EN 62639-2012 en Fluorescent induction lamps - Performance specification.pdf

上传人:terrorscript155 文档编号:721509 上传时间:2019-01-04 格式:PDF 页数:72 大小:1.48MB
下载 相关 举报
EN 62639-2012 en Fluorescent induction lamps - Performance specification.pdf_第1页
第1页 / 共72页
EN 62639-2012 en Fluorescent induction lamps - Performance specification.pdf_第2页
第2页 / 共72页
EN 62639-2012 en Fluorescent induction lamps - Performance specification.pdf_第3页
第3页 / 共72页
EN 62639-2012 en Fluorescent induction lamps - Performance specification.pdf_第4页
第4页 / 共72页
EN 62639-2012 en Fluorescent induction lamps - Performance specification.pdf_第5页
第5页 / 共72页
点击查看更多>>
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationFluorescent induction lamps Performance specificationBS EN 62639:2012National forewordThis British Standard is the UK implementation of EN 62639:2012. It is identical to IEC 6263

2、9:2012.The UK participation in its preparation was entrusted by Technical CommitteeCPL/34, Lamps and Related Equipment, to Subcommittee CPL/34/1, Electriclamps.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to includ

3、e all the necessary provisions of acontract. Users are responsible for its correct application. The British Standards Institution 2012Published by BSI Standards Limited 2012ISBN 978 0 580 68411 1ICS 29.140.30 Compliance with a British Standard cannot confer immunity fromlegal obligations.This Britis

4、h Standard was published under the authority of the StandardsPolicy and Strategy Committee on 31 May 2012.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 62639:2012EUROPEAN STANDARD EN 62639 NORME EUROPENNE EUROPISCHE NORM April 2012 CENELEC European Committee for

5、 Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2012 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref

6、. No. EN 62639:2012 E ICS 29.140.30 English version Fluorescent induction lamps - Performance specification (IEC 62639:2012) Lampes fluorescentes induction - Spcification de performance (CEI 62639:2012) Leuchtstoff-Induktionslampen - Anforderungen an die Arbeitsweise (IEC 62639:2012) This European S

7、tandard was approved by CENELEC on 2012-03-27. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references conc

8、erning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC m

9、ember into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Gre

10、ece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 62639:2012EN 62639:2012 - 2 - Foreword The text of document 34A/1526/FDIS, future edit

11、ion 1 of IEC 62639, prepared by SC 34A, “Lamps“, of IEC/TC 34, “Lamps and related equipment“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 62639:2012. The following dates are fixed: latest date by which the document has to be implemented at national level by publicatio

12、n of an identical national standard or by endorsement (dop) 2012-12-27 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2015-03-27 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights.

13、 CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 62639:2012 was approved by CENELEC as a European Standard without any modification. BS EN 62639:2012- 3 - EN 62639:2012 Annex ZA (normative)

14、Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated ref

15、erences, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60081 1997 Double-capped fluorescent lamp

16、s - Performance specifications EN 60081 1998 IEC 60598-1 - Luminaires - Part 1: General requirements and tests EN 60598-1 - IEC 60929 - AC and/or DC-supplied electronic control gear for tubular fluorescent lamps - Performance requirements EN 60929 - IEC 61347-2-3 - Lamp controlgear - Part 2-3: Parti

17、cular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps EN 61347-2-3 - IEC 62532 2011 Fluorescent induction lamps - Safety specifications EN 62532 2011 BS EN 62639:2012 2 62639 IEC:2012 CONTENTS INTRODUCTION . 5 1 Scope . 6 2 Normative references . 6 3 Terms an

18、d definitions . 6 4 Lamp requirements . 7 4.1 General . 7 4.2 Marking . 8 4.2.1 General . 8 4.2.2 Correlated colour temperature (CCT) and colour rendering index (Ra) . 8 4.2.3 Polarity 8 4.3 Dimensions . 8 4.4 Starting characteristics 8 4.5 Electrical characteristics 8 4.6 Photometric characteristic

