EN 62442-2-2014 en Energy performance of lamp controlgear - Part 2 Controlgear for high intensity discharge lamps (excluding fluorescent lamps) - Method of measurement to determine.pdf

上传人:bowdiet140 文档编号:721352 上传时间:2019-01-04 格式:PDF 页数:18 大小:1.08MB
下载 相关 举报
EN 62442-2-2014 en Energy performance of lamp controlgear - Part 2 Controlgear for high intensity discharge lamps (excluding fluorescent lamps) - Method of measurement to determine.pdf_第1页
第1页 / 共18页
EN 62442-2-2014 en Energy performance of lamp controlgear - Part 2 Controlgear for high intensity discharge lamps (excluding fluorescent lamps) - Method of measurement to determine.pdf_第2页
第2页 / 共18页
EN 62442-2-2014 en Energy performance of lamp controlgear - Part 2 Controlgear for high intensity discharge lamps (excluding fluorescent lamps) - Method of measurement to determine.pdf_第3页
第3页 / 共18页
EN 62442-2-2014 en Energy performance of lamp controlgear - Part 2 Controlgear for high intensity discharge lamps (excluding fluorescent lamps) - Method of measurement to determine.pdf_第4页
第4页 / 共18页
EN 62442-2-2014 en Energy performance of lamp controlgear - Part 2 Controlgear for high intensity discharge lamps (excluding fluorescent lamps) - Method of measurement to determine.pdf_第5页
第5页 / 共18页
点击查看更多>>
资源描述

1、BSI Standards PublicationEnergy performance of lamp controlgearPart 2: Controlgear for high intensity discharge lamps (excluding fluorescent lamps) Method of measurement to determine the efficiency of controlgearBS EN 62442-2:2014National forewordThis British Standard is the UK implementation of EN

2、62442-2:2014. It isidentical to IEC 62442-2:2014.The UK participation in its preparation was entrusted by TechnicalCommittee CPL/34, Lamps and Related Equipment, to SubcommitteeCPL/34/3, Auxiliaries for lamps.A list of organizations represented on this committee can be obtained onrequest to its secr

3、etary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2014.Published by BSI Standards Limited 2014ISBN 978 0 580 80427 4ICS 29.140.99Compliance with a British Standard cannot

4、confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 June 2014.Amendments/corrigenda issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 62442-2:2014EUROPEAN STANDARD NORME EUROPENNE EUR

5、OPISCHE NORM EN 62442-2 May 2014 ICS 29.140.99 English Version Energy performance of lamp controlgear - Part 2: Controlgear for high intensity discharge lamps (excluding fluorescent lamps) - Method of measurement to determine the efficiency of the controlgear (IEC 62442-2:2014) Performance nergtique

6、 des appareillages de lampes - Partie 2: Appareillages des lampes dcharge haute intensit ( lexclusion des lampes fluorescence) - Mthode de mesure pour la dtermination du rendement des appareillages (CEI 62442-2:2014) Energieeffizienz von Lampenbetriebsgerten - Teil 2: Betriebsgerte fr Hochdruck-Entl

7、adungslampen (ausgenommen Leuchtstofflampen) - Messverfahren zur Bestimmung des Wirkungsgrades von Betriebsgerten (IEC 62442-2:2014) This European Standard was approved by CENELEC on 2014-05-22. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditi

8、ons for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exis

9、ts in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the nati

10、onal electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Por

11、tugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1

12、000 Brussels 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 62442-2:2014 E BS EN 62442-2:2014EN 62442-2:2014 - 2 - Foreword The text of document 34C/1078/FDIS, future edition 1 of IEC 62442-2, prepared by SC 34C “Auxiliaries f

13、or lamps“ of IEC/TC 34 “Lamps and related equipment“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 62442-2:2014. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or

14、 by endorsement (dop) 2015-02-22 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2017-05-22 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held

15、responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 62442-2:2014 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the stand

16、ards indicated: IEC 60188 NOTE Harmonised in EN 60188 (not modified). IEC 60662 NOTE Harmonised in EN 60662 (not modified). IEC 60923 NOTE Harmonised in EN 60923 (not modified). IEC 61167 NOTE Harmonised in EN 61167 (not modified). IEC 62035 NOTE Harmonised in EN 62035 (not modified). IEC 62442-1:20

17、11 NOTE Harmonised in EN 62442-1:2011 (not modified). IEC 62442-3 NOTE Harmonised in EN 62442-3 (not modified). BS EN 62442-2:2014- 3 - EN 62442-2:2014 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in w

