EN ISO 10563-2017 en Buildings and civil engineering works - Sealants - Determination of change in mass and volume.pdf

上传人:medalangle361 文档编号:724121 上传时间:2019-01-09 格式:PDF 页数:12 大小:1.76MB
下载 相关 举报
EN ISO 10563-2017 en Buildings and civil engineering works - Sealants - Determination of change in mass and volume.pdf_第1页
第1页 / 共12页
EN ISO 10563-2017 en Buildings and civil engineering works - Sealants - Determination of change in mass and volume.pdf_第2页
第2页 / 共12页
EN ISO 10563-2017 en Buildings and civil engineering works - Sealants - Determination of change in mass and volume.pdf_第3页
第3页 / 共12页
EN ISO 10563-2017 en Buildings and civil engineering works - Sealants - Determination of change in mass and volume.pdf_第4页
第4页 / 共12页
EN ISO 10563-2017 en Buildings and civil engineering works - Sealants - Determination of change in mass and volume.pdf_第5页
第5页 / 共12页
点击查看更多>>
资源描述

1、Buildings and civil engineering works - Sealants - Determination of change in mass and volume (ISO 10563:2017)BS EN ISO 10563:2017BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN ISO 10563 June 2017 ICS 91.100.50 Su

2、persedes EN ISO 10563:2005English Version Buildings and civil engineering works - Sealants - Determination of change in mass and volume (ISO 10563:2017) Btiments et ouvrages de gnie civil - Mastics - Dtermination des variations de masse et de volume (ISO 10563:2017) Hochbau - Fugendichtstoffe - Best

3、immung der nderung von Masse und Volumen (ISO 10563:2017)This European Standard was approved by CEN on 22 April 2017. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without a

4、ny alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other langu

5、age made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark

6、, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMM

7、ITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN ISO 10563:2017 ENational

8、forewordThis British Standard is the UK implementation of EN ISO 10563:2017. It is identical to ISO 10563:2017. It supersedes BS EN ISO 10563:2005, which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee B/547, Sealants for building and construction.A list of

9、organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2017 Published by BSI Standards Limite

10、d 2017ISBN 978 0 580 90985 6ICS 91.100.50Compliance with a British Standard cannot confer immunity from legal obligations. This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 September 2017.Amendments/corrigenda issued since publicationDate Te

11、xt affectedBRITISH STANDARDBS EN ISO 10563:2017EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN ISO 10563 June 2017 ICS 91.100.50 Supersedes EN ISO 10563:2005English Version Buildings and civil engineering works - Sealants - Determination of change in mass and volume (ISO 10563:2017) Btiments et

12、 ouvrages de gnie civil - Mastics - Dtermination des variations de masse et de volume (ISO 10563:2017) Hochbau - Fugendichtstoffe - Bestimmung der nderung von Masse und Volumen (ISO 10563:2017)This European Standard was approved by CEN on 22 April 2017. CEN members are bound to comply with the CEN/C

13、ENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centr

14、e or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the

15、official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherla

16、nds, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CEN Al

17、l rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN ISO 10563:2017 EBS EN ISO 10563:2017EN ISO 10563:2017 (E) 3 European foreword This document (EN ISO 10563:2017) has been prepared by Technical Committee ISO/TC 59 “Buildings and civil engin

18、eering works“. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by December 2017 and conflicting national standards shall be withdrawn at the latest by December 2017. Attention is drawn to the possibi

19、lity that some of the elements of this document may be the subject of patent rights. CEN shall not be held responsible for identifying any or all such patent rights. This document supersedes EN ISO 10563:2005. According to the CEN-CENELEC Internal Regulations, the national standards organizations of

20、 the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Neth

21、erlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. Endorsement notice The text of ISO 10563:2017 has been approved by CEN as EN ISO 10563:2017 without any modification. BS EN ISO 10563:2017ISO 10563:2017(E)Foreword iv1 S

22、cope . 12 Normative references 13 Terms and definitions . 14 Principle 15 Apparatus and materials 16 Preparation of test specimens 26.1 For non-sagging sealant 26.2 For self-levelling sealant . 27 Test procedure 37.1 General . 37.2 Preconditioning 37.3 Specific conditioning 38 Calculation and expres

23、sion of results . 38.1 Change in mass . 38.2 Change in volume 49 Test report . 4 ISO 2017 All rights reserved iiiContents PageBS EN ISO 10563:2017ISO 10563:2017(E)ForewordISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodie

24、s). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and n

25、on-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.The procedures used to develop this document and those intended for its further maintenance are descr

26、ibed in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the different types of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/ directives).Attention is drawn

27、 to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any patent rights identified during the development of the document will be in the Introduction and/or on th

28、e ISO list of patent declarations received (see www .iso .org/ patents).Any trade name used in this document is information given for the convenience of users and does not constitute an endorsement.For an explanation on the meaning of ISO specific terms and expressions related to conformity assessme

29、nt, as well as information about ISOs adherence to the World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see the following URL: www .iso .org/ iso/ foreword .html.This document was prepared by Technical Committee ISO/TC 59, Buildings and civil engineering works, Subc

30、ommittee SC 8, Sealants.This third edition cancels and replaces the second edition (ISO 10563:2005), which has been technically revised.The main changes compared to the previous edition are as follows: To include the determination of loss of volume for self- levelling sealants; To precise the target

