1、 ETSI EN 300 019-2-1 V2.3.1 (2017-11) Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-1: Specification of environmental tests; Storage EUROPEAN STANDARD ETSI ETSI EN 300 019-2-1 V2.3.1 (2017-11)2 Reference REN/EE-0170 Keywords
2、 environment, equipment practice, testing ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Important notice The p
3、resent document can be downloaded from: http:/www.etsi.org/standards-search The present document may be made available in electronic versions and/or in print. The content of any electronic and/or print versions of the present document shall not be modified without the prior written authorization of
4、ETSI. In case of any existing or perceived difference in contents between such versions and/or in print, the only prevailing document is the print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware tha
5、t the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at https:/portal.etsi.org/TB/ETSIDeliverableStatus.aspx If you find errors in the present document, please send your comment to one of the following services
6、: https:/portal.etsi.org/People/CommiteeSupportStaff.aspx Copyright Notification No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm except as authorized by written permission of ETSI. The content of the PDF version shall
7、not be modified without the written authorization of ETSI. The copyright and the foregoing restriction extend to reproduction in all media. ETSI 2017. All rights reserved. DECTTM, PLUGTESTSTM, UMTSTMand the ETSI logo are trademarks of ETSI registered for the benefit of its Members. 3GPPTM and LTE ar
8、e trademarks of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. oneM2M logo is protected for the benefit of its Members. GSM and the GSM logo are trademarks registered and owned by the GSM Association. ETSI ETSI EN 300 019-2-1 V2.3.1 (2017-11)3 Contents Intell
9、ectual Property Rights 4g3Foreword . 4g3Modal verbs terminology 5g31 Scope 6g32 References 6g32.1 Normative references . 6g32.2 Informative references 6g33 Definitions 7g34 Environmental test specifications . 7g34.0 General . 7g34.1 Equipment setup and configuration 7g34.2 Performance criteria . 7g3
10、4.3 Specification T 1.1: Weatherprotected, partly temperature-controlled storage locations . 8g34.4 Specification T 1.2: Weatherprotected, not temperature-controlled storage locations . 11g34.5 Specification T 1.3: Non-weatherprotected storage locations and T 1.3 E: Non-weatherprotected storage loca
11、tions - extended 14g3Annex A (informative): Bibliography . 21g3History 22g3ETSI ETSI EN 300 019-2-1 V2.3.1 (2017-11)4 Intellectual Property Rights Essential patents IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these ess
12、ential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updat
13、es are available on the ETSI Web server (https:/ipr.etsi.org/). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web serve
14、r) which are, or may be, or may become, essential to the present document. Trademarks The present document may include trademarks and/or tradenames which are asserted and/or registered by their owners. ETSI claims no ownership of these except for any which are indicated as being the property of ETSI
15、, and conveys no right to use or reproduce any trademark and/or tradename. Mention of those trademarks in the present document does not constitute an endorsement by ETSI of products, services or organizations associated with those trademarks. Foreword This European Standard (EN) has been produced by
16、 ETSI Technical Committee Environmental Engineering (EE). The present document is part 2, sub-part 1 of a multi-part deliverable covering the environmental conditions and environmental tests for telecommunications equipment, as identified below: Part 1: “Classification of environmental conditions“;
17、Part 2: “Specification of environmental tests“: Sub-part 0: “Introduction“; Sub-part 1: “Storage“; Sub-part 2: “Transportation“; Sub-part 3: “Stationary use at weatherprotected locations“; Sub-part 4: “Stationary use at non-weatherprotected locations“; Sub-part 5: “Ground vehicle installations“; Sub
18、-part 6: “Ship environments“; Sub-part 7: “Portable and non-stationary use“; Sub-part 8: “Stationary use at underground locations“. Part 1 specifies different standardized environmental classes covering climatic and biological conditions, chemically and mechanically active substances and mechanical
