ETSI EN 300 396-8-4-2001 Terrestrial Trunked Radio (TETRA) Technical Requirements for Direct Mode Operation (DMO) Part 8 Protocol Implementation Conformance Statement (PICS) Profor_1.pdf

上传人:花仙子 文档编号:728506 上传时间:2019-01-09 格式:PDF 页数:46 大小:1.74MB
下载 相关 举报
ETSI EN 300 396-8-4-2001 Terrestrial Trunked Radio (TETRA) Technical Requirements for Direct Mode Operation (DMO) Part 8 Protocol Implementation Conformance Statement (PICS) Profor_1.pdf_第1页
第1页 / 共46页
ETSI EN 300 396-8-4-2001 Terrestrial Trunked Radio (TETRA) Technical Requirements for Direct Mode Operation (DMO) Part 8 Protocol Implementation Conformance Statement (PICS) Profor_1.pdf_第2页
第2页 / 共46页
ETSI EN 300 396-8-4-2001 Terrestrial Trunked Radio (TETRA) Technical Requirements for Direct Mode Operation (DMO) Part 8 Protocol Implementation Conformance Statement (PICS) Profor_1.pdf_第3页
第3页 / 共46页
ETSI EN 300 396-8-4-2001 Terrestrial Trunked Radio (TETRA) Technical Requirements for Direct Mode Operation (DMO) Part 8 Protocol Implementation Conformance Statement (PICS) Profor_1.pdf_第4页
第4页 / 共46页
ETSI EN 300 396-8-4-2001 Terrestrial Trunked Radio (TETRA) Technical Requirements for Direct Mode Operation (DMO) Part 8 Protocol Implementation Conformance Statement (PICS) Profor_1.pdf_第5页
第5页 / 共46页
点击查看更多>>
资源描述

1、ETSI EN 300 396-8-4 VI .I .I (2001-01) European Standard (Telecommunications series) Terrestrial Trunked Radio (TETRA); Technical requirements for Direct Mode Operation (DMO); Part 8: Protocol Implementation Conformance Statement (PICS) proforma specification; Sub-part 4: Type 2 repeater Air Interfa

2、ce (AI) 2 ETSI EN 300 396-8-4 V1.l.l (2001-01) Th Reference DENITETRA-02007-8-4 Keywords DMO, ICs, PICS, radio, TETRA ETSI 650 Route des Lucioles F-O6921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 O0 Fax: +33 4 93 65 47 16 Siret No 348 623 562 00017 - NAF 742 C Association but non lucratif

3、 enregistre la Sous-prfecture de Grasse (06) No 7803/88 Important notice Individual copies of the present document can be downloaded from: htti3:lwww. etsi I oq present document may be made available in more than one electronic version or in print. I any cas Df existing perceived difference in conte

4、nts between such versions, the reference version is the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the documen

5、t may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at If you find errors in the present document, send your comment to: editor etsi.fr Copyright Notification No part may be reproduced except as authorized by written permi

6、ssion. The copyright and the foregoing restriction extend to reproduction in all media. 8 European Telecommunications Standards Institute 2001. All rights reserved. ETSI 3 ETSI EN 300 396-8-4 V1.l.l (2001-01) Contents Intellectual Property Rights 5 Foreword 5 Introduction 6 1 Scope 7 2 References 7

7、3 Definitions and abbreviations 7 3.1 Definitions 7 3.2 Abbreviations 8 4 Conformance to this PICS proforma specification . 8 Annex A (normative): A . 1 A.l.l A . 1.2 A.1.3 A.2 A.2.1 A.2.2 A.2.3 A.2.4 A.2.5 A.2.6 A . 3 A.4 AS A . 6 A.6.1 A.6.1.1 A.6.1.2 A.6.1.3 A.6.1.4 A.6.1.5 A.6.1.6 A.6.1.7 A.6.1.