31、 of the test: not intended to determine the absolute maximum value of loss of volume of a tested sealant, but it is an indicative measurement of the loss of volume under specified parameters; To precise the conditioning time: (28 days +/- 3 hours) at (23 +/- 2) C To precise the apparatus; To precise

32、 the localization of the filled rings in the oven.iv ISO 2017 All rights reservedBS EN ISO 10563:2017INTERNATIONAL STANDARD ISO 10563:2017(E)Buildings and civil engineering works Sealants Determination of change in mass and volume1 ScopeThis document specifies a method for the determination of the c

33、hange of mass and the change of volume of self-levelling and non-sagging sealants used in joints in building construction.NOTE This test procedure is not intended to determine the absolute maximum value of loss of volume of a tested sealant, but it is an indicative measurement of the loss of volume

34、under specified parameters.2 Normative referencesThe following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the refe

35、renced document (including any amendments) applies.ISO 6927, Buildings and civil engineering works Sealants Vocabulary3 Terms and definitionsFor the purposes of this document, the terms and definitions given in ISO 6927 apply.ISO and IEC maintain terminological databases for use in standardization a

36、t the following addresses: IEC Electropedia: available at h t t p :/ www .electropedia .org/ ISO Online browsing platform: available at h t t p :/ www .iso .org/ obp4 PrincipleTest specimens consist of either metal rings filled with non-sagging sealant or metal moulds filled with self-levelling seal

37、ant. The rings or moulds are weighed in air and in water, before and after filling, before and after specific conditioning. The change in mass and in volume of the tested sealant is calculated.5 Apparatus and materials5.1 Rings of non-corrosive metal for non-sagging sealant, having the following dim

38、ensions: inner diameter, (30 1) mm; height, (10 0,1) mm. A hook or loop is fixed to each ring to suspend it from a string for the weighing procedure.5.2 Anti-adherent substrate for non-sagging sealant, for the preparation of test specimens.EXAMPLE Wet paper.5.3 Moulds of non-corrosive metal for self

39、-levelling sealant, having the following dimensions: inner diameter, (30 1) mm; inner depth, (10 0,1) mm.5.4 Balance, with an accuracy of 0,01 g, capable of being used to weigh the test specimens in air and immersed in test liquid. ISO 2017 All rights reserved 1BS EN ISO 10563:2017ISO 10563:2017(E)5

40、.5 Test liquid, at a temperature of (23 2) C, consisting of water with the addition of up to 0,25 % (by mass) of a low-foam surfactant. In the case of water-sensitive sealants, laboratory grade 2,2,4-trimethylpentane (iso-octane) shall be used.5.6 Preconditioning chamber, capable of being controlled

41、 at (23 2) C and (50 10) % relative humidity.5.7 Ventilated oven, with a volume of (200 100) L, capable of being controlled at (70 2) C.5.8 Container, for the immersion of the test specimens in the test liquid.6 Preparation of test specimens6.1 For non-sagging sealantThe sealant and the metal rings

42、(5.1) shall be brought to (23 2) C. Three test specimens shall be prepared for each property to be tested.Each metal ring shall be weighed in air (mass m1) using the balance (5.4), and, for the volume test, also in the test liquid (5.5) (mass m2).The rings shall be set on the anti-adherent substrate

43、 (5.2) and filled with the sealant to be tested using the following procedure.a) The formation of air bubbles shall be avoided.b) The sealant shall be pressed on the inner surfaces of the metal rings to ensure intimate contact.c) The sealant surface shall be tooled so that it is flush with the upper

44、 rim of the metal rings.d) The test specimens shall be removed immediately from the anti-adherent substrate such that the reverse side of the sealant is flush.e) The filled rings shall be weighed immediately in air (mass m3), and, for the volume change, also in the test liquid (mass m4). For water-b

45、orne sealants, these measurements shall be carried out after 60 min and shall be completed within 30 s.6.2 For self-levelling sealantThe sealant and the metal moulds (5.3) shall be brought to (23 2) C. Three test specimens shall be prepared for each property to be tested.Each metal mould shall be we

46、ighed in air (mass m1) using the balance (5.4), and, for the volume test, also in the test liquid (5.5) (mass m2).The moulds shall be filled with the sealant to be tested using the following procedure.a) The formation of air bubbles shall be avoided.b) The sealant shall be pressed on the inner surfa

47、ces of the metal moulds to ensure intimate contact.c) The sealant surface shall be tooled so that it is flush with the upper rim of the metal moulds.d) The filled moulds shall be weighed immediately in air (mass m3), and, for the volume change, also in the test liquid (mass m4). For water-borne seal

48、ants, these measurements shall be carried out after 60 min and shall be completed within 30 s.2 ISO 2017 All rights reservedBS EN ISO 10563:2017ISO 10563:2017(E)7 Test procedure7.1 GeneralDuring the test procedure, the test specimens shall be positioned: either vertically for non-sagging sealant, or

49、 horizontally for self-levelling sealant.7.2 PreconditioningThe test specimens shall be conditioned in the chamber (5.6) at (23 2) C and (50 10) % relative humidity, during 28 d 3 h.7.3 Specific conditioningAfter preconditioning according to 7.2, the test specimens are placed in the ventilated oven (5.7), using the following procedure.a) In case of several tested sealants, only the same chemical family sealants shall be placed in the oven in the same conditioning time.b) All test specimens shall b

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有