1、BSI Standards PublicationBS EN ISO 4064-5:2014Water meters for cold potablewater and hot waterPart 5: Installation requirementsBS EN ISO 4064-5:2014Incorporating corrigendum November 2014BS EN ISO 4064-5:2014 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN ISO 4
2、064-5:2014. It supersedes BS EN 14154-2:2005+A2:2011, which is withdrawn.The UK participation in its preparation was entrusted by Technical Committee CPI/30, Measurement of fluid flow in closed conduits, to Subcommittee CPI/30/7, Volume flow-rate methods.A list of organizations represented on this s
3、ubcommittee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2014. Published by BSI Standards Limited 2014ISBN 978 0 580 88482 5ICS
4、 91.140.60Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 June 2014.Amendments/corrigenda issued since publicationDate Text affected30 November 2014 Implement
5、ation of CEN Correction Notice 20 August 2014: Superseding information updated in national and CEN forewordsEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN ISO 4064-5 June 2014 ICS 91.140.60 Supersedes EN 14154-2:2005+A2:2011English Version Water meters for cold potable water and hot water - Pa
6、rt 5: Installation requirements (ISO 4064-5:2014) Compteurs deau potable froide et deau chaude - Partie 5: Exigences dinstallation (ISO 4064-5:2014) Wasserzhler zum Messen von kaltem Trinkwasser und heiem Wasser - Teil 5: Einbaubedingungen (ISO 4064-5:2014) This European Standard was approved by CEN
7、 on 21 September 2013. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standar
8、ds may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and noti
9、fied to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Ic
10、eland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Man
11、agement Centre: Avenue Marnix 17, B-1000 Brussels 2014 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN ISO 4064-5:2014 EBS EN ISO 4064-5:2014EN ISO 4064-5:2014 (E) 3 Foreword This document (EN ISO 4064-5:2014) has been prepared by
12、Technical Committee ISO/TC 30 “Measurement of fluid flow in closed conduits” in collaboration with Technical Committee CEN/TC 92 “Water meters” the secretariat of which is held by SNV. This European Standard shall be given the status of a national standard, either by publication of an identical text
13、 or by endorsement, at the latest by December 2014, and conflicting national standards shall be withdrawn at the latest by December 2014. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held respons
14、ible for identifying any or all such patent rights. This document supersedes EN 14154-3:2005+A2:2011, EN 14154-2:2005+A2:2011, EN 14154-1:2005+A2:2011. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this Europ
15、ean Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slov
16、enia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. Endorsement notice The text of ISO 4064-5:2014 has been approved by CEN as EN ISO 4064-5:2014 without any modification. BS EN ISO 4064-5:2014EN ISO 4064-5:2014 (E) 3 Foreword This document (EN ISO 4064-5:2014) has been prepared by Tech
17、nical Committee ISO/TC 30 “Measurement of fluid flow in closed conduits” in collaboration with Technical Committee CEN/TC 92 “Water meters” the secretariat of which is held by SNV. This European Standard shall be given the status of a national standard, either by publication of an identical text or
18、by endorsement, at the latest by December 2014, and conflicting national standards shall be withdrawn at the latest by December 2014. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible
19、 for identifying any or all such patent rights. This document supersedes EN 14154-3:2005+A2:2011, EN 14154-2:2005+A2:2011, EN 14154-1:2005+A2:2011. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European
20、Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia
21、, Spain, Sweden, Switzerland, Turkey and the United Kingdom. Endorsement notice The text of ISO 4064-5:2014 has been approved by CEN as EN ISO 4064-5:2014 without any modification. EN ISO 4064-5:2014 (E) 3 Foreword This document (EN ISO 4064-5:2014) has been prepared by Technical Committee ISO/TC 30
22、 “Measurement of fluid flow in closed conduits” in collaboration with Technical Committee CEN/TC 92 “Water meters” the secretariat of which is held by SNV. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the la
23、test by December 2014, and conflicting national standards shall be withdra n at the latest by June 2017. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all s
24、uch patent rights. This document supersedes EN 14154-2:2005+A2:2011. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the followi
25、ng countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Nor
26、way, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. Endorsement notice The text of ISO 4064-5:2014 has been approved by CEN as EN ISO 4064-5:2014 without any modification. ii BS EN ISO 4064-5:2014ISO 4064-5:2014(E) ISO 2014 All rights reserv
27、ed iiiContents PageForeword iv1 Scope . 12 Normative references 13 Terms and definitions . 14 Criteria for the selection of water meters 24.1 General considerations 24.2 Information to be provided by the manufacturer . 24.3 Meters operating in parallel or in a group 25 Associated fittings . 35.1 Gen
28、eral . 35.2 Upstream of the meter . 35.3 Downstream of the meter 36 Installation . 46.1 General requirements . 46.2 Installation requirements 46.3 Water quality (suspended particles) . 56.4 Electromagnetic meters 56.5 Meters operating in parallel or in a group 56.6 Security of operation . 57 Hydraul
