009 en Digital addressable lighting interface - Part 206 Particular requirements for control gear - Conversion from digital signal into d c voltage (device type 5)《数字.pdf

上传人:sumcourage256 文档编号:721302 上传时间:2019-01-04 格式:PDF 页数:28 大小:1.42MB
下载 相关 举报
EN 62386-206-2009 en Digital addressable lighting interface - Part 206 Particular requirements for control gear - Conversion from digital signal into d c voltage (device type 5)《数字.pdf_第1页
第1页 / 共28页
EN 62386-206-2009 en Digital addressable lighting interface - Part 206 Particular requirements for control gear - Conversion from digital signal into d c voltage (device type 5)《数字.pdf_第2页
第2页 / 共28页
EN 62386-206-2009 en Digital addressable lighting interface - Part 206 Particular requirements for control gear - Conversion from digital signal into d c voltage (device type 5)《数字.pdf_第3页
第3页 / 共28页
EN 62386-206-2009 en Digital addressable lighting interface - Part 206 Particular requirements for control gear - Conversion from digital signal into d c voltage (device type 5)《数字.pdf_第4页
第4页 / 共28页
EN 62386-206-2009 en Digital addressable lighting interface - Part 206 Particular requirements for control gear - Conversion from digital signal into d c voltage (device type 5)《数字.pdf_第5页
第5页 / 共28页
点击查看更多>>
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationDigital addressable lighting interface Part 206: Particular requirements for control gear Conversion from digital signal into d.c. voltage (devicetype 5)BS EN 62386-206:2009Natio

2、nal forewordThis British Standard is the UK implementation of EN 62386-206:2009. It isidentical to IEC 62386-206:2009.The UK participation in its preparation was entrusted by Technical CommitteeCPL/34, Lamps and related equipment, to Subcommittee CPL/34/3, Auxiliariesfor lamps.A list of organization

3、s represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2010ISBN 978 0 580 57541 9ICS 29.140.50; 29.140.99Compliance with a British Standa

4、rd cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy and Strategy Committee on 31 Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 62386-206:2009January 2010EUROPEAN STANDARD EN 62386-206 NOR

5、ME EUROPENNE EUROPISCHE NORM November 2009 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: Avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitati

6、on in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 62386-206:2009 E ICS 29.140.50; 29.140.99 English version Digital addressable lighting interface - Part 206: Particular requirements for control gear - Conversion from digital signal into d. c. voltage (device type 5

7、) (IEC 62386-206:2009) Interface dclairage adressable numrique - Partie 206: Exigences particulires pour les appareillages de commande - Conversion du signal numrique en tension continue (dispositifs de type 5) (CEI 62386-206:2009) Digital adressierbare Schnittstelle fr die Beleuchtung - Teil 206: B

8、esondere Anforderungen an Betriebsgerte - Umwandlung des digitalen Signals in eine Gleichspannung (Gertetyp 5) (IEC 62386-206:2009) This European Standard was approved by CENELEC on 2009-09-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditio

9、ns for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three

10、 official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical

11、 committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and th

12、e United Kingdom. BS EN 62386-206:2009EN 62386-206:2009 - 2 - Foreword The text of document 34C/820/CDV, future edition 1 of IEC 62386-206, prepared by SC 34C, Auxiliaries for lamps, of IEC TC 34, Lamps and related equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC

13、 as EN 62386-206 on 2009-09-01. This standard is to be used in conjunction with EN 62386-101 and EN 62386-102, which contain general requirements for the relevant product type (control gear or control devices). The following dates were fixed: latest date by which the EN has to be implemented at nati

14、onal level by publication of an identical national standard or by endorsement (dop) 2010-06-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2012-09-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC

15、 62386-206:2009 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60598-1 NOTE Harmonized as EN 60598-1:2008 (modified). IEC 60669-2-1 NOTE Harmonized as EN 60669-2

16、-1:2004 (modified). IEC 60921 NOTE Harmonized as EN 60921:2004 (not modified). IEC 60923 NOTE Harmonized as EN 60923:2005 (not modified). IEC 60925 NOTE Harmonized as EN 60925:1991 (not modified). IEC 60929 NOTE Harmonized as EN 60929:2006 (not modified). IEC 61347-1 NOTE Harmonized as EN 61347-1:20

17、08 (modified). IEC 61347-2-3 NOTE Harmonized as EN 61347-2-3:2001 (not modified). IEC 61547 NOTE Harmonized as EN 61547:1995 (not modified). CISPR 15 NOTE Harmonized as EN 55015:2006 (not modified). _ BS EN 62386-206:2009- 3 - EN 62386-206:2009 Annex ZA (normative) Normative references to internatio

18、nal publications with their corresponding European publications The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendm

