ETSI EN 300 119-4-2004 Environmental Engineering (EE) European telecommunication standard for equipment practice Part 4 Engineering requirements for subracks in miscellaneous racks.pdf

上传人:bonesoil321 文档编号:727869 上传时间:2019-01-09 格式:PDF 页数:11 大小:40.65KB
下载 相关 举报
ETSI EN 300 119-4-2004 Environmental Engineering (EE) European telecommunication standard for equipment practice Part 4 Engineering requirements for subracks in miscellaneous racks.pdf_第1页
第1页 / 共11页
ETSI EN 300 119-4-2004 Environmental Engineering (EE) European telecommunication standard for equipment practice Part 4 Engineering requirements for subracks in miscellaneous racks.pdf_第2页
第2页 / 共11页
ETSI EN 300 119-4-2004 Environmental Engineering (EE) European telecommunication standard for equipment practice Part 4 Engineering requirements for subracks in miscellaneous racks.pdf_第3页
第3页 / 共11页
ETSI EN 300 119-4-2004 Environmental Engineering (EE) European telecommunication standard for equipment practice Part 4 Engineering requirements for subracks in miscellaneous racks.pdf_第4页
第4页 / 共11页
ETSI EN 300 119-4-2004 Environmental Engineering (EE) European telecommunication standard for equipment practice Part 4 Engineering requirements for subracks in miscellaneous racks.pdf_第5页
第5页 / 共11页
点击查看更多>>
资源描述

1、 ETSI EN 300 119-4 V2.1.1 (2004-09)European Standard (Telecommunications series) Environmental Engineering (EE);European telecommunication standard for equipment practice;Part 4: Engineering requirements forsubracks in miscellaneous racks and cabinetsETSI ETSI EN 300 119-4 V2.1.1 (2004-09) 2 Referen

2、ce REN/EE-TMG006 Keywords equipment practice, environment, rack ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88

3、Important notice Individual copies of the present document can be downloaded from: http:/www.etsi.org The present document may be made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between such versions, the reference version i

4、s the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status.

5、Information on the current status of this and other ETSI documents is available at http:/portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following services: http:/portal.etsi.org/chaircor/ETSI_support.asp Copyright Notification

6、No part may be reproduced except as authorized by written permission. The copyright and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2004. All rights reserved. DECTTM, PLUGTESTSTM and UMTSTM are Trade Marks of ETSI registered for the

7、benefit of its Members. TIPHONTMand the TIPHON logo are Trade Marks currently being registered by ETSI for the benefit of its Members. 3GPPTM is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. ETSI ETSI EN 300 119-4 V2.1.1 (2004-09) 3 Contents

8、Intellectual Property Rights4 Foreword.4 1 Scope 5 2 References 5 3 Dimensions for subracks 5 4 Accessibility.6 5 Weight 6 5.1 Unequipped subrack.6 5.2 Equipped subrack .6 6 Electromagnetic compatibility and electrostatic discharge requirements 6 Annex A (informative): Illustrative figures8 Annex B

9、(informative): Bibliography.10 History 11 ETSI ETSI EN 300 119-4 V2.1.1 (2004-09) 4 Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI

10、members and non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/webap

11、p.etsi.org/IPR/home.asp). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become

12、, essential to the present document. Foreword This European Standard (Telecommunications series) has been produced by ETSI Technical Committee Environmental Engineering (EE). The present document is part 4 of a multi-part deliverable aimed at setting out, on a common basis, the engineering requireme

13、nts for telecommunication practice, for housing equipment forming part of a public telecommunications network. EN 300 119-1 2 is a general introduction and explains the terminology used. EN 300 119-2 3 specifies the engineering requirements for racks and cabinets and EN 300 119-3 4 specifies the eng

14、ineering requirements for miscellaneous racks and cabinets. EN 300 119-5 5 covers the preferred thermal management solutions for subracks, racks/cabinets and miscellaneous racks/cabinets installed indoors in restricted access locations, for the removal of heat dissipated by one or more subracks in a

15、n rack complying to the requirements of this multi-part standard. The present document specifies the engineering requirements for subracks mounted in miscellaneous racks and cabinets. The present document applies to all telecommunications equipment forming part of the public telecommunications netwo

16、rk. Illustrative figures are contained in annex A. The present document is part 4 of a multi-part deliverable. Full details of the entire series can be found in part 1 2. National transposition dates Date of adoption of this EN: 24 September 2004 Date of latest announcement of this EN (doa): 31 Dece

17、mber 2004 Date of latest publication of new National Standard or endorsement of this EN (dop/e): 30 June 2005 Date of withdrawal of any conflicting National Standard (dow): 30 June 2005 ETSI ETSI EN 300 119-4 V2.1.1 (2004-09) 5 1 Scope The present document details requirements for subracks for use i

18、n miscellaneous racks/cabinets, as described in EN 300 119-3 4. The subrack will normally be supplied as a fully assembled structure, unequipped, partially equipped or fully equipped with plug-in units, etc. 2 References The following documents contain provisions which, through reference in this tex

