ETSI EN 301 357-2-2008 Electromagnetic compatibility and Radio spectrum Matters (ERM) Cordless audio devices in the range 25 MHz to 2 000 MHz Part 2 Harmonized EN covering essentia.pdf

上传人:arrownail386 文档编号:729453 上传时间:2019-01-08 格式:PDF 页数:15 大小:74.76KB
下载 相关 举报
ETSI EN 301 357-2-2008 Electromagnetic compatibility and Radio spectrum Matters (ERM) Cordless audio devices in the range 25 MHz to 2 000 MHz Part 2 Harmonized EN covering essentia.pdf_第1页
第1页 / 共15页
ETSI EN 301 357-2-2008 Electromagnetic compatibility and Radio spectrum Matters (ERM) Cordless audio devices in the range 25 MHz to 2 000 MHz Part 2 Harmonized EN covering essentia.pdf_第2页
第2页 / 共15页
ETSI EN 301 357-2-2008 Electromagnetic compatibility and Radio spectrum Matters (ERM) Cordless audio devices in the range 25 MHz to 2 000 MHz Part 2 Harmonized EN covering essentia.pdf_第3页
第3页 / 共15页
ETSI EN 301 357-2-2008 Electromagnetic compatibility and Radio spectrum Matters (ERM) Cordless audio devices in the range 25 MHz to 2 000 MHz Part 2 Harmonized EN covering essentia.pdf_第4页
第4页 / 共15页
ETSI EN 301 357-2-2008 Electromagnetic compatibility and Radio spectrum Matters (ERM) Cordless audio devices in the range 25 MHz to 2 000 MHz Part 2 Harmonized EN covering essentia.pdf_第5页
第5页 / 共15页
点击查看更多>>
资源描述

1、 ETSI EN 301 357-2 V1.4.1 (2008-11)Harmonized European Standard (Telecommunications series) Electromagnetic compatibilityand Radio spectrum Matters (ERM);Cordless audio devices in the range 25 MHz to 2 000 MHz;Part 2: Harmonized EN covering essential requirementsof article 3.2 of the R Essential, or

2、 potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/webapp.etsi.org/IPR/home.asp). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been car

3、ried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This Harmonized European Standard (Telecommunications series) has b

4、een produced by ETSI Technical Committee Electromagnetic compatibility and Radio spectrum Matters (ERM). The present document has been produced by ETSI in response to a mandate from the European Commission issued under Council Directive 98/34/EC (as amended) i.2 laying down a procedure for the provi

5、sion of information in the field of technical standards and regulations. The present document is intended to become a Harmonized Standard, the reference of which will be published in the Official Journal of the European Communities referencing the Directive 1999/5/EC of the European Parliament and o

6、f the Council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (“the R Part 2: “Harmonized EN covering essential requirements of article 3.2 of the R cordless loudspeakers; consumer radio microphones in the range 863 MHz to 8

7、65 MHz; in-ear monitoring equipment using either 300 kHz bandwidth analogue modulation or 300 kHz, 600 kHz, 1 200 kHz digital FDMA modulation in the range 863 MHz to 865 MHz; in-vehicle cordless; personal cordless; broadband multi channel audio systems; Band II LPD. (low power devices) in the 87,5 M

8、Hz to 108 MHz range (Broadcasting Band II) using up to 200 kHz bandwidth and analogue modulation. and other devices and frequency bands defined within CEPT/ERC/REC 70-03 i.4 or European or National regulation. The frequency bands for this equipment may differ from country to country as specified in

9、their national regulations. All equipment is intended to be used with integral antennas. The present document is intended to cover the provisions of Directive 1999/5/EC i.1 (R - for informative references. Referenced documents which are not found to be publicly available in the expected location mig

10、ht be found at http:/docbox.etsi.org/Reference. ETSI ETSI EN 301 357-2 V1.4.1 (2008-11) 6For online referenced documents, information sufficient to identify and locate the source shall be provided. Preferably, the primary source of the referenced document should be cited, in order to ensure traceabi

11、lity. Furthermore, the reference should, as far as possible, remain valid for the expected life of the document. The reference shall include the method of access to the referenced document and the full network address, with the same punctuation and use of upper case and lower case letters. NOTE: Whi

12、le any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee their long term validity. 2.1 Normative references The following referenced documents are indispensable for the application of the present document. For dated references, only the edition cited appl

13、ies. For non-specific references, the latest edition of the referenced document (including any amendments) applies. 1 ETSI EN 301 357-1 (V1.4.1): “Electromagnetic compatibility and Radio spectrum Matters (ERM); Cordless audio devices in the range 25 MHz to 2 000 MHz; Part 1: Technical characteristic

14、s and test methods“. 2 ETSI TR 100 028 (all parts) (V1.4.1): “Electromagnetic compatibility and Radio spectrum Matters (ERM); Uncertainties in the measurement of mobile radio equipment characteristics“. 2.2 Informative references The following referenced documents are not essential to the use of the

15、 present document but they assist the user with regard to a particular subject area. For non-specific references, the latest version of the referenced document (including any amendments) applies. i.1 Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 on radio equipment

16、 and telecommunications terminal equipment and the mutual recognition of their conformity (R A guide to the production of candidate Harmonized Standards for application under the R the value of the measurement uncertainty for the measurement of each parameter shall be included in the test report; th

17、e recorded value of the measurement uncertainty shall be, for each measurement, equal to or lower than the figures in table 1. For the test methods, according to the present document, the measurement uncertainty figures shall be calculated in accordance with TR 100 028 2 and shall correspond to an e