19、s . 8 4.7 Lumen maintenance 9 4.8 Life 9 5 Information for ballast design . 9 6 Information for luminaire design . 9 7 Data sheets 9 7.1 Diagrammatic data sheets for location of lamp dimensions 9 7.2 Lamp data sheets 18 7.3 Maximum outline sheets 44 Annex A (normative) Method of test for starting ch

20、aracteristics 55 Annex B (normative) Method of test for electrical and photometric characteristics 57 Annex C (normative) Method of test for lumen maintenance and life 61 Annex D (informative) Information for ballast design 62 Annex E (informative) Information for luminaire design 66 Bibliography 67

21、 Figure A.1 Test circuit for measurement of starting characteristics . 56 Figure B.1 Schematic set-up for measurement of electrical characteristics of externally coupled induction lamps and photometrical characteristics . 59 Figure B.2 Example of calorimetric set-up for measurement of power of inter

22、nally a-type coupled induction lamps 60 Figure D.1 Circuit for testing ballasts Lamp voltage, lamp current, phase shift and frequency measured at starting and during operation 63 Figure D.2 Circuit for testing ballasts Lamp voltage, current and frequency measured at starting . 64 Figure D.3 Circuit

23、for testing ballasts Lamp voltage, current, phase shift and frequency measured during operation . 65 Table A.1 Frequencies of specially prepared ballasts . 55 BS EN 62639:201262639 IEC:2012 5 INTRODUCTION Performance standard IEC 62639 follows IEC 62532:2011-01, which is the safety standard for indu

24、ction lamps. Requirements are given on marking, dimensions, starting characteristics, electrical characteristics, photometric characteristics, lumen maintenance and life. Further, information is given for designing ballasts and luminaires. The requirements are detailed by means of lamp data sheets,

25、diagrammatic data sheets and maximum lamp outline sheets. BS EN 62639:2012 6 62639 IEC:2012 FLUORESCENT INDUCTION LAMPS PERFORMANCE SPECIFICATION 1 Scope This International Standard specifies the performance requirements for fluorescent induction lamps for general lighting purposes. In this standard

26、, the term “lamp” stands for “induction lamp”. It may be expected that lamps which comply with this standard will start and operate satisfactorily at voltages between 92 % and 106 % of rated supply voltage and at an ambient air temperature between 10 C and 50 C, when operated with ballasts complying

27、 with IEC 60929 and IEC 61347-2-3, as far as applicable, and in a luminaire complying with IEC 60598-1. NOTE For some lamps, additional information for ballast design is given for proper starting at an ambient air temperature of 15 C. 2 Normative references The following documents, in whole or in pa

28、rt, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60081:1997, Double-capped fluorescent lamps P

29、erformance specifications IEC 60598-1, Luminaires Part 1: General requirements and tests IEC 60929, AC and/or DC-supplied electronic control gear for tubular fluorescent lamps Performance requirements IEC 61347-2-3, Lamp control gear Part 2-3: Particular requirements for a.c. and/or d.c. supplied el

30、ectronic control gear for fluorescent lamps IEC 62532:2011, Fluorescent induction lamps Safety specifications 3 Terms and definitions For the purposes of this document, the terms and definitions given in IEC 62532 and IEC 60081 apply, together with the following. 3.1 ambient temperature Tambaverage

31、temperature of air or another medium in the vicinity of the lamp BS EN 62639:201262639 IEC:2012 7 3.2 stabilization period time required after switching on a lamp to reach stable values of luminous flux or lamp voltage Note 1 to entry: Requirements on luminous flux are given in 4.6 and on tolerance

32、of luminous flux in Clause B.2. 3.3 reference ballast special electronic ballast, which is specified by the design specification of manufacturer It is designed for the purpose of providing comparison standards for use in testing ballasts, for the selection of reference lamps or for testing regular p

33、roduction lamps under standardized conditions. It is essentially characterized by the fact that, at its rated frequency, it has a stable voltage/current ratio which is relatively uninfluenced by variations in current, temperature and magnetic surroundings, as outlined in the relevant ballast standar

