EN 62541-9-2015 en OPC unified architecture - Part 9 Alarms and conditions.pdf

上传人:postpastor181 文档编号:721435 上传时间:2019-01-04 格式:PDF 页数:92 大小:1.97MB
下载 相关 举报
EN 62541-9-2015 en OPC unified architecture - Part 9 Alarms and conditions.pdf_第1页
第1页 / 共92页
EN 62541-9-2015 en OPC unified architecture - Part 9 Alarms and conditions.pdf_第2页
第2页 / 共92页
EN 62541-9-2015 en OPC unified architecture - Part 9 Alarms and conditions.pdf_第3页
第3页 / 共92页
EN 62541-9-2015 en OPC unified architecture - Part 9 Alarms and conditions.pdf_第4页
第4页 / 共92页
EN 62541-9-2015 en OPC unified architecture - Part 9 Alarms and conditions.pdf_第5页
第5页 / 共92页
点击查看更多>>
资源描述

1、BSI Standards PublicationOPC unified architecturePart 9: Alarms and conditionsBS EN 62541-9:2015National forewordThis British Standard is the UK implementation of EN 62541-9:2015. It isidentical to IEC 62541-9:2015. It supersedes BS EN 62541-9:2012 which iswithdrawn.The UK participation in its prepa

2、ration was entrusted to TechnicalCommittee AMT/7, Industrial communications: process measurement andcontrol, including fieldbus.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions o

3、fa contract. Users are responsible for its correct application. The British Standards Institution 2015.Published by BSI Standards Limited 2015ISBN 978 0 580 83008 2ICS 25.040.40; 25.100.01Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was publis

4、hed under the authority of theStandards Policy and Strategy Committee on 31 May 2015.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 62541-9:2015EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 62541-9 May 2015 ICS 25.040.40; 35.100 Supersedes EN 62541-9:201

5、2 English Version OPC unified architecture - Part 9: Alarms and conditions (IEC 62541-9:2015) Architecture unifie OPC - Partie 9: Alarmes et conditions (IEC 62541-9:2015) OPC Unified Architecture - Teil 9: Alarme und Zustnde (IEC 62541-9:2015) This European Standard was approved by CENELEC on 2015-0

6、4-29. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obt

7、ained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified

8、to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greec

9、e, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electro

10、technique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 62541-9:2015 E BS EN 62541-9:2015EN 62541-9:2015 - 2 -

11、Foreword The text of document 65E/382/CDV, future edition 2 of IEC 62541-9, prepared by SC 65E “Devices and integration in enterprise systems“, of IEC/TC 65 “Industrial-process measurement, control and automation“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 62541-9:2

12、015. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2016-01-29 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2018-

13、04-29 This document supersedes EN 62541-9:2012. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. This document has been prepared under

14、a mandate given to CENELEC by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). Endorsement notice The text of the International Standard IEC 62541-9:2015 was approved by CENELEC as a European Standard without any modification. I

15、n the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 62541-7 NOTE Harmonized as EN 62541-7. IEC 62541-11 NOTE Harmonized as EN 62541-11. BS EN 62541-9:2015- 3 - EN 62541-9:2015 Annex ZA (normative) Normative references to international publi

16、cations with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenc

17、ed document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here: w

18、ww.cenelec.eu. Publication Year Title EN/HD Year IEC/TR 62541-1 - OPC unified architecture - Part 1: Overview and concepts CLC/TR 62541-1 - IEC 62541-3 - OPC unified architecture - Part 3: Address Space Model EN 62541-3 - IEC 62541-4 - OPC Unified Architecture - Part 4: Services EN 62541-4 - IEC 625

19、41-5 - OPC unified architecture - Part 5: Information Model EN 62541-5 - IEC 62541-6 - OPC unified architecture - Part 6: Mappings EN 62541-6 - IEC 62541-8 - OPC Unified Architecture - Part 8: Data Access EN 62541-8 - EEMUA 191 Alarm systems - A guide to design, management and procurement - - BS EN

20、62541-9:2015 2 IEC 62541-9:2015 IEC 2015 CONTENTS FOREWORD . 8 1 Scope 10 2 Normative references. 10 3 Terms, definitions, and abbreviations . 10 3.1 Terms and definitions 10 3.2 Abbreviations and symbols 12 3.3 Used data types 12 4 Concepts . 12 4.1 General . 12 4.2 Conditions. 12 4.3 Acknowledgeab

21、le Conditions . 14 4.4 Previous states of Conditions 15 4.5 Condition state synchronization . 16 4.6 Severity, Quality, and Comment 16 4.7 Dialogs . 17 4.8 Alarms 17 4.9 Multiple Active States 18 4.10 Condition Instances in the Address Space . 19 4.11 Alarm and Condition Auditing 19 5 Model 19 5.1 G

22、eneral . 19 5.2 Two-State State Machines . 20 5.3 Condition Variables . 21 5.4 Substate Reference Types 22 5.4.1 General 22 5.4.2 HasTrueSubState ReferenceType . 22 5.4.3 HasFalseSubState ReferenceType . 23 5.5 Condition Model 23 5.5.1 General 23 5.5.2 ConditionType 24 5.5.3 Condition and Branch Ins

23、tances . 27 5.5.4 Disable Method 27 5.5.5 Enable Method . 28 5.5.6 AddComment Method . 28 5.5.7 ConditionRefresh Method . 29 5.6 Dialog Model . 31 5.6.1 General 31 5.6.2 DialogConditionType 31 5.6.3 Respond Method 32 5.7 Acknowledgeable Condition Model 33 5.7.1 General 33 5.7.2 AcknowledgeableCondit

