1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationDigital addressable lighting interface Part 207: Particular requirements for control gear LED modules (device type 6)BS EN 62386-207:2009National forewordThis British Standard is
2、 the UK implementation of EN 62386-207:2009. It isidentical to IEC 62386-207:2009.The UK participation in its preparation was entrusted by Technical CommitteeCPL/34, Lamps and related equipment, to Subcommittee CPL/34/3, Auxiliariesfor lamps.A list of organizations represented on this committee can
3、be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2010 ISBN 978 0 580 57542 6 ICS 29.140.50; 29.140.99Compliance with a British Standard cannot confer immunity from leg
4、al obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 2010Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 62386-207:2009EUROPEAN STANDARD EN 62386-207 NORME EUROPENNE EUROPISCHE NORM Nov
5、ember 2009 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: Avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any form and by any means
6、reserved worldwide for CENELEC members. Ref. No. EN 62386-207:2009 E ICS 29.140.50; 29.140.99 English version Digital addressable lighting interface - Part 207: Particular requirements for control gear - LED modules (device type 6) (IEC 62386-207:2009) Interface dclairage adressable numrique - Parti
7、e 207: Exigences particulires pour les appareillages de commande - Modules de DEL (dispositifs de type 6) (CEI 62386-207:2009) Digital adressierbare Schnittstelle fr die Beleuchtung - Teil 207: Besondere Anforderungen an Betriebsgerte - LED-Module (Gertetyp 6) (IEC 62386-207:2009) This European Stan
8、dard was approved by CENELEC on 2009-09-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concern
9、ing such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into it
10、s own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland,
11、Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 62386-207:2009EN 62386-207:2009 - 2 - Foreword The text of document 34C/888/FDIS, future edition 1 of IEC 62386-207, prepared
12、by SC 34C, Auxiliaries for lamps, of IEC TC 34, Lamps and related equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 62386-207 on 2009-09-01. This standard is to be used in conjunction with EN 62386-101 and EN 62386-102, which contain general requirements for
13、 the relevant product type (control gear or control devices). The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2010-06-01 latest date by which the national standards conflictin
14、g with the EN have to be withdrawn (dow) 2012-09-01 Annex ZA has been added by CENELEC. _ Endorsement notice The text of the International Standard IEC 62386-207:2009 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following not
15、es have to be added for the standards indicated: IEC 60598-1 NOTE Harmonized as EN 60598-1:2008 (modified). IEC 60669-2-1 NOTE Harmonized as EN 60669-2-1:2004 (modified). IEC 60921 NOTE Harmonized as EN 60921:2004 (not modified). IEC 60923 NOTE Harmonized as EN 60923:2005 (not modified). IEC 60925 N
16、OTE Harmonized as EN 60925:1991 (not modified). IEC 60929 NOTE Harmonized as EN 60929:2006 (not modified). IEC 61347-1 NOTE Harmonized as EN 61347-1:2008 (modified). IEC 61347-2-3 NOTE Harmonized as EN 61347-2-3:2001 (not modified). IEC 61547 NOTE Harmonized as EN 61547:1995 (not modified). IEC 6203
17、4 NOTE Harmonized as EN 62034:2006 (not modified). CISPR 15 NOTE Harmonized as EN 55015:2006 (not modified). _ BS EN 62386-207:2009- 3 - EN 62386-207:2009 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenced d
18、ocuments are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifica
19、tions, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 62386-101 2009 Digital addressable lighting interface - Part 101: General requirements - System EN 62386-101 2009 IEC 62386-102 2009 Digital addressable lighting interface - Part 102: General requirements -
20、Control gearEN 62386-102 2009 BS EN 62386-207:2009 2 62386-207 IEC:2009 CONTENTS INTRODUCTION.6 1 Scope.7 2 Normative references .7 3 Terms and definitions .7 4 General 8 5 Electrical specification8 6 Interface power supply .8 7 Transmission protocol structure8 8 Timing 8 9 Method of operation .8 10