8、8 A.6.1.9 Protocol ICs proforma (PICS) for EN 300 396-4 . 9 Guidance for completing the PICS proforma . 9 Instructions for completing the PICS proforma 11 Identification of the implementation 11 Date of the statement . 11 Implementation Under Test (IUT) identification 11 System Under Test (SUT) iden

9、tification 12 Purposes and structure . 9 Abbreviations and conventions 9 Product supplier 12 Client (if different from product supplier) 12 PICS contact person 13 Identification of the Protocol . 13 Global statement of conformance 13 Roles 14 Protocols for DM-MS supporting operation with a type 2 DM

10、-REP (MS-REP2) . 14 MS-REP2 Direct Mode Call Control (DMCC) at Layer 3 . 14 A.6.1.10 A.6.1.11 A.6.2 A.6.2.1 A.6.2.2 A.6.2.3 A.6.2.4 A.6.2.5 A.6.2.6 DMCC major capabilities . 14 Circuit mode call 15 Circuit mode call Set-up . 15 Circuit mode services offered . 16 Short data services . 16 Type of shor

11、t data service . 17 Data transmission . 18 SDS user defined data 18 DMCC PDUs . 19 DMCC constants 21 DMCC timers 22 MS-REP2 Data link layer (DLL) at Layer 2 . 23 MS-REP2 MAC features 23 MS-REP2 MAC PDUs . 27 MS-REP2 MAC generated messages 28 MS-REP2 MAC constants 28 MS-REP2 MAC timers 30 MS-REP2-MAC

12、 procedures . 23 A.7 A.7.1 DM-REP2 Data link layer (DLL) at Layer 2 31 A.7.1.1 Major services 31 A.7.1.2 DM-REP2 MAC features . 31 DM-REP type 2 Protocol (DM-REP2) 31 ETSI 4 ETSI EN 300 396-8-4 V1.l.l (2001-01) A.7.1.3 A.7.1.5 A.7.1.6 A.7.1.7 A.8 DM-REP2 MAC procedures . 32 DM-REP2 MAC generated mes

13、sages . 34 DM-REP2 MAC constants . 34 DM-REP2 MAC timers 35 PDU parameters for MS-REP2 and DM-REP2 used in DMCC at layer 3 and DLL at layer 2 36 A.7.1.4 DM-REP2 MAC PDUS 34 A.8.1 A.8.1.1 A.8.1.2 A.8.1.3 A.8.1.4 A.8.1.5 A.8.1.6 A.8.1.7 A.8.1.8 A.8.1.9 A.8.1.10 A.8.1.11 A.8.1.12 A.8.1.13 A.8.1.14 A.8.

14、1.15 A.8.1.16 A.8.1.17 A.8.2 A.8.2.1 A.8.2.2 A.8.2.3 A.8.2.4 A.8.2.5 A.8.2.6 A.8.3 A.8.3.1 A.8.3.2 A.8.3.3 A.8.3.4 MS-REP2 PDU parameters for DMCC at layer 3 . 36 DM-SETUP . 36 DM-SETUP PRES . 36 DM-CONNECT . 37 DM-DISCONNECT . 37 DM-CONNECT ACK 37 DM-OCCUPIED 38 DM-RELEASE 38 DM-TX CEASED 38 DM-TX

15、REQUEST 39 DM-TX ACCEPT 39 DM-PREEMPT . 39 DM-PRE ACCEPT 39 DM-REJECT . 39 DM-INFO 40 DM-SDS UDATA . 40 DM-SDS DATA 41 DM-SDS ACK . 41 MS-REP2 and DM-REP2 PDU parameters for DLL at layer 2 . 42 DMAC-SYNC in SCWS 42 DPRES-SYNC PDU 43 DMAC-DATA . 44 DMAC-FRAG . 44 DMAC-END 44 DMAC-U SIGNAL 44 DM-MAC g

16、enerated message parameters 45 DM-RESERVED . 45 DM-SDS OCCUPIED 45 DM-TIMING REQUEST . 45 DM-TIMING ACK 45 History . 46 ETSI 5 ETSI EN 300 396-8-4 V1.l.l (2001-01) Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The informa

17、tion pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR O00 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ET

18、SI Secretariat. Latest updates are available on the ETSI Web server ClattD:/www.etsP.c/iDr. Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR O00 314 (or the u

19、pdates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This European Standard (Telecommunications series) has been produced by ETSI Project Terrestrial Trunked Radio (TETRA). The present document had been submitted to Public Enquiry as ETS 300

20、 396-8-4. During the processing for Vote it was converted into an EN. The present document is part 8 of a multi-part deliverable covering the Terrestrial Trunked Radio (TETRA); Technical requirements for Direct Mode Operation (DMO); as identified below: Part 1: “General network design“; Part 2: “Rad