18、hole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE 1 When an International Publica

19、tion has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here: www.cenelec.eu Publication Year Title EN/HD Year IEC 61347-1 (mod) 2007 Lamp controlg

20、ear - Part 1: General and safety requirements EN 61347-1 2008 +A1 2010 +A1 2011 +A2 2012 +A2 2013 IEC 61347-2-9 2012 Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps) EN 61347-2-9 2013 IEC 61347-2-12 2010 Lamp contr

21、olgear - Part 2-12: Particular requirements for d.c. or a.c. supplied electronic ballasts for discharge lamps (excluding fluorescent lamps) - - IEC Guide 115 Application of uncertainty of measurement to conformity assessment activities in the electrotechnical sector - - BS EN 62442-2:2014 2 IEC 6244

22、2-2:2014 IEC 2014 CONTENTS 1 Scope 5 2 Normative references . 5 3 Terms and definitions. 6 4 General . 7 4.1 Applicability . 7 4.2 General notes on test 7 4.3 Controllable controlgear 7 4.4 Multi-lamp type controlgear . 7 4.5 Measurement uncertainty 8 4.6 Sampling of controlgear for testing 8 4.7 Nu

23、mber of samples . 8 4.8 Power supply. 8 4.9 Supply voltage waveform . 8 4.10 Instrument accuracy 8 4.11 Multi-rated voltage controlgear 9 5 Method of measurement of the input power and calculation of the efficiency of controlgear for high intensity discharge lamps 9 5.1 Measurement setup: Electromag

24、netic wire wound controlgear 9 5.2 Efficiency calculation: Magnetic wire wound controlgear . 10 5.3 Measurement setup: Electronic controlgear . 10 5.4 Efficiency calculation: Electronic controlgear . 11 5.5 Standby power measurement of electronic controlgear 11 Bibliography 13 Figure 1 Measurement s

25、etup for electromagnetic controlgear . 9 Figure 2 Measurement setup for electronic controlgear . 10 Figure 3 Measurement setup of the standby power of electronic controlgear . 11 Table 1 Typical nominal electricity supply details for some regions 8 BS EN 62442-2:2014IEC 62442-2:2014 IEC 2014 5 ENERG

26、Y PERFORMANCE OF LAMP CONTROLGEAR Part 2: Controlgear for high intensity discharge lamps (excluding fluorescent lamps) Method of measurement to determine the efficiency of the controlgear 1 Scope This part of the IEC 62442 series defines a measurement method of the power losses of electromagnetic co

27、ntrolgear, the total input power and the standby power of electronic controlgear for high intensity discharged lamps (excluding fluorescent lamps). Also a calculation method of the efficiency for controlgear for high intensity discharged lamp(s) is defined. This International Standard applies to ele

28、ctrical controlgear lamp circuits comprised solely of the controlgear and of the lamp(s). NOTE Requirements for testing individual controlgear during production are not included. It specifies the measurement method for the total input power, the standby power and the calculation method of the lamp c

29、ontrolgear efficiency for all controlgear sold for domestic and normal commercial purposes operating with high intensity discharge lamps. This International Standard does not apply to: controlgear which form an integral part of lamps; controlgear circuits with capacitors connected in series; control

30、lable wire-wound electromagnetic controlgear. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition o

31、f the referenced document (including any amendments) applies. IEC 61347-1:2007, Lamp controlgear Part 1: General and safety requirements Amendment 1:2010 Amendment 2:2012 IEC 61347-2-9:2012, Lamp controlgear Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (exclu

32、ding fluorescent lamps) IEC 61347-2-12:2010, Lamp controlgear Part 2-12: Particular requirements for d.c. or a.c. supplied electronic ballasts for discharge lamps (excluding fluorescent lamps) IEC Guide 115:2007, Application of uncertainty of measurement to conformity assessment activities in the el

33、ectrotechnical sector BS EN 62442-2:2014 6 IEC 62442-2:2014 IEC 2014 3 Terms and definitions For the purpose of this document, the following terms and definitions apply. 3.1 nominal value suitable approximate quantity value used to designate or identify a component, device or equipment SOURCE: IEC 6

34、2442-1:2011,3.1 3.2 rated value quantity value for specified operating conditions of a component, device or equipment. The value and conditions are specified in the relevant standard or assigned by the manufacturer or responsible vendor SOURCE: IEC 62442-1:2011, 3.3, modified The note has been remov

