EN IEC 61968-3-2018 en Application integration at electric utilities - System interfaces for distribution management - Part 3 Interface for network operations.pdf

上传人:registerpick115 文档编号:721736 上传时间:2019-01-04 格式:PDF 页数:166 大小:5.72MB
下载 相关 举报
EN IEC 61968-3-2018 en Application integration at electric utilities - System interfaces for distribution management - Part 3 Interface for network operations.pdf_第1页
第1页 / 共166页
EN IEC 61968-3-2018 en Application integration at electric utilities - System interfaces for distribution management - Part 3 Interface for network operations.pdf_第2页
第2页 / 共166页
EN IEC 61968-3-2018 en Application integration at electric utilities - System interfaces for distribution management - Part 3 Interface for network operations.pdf_第3页
第3页 / 共166页
EN IEC 61968-3-2018 en Application integration at electric utilities - System interfaces for distribution management - Part 3 Interface for network operations.pdf_第4页
第4页 / 共166页
EN IEC 61968-3-2018 en Application integration at electric utilities - System interfaces for distribution management - Part 3 Interface for network operations.pdf_第5页
第5页 / 共166页
点击查看更多>>
资源描述

1、BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06Application integration at electric utilities - System interfaces for distribution managementPart 3: Interface for network operationsBS EN IEC 61968-3:2018EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN IEC 61968-3

2、 May 2018 ICS 33.200 Supersedes EN 61968-3:2004 English Version Application integration at electric utilities - System interfaces for distribution management - Part 3: Interface for network operations (IEC 61968-3:2017) Intgration dapplications pour les services lectriques - Interfaces systme pour l

3、a gestion de la distribution - Partie 3: Interface pour lexploitation du rseau (IEC 61968-3:2017) Integration von Anwendungen in Anlagen der Elektrizittsversorgung - Systemschnittstellen fr Netzfhrung - Teil 3: Schnittstelle fr Netzbetriebsarten (IEC 61968-3:2017) This European Standard was approved

4、 by CENELEC on 2017-03-03. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national

5、 standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own l

6、anguage and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, F

7、rance, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Eur

8、open de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels 2018 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN IEC 61968-3:2018 E Nat

9、ional forewordThis British Standard is the UK implementation of EN IEC 61968-3:2018. It is identical to IEC 61968-3:2017. It supersedes BS EN 61968-3:2004, which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee PEL/57, Power systems management and associated

10、information exchange.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2018 Pu

11、blished by BSI Standards Limited 2018ISBN 978 0 580 93037 9ICS 33.200Compliance with a British Standard cannot confer immunity from legal obligations. This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 May 2018.Amendments/corrigenda issued si

12、nce publicationDate Text affectedBRITISH STANDARDBS EN IEC 61968-3:2018EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN IEC 61968-3 May 2018 ICS 33.200 Supersedes EN 61968-3:2004 English Version Application integration at electric utilities - System interfaces for distribution management - Part

13、3: Interface for network operations (IEC 61968-3:2017) Intgration dapplications pour les services lectriques - Interfaces systme pour la gestion de la distribution - Partie 3: Interface pour lexploitation du rseau (IEC 61968-3:2017) Integration von Anwendungen in Anlagen der Elektrizittsversorgung -

14、 Systemschnittstellen fr Netzfhrung - Teil 3: Schnittstelle fr Netzbetriebsarten (IEC 61968-3:2017) This European Standard was approved by CENELEC on 2017-03-03. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Stan

15、dard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (En

16、glish, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees

17、of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia,

18、 Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels 2018 CEN

19、ELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN IEC 61968-3:2018 E BS EN IEC 61968-3:2018EN IEC 61968-3:2018 (E) 2 European foreword The text of document 57/1810/FDIS, future edition 2 of IEC 61968-3, prepared by IEC/TC 57 “Power syste

20、ms management and associated information exchange“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN IEC 61968-3:2018. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard

21、or by endorsement (dop) 2018-11-18 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2021-05-18 This document supersedes EN 61968-3:2004. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent r

22、ights. CENELEC shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Association. Endorsement notice The text of the International Standard IEC 61968-3:2017