21、io aspects“; Part 3: “Mobile Station to Mobile Station (MS-MS) Air Interface (AI) protocol“; Part 4: “Type 1 repeater air interface“; Part 5: “Gateway air interface“; Part 6: “Security“; Part 7: “Type 2 repeater air interface“; Part 8: “Protocol Implementation Conformance Statement (PICS) proforma s

22、pecification“; Part 9: “Service and Description Language (SDL) model“; Part 10: “Managed Direct Mode Operation (DMO)“. National transposition dates Date of adoption of this EN Date of latest announcement of this EN (doa): Date of latest publication of new National Standard or endorsement of this EN

23、(dop/e): Date of withdrawal of any conflicting National Standard (dow): 22 December 2000 31 March 2001 30 September 2001 30 September 2001 ETSI 6 ETSI EN 300 396-8-4 V1.l.l (2001-01) Introduction To evaluate conformance of a particular implementation, it is necessary to have a statement of which cap

24、abilities and options have been implemented for a telecommunication specification. Such a statement is called an Implementation Conformance Statement (ICs). ETSI 7 ETSI EN 300 396-8-4 V1.l.l (2001-01) 1 Scope The present documet provides the Protocol Implementation Conformance Statement (PICS) profo

25、rma for TETRA Direct Mode Operation (DMO) Mobile Stations (MS) connected to Type 2 repeater (MS-REP2) and for TETRA Direct Mode Operation Type 2 repeater (DM-REP2), defined in EN 300 396-7 i in compliance with the relevant requirements, and in accordance with the relevant guidance given in ISO/IEC 9

26、646-7 6 and ETS 300 406 4. 2 References The following documents contain provisions which, through reference in this text, constitute provisions of the present documen t. References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. For a sp

27、ecific reference, subsequent revisions do not apply. For a non-specific reference, the latest version applies. u1 ETSI EN 300 396-7: “Terrestrial Trunked Radio (TETRA); Technical requirements for Direct Mode Operation (DMO); Part 7: Type 2 repeater air interface“. ETSI ETS 300 396-3: “Terrestrial Tr

28、unked Radio (TETRA); Technical requirements for Direct Mode Operation (DMO); Part 3: Mobile Station to Mobile Station (MS-MS) Air Interface (AI) protocol“. 121 131 ETSI EN 300 396-8-2: “Terrestrial Trunked Radio (TETRA); Technical requirements for Direct Mode Operation (DMO); Part 8: Protocol Implem

29、entation Conformance Statement (PICS) proforma specification; Sub-part 2: Type 1 repeater Air Interface (AI)“. ETSI ETS 300 406: “Methods for Testing and Specification (MTS); Protocol and profile conformance testing specifications; Standardization methodology“. ISO/IEC 9646-1 (1994): “Information te

30、chnology - Open systems interconnection - Conformance testing methodology and framework - Part 1: General concepts“. ISO/IEC 9646-7 (1995): “Information technology - Open systems interconnection - Conformance testing methodology and framework - Part 7: Implementation Conformance Statements“. ETSI EN

31、 300 396-4: “Terrestrial Trunked Radio (TETRA); Technical requirements for Direct Mode Operation (DMO); Part 4: Type 1 repeater air interface“. 3 3.1 Definitions and abbreviations Def i n it ions For the purposes of the present document, the terms and definitions given in EN 300 396-4 7, ISO/IEC 964

32、6-1 5, ISO/IEC 9646-7 6 and the following apply. Implementation Conformance Statement (ICs): statement made by the supplier of an implementation or system claimed to conform to a given specification, stating which capabilities have been implemented. The ICs can take several forms: protocol ICs, prof

33、ile ICs, profile specific ICs, information object ICs, etc. ICs proforma: document, in the form of a questionnaire, which when completed for an implementation or system becomes an ICs Protocol ICs (PICS): ICs for an implementation or system claimed to conform to a given protocol specification ETSI 8

34、 ETSI EN 300 396-8-4 V1.l.l (2001-01) 3.2 Abbreviations For the purposes of the present document, the following abbreviations apply: ICs Implementation Conformance Statement IUT Implementation Under Test PICS Protocol Implementation Conformance Statement SCS System Conformance Statement SUT System U