34、d. SOURCE: IEC 60050-845:1987, 845-08-36, modified 3.4 life time during which a lamp is operated until its failure Note 1 to entry: Switch-off times are not regarded when calculating life. 3.5 nominal life life (in hours) as declared by the manufacturer It is published together with the switching cy

35、cle and failure rate on which it is based. Note 1 to entry: Example for a short version: 12B10 (12 h switching cycle / 10 % failures). 4 Lamp requirements 4.1 General A lamp, on which compliance with this standard is claimed, shall comply with the requirements of IEC 62532. A lamp has to comply with

36、 further requirements or more stringent requirements, if they published by manufacturer. A lamp shall be so designed that its performance is reliable in normal and accepted use. In general, this can be achieved by satisfying the requirements of the following subclauses. The requirements and informat

37、ion given apply to 95 % of production. NOTE The requirements and tolerances permitted by this standard correspond to the testing of a type test sample, submitted by the manufacturer for that purpose. In principle, this type test sample should consist of units having characteristics typical of the ma

38、nufacturers production and being as close to the production centre point values as possible. It may be expected with the tolerances given in the standard that products manufactures in accordance with the type test sample will comply with the standard of the majority of production. Due to the product

39、ion spread however, it is inevitable that there will sometimes be products outside the specified tolerances. Measurements are carried out under reference conditions with values specified on the data sheets, if available. Except where otherwise specified in the annexes, lamps shall be tested in an am

40、bient temperature of between 20 C and 27 C. BS EN 62639:2012 8 62639 IEC:2012 4.2 Marking 4.2.1 General In addition to the marking requirements of IEC 62532, the following is specified. 4.2.2 Correlated colour temperature (CCT) and colour rendering index (Ra) The value of the correlated colour tempe

41、rature and colour rendering index shall be provided on the lamp itself or on the packaging (under consideration). The value representing CCT and Ramay take the form as given in the International Lamp Coding System (ILCOS). NOTE An Raof 80 and a CCT of 3 000 K may be combined in the abbreviation “830

42、”. 4.2.3 Polarity The polarity shall be identified by marking the terminals (+, -). Other means of identifying are possible instead, see Clause B.2. 4.3 Dimensions The dimensions of a lamp shall comply with the values specified on the relevant lamp data sheet. Compliance: By measuring with callipers

43、 or equivalent. 4.4 Starting characteristics A lamp shall start fully within the time specified on the relevant lamp data sheet and remain alight. Compliance: Visual inspection to verify that lamps are starting and remain alight. If the lamp has achieved breakdown at Uminand stayed alight, it has pa

44、ssed the test. Conditions and method of test are given in Annex A. 4.5 Electrical characteristics Requirements for lamp voltage and power are given below. a) The initial reading of the voltage at the lamp terminals shall comply with the values specified on the relevant lamp data sheet. b) The initia

45、l reading of the power dissipated by a lamp shall not exceed the rated power specified on the relevant lamp data sheet by more than 5 %. Conditions and method of test are given in Annex B. 4.6 Photometric characteristics Requirements for luminous flux, chromaticity coordinates and colour rendering i

46、ndex are given below. a) The initial reading of the luminous flux of a lamp shall be not less than 90 % and the average of a batch shall be not less than 95 % (under consideration) of the declared value. b) If specified, the initial reading of the chromaticity co-ordinates x and y of a lamp shall be

47、 within 5 SDCM (standard deviation of colour matching) from the rated values. c) The initial reading of the general colour rendering index Raof a lamp shall be not less than the rated value decreased by three. BS EN 62639:201262639 IEC:2012 9 Conditions and method of test are given in Annex B. 4.7 L

48、umen maintenance The lumen maintenance of a lamp, at any time in its life, shall be not less than 90 % of the rated lumen maintenance value. Conditions and method of test are given in Annex C. 4.8 Life Requirements are provided by the lamp manufacturer. 5 Information for ballast design Refer to the