19、t, constitute provisions of the present document. References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For a specific reference, subsequent revisions do not apply. For a non-specific reference, the latest version applies. Referen

20、ced documents which are not found to be publicly available in the expected location might be found at http:/docbox.etsi.org/Reference. 1 Council Directive 89/336/EEC of 3 May 1989 on the approximation of the laws of the Member States relating to electromagnetic compatibility. 2 ETSI EN 300 119-1: “E

21、nvironmental Engineering (EE); European telecommunication standard for equipment practice; Part 1: Introduction and terminology“. 3 ETSI EN 300 119-2: “Environmental Engineering (EE); European telecommunication standard for equipment practice; Part 2: Engineering requirements for racks and cabinets“

22、. 4 ETSI EN 300 119-3: “Environmental Engineering (EE); European telecommunication standard for equipment practice; Part 3: Engineering requirements for miscellaneous racks and cabinets“. 5 ETSI EN 300 119-5: “Environmental Engineering (EE); European telecommunication standard for equipment practice

23、; Part 5: Thermal management“. 6 IEC publication 60917-2-2: “Modular order for the development of mechanical structures for electronic equipment practices - Part 2: Sectional specification - Interface co-ordination dimensions for the 25 mm equipment practice - Section 2: Detail specification - Dimen

24、sions for subracks, chassis, backplanes, front panels and plug-in units“. 3 Dimensions for subracks The dimensions height H, width W and depth D1 and D2 of the equipped subrack shall include all plug-in units, switches, lamps, cooling fans, connectors, etc. For a table of dimensions, see table 1 and

25、 refer to figures A.1 and A.2. ETSI ETSI EN 300 119-4 V2.1.1 (2004-09) 6 4 Accessibility Subracks fitting in a miscellaneous rack/cabinet of depth 300 mm shall require access only from the front, so that they can be placed in miscellaneous racks/cabinets which are back to back or against a wall. 5 W

26、eight 5.1 Unequipped subrack Unequipped subracks shall have a maximum weight of 18 kg for safe handling. Supply of subracks exceeding 18 kg, if requested, shall be agreed between the supplier and user. 5.2 Equipped subrack On demand, the supplier shall provide administrations, operators or customers

27、 with the total weight of the equipped subrack to enable the fully equipped miscellaneous rack/cabinet weight to be determined for telecommunications centres and customer site floor loading calculations. 6 Electromagnetic compatibility and electrostatic discharge requirements Subracks to be installe

28、d in miscellaneous racks/cabinets must take account of the EEC Council Directive on the approximation of laws of the Member States relating to electromagnetic compatibility (Directive 89/336/EEC 1). In accordance with the terms of this Directive, due regard shall be taken of the appropriate existing

29、 and emerging standards concerning electromagnetic compatibility phenomena. NOTE: See also figures A.1 and A.2 where dimensions are in mm. ETSI ETSI EN 300 119-4 V2.1.1 (2004-09) 7 Table 1 Dimensions for subracks mounted in miscellaneous racks/cabinets (see note 2) H = height C n x 25 W1 = overall w

30、idth over flanges C 535 (see note 1) 535 W2 = width C 450 500 W3 = mounting centre distance A 515 (see note 1) 515 R = mounting position C 12,5 + n x 25 12,5 + n x 25 S = mounting pitch A n x 25 n x 25 D1 = mounting C rack 300 deep rack 600 deep rack 300 deep rack 600 deep depth (front) 40 75 40 75

31、D2 = mounting depth (rear) C 240 470 240 470 NOTE 1: Subracks with dimensions W1 = 485 and W3 = 465 may be fitted into miscellaneous racks (EN 300 119-3 4) by the use of adaptors. NOTE 2: A = Actual dimension. Tolerances needed for W3 and S are specified in IEC 60917-2-2 6. C = Coordination dimensio

32、n. NOTE 3: n = 0, 1, 2, 3, etc. (the value of n can be different for H, R and S). Definition: A coordination dimension is a reference dimension used to coordinate mechanical interfaces. This is not a manufacturing dimension with a tolerance. An aperture dimension is a special coordination dimension

33、for a usable space between features. An actual outside dimension corresponding to a coordination dimension can only decrease. An actual inside dimension corresponding to an aperture dimension can only increase. ETSI ETSI EN 300 119-4 V2.1.1 (2004-09) 8 Annex A (informative): Illustrative figures Fig

34、ure A.1: Subrack ETSI ETSI EN 300 119-4 V2.1.1 (2004-09) 9 Figure A.2: Subrack ETSI ETSI EN 300 119-4 V2.1.1 (2004-09) 10Annex B (informative): Bibliography ETSI EN 300 019: “Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment“. ETSI ETSI EN 300 119-4 V2.1.1 (2004-09) 11History Document history Edition 1 January 1994 Publication as ETS 300 119-4 V2.1.0 May 2004 One-step Approval Procedure OAP 20040924: 2004-05-26 to 2004-09-24 V2.1.1 September 2004 Publication