21、 Declaration of variables10 11 Definition of commands 11 12 Test procedures .17 Annex A (informative) Examples of algorithms .43 Bibliography44 Figure 1 Application extended configuration command sequence example.11 Figure 2 “QUERY FEATURES” 18 Figure 3 “QUERY SHORT CIRCUIT”19 Figure 4 “QUERY OPEN C
22、IRCUIT” 20 Figure 5 “QUERY LOAD DECREASE”21 Figure 6 “QUERY LOAD INCREASE” .22 Figure 7 “QUERY CURRENT PROTECTOR ACTIVE: Underload” 23 Figure 8 “QUERY CURRENT PROTECTOR ACTIVE: Overload” 24 Figure 9 “QUERY THERMAL SHUT DOWN” 25 Figure 10 “QUERY THERMAL OVERLOAD”.26 Figure 11 “Query control gear info
23、rmation”.27 Figure 12 “REFERENCE SYSTEM POWER” 28 Figure 13 “REFERENCE SYSTEM POWER: 100 ms-timeout” 29 Figure 14 “REFERENCE SYSTEM POWER: Command in-between” 30 Figure 15 “REFERENCE SYSTEM POWER: 15 minutes timer” 31 Figure 16 “REFERENCE SYSTEM POWER: failed”32 Figure 17 “ENABLE / DISABLE CURRENT P
24、ROTECTOR” .33 Figure 18 “SELECT DIMMING CURVE” .34 Figure 19 “FAST FADE TIME”35 Figure 20 “Reset State / Persistent Memory”37 Figure 21 “ENABLE DEVICE TYPE: Application extended commands”.38 Figure 22 “ENABLE DEVICE TYPE: Application extended configuration commands 1”.39 Figure 23 “ENABLE DEVICE TYP
25、E: Application extended configuration commands 2”.40 Figure 24 “QUERY EXTENDED VERSION NUMBER” 41 BS EN 62386-207:200962386-207 IEC:2009 3 Figure 25 “RESERVED APPLICATION EXTENDED COMMANDS”.42 Table 1 Fast fade time .10 Table 2 Declaration of variables.10 Table 3 Summary of the application extended
26、command set 17 Table 4 Parameters for the test “REFERENCE SYSTEM POWER: Command in-between”.31 Table 5 Parameters for test “SELECT DIMMING CURVE”35 Table 6 Parameters for test “FAST FADE TIME” 36 Table 7 Parameters for test “ENABLE DEVICE TYPE: Application extended commands”.38 Table 8 Parameters fo
27、r test “ENABLE DEVICE TYPE: Application extended configuration commands 1”.40 BS EN 62386-207:2009 6 62386-207 IEC:2009 INTRODUCTION This first edition of IEC 62386-207 is published in conjunction with IEC 62386-101 and IEC 62386-102. The division of IEC 62386 into separately published parts provide
28、s for ease of future amendments and revisions. Additional requirements will be added as and when a need for them is recognised. This International Standard, and the other parts that make up the IEC 62386-200 series, in referring to any of the clauses of IEC 62386-101 or IEC 62386-102, specify the ex
29、tent to which such a clause is applicable and the order in which the tests are to be performed. The parts also include additional requirements, as necessary. All parts that make up IEC 62386-200 series are self-contained and therefore do not include references to each other. Where the requirements o
30、f any of the clauses of IEC 62386-101 or IEC 62386-102 are referred to in this International Standard by the sentence “The requirements of IEC 62386-1XX, clause n apply”, this sentence is to be interpreted as meaning that all requirements of the clause in question of Part 101 or Part 102 apply, exce
31、pt any which are inapplicable to the specific type of lamp control gear covered by Part 207. All numbers used in this International Standard are decimal numbers unless otherwise noted. Hexadecimal numbers are given in the format 0xVV, where VV is the value. Binary numbers are given in the format XXX
32、XXXXXb or in the format XXXX XXXX, where X is 0 or 1; x in binary numbers means dont care. BS EN 62386-207:200962386-207 IEC:2009 7 DIGITAL ADDRESSABLE LIGHTING INTERFACE Part 207: Particular requirements for control gear LED modules (device type 6) 1 Scope This International Standard specifies a pr
33、otocol and test procedures for the control by digital signals of electronic control gear for use on a.c. or d.c. supplies, associated with LED modules. NOTE Tests in this standard are type tests. Requirements for testing individual control gear during production are not included. 2 Normative referen
34、ces The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 62386-101:2009, Digital addressable light
35、ing interface Part 101: General requirements System IEC 62386-102:2009, Digital addressable lighting interface Part 102: General requirements Control gear 3 Terms and definitions For the purposes of this document, the terms and definitions given in Clause 3 of IEC 62386-101:2009 and Clause 3 of IEC