19、conditions during storage, transportation and in use. Part 2 specifies the recommended test severities and test methods for the different environmental classes. ETSI ETSI EN 300 019-2-1 V2.3.1 (2017-11)5 National transposition dates Date of adoption of this EN: 27 November 2017 Date of latest announ
20、cement of this EN (doa): 28 February 2018 Date of latest publication of new National Standard or endorsement of this EN (dop/e): 31 August 2018 Date of withdrawal of any conflicting National Standard (dow): 31 August 2018 Modal verbs terminology In the present document “shall“, “shall not“, “should“
21、, “should not“, “may“, “need not“, “will“, “will not“, “can“ and “cannot“ are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of provisions). “must“ and “must not“ are NOT allowed in ETSI deliverables except when used in direct citation. ETSI
22、ETSI EN 300 019-2-1 V2.3.1 (2017-11)6 1 Scope The present document specifies test severities and methods for verification of the required resistibility of equipment according to the relevant environmental class. The tests defined in the present document apply to storage of equipment covering the env
23、ironmental conditions stated in ETSI EN 300 019-1-1 1. 2 References 2.1 Normative references References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific reference
24、s, the latest version of the referenced document (including any amendments) applies. Referenced documents which are not found to be publicly available in the expected location might be found at https:/docbox.etsi.org/Reference/. NOTE: While any hyperlinks included in this clause were valid at the ti
25、me of publication, ETSI cannot guarantee their long term validity. The following referenced documents are necessary for the application of the present document. 1 ETSI EN 300 019-1-1 (2014): “Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equi
26、pment; Part 1-1: Classification of environmental conditions; Storage“. 2 Void. 3 Void. 4 IEC 60068-2-1:2007: “Environmental testing - Part 2-1: Tests - Test A: Cold“. 5 IEC 60068-2-2:2007: “Environmental testing - Part 2-2: Tests - Test B: Dry heat“. 6 IEC 60068-2-6:2007: “Environmental testing - Pa
27、rt 2-6: Tests - Test Fc: Vibration (sinusoidal)“. 7 IEC 60068-2-14:2009: “Environmental testing - Part 2-14: Tests - Test N: Change of temperature“. 8 IEC 60068-2-18:2017: “Environmental testing - Part 2-18: Tests - Test R and guidance: Water“. 9 IEC 60068-2-27:2008: “Environmental testing. Part 2-2
28、7: Tests - Test Ea and guidance: Shock“. 10 IEC 60068-2-30:2005: “Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 + 12 hour cycle)“. 11 IEC 60068-2-78:2012: “Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state“. 12 IEC 60068-2-64:2008: “Environmenta
29、l testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance“. 2.2 Informative references References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-s
30、pecific references, the latest version of the referenced document (including any amendments) applies. ETSI ETSI EN 300 019-2-1 V2.3.1 (2017-11)7 NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee their long term validity. The following ref
31、erenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. i.1 ETSI EN 300 019-2-0 (2003): “Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part
32、2-0: Specification of environmental tests; Introduction“. i.2 IEC 60068-2-68:1994: “Environmental testing - Part 2-68: Tests - Test L: Dust and sand“. i.3 ETSI EN 300 019-1-0: “Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1-0
33、: Classification of environmental conditions; Introduction“. 3 Definitions For the purposes of the present document, the terms and definitions given in ETSI EN 300 019-1-0 i.3 apply. 4 Environmental test specifications 4.0 General The equipment shall be tested in the state in which it is normally st
34、ored where this is possible. For example, if the detailed descriptions of the environmental conditions are given in clauses 4 and 5 of ETSI EN 300 019-1-1 1. ETSI EN 300 019-2-0 i.1 forms a general overview of part 2 of this multi-part deliverable. If the equipment is normally stored in a packed sta
35、te then it shall be tested in its packaging. 4.1 Equipment setup and configuration The equipment shall be tested in the state in which it is normally stored where this is possible. For example, if the equipment is stored in a packed state, then it shall be tested in its packaging. If the equipment c