29、ic disturbances . 57.1 General considerations 57.2 Methods to eliminate disturbances . 68 First operation of new or repaired water meters 78.1 General considerations 78.2 Meters operating in parallel or in a group 78.3 Protection of the meter 78.4 Safety of personnel and users 98.5 Comfort of person
30、nel Access to the water meter and fittings .10Bibliography .12BS EN ISO 4064-5:2014ISO 4064-5:2014(E)ForewordISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally
31、carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the wo
32、rk. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.The procedures used to develop this document and those intended for its further maintenance are described in the ISO/IEC Directives, Part 1. In particular the diff
33、erent approval criteria needed for the different types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2, www.iso.org/directives.Attention is drawn to the possibility that some of the elements of this document may be
34、the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the document will be in the Introduction and/or on the ISO list of patent declarations received, www.iso.org/patents.Any tr
35、ade name used in this document is information given for the convenience of users and does not constitute an endorsement.The committee responsible for this document is ISO/TC 30, Measurement of fluid flow in closed conduits, Subcommittee SC 7, Volume methods including water meters. It supersedes ISO
36、4064-2:2005, which has been technically revised.ISO 4064 consists of the following parts, under the general title Water meters for cold potable water and hot water: Part 1: Metrological and technical requirements Part 2: Test methods Part 3: Test report format Part 4: Non-metrological requirements n
37、ot covered in ISO 4064-1 Part 5: Installation requirementsiv ISO 2014 All rights reservedBS EN ISO 4064-5:2014INTERNATIONAL STANDARD ISO 4064-5:2014(E)Water meters for cold potable water and hot water Part 5: Installation requirements1 ScopeThis part of ISO 4064 applies to water meters used to meter
38、 the volume of cold potable water and hot water flowing through a fully charged, closed conduit. These water meters incorporate devices which indicate the integrated volume.This part of ISO 4064 specifies criteria for the selection of single, combination and concentric water meters, associated fitti
39、ngs, installation, special requirements for meters, and the first operation of new or repaired meters to ensure accurate constant measurement and reliable reading of the meter.In addition to meters based on mechanical principles, this part of ISO 4064 also applies to water meters based on electrical
40、 or electronic principles, and to water meters based on mechanical principles incorporating electronic devices, used to measure the volume of cold potable water and hot water. It also applies to electronic ancillary devices. Ancillary devices are optional. However, national or international regulati
41、ons may make some ancillary devices mandatory in relation to the utilization of the water meter.The recommendations of this part of ISO 4064 apply to water meters, irrespective of technology, defined as integrating measuring instruments continuously determining the volume of water flowing through th
42、em.NOTE Any national regulations apply in the country of use.2 Normative referencesThe following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the la
43、test edition of the referenced document (including any amendments) applies.ISO 4064-1:2014|OIML R 49-1:2013, Water meters for cold potable water and hot water Part 1: Metrological and technical requirementsISO 6817, Measurement of conductive liquid flow in closed conduits Method using electromagneti
44、c flowmeters3 Terms and definitionsFor the purposes of this part of ISO 4064, the definitions given in ISO 4064-1|OIML R 49-1 and the following apply.3.1parallel operationoperation of two or more meters grouped together and connected to a common source and a common delivery3.2multiple meter operatio
45、noperation of several meters grouped together where their inlets are connected to a common source, or their outlets to a common delivery, but not both at the same time ISO 2014 All rights reserved 1BS EN ISO 4064-5:2014ISO 4064-5:2014(E)3.3adaptoradditional mechanical device fitted into a connection
46、 interface on location in order to combine an unmodified cartridge meter of one geometry with a connection interface of another geometry3.4converterconnection interface consisting of several parts produced as a complete unit prior to installation into the supply systemNote 1 to entry: No assembly wo
47、rk is to be done on location other than the installation of the complete interface. Conversion is related to either change of flow pattern, change of flow direction or extension of seat depth.4 Criteria for the selection of water meters4.1 General considerationsThe type, metrological characteristics
48、, and sizes of water meters should be determined according to the operating conditions of the installation and the environmental class(es) demanded, taking into account, particularly, the following: the available supply pressure; the physical and chemical characteristics of the water, including wate
49、r temperature and water quality (suspended particles); the acceptable pressure loss across the meter; the expected flow rates: the flow rates Q1and Q3of the meter (as defined in ISO 4064-1:2014|OIML R 49-1:2013, Clause 3) shall be compatible with the expected flow rate conditions of the installations, including the water flow direction(s); the suitability of the meter type for the intended mechanical, climatic, electrical, and hydraulic conditions, including ambient rel