35、nder Test 4 Conformance to this PICS proforma specification If it claims to conform to the present document, the actual PICS proforma to be filled in by a supplier shall be technically equivalent to the text of the PICS proforma given in annex A, and shall preserve the numberinghaming and ordering o

36、f the proforma items. A PICS which conforms to the present document shall be a conforming PICS proforma completed in accordance with the guidance for completion given in clause A. 1. ETSI 9 ETSI EN 300 396-8-4 V1.l.l (2001-01) Annex A (normative): Protocol ICs proforma (PICS) for EN 300 396-4 Notwit

37、hstanding the provisions of the copyright clause related to the text of the present document, ETSI grants that users of the present document may freely reproduce the PICS proforma in this annex so that it can be used for its intended purposes and may further publish the completed PICS. A.l Guidance

38、for completing the PICS proforma A.1 .I Purposes and structure The purpose of this PICS proforma is to provide a mechanism whereby a supplier of an implementation of the requirements defined in EN 300 396-7 i may provide information about the implementation in a standardized manner. The PICS proform

39、a is subdivided into clauses for the following categories of information: guidance for completing the PICS proforma; identification of the implementation; identification of the Protocol; global statement of conformance; identification of the roles, MS-REP2 or DM-REP2; MS-REP2 layer 3 protocol part;

40、MS-REP2 protocol layer 2 part; DM-REP2 part. A. 1.2 Abbreviations and conventions The PICS proforma contained in this annex is comprised of information in tcdar form in accor-mce with the guidelines presented in ISO/IEC 9646-7 6. Item column The item column contains a number which identifies the ite

41、m in the table. Item description column The item description column describes in free text each respective item (e.g. parameters, timers, etc.). It implicitly means “is supported by the implementation?“. Status column The following notations, defined in ISO/IEC 9646-7 6, are used for the status colu

42、mn: m O n/a X mandatory - the capability is required to be supported; optional - the capability may be supported or not; not applicable - in the given context, it is impossible to use the capability; prohibited (excluded) - there is a requirement not to use this capability in the given context; ETSI

43、 10 ETSI EN 300 396-8-4 V1.l.l (2001-01) 0.i qualified optional - for mutually exclusive or selectable options from a set. “i“ is an integer which identifies a unique group of related optional items and the logic of their selection which is defined immediately following the table; conditional - the

44、requirement on the capability (“m“, “o“, “x“ or “n/a“) depends on the support of other optional or Conditional items. “i“ is an integer identifying a unique conditional status expression which is defined immediately following the table. ci Reference column The reference column makes reference to EN

45、300 396-7 i, except where explicitly stated otherwise. Support column The support column shall be filled in by the supplier of the implementation. The following common notations, defined in ISOAEC 9646-7 6, are used for the support column: Y or y N or n N/A, n/a or - supported by the implementation;

46、 not supported by the implementation; no answer required (allowed only if the status is n/a, directly or after evaluation of a conditional status). If this PICS proforma is completed in order to describe a multiple-profile support in a system, it is necessary to be able to answer that a capability i

47、s supported for one profile and not supported for another. In that case, the supplier shall enter the unique reference to a conditional expression, preceded by “?“ (e.g. ?3). This expression shall be given in the space for comments provided at the bottom of the table. It uses predicates defined in t

48、he SCS, each of which refers to a single profile and which takes the value TRUE if and only if that profile is to be used. EXAMPLE: ?3: IF prof1 THEN Y ELSE N It is also possible to provide a comment to an answer in the space provided at the bottom of the table. NOTE: As stated in ISO/IEC 9646-7 6,

49、support for a received PDU requires the ability to parse all valid parameters of that PDU. Supporting a PDU while having no ability to parse a valid parameter is non-conformant. Support for a parameter on a PDU means that the semantics of that parameter are supported. Values allowed column The values allowed column contains the type, the list, the range, or the length of values allowed. The following notations are used: range of values: example: 5 20 list of values: , , , example: 2,4, 6, 8, 9 example: llOlB, lOllB, 1111B example: OA“, 34H, 2F“ li

展开阅读全文
相关资源
猜你喜欢
  • BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf
  • BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf
  • BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf
  • BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf
  • BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf
  • BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf
  • BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf
  • BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf
  • BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1