36、62386-102:2009 shall apply, with the following additional definitions. 3.1 reference measurement process during which control gear determines the actual LED load with internal procedures and measurements NOTE The details of this process are a matter of detailed design of control gear and are outside
37、 the scope of this standard. 3.2 detection of load decrease recognition that the actual LED load is significantly below the load measured during a successful “reference measurement” NOTE The criteria for regarding a load increase or decrease as significant can only be decided by the manufacturer and
38、 these criteria should be described in the manual. 3.3 detection of load increase recognition that the actual LED load is significantly above the load measured during a successful “reference measurement” NOTE The criteria for regarding a load increase or decrease as significant can only be decided b
39、y the manufacturer and these criteria should be described in the manual. BS EN 62386-207:2009 8 62386-207 IEC:2009 3.4 current protector protective device switching off the output if the actual LED load differs by more than P from the load detected during the “reference measurement” NOTE The value P
40、 can only be specified by the manufacturer of the control gear and this value should be stated in the manual. 3.5 thermal overload scenario where the maximum permissible control gear temperature is exceeded 3.6 thermal shut down scenario where control gear switches off the LED because of a persisten
41、t thermal overload 3.7 light level reduction due to thermal overload reduction of light level with the objective of decreasing control gear temperature 4 General The requirements of Clause 4 of IEC 62386-101:2009 and Clause 4 of IEC 62386-102:2009 apply. 5 Electrical specification The requirements o
42、f Clause 5 of IEC 62386-101:2009 and Clause 5 of IEC 62386-102:2009 apply. 6 Interface power supply The requirements of Clause 6 of IEC 62386-101:2009 and Clause 6 of IEC 62386-102:2009 apply, if a power supply is integrated with the control gear. 7 Transmission protocol structure The requirements o
43、f Clause 7 of IEC 62386-101:2009 and Clause 7 of IEC 62386-102:2009 apply. 8 Timing The requirements of Clause 8 of IEC 62386-101:2009 and Clause 8 of IEC 62386-102:2009 apply. 9 Method of operation The requirements of Clause 9 of IEC 62386-101:2009 and Clause 9 of IEC 62386-102:2009 apply, except a
44、s follows: Addition to Clause 9 of IEC 62386-102:2009: BS EN 62386-207:200962386-207 IEC:2009 9 9.9 Detection of load decrease If the actual LED load is significantly below the load measured during a successful “reference measurement”, the gear may switch off the lamp if this is necessary for its sa
45、fe operation. The flag bit load decrease is to be set. 9.10 Detection of load increase If the actual LED load is significantly above the load measured during a successful “reference measurement”, the gear may switch off if this is necessary for its safe operation. The flag bit load increase is to be
46、 set. 9.11 Current protector If the actual LED load of the control gear differs by more than a defined amount P from the load detected during the reference measurement, the current protector becomes active and switches off the LED. The current protector shall not become active until there has been a
47、 successful reference measurement. There are two possible situations in which the current protector becomes active: Overload: The actual LED load is higher than the load detected during the reference measurement by at least P. Underload: The actual LED load is lower than the load detected during the
48、 reference measurement by at least P. The current protector shall become inactive either on mains voltage interruption or on receipt of a command which causes the arc power level to be 0. If after switching on again, the situation causing the current protector to become active still remains, the cur
49、rent protector shall become active again. The current protector can be enabled and disabled by the commands 225 “ENABLE CURRENT PROTECTOR” and 226 “DISABLE CURRENT PROTECTOR”. An active current protector shall become inactive upon reception of command 226 “DISABLE CURRENT PROTECTOR”. If the current protector is active, command 224 “REFERENCE SYSTEM POWER” shall be ignored. 9.12 LED replaceme