35、ed. 3.3 controlgear one or more components between supply and one or more lamps which may serve to transform the supply voltage, limit the current of lamp(s) to the required value, provide starting voltage, correct power factor or reduce radio interference SOURCE: IEC 62442-1:2011,3.4 3.4 electromag

36、netic controlgear controlgear which by means of inductance, or a combination of inductance and capacitance, serves mainly to limit the current of lamp(s) to the required value Frequency of the lamp controlgear is the same as supply frequency SOURCE: IEC 62442-1:2011,3.5 3.5 electronic controlgear, A

37、.C. and/or D.C. supplied electronic circuit including stabilizing elements for starting and operating one or more lamp(s) 3.6 discharge lamp lamp in which the light is produced, directly or indirectly, by an electric discharge through a gas, a metal vapour or a mixture of several gases and vapours 3

38、.7 controlgear lamp circuit electrical circuit, or part thereof, normally built in a luminaire, consisting of the controlgear and lamp(s) SOURCE: IEC 62442-1:2011,3.8 3.8 standby mode mode relevant for those controlgear which are permanently connected to the mains, where the lamp(s) are switched off

39、 via a control signal, not including failed lamp(s) BS EN 62442-2:2014IEC 62442-2:2014 IEC 2014 7 Note 1 to entry: The ignition phase of lamp(s) is excluded from the standby mode. 3.9 standby power average power consumption of a controlgear when subjected to standby mode Note 1 to entry: Unit: W. 3.

40、10 total input power total power supplied to the controlgear lamp circuit measured at rated input voltage SOURCE: CEI 62442-1:2011, 3.14, modified The sentence “The rated power specified is related to a specific ballast lumen factor (BLF).“ has been removed. 3.11 lamp controlgear efficiency, MCGECGr

41、atio between the lamp power (controlgear output power) and the input power of the controlgear lamp circuit with possible sensors, network connections and other auxiliary loads disconnected 3.12 multi-lamp type controlgear controlgear designed for the operation of more than one type of lamp with diff

42、erent electrical characteristics e.g. power 4 General 4.1 Applicability The measurement and calculation methods of this International Standard shall only be used for lamp controlgear which conforms to IEC 61347-1 with IEC 61347-2-9 or IEC 61347-1 with IEC 61347-2-12. 4.2 General notes on test The me

43、asurement conditions are specified in IEC 61347-1:2007, Clauses H.1, H.2, H.4, H.8, H.9 and H.11; unless otherwise specified in this standard. The device under test (DUT) shall be placed according to IEC 61347-1:2007, Figure H.1. An A.C. voltage source shall be used to provide input voltage to the D

44、UT. During the tests, the supply voltage and the frequency shall be maintained constant within 0,5 % during the warm-up period. However, during the actual measurement, the voltage shall be adjusted to within 0,2 % of the specified testing value. 4.3 Controllable controlgear Requirements for other th

45、an 100 % light output operation of controllable controlgear and multi-tapped electromagnetic controlgear are under consideration. 4.4 Multi-lamp type controlgear If a single-lamp controlgear is designed for different lamp powers then the test shall be carried out for each lamp. The test for multi-la

46、mp controlgear shall be carried out with all possible combinations. BS EN 62442-2:2014 8 IEC 62442-2:2014 IEC 2014 4.5 Measurement uncertainty Measurement uncertainty shall be managed in accordance with the accuracy method in 4.4.3 of the IEC Guide 115:2007. 4.6 Sampling of controlgear for testing T

47、ests in this International Standard are type tests. The requirements and tolerances specified in this International Standard are based on the testing of a type test sample submitted by the manufacturer for that purpose. This sample should consist of units having characteristics typical of the manufa

48、cturers production and be as close to the production centre point values as possible. 4.7 Number of samples One specimen shall be tested. 4.8 Power supply Where the test voltage and frequency are not defined by national or regional requirements, the controlgear manufacturer shall declare the nominal

49、 voltage(s) at which the given efficiency is valid. Test voltage(s) and test frequency(ies) shall be the nominal voltage and the nominal frequency of the country or region for which the measurement is being determined (refer to Table 1). Table 1 Typical nominal electricity supply details for some regions Country or region Nominal voltage and frequency aEurope 230 V; 50 Hz North America 120 V, 277 V; 60 Hz Japan b100 V, 200 V; 50/60 Hz China 220 V; 50