23、was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 61968-4 NOTE Harmonized as EN 61968-4. IEC 61968-6 NOTE Harmonized as EN 61968-6. IEC 61968-8 NOTE Harmonized as E

24、N 61968-8. IEC 61968-9 NOTE Harmonized as EN 61968-9. IEC 61968-11 NOTE Harmonized as EN 61968-11. IEC 61968-13 NOTE Harmonized as EN 61968-13. IEC 62361-100 NOTE Harmonized as EN 62361-100. BS EN IEC 61968-3:2018EN IEC 61968-3:2018 (E) 3 Annex ZA (normative) Normative references to international pu

25、blications with their corresponding European publications The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of

26、 the referenced document (including any amendments) applies. NOTE 1 Where an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is ava

27、ilable here: www.cenelec.eu. Publication Year Title EN/HD Year IEC 61968-1 - Application integration at electric utilities - System interfaces for distribution management - Part 1: Interface architecture and general requirements EN 61968-1 - IEC/TS 61968-2 - Application integration at electric utili

28、ties - System interfaces for distribution management - Part 2: Glossary - - IEC 61968-100 - Application integration at electric utilities - System interfaces for distribution management - Part 100: Implementation profiles EN 61968-100 - IEC 61970-301 - Energy Management System Application Program In

29、terface (EMS-API) - Part 301: Common information model (CIM) base EN 61970-301 - BS EN IEC 61968-3:2018 2 IEC 61968-3:2017 IEC 2017 CONTENTS FOREWORD . 6 INTRODUCTION . 8 1 Scope 9 2 Normative references 10 3 Terms, definitions and abbreviated terms 11 3.1 Terms and definitions 11 3.2 Abbreviated te

30、rms . 11 4 Reference and Information Models 11 4.1 General approach to network operations . 11 4.2 Reference Model . 12 4.3 Interface Reference Model 13 4.4 Network operations functions and components . 13 4.5 Static Information Model . 15 4.5.1 General . 15 4.5.2 Classes related to network operatio

31、ns . 15 5 Network operations message payloads 15 5.1 General . 15 5.2 OperationsConfiguration payload 16 5.2.1 General . 16 5.2.2 Message payload . 16 5.3 MeasurementsAndControls payload . 17 5.3.1 General . 17 5.3.2 Measurement . 17 5.3.3 Control 18 5.3.4 Message payload . 18 5.4 TemporaryNetworkCh

32、anges payload 21 5.4.1 General . 21 5.4.2 Message payloads . 22 5.5 SwitchingPlan payload . 27 5.5.1 General . 27 5.5.2 Message payload . 28 5.6 OperationalTags payload . 36 5.6.1 General . 36 5.6.2 Message payload . 37 5.7 TroubleTicket payload 38 5.8 Incident payload 39 5.8.1 General . 39 5.8.2 Me

33、ssage payload . 41 5.9 Outage payload 42 5.9.1 General . 42 5.9.2 Message payload . 44 5.10 Metering message payloads 45 5.10.1 EndDeviceEvent . 45 5.10.2 MeterReading 45 BS EN IEC 61968-3:2018IEC 61968-3:2017 IEC 2017 3 5.11 Work message payloads 46 5.11.1 WorkOrder 46 5.12 SwitchingOrder 47 5.12.1

34、 General . 47 5.12.2 Message payload . 48 5.13 TroubleOrder 49 5.13.1 General . 49 5.13.2 Message payload . 50 5.14 OutageSchedule 51 5.14.1 General . 51 5.14.2 Message payload . 52 6 Document Conventions 55 6.1 UML diagrams. 55 6.2 Message payload definitions . 55 6.2.1 General . 55 6.2.2 Mandatory

35、 versus Optional 55 6.3 Synchronous versus Asynchronous Messages 55 6.4 Message exchanges . 55 Annex A (informative) Use Cases 56 A.1 General . 56 A.2 FLISR . 56 A.2.1 Overview . 56 A.2.2 FLISR for SCADA-detected outage, SCADA switching . 56 A.2.3 FLISR for trouble call and AMI outage, crew switchin

36、g . 58 A.3 Planned outage . 62 A.3.1 Planned outage for maintenance Manual process . 62 A.3.2 Planned outage for maintenance Crew switching 63 Annex B (normative) XML Schemas for message payloads 68 B.1 General . 68 B.2 Incidents message payload . 68 B.3 MeasurementsAndControls message payload. 75 B