19、ents) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 62386-101 2009 Digital addressable lighting interface - Part 101: General requirements - System EN 62386-101 2009 IEC

20、 62386-102 2009 Digital addressable lighting interface - Part 102: General requirements - Control gearEN 62386-102 2009 BS EN 62386-206:2009 2 62386-206 IEC:2009 CONTENTS INTRODUCTION.5 1 Scope.6 2 Normative references .6 3 Terms and definitions .6 4 General description 6 5 Electrical specifications

21、 6 6 Interface power supply .6 7 Transmission protocol structure6 8 Timing 7 9 Method of operation .7 10 Declaration of variables7 11 Definition of commands 8 12 Test procedures .13 Bibliography24 Figure 1 Application extended configuration command sequence example.9 Figure 2 Test sequence QUERY CON

22、VERTER FEATURES.14 Figure 3 Test sequence OUTPUT RANGE .15 Figure 4 Test sequence INTERNAL PULL-UP 16 Figure 5 Test sequence PHYSICAL MINIMUM .17 Figure 6 Test sequence DIMMING CURVE 18 Figure 7 Test sequence RESET CONVERTER SETTINGS.19 Figure 8 Test sequence QUERY OUTPUT LEVEL20 Figure 9 Test seque

23、nce QUERY FAILURE STATUS 21 Figure 10 Test sequence QUERY EXTENDED VERSION NUMBER.22 Figure 11 Test sequence RESERVED APPLICATION EXTENDED COMMANDS23 Table 1 Declaration of variables.8 Table 2 Summary of the application extended command set 13 BS EN 62386-206:200962386-206 IEC:2009 5 INTRODUCTION Th

24、is first edition of IEC 62386-206 is published in conjunction with IEC 62386-101 and IEC 62386-102. The division of IEC 62386 into separately published parts provides for ease of future amendments and revisions. Additional requirements will be added as and when a need for them is recognized. This In

25、ternational Standard, and the other parts that make up the IEC 62386-200 series, in referring to any of the clauses of IEC 62386-101 or IEC 62386-102, specify the extent to which such a clause is applicable and the order in which the tests are to be performed; The parts also include additional requi

26、rements, as necessary. All parts that make up the IEC 62386-200 series are self-contained and therefore do not include references to each other. Where the requirements of any of the clauses of IEC 62386-101 or IEC 62386-102 are referred to in this International Standard by the sentence “The requirem

27、ents of IEC 62386-1XX, clause n apply”, this sentence is to be interpreted as meaning that all requirements of the clause in question of Part 101 or Part 102 apply, except any which are inapplicable to the specific type of lamp control gear covered by Part 206. All numbers used in this International

28、 Standard are decimal numbers unless otherwise noted. Hexadecimal numbers are given in the format 0xVV, where VV is the value. Binary numbers are given in the format XXXXXXXXb or in the format XXXX XXXX, where X is 0 or 1; “x“ in binary numbers means “dont care“. BS EN 62386-206:2009 6 62386-206 IEC

29、:2009 DIGITAL ADDRESSABLE LIGHTING INTERFACE Part 206: Particular requirements for control gear Conversion from digital signal into d. c. voltage (device type 5) 1 Scope This International Standard specifies a protocol and test methods for the control by digital signals of electronic control gear, a

30、ssociated with the conversion from digital signal into d.c. voltage. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced do

31、cument (including any amendments) applies. IEC 62386-101:2009, Digital addressable lighting interface Part 101: General requirements System IEC 62386-102:2009, Digital addressable lighting interface Part 102: General requirements Control gear 3 Terms and definitions For the purposes of this document

32、, the terms and definitions given in Clause 3 of IEC 62386-101:2009 and Clause 3 of IEC 62386-102:2009 apply. 4 General description The requirements of Clause 4 of IEC 62386-101:2009 and Clause 4 of IEC 62386-102:2009 shall apply. 5 Electrical specifications The requirements of Clause 5 of IEC 62386

33、-101:2009 and Clause 5 of IEC 62386-102:2009 shall apply. 6 Interface power supply The requirements of Clause 6 of IEC 62386-101:2009 and Clause 6 of IEC 62386-102:2009 shall apply if a power supply is integrated with the control gear. 7 Transmission protocol structure The requirements of Clause 7 o

34、f IEC 62386-101:2009 and Clause 7 of IEC 62386-102:2009 shall apply. BS EN 62386-206:200962386-206 IEC:2009 7 8 Timing The requirements of Clause 8 of IEC 62386-101:2009 and Clause 8 of IEC 62386-102:2009 shall apply. 9 Method of operation The requirements of Clause 9 of IEC 62386-101:2009 and Claus