36、an be stored both with and without its packaging it is necessary to perform tests for both configurations. For some tests and equipment, the test may be more severe for the packaged rather than the unpacked equipment. For example, for an equipment in a sealed package, the change of temperature test
37、may produce condensation. 4.2 Performance criteria The following performance criterion A shall apply in the tests defined by the present document. Performance criterion A: The equipment, or piece of equipment, shall be verified before and after the tests. The equipment shall function according to th
38、e manufacturer specifications before and after the test. No electrical or mechanical damages shall be allowed due to the application of the tests. ETSI ETSI EN 300 019-2-1 V2.3.1 (2017-11)8 4.3 Specification T 1.1: Weatherprotected, partly temperature-controlled storage locations The specifications
39、in tables 1 and 2 shall apply to weatherprotected or partially weather-controlled storage locations having partially temperature or humidity control described in ETSI EN 300 019-1-1 1. Table 1: Test specification T 1.1: Weatherprotected, partly temperature-controlled storage locations - climatic tes
40、ts Environmental parameter Environmental Class 1.1 Environmental test specification T1.1: Weatherprotected, partly temperature-controlled storage locations Type Parameter Detail parameter Characteristic Severity Test severity Duration Reference Method Performance criteria Notes low (C) -5 -5 72 h IE
41、C 60068-2-1 4 Ab: Cold A Air temperature high (C) +45 +45 or +55 72 h IEC 60068-2-2 5 Bb: Dry heat A 1 change (C/min) 0,5 None 2 low (%) 5 None 7 relative high (%) (C) 95 93 +30 96 h IEC 60068-2-78 11 Cab: Damp heat steady state A 3 Humidity condensation Yes None 4 absolutelow (g/m3) 1 None 7 high (
42、g/m3) 29 5 pressure low (kPa) 70 None 6 Air high (kPa) 106 None 6 speed (m/s) 1 None 7 rain intensity no Water low temperature no other sources no icing 10 - 50; 50 - 100 3 3 x 30 minutes IEC 60068-2-64 12 Fh: Vibration, broad-band random (digital control) A 2 Shocks shocks shock spectrum duration (
43、ms) acceleration (m/s2) number of shocks directions of shocks Type L 22 40 None 3 Load static load (kPa) 5 None 4 Legenda: no = this condition does not occur in this class. NOTE 1: (Vibration, sinusoidal) The characteristic severities are given as peak values. The test severity values defined for th
44、is phenomenon are not specified in IEC 60068-2-6 6. NOTE 2: (Vibration, random) ASD (Acceleration Spectral Density). Random vibration testing method may be used instead of the sinusoidal vibration test. The test severity values are not specified in IEC 60068-2-64 12. The maximum test frequency has b
45、een reduced because between 100 Hz and 200 Hz the contribution is insignificant. classes: 1.1 and 1.2 class: 1.3 Acceleration RMS (for information only) 1,06 m/s21,5 m/s2NOTE 3: (Shocks) No test is required because this condition is covered by transportation test for packaged equipment and by in-use
46、 test for unpackaged equipment. NOTE 4: (Load) Packaging and/or equipment should be designed taking into account this requirement but no tests are required. ETSI ETSI EN 300 019-2-1 V2.3.1 (2017-11)11 4.4 Specification T 1.2: Weatherprotected, not temperature-controlled storage locations The specifi
47、cations in tables 3 and 4 shall apply to weatherprotected or partially weatherprotected storage locations having neither temperature nor humidity control described in ETSI EN 300 019-1-1 1. Table 3: Test specification T 1.2: Weatherprotected, not temperature-controlled storage locations - climatic t
48、ests Environmental parameter Environmental Class 1.2 Environmental test specification T1.2: Weatherprotected, not temperature-controlled storage locations Type Parameter Detail parameter Characteristic severity Test severity Duration Reference Method Performance criterion Notes low (C) -25 -25 72 h
49、IEC 60068-2-1 4 Ab: Cold A Air high (C) +55 +55 or +70 72 h IEC 60068-2-2 5 Bb: Dry heat A 1 temperature change (C/min) 0,5 None 2 low (%) 10 one 8 relative high (%) (C) 100 93 +30 96 h IEC 60068-2-78 11 Cab: Damp heat steady state A 3 Humidity condensation (%) (C) yes 90-100 +30 2 cycles IEC 60068-2-30 10 Db: Damp heat cyclic Variant 1 A 5 absolute low (g/m3) 0,5 None 8 high (g/m3) 29 None 4 pressure low (kPa) 70 None 7 Air high (kPa) 106 None 7 speed (m/s) 30 one 8 rain intensity n