EN ISO 8362-3-2003 en Injection containers and accessories Part 3 Aluminium caps for injection vials《注射剂用注射器容器及附件 第3部分 注射瓶铝盖 ISO 8362-3-2001 代替EN 28362-3-1993》.pdf

上传人:twoload295 文档编号:723425 上传时间:2019-01-04 格式:PDF 页数:16 大小:294.52KB
下载 相关 举报
EN ISO 8362-3-2003 en Injection containers and accessories Part 3 Aluminium caps for injection vials《注射剂用注射器容器及附件 第3部分 注射瓶铝盖 ISO 8362-3-2001 代替EN 28362-3-1993》.pdf_第1页
第1页 / 共16页
EN ISO 8362-3-2003 en Injection containers and accessories Part 3 Aluminium caps for injection vials《注射剂用注射器容器及附件 第3部分 注射瓶铝盖 ISO 8362-3-2001 代替EN 28362-3-1993》.pdf_第2页
第2页 / 共16页
EN ISO 8362-3-2003 en Injection containers and accessories Part 3 Aluminium caps for injection vials《注射剂用注射器容器及附件 第3部分 注射瓶铝盖 ISO 8362-3-2001 代替EN 28362-3-1993》.pdf_第3页
第3页 / 共16页
EN ISO 8362-3-2003 en Injection containers and accessories Part 3 Aluminium caps for injection vials《注射剂用注射器容器及附件 第3部分 注射瓶铝盖 ISO 8362-3-2001 代替EN 28362-3-1993》.pdf_第4页
第4页 / 共16页
EN ISO 8362-3-2003 en Injection containers and accessories Part 3 Aluminium caps for injection vials《注射剂用注射器容器及附件 第3部分 注射瓶铝盖 ISO 8362-3-2001 代替EN 28362-3-1993》.pdf_第5页
第5页 / 共16页
点击查看更多>>
资源描述

1、BRITISH STANDARD BS EN ISO 8362-3:2003 Incorporating Corrigendum No. 1 Injection containers and accessories Part 3: Aluminium caps for injection vials The European Standard EN ISO 8362-3:2003 has the status of a British Standard ICS 11.040.20 BS EN ISO 8362-3:2003 This British Standard was published

2、 under the authority of the Standards Policy and Strategy Committee on 28 February 2003 BSI 1 May 2003 ISBN 0 580 41323 3 National foreword This British Standard is the official English language version of EN ISO 8362-3:2003. It is identical with ISO 8362-3:2001. It supersedes BS EN 28362-3:1993 whi

3、ch is withdrawn. The UK participation in its preparation was entrusted to Technical Committee CH/212, IVDs, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement inter

4、national or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purp

5、ort to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committe

6、e any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN ISO title page, the EN ISO

7、foreword page, the ISO title page, pages ii to v, a blank page, pages 1 to 3, the Annex ZA page, an inside back cover and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date Comments 14471 Corr

8、igendum No. 1 1 May 2003 Replacing the EN ISO foreword page and the Annex ZA pageEUROPEANSTANDARD NORMEEUROPENNE EUROPISCHENORM ENISO83623 February2003 ICS11.040.20 SupersedesEN283623:1993 Englishversion InjectioncontainersandaccessoriesPart3:Aluminiumcaps forinjectionvials(ISO83623:2001) Rcipientse

9、taccessoirespourproduitsinjectablesPartie 3:Capsulesenaluminiumpourflacons(ISO83623:2001) InjektionsbehltnissefrInjektionsprparateundZubehr Teil3:AluminiumBrdelkappenfrInjektionsflaschen(ISO 83623:2001) ThisEuropeanStandardwasapprovedbyCENon27December2002. CENmembersareboundtocomplywiththeCEN/CENELE

10、CInternalRegulationswhichstipulatetheconditionsforgivingthisEurope an Standardthestatusofanationalstandardwithoutanyalteration.Uptodatelistsandbibliographicalreferencesconcernings uchnational standardsmaybeobtainedonapplicationtotheManagementCentreortoanyCENmember. ThisEuropeanStandardexistsinthreeo

11、fficialversions(English,French,German).Aversioninanyotherlanguagemadebytra nslation undertheresponsibilityofaCENmemberintoitsownlanguageandnotifiedtotheManagementCentrehasthesamestatusasthe official versions. CENmembersarethenationalstandardsbodiesofAustria,Belgium,CzechRepublic,Denmark,Finland,Fran

12、ce,Germany,Greece, Hungary,Iceland,Ireland,Italy,Luxembourg,Malta,Netherlands,Norway,Portugal,SlovakRepublic,Spain,Sweden,Switzerland and UnitedKingdom. EUROPEANCOMMITTEEFORSTANDARDIZATION COMITEUROPENDENORMALISATION EUROPISCHESKOMITEEFRNORMUNG ManagementCentre:ruedeStassart,36B1050Brussels 2003CEN