37、.4 OperationalTags message payload 82 B.5 OperationsConfig message payload 85 B.6 OutagesAndFaults message payload . 87 B.7 OutageSchedules message payload 96 B.8 SwitchingOrders message payload 117 B.9 SwitchingPlans message payload 123 B.10 TemporaryNetworkChanges message payload . 140 B.11 Troubl

38、eOrders message payload 150 Bibliography 160 Figure 1 IEC 61968-3 Scope 10 Figure 2 IEC 61968-3 Reference Model . 12 Figure 3 OperationsConfiguration message payload 16 Figure 4 MeasurementsAndControls 17 BS EN IEC 61968-3:2018 4 IEC 61968-3:2017 IEC 2017 Figure 5 MeasurementsAndControls message pay

39、load 19 Figure 6 MeasurementsAndControls message payload, AnalogValue detail . 20 Figure 7 MeasurementsAndControls message payload, Setpoint (AnalogControl) detail 21 Figure 8 Temporary Network Changes . 22 Figure 9 TemporaryNetworkChanges message payload 22 Figure 10 TemporaryNetworkChanges message

40、 payload, Clamp detail . 23 Figure 11 TemporaryNetworkChanges message payload, Cut detail 24 Figure 12 TemporaryNetworkChanges message payload, EnergySource Details 25 Figure 13 TemporaryNetworkChanges message payload, Ground details . 26 Figure 14 TemporaryNetworkChanges message payload, Jumper Det

41、ails. 27 Figure 15 Switching Plan . 28 Figure 16 SwitchingPlans message payload . 29 Figure 17 SwitchingPlans message payload, SafetyDocument detail . 30 Figure 18 SwitchingPlan message payload, ClearanceAction detail . 31 Figure 19 SwitchingPlan message payload, GenericAction detail . 32 Figure 20

42、SwitchingPlan message payload, EnergySourceAction detail 32 Figure 21 SwitchingPlan message payload, CutAction detail . 33 Figure 22 SwitchingPlan message payload, GroundAction detail 34 Figure 23 SwitchingPlan message payload, JumperAction detail 34 Figure 24 SwitchingPlan message payload, Switchin

43、gAction detail . 35 Figure 25 SwitchingPlan message payload, TagAction detail . 36 Figure 26 Tags . 37 Figure 27 OperationalTags message payload . 38 Figure 28 Trouble Ticket 39 Figure 29 Incident . 40 Figure 30 Incident message payload . 41 Figure 31 Outage . 42 Figure 32 OutagesAndFaults message p

44、ayload 44 Figure 33 End Device Event . 45 Figure 34 Meter Reading 46 Figure 35 Work Order 47 Figure 36 Switching Order . 48 Figure 37 SwitchingOrder message payload . 49 Figure 38 Trouble Order . 50 Figure 39 TroubleOrder message payload . 51 Figure 40 Outage Schedule . 52 Figure 41 OutageSchedule m

45、essage payload . 53 BS EN IEC 61968-3:2018IEC 61968-3:2017 IEC 2017 5 Figure 42 OutageSchedule message payload, PlannedOutages detail . 54 Figure A.1 FLISR for SCADA-Detected Outage, SCADA Switching 57 Figure A.2 FLISR for trouble call and AMI outage, crew switching 60 Figure A.3 Planned outage for

46、maintenance Manual process 63 Figure A.4 Planned outage for maintenance, crew switching 65 Table 1 Business Functions and Abstract Components 14 Table 2 Interpretation of Network Operations Business Functions 15 Table 3 Classes related to network operations . 15 Table A.1 Message Flow for FLISR SCAD

47、A-Detected Outage, SCADA Switching 58 Table A.2 Message flows for FLISR for trouble call and AMI outage, crew switching 61 Table A.3 Message flows for planned outage for maintenance, crew switching 66 BS EN IEC 61968-3:2018 6 IEC 61968-3:2017 IEC 2017 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ APPL

48、ICATION INTEGRATION AT ELECTRIC UTILITIES SYSTEM INTERFACES FOR DISTRIBUTION MANAGEMENT Part 3: Interface for network operations FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC Na

49、tional Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publi