49、relevant lamp data sheet and to Annex D for information for ballast design. 6 Information for luminaire design Refer to the relevant lamp data sheet and to Annex E for information for luminaire design. The regional requirements on EMC should be regarded. 7 Data sheets 7.1 Diagrammatic data sheets for location of lamp dimensions 62639-IEC-01 rectangular shaped lamps 62639-IEC-02 circular shaped lamps 62639-IEC-03 A110, A130 and A140 shaped lamps 62639-IEC-04 G95 shaped lamps 62639-I

展开阅读全文
相关资源
猜你喜欢
  • BS 6911-1-1988 Testing earth-moving machinery - Method for determination of volumetric rating of crawler and wheel tractor dozer blades《运土机械试验 第1部分 履带式拖拉机和轮式拖拉机推土刮板的容积额定值的测定方法》.pdf BS 6911-1-1988 Testing earth-moving machinery - Method for determination of volumetric rating of crawler and wheel tractor dozer blades《运土机械试验 第1部分 履带式拖拉机和轮式拖拉机推土刮板的容积额定值的测定方法》.pdf
  • BS 6911-10-1996 Testing earth-moving machinery Machine-mounted retrieval device Performance requirements《运土机械试验 机械安装补偿装置 性能要求》.pdf BS 6911-10-1996 Testing earth-moving machinery Machine-mounted retrieval device Performance requirements《运土机械试验 机械安装补偿装置 性能要求》.pdf
  • BS 6911-12-1998 Testing earth-moving machinery - Determination of turning dimensions of wheeled machines《运土机械试验 轮式机械转弯尺寸的测定》.pdf BS 6911-12-1998 Testing earth-moving machinery - Determination of turning dimensions of wheeled machines《运土机械试验 轮式机械转弯尺寸的测定》.pdf
  • BS 6911-6-1992 Testing earth-moving machinery - Method for the evaluation of lift capacity of pipelayers and wheel tractors or loaders equipped with side boom《运土机械试验 第6部分 侧面带起重吊杆的管.pdf BS 6911-6-1992 Testing earth-moving machinery - Method for the evaluation of lift capacity of pipelayers and wheel tractors or loaders equipped with side boom《运土机械试验 第6部分 侧面带起重吊杆的管.pdf
  • BS 6911-7-1992 Testing earth-moving machinery - Testing of earth-moving machinery - Specification for units of measurement and tolerances《运土机械试验 第7部分 测量单位和公差规范》.pdf BS 6911-7-1992 Testing earth-moving machinery - Testing of earth-moving machinery - Specification for units of measurement and tolerances《运土机械试验 第7部分 测量单位和公差规范》.pdf
  • BS 6911-8-1993 Testing earth-moving machinery - Determination of slope limits for machine fluid systems operation (static test method)《运土机械试验 第8部分 机械液压系统操作倾斜度极限值的测定(静态试验法)》.pdf BS 6911-8-1993 Testing earth-moving machinery - Determination of slope limits for machine fluid systems operation (static test method)《运土机械试验 第8部分 机械液压系统操作倾斜度极限值的测定(静态试验法)》.pdf
  • BS 6911-9-1993 Testing earth-moving machinery Verification of retarder capability of dumpers and tractor-scrapers《土方机械试验 翻斗车和拖拉机刮板的减速器性能验证》.pdf BS 6911-9-1993 Testing earth-moving machinery Verification of retarder capability of dumpers and tractor-scrapers《土方机械试验 翻斗车和拖拉机刮板的减速器性能验证》.pdf
  • BS 6912-11-1993 Safety of earth-moving machinery - Requirements for lift arm support devices《运土机械的安全性 第11部分 升降臂支撑装置的要求》.pdf BS 6912-11-1993 Safety of earth-moving machinery - Requirements for lift arm support devices《运土机械的安全性 第11部分 升降臂支撑装置的要求》.pdf
  • BS 6912-16-1995 Safety of earth-moving machinery - Specification for dumper body support and operators cab tilt support devices《运土机械的安全性 翻斗车身支架和司机室翻转支架装置规范》.pdf BS 6912-16-1995 Safety of earth-moving machinery - Specification for dumper body support and operators cab tilt support devices《运土机械的安全性 翻斗车身支架和司机室翻转支架装置规范》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有