24、ionType . 33 5.7.3 Acknowledge Method . 34 5.7.4 Confirm Method 35 5.8 Alarm Model 36 5.8.1 General 36 BS EN 62541-9:2015IEC 62541-9:2015 IEC 2015 3 5.8.2 AlarmConditionType . 37 5.8.3 ShelvedStateMachineType . 39 5.8.4 LimitAlarmType 43 5.8.5 ExclusiveLimit Types 44 5.8.6 NonExclusiveLimitAlarmType

25、 46 5.8.7 Level Alarm 48 5.8.8 Deviation Alarm 48 5.8.9 Rate of Change 49 5.8.10 Discrete Alarms 50 5.9 ConditionClasses 52 5.9.1 Overview 52 5.9.2 Base ConditionClassType . 52 5.9.3 ProcessConditionClassType . 53 5.9.4 MaintenanceConditionClassType 53 5.9.5 SystemConditionClassType 53 5.10 Audit Ev

26、ents . 53 5.10.1 Overview 53 5.10.2 AuditConditionEventType . 54 5.10.3 AuditConditionEnableEventType . 55 5.10.4 AuditConditionCommentEventType . 55 5.10.5 AuditConditionRespondEventType 55 5.10.6 AuditConditionAcknowledgeEventType . 55 5.10.7 AuditConditionConfirmEventType . 56 5.10.8 AuditConditi

27、onShelvingEventType 56 5.11 Condition Refresh Related Events . 56 5.11.1 Overview 56 5.11.2 RefreshStartEventType 57 5.11.3 RefreshEndEventType 57 5.11.4 RefreshRequiredEventType 57 5.12 HasCondition Reference Type . 58 5.13 Alarm and Condition Status Codes 58 5.14 Expected A any IEC National Commit

28、tee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in acco

29、rdance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all in

30、terested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held respo

31、nsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergenc

32、e between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity assessment services and, in some areas, access to IEC marks

33、 of conformity. IEC is not responsible for any services carried out by independent certification bodies. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts

34、and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publi

35、cation or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publi

36、cation may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC 62541-9 has been prepared by subcommittee 65E: Devices and integration in enterprise systems, of IEC technical committee 65: Industrial-process meas

37、urement, control and automation. This second edition cancels and replaces the first edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) added section to describe expect be

38、haviour for A b) changed the DialogConditionType to be not abstract since it is expect that instance of this type will exist in the system, see Table 19 for additonal details ref 1622; BS EN 62541-9:2015IEC 62541-9:2015 IEC 2015 9 c) updated ConditionRefresh Method to allow the use of the well know

39、NodeIds associated with the types for the MethodId and ConditionId instead of requiring the call to use only the MethodId and ConditionId that is part of an instance. Without this change, servers that do not expose instance may have problems with ConditionRefresh, see 5.5.7 for additional details re

40、f 2091; d) Fixed ExclusiveLimitStateMachineType and ShelvedStatemachineType to be sub-types of FinitStateMachineType not StateMachineType. See 5.8.3 and 5.8.5.2 for additional details ref 2091. The text of this standard is based on the following documents: CDV Report on voting 65E/382/CDV 65E/408/RV

41、C Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2. A list of all parts of the IEC 62541 series, published under the general title OP

42、C Unified Architecture, can be found on the IEC website. The committee has decided that the contents of this publication will remain unchanged until the stability date indicated on the IEC web site under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publi

43、cation will be reconfirmed, withdrawn, replaced by a revised edition, or amended. IMPORTANT The colour inside logo on the cover page of this publication indicates that it contains colours which are considered to be useful for the correct understanding of its contents. Users should therefore print th

44、is document using a colour printer. BS EN 62541-9:2015 10 IEC 62541-9:2015 IEC 2015 OPC UNIFIED ARCHITECTURE Part 9: Alarms and conditions 1 Scope This part of IEC 62541 specifies the representation of Alarms and Conditions in the OPC Unified Architecture. Included is the Information Model represent

45、ation of Alarms and Conditions in the OPC UA address space. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the la

46、test edition of the referenced document (including any amendments) applies. IEC TR 62541-1, OPC Unified Architecture Part 1: Overview and Concepts IEC 62541-3, OPC Unified Architecture Part 3: Address Space Model IEC 62541-4, OPC Unified Architecture Part 4: Services IEC 62541-5, OPC Unified Archite

47、cture Part 5: Information Model IEC 62541-6, OPC Unified Architecture Part 6: Mappings IEC 62541-8, OPC Unified Architecture Part 8: Data Access EEMUA: 2nd Edition EEMUA 191 Alarm System A guide to design, management and procurement (Appendixes 6, 7, 8, 9), available at http:/www.eemua.co.uk/ 3 Term

48、s, definitions, and abbreviations 3.1 Terms and definitions For the purposes of this document, the terms and definitions given in IEC TR 62541-1, IEC 62541-3, IEC 62541-4, and IEC 62541-5 as well as the following apply. 3.1.1 acknowledge operator action that indicates recognition of a new Alarm Note

49、 1 to entry: This definition is copied from EEMUA. The term “Accept” is another common term used to describe Acknowledge. They can be used interchangeably. This standard will use Acknowledge. 3.1.2 active state for an Alarm that indicates that the situation the Alarm is representing currently exists Note 1 to entry: Other common terms defined by EEMUA are “Standing” for an Active Alarm and “Cleared” when the Condition has returned to normal and is no longer Active. BS EN 62541-9:2015IEC 6254

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1