35、e 9 of IEC 62386-102:2009 shall apply, with the following exception: Addition to Clause 9 of IEC 62386-102:2009: 9.9 Changing of physical min level Changing the physical minimum level shall force the minimum level and maximum level to be in a valid range. If operating with the logarithmic dimming cu

36、rve, the PHYSICAL MIN LEVEL can be adjusted to allow the minimum arc power level of connected control gear to be matched to the logarithmic dimming curve of 9.1of IEC 62386-102:2009. A control gear with physical minimum arc power level of X %, requires the “PHYSICAL MIN LEVEL” to be set as follows:

37、1)1Log(325310+= Xn where n should be rounded to the nearest integer (1 to 253) and stored as “PHYSICAL MIN LEVEL”. If operating with a linear dimming curve, the PHYSICAL MIN LEVEL can be adjusted to allow the minimum arc power level of connected control gear to be matched to the linear curve as desc

38、ribed below. Control gear with physical minimum arc power level of X %, requires the “PHYSICAL MIN LEVEL” to be set as follows: 1)1,0(9,99253+= Xn Where n should be rounded to the nearest integer (1 to 253) and stored as “PHYSICAL MIN LEVEL”. If the arc power level is 0 (OFF), the output voltage sha

39、ll be 0 V (0 V 10 V mode) or 1 V (1 V 10 V mode). If the control gear contains an output switch, this shall be on except when arc power level is 0 (OFF). 10 Declaration of variables The requirements of Clause 10 of IEC 62386-101:2009 and Clause 10 of IEC 62386-102:2009 shall apply, with the followin

40、g additional variables for this device type, indicated in Table 1. BS EN 62386-206:2009 8 62386-206 IEC:2009 Table 1 Declaration of variables Variable Default value (control gear leaves the factory) Reset value Range of validity Memory a“DIMMING CURVE” 0 No change 01; (2255 reserved) 1 byte “CONVERT

41、ER FEATURES” “factory burn-in” No change 0255 1 byte ROM “FAILURE STATUS” 0000 0000 bNo change 0255 1 byte RAM “CONVERTER STATUS” 0000 0000 No change 0255 1 byte “EXTENDED VERSION NUMBER” 1 No change 0255 1 byte ROM “DEVICE TYPE” 5 No change 0254, 255 (“MASK”) 1 byte ROM “PHYSICAL MIN LEVEL” 1 No ch

42、ange 1253 1 byte aPersistent memory (storage time indefinite) if not stated otherwise. bPower-up value. 11 Definition of commands The requirements of Clause 11 of IEC 62386-101:2009 and Clause 11 of IEC 62386-102:2009 shall apply, with the following exceptions: Amendment of Clause 11 of IEC 62386-10

43、2:2009: 11.3.1 Queries related to status information Amendment: Command 146: YAAA AAA1 1001 0010 “QUERY LAMP FAILURE“ Ask if there is an analog output problem at the given address. The answer shall be “Yes” or “No”. “Yes” means the analog output is not at the correct level. “No” does not necessarily

44、 mean that no lamps have failed. If the answer is “Yes”, the lamp failure bit (see Command 144 “QUERY STATUS”) shall also be set. Command 153: YAAA AAA1 1001 1001 “QUERY DEVICE TYPE“ The answer shall be 5. Application extended commands shall be preceded by command 272 “ENABLE DEVICE TYPE 5”. A contr

45、ol gear acting as a converter to 1 V 10 V signals shall not react to application extended commands preceded by command 272 “ENABLE DEVICE TYPE X” with X 5. NOTE For device types other than 5, these commands may be used in a different way. 11.3.4 Application extended commands Replacement: BS EN 62386

46、-206:200962386-206 IEC:2009 9 11.3.4.1 Application extended configuration commands Every configuration command (224230) shall be received a second time within 100 ms before it is executed in order to reduce the probability of incorrect reception. No other commands addressing the same control gear sh

47、all be sent between these two commands, otherwise the first such command shall be ignored and the respective configuration sequence aborted. Command 272 should be sent before the two instances of the respective control command, but not repeated between them (see Figure 1). Command 272Application ext

48、ended configuration command Application extended configuration command Max. 100 msFigure 1 Application extended configuration command sequence example All values of DTR shall be checked against the values mentioned in Clause 10, RANGE OF VALIDITY. The value shall be set to the upper / lower limit if

49、 it is above / below the valid range defined in Clause 10. Command 224: YAAA AAA1 1110 0000 “SET OUTPUT RANGE TO 1 V 10V“ This command sets the output range to 1 V 10 V. Converters without this feature shall not react. Command 225: YAAA AAA1 1110 0001 “SET OUTPUT RANGE TO 010V“ This command sets the output range to 0 V 10 V. Converters without this feature shall not react. Command 226: YAAA AAA1 1110 0010 “SWITCH ON INTER