13、Allrightsofexploitationinanyformandbyanymeansreserved worldwideforCENnationalMembers. Ref.No.ENISO83623:2003ECORRECTED20030326 Foreword ThetextofISO83623:2001hasbeenpreparedbyTechnicalCommitteeISO/TC76 “Transfusion,infusionandinjectionequipmentformedicalandpharmaceuticaluse“ofthe InternationalOrgani

14、zationforStandardization(ISO)andhasbeentakenoverasENISO8362 3:2003byCMC. ThisEuropeanStandardshallbegiventhestatusofanationalstandard,eitherbypublicationof anidenticaltextorbyendorsement,atthelatestbyAugust2003,andconflictingnational standardsshallbewithdrawnatthelatestbyAugust2003. Thisdocumentsupe

15、rsedesEN283623:1993. AccordingtotheCEN/CENELECInternalRegulations,thenationalstandardsorganizationsof thefollowingcountriesareboundtoimplementthisEuropeanStandard:Austria,Belgium,Czech Republic,Denmark,Finland,France,Germany,Greece,Hungary,Iceland,Ireland,Italy, Luxembourg,Malta,Netherlands,Norway,P

16、ortugal,Slovakia,Spain,Sweden,Switzerlandand theUnitedKingdom. Endorsementnotice ThetextofISO83623:2001hasbeenapprovedbyCENasENISO83623:2003withoutany modifications. NOTENormativereferencestoInternationalStandardsarelistedinAnnexZA(normative). ENISO83623:2003INTERNATIONAL STANDARD ISO 8362-3 Second

17、edition 2001-12-01 Reference number ISO 8362-3:2001(E) Injection containers and accessories Part 3: Aluminium caps for injection vials Rcipients et accessoires pour produits injectables Partie 3: Capsules en aluminium pour flacons ENISO83623:2003ENISO83623:2003iiOSI -26381002:3)E( ISO 1002 All rithg

18、s rreseved iii Contents Page 1 Scope . 1 2 Normative reference . 1 3 Dimensions and designation 1 4 Requirements . 1 5 Packaging . 3 6 Marking . 3 ENISO83623:2003iiiISO -26382:3)E(100 vi ISO 1002 All rithgs rreseved Foreword ISO (the International Organization for Standardization) is a worldwide fed

19、eration of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that comm

20、ittee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accorda

21、nce with the rules given in the ISO/IEC Directives, Part 3. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is

22、drawn to the possibility that some of the elements of this part of ISO 8362 may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. International Standard ISO 8362-3 was prepared by Technical Committee ISO/TC 76, Transfusion, infusion and

23、 injection equipment for medical and pharmaceutical use. This second edition cancels and replaces the first edition (ISO 8362-3:1989), which has been technically revised. ISO 8362 consists of the following parts, under the general title Injection containers and accessories: Part 1: Injection vials m

24、ade of glass tubing Part 2: Closures for injection vials Part 3: Aluminium caps for injection vials Part 4: Injection vials made of moulded glass Part 5: Freeze drying closures for injection vials Part 6: Caps made of aluminium-plastics combinations for injection vials Part 7: Injection caps made of

25、 aluminium-plastics combinations without overlapping plastics part ENISO83623:2003ivOSI -26381002:3)E( ISO 1002 All rithgs rreseved v Introduction The materials from which injection containers (including the elastomeric closures) are made are suitable primary packaging materials for storing injectab

26、le products until they are administered. However, in this part of ISO 8362, aluminium caps are not considered as primary packaging materials in direct contact with pharmaceutical preparations. ENISO83623:2003vANRETNIITOLAN TSDNADRA OSI -26381002:3)E( ISO 1002 All rithgs rreseved 1 Injection containe

27、rs and accessories Part 3: Aluminium caps for injection vials 1 Scope This part of ISO 8362 specifies aluminium caps for injection vials as described in ISO 8362-1 and ISO 8362-4. 2 Normative reference The following normative document contains provisions which, through reference in this text, consti

28、tute provisions of this part of ISO 8362. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. However, parties to agreements based on this part of ISO 8362 are encouraged to investigate the possibility of applying the most recent edition of the no

29、rmative document indicated below. For undated references, the latest edition of the normative document referred to applies. Members of ISO and IEC maintain registers of currently valid International Standards. ISO 8872, Aluminium caps for transfusion, infusion and injection bottles General requireme

30、nts and test methods 3 Dimensions and designation 3.1 Dimensions The dimensions of aluminium caps shall be as shown in Figure 1 and as given in Table 1. 3.2 Designation Aluminium caps are designated according to type: the four types A, B, C and D are illustrated in Figure 1. The designation is expre

31、ssed as the number and part of this International Standard, followed by the nominal size of the container, followed by the type letter. EXAMPLE A type B (i.e. two-bridge tab) aluminium cap (B) of nominal size 13 complying with the requirements laid down in this part of ISO 8362 is designated. Alumin

32、ium cap ISO 8362-3-13-B 4 Requirements 4.1 General The caps shall meet the requirements of ISO 8872. ENISO83623:20031ISO -26382:3)E(100 2 ISO 1002 All rithgs rreseved Dimensions in millimetres a) Type A Aluminium cap with centre hole b) Type B Aluminium cap with two-bridge tab Key 1 Tear-off perfora

33、tion c) Type C Aluminium cap with three-bridge tab d) Type D Aluminium cap with complete tear-off tab NOTE The width and the number of bridges for types B, C and D depend on the degree of resistance intended. Figure 1 Dimensions and configuration of aluminium caps ENISO83623:20032OSI -26381002:3)E(

34、ISO 1002 All rithgs rreseved 3 4.2 Force required to remove tab 4.2.1 Two- or three-bridge tabs (types B and C) The force needed to remove the tab shall be determined in accordance with ISO 8872 and shall be within the range given in Table 2. 4.2.2 Complete tear-off tab (type D) The force needed to

35、remove the tab completely shall be determined in accordance with ISO 8872 and shall be within the range given in Table 3. 5 Packaging The packaging of aluminium caps shall comply with the requirements of ISO 8872. 6M a r k i n g The aluminium caps shall be marked in accordance with ISO 8872 and with

36、 the designation as specified in 3.2. Table 1 Dimensions of aluminium caps Dimensions in millimetres Nominal size b a b Type A, B and C D 13 13,35 3 to 8 8 to 9 , 6,3 1,0 20 20,35 6 to 11 10 to 13 7,3 to 7,8 a The thickness shall be agreed between manufacturer and user within the given range. The th

37、ickness shall not differ from the nominal value by more than . The extreme limits are given without tolerance. b The diameter and the height shall be agreed between manufacturer and user. The dimensions shall not differ from the nominal value by more than . The extreme limits are given without toler

38、ance. Table 2 Minimum and maximum forces to remove tabs with two (type B) or three (type C) bridges F or c ei nn e w t ons Nominal size Force Type B tabs Type C tabs 13 and 20 25 60 46 76 Table 3 Minimum and maximum forces to remove cap of complete tear-off tab (type D) F or c ei nn e w t ons Nomina

39、l size Force to break bridges Force to tear off tab completely 13 and 20 30 a 50 5 25 a In the case of multiple bridges, the resistance against pressure shall be sufficient, but the individual breaking force will be reduced accordingly. d 1 +0,1 0,05 d 2 0,2 e h 0,2 r 0,2 0,242 max. 0,168 min. 0,022

40、 mm d 2 h 0,2 mm min. max. min. max. min. max. min. max. ENISO83623:20033AnnexZA (normative) Normativereferencestointernationalpublications withtheirrelevantEuropeanpublications ThisEuropeanStandardincorporatesbydatedorundatedreference,provisionsfromother publications.Thesenormativereferencesarecite

41、dattheappropriateplacesinthetextandthe publicationsarelistedhereafter.Fordatedreferences,subsequentamendmentstoorrevisionsof anyofthesepublicationsapplytothisEuropeanStandardonlywhenincorporatedinitby amendmentorrevision.Forundatedreferencesthelatesteditionofthepublicationreferredto applies(includin

42、gamendments). NOTEWhereanInternationalPublicationhasbeenmodifiedbycommonmodifications,indicated by(mod.),therelevantEN/HDapplies. Publication Year Title EN Year ISO8872 1988 Aluminium caps for transfusion, infusion andinjectionbottlesGeneral requirementsandtestmethods EN28872 1993 ENISO83623:2003BS

43、EN ISO 8362-3:2003 BSI 389 Chiswick High Road London W4 4AL BSI British Standards Institution BSI is the independent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter. Revision

44、s British Standards are updated by amendment or revision. Users of British Standards should make sure that they possess the latest amendments or editions. It is the constant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an inaccuracy or ambigu

45、ity while using this British Standard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover. Tel: +44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400. BSI offers members an individual updating service called PLUS which ensures that

46、subscribers automatically receive the latest editions of standards. Buying standards Orders for all BSI, international and foreign standards publications should be addressed to Customer Services. Tel: +44 (0)20 8996 9001. Fax: +44 (0)20 8996 7001. Email: ordersbsi-. Standards are also available from

47、 the BSI website at http:/www.bsi-. In response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as British Standards, unless otherwise requested. Information on standards BSI provides a wide range of information on national, European and international standards through its Library and its Technical Help to Exporters Service. Various BSI electronic information services are also available which give detail

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1