18、xpansion factor (coverage factor) k = 1,96 or k = 2 (which provide confidence levels of respectively 95 % and 95,45 % in the case where the distributions characterizing the actual measurement uncertainties are normal (Gaussian). Table 1 is based on such expansion factors and gives the maximum allowa

19、ble measurement uncertainties applicable to measured parameters for cordless audio and radio microphones unless otherwise stated in the present document. Table 1: Maximum allowable measurement uncertainty for cordless audio and radio microphones Parameter Uncertainty RF frequency 1 x 10-7Audio Outpu

20、t power 0,5 dB Radiated RF power 6 dB Conducted RF power variations using a test fixture 0,75 dB Maximum frequency deviation: - within 300 Hz and 6 kHz of audio frequency 5 % - within 6 kHz and 25 kHz of audio frequency 3 dB Deviation limitation 5 % Radiated emission of transmitter, valid up to 12,7

21、5 GHz 6 dB Radiated emission of receiver, valid up to 12,75 GHz 6 dB Transmitter switch off time 5 % ETSI ETSI EN 301 357-2 V1.4.1 (2008-11) 10Table 2 gives the maximum allowable measurement uncertainties applicable to measured parameters for Band II LPD unless otherwise stated in the present docume

22、nt. Table 2: Maximum allowable measurement uncertainty for Band II LPD Parameter Uncertainty Effective Radiated Power 6 dB Occupied Bandwidth 6 dB Frequency Error 100 Hz Transmitter Timeout 10 seconds Radiated Spurious Emissions 6 dB 5.3 Essential radio test suites 5.3.1 Transmitter test suites for

23、Band II LPD All tests specified in EN 301 357-1 1, clause 8.2 shall be carried out for Band II LPD. These tests cover the following transmitter test suites for Band II LPD: effective radiated power; occupied bandwidth; frequency error; transmitter timeout and radiated spurious emissions. 5.3.2 Frequ

24、ency error The test specified in EN 301 357-1 1, clause 8.3 shall be carried out for general cordless audio devices. 5.3.3 Carrier power The test specified in EN 301 357-1 1, clause 8.4 shall be carried out for general cordless audio devices. 5.3.4 Channel bandwidth The test specified in EN 301 357-

25、1 1, clause 8.5 shall be carried out for general cordless audio devices. 5.3.5 Radiated spurious emissions and cabinet radiation The test specified in EN 301 357-1 1, clause 8.6 shall be carried out for general cordless audio devices. 5.3.6 Cordless audio transmitter shutoff The test specified in EN

26、 301 357-1 1, clause 8.7 shall be carried out for general cordless audio devices. 5.3.7 Receiver spurious emissions and cabinet radiation The test specified in EN 301 357-1 1, clause 9.1 shall be carried out for general cordless audio devices. ETSI ETSI EN 301 357-2 V1.4.1 (2008-11) 11Annex A (norma

27、tive): HS Requirements and conformance Test specifications Table (HS-RTT) The HS Requirements and conformance Test specifications Table (HS-RTT) in table A.1 serves a number of purposes, as follows: it provides a statement of all the requirements in words and by cross reference to (a) specific claus

28、e(s) in the present document or to (a) specific clause(s) in (a) specific referenced document(s); it provides a statement of all the test procedures corresponding to those requirements by cross reference to (a) specific clause(s) in the present document or to (a) specific clause(s) in (a) specific r

29、eferenced document(s); it qualifies each requirement to be either: - Unconditional: meaning that the requirement applies in all circumstances; or - Conditional: meaning that the requirement is dependent on the manufacturer having chosen to support optional functionality defined within the schedule;

30、in the case of Conditional requirements, it associates the requirement with the particular optional service or functionality; it qualifies each test procedure to be either: - Essential: meaning that it is included with the Essential Radio Test Suite and therefore the requirement shall be demonstrate

31、d to be met in accordance with the referenced procedures; - Other: meaning that the test procedure is illustrative but other means of demonstrating compliance with the requirement are permitted. Table A.1: HS Requirements and conformance Test specifications Table (HS-RTT) Harmonized Standard EN 301

32、357-2 The following requirements and test specifications are relevant to the presumption of conformity under the article 3.2 of the R those designated “O“ make up the Other Test Suite; for those designated “X“ there is no test specified corresponding to the requirement. The completion of all tests c

33、lassified “E“ as specified with satisfactory outcomes is a necessary condition for a presumption of conformity. Compliance with requirements associated with tests classified “O“ or “X“ is a necessary condition for presumption of conformity, although conformance with the requirement may be claimed by

34、 an equivalent test or by manufacturers assertion supported by appropriate entries in the technical construction file. Clause Number Identification of clause(s) defining the test specification in the present document unless another document is referenced explicitly Where no test is specified (that i

35、s, where the previous field is “X“) this field remains blank. ETSI ETSI EN 301 357-2 V1.4.1 (2008-11) 13Annex B (informative): The EN title in the official languages The enlargement of the European Union (EU) resulted in a requirement from the EU for a larger number of languages for the translation

36、of the titles of Harmonized Standards and mandated ENs that are to be listed in the Official Journal to support the implementation of this legislation. For this reason the title translation concerning the present document can be consulted via the e-approval application. ETSI ETSI EN 301 357-2 V1.4.1

37、 (2008-11) 14Annex C (informative): Bibliography Council Directive 89/336/EEC of 3 May 1989 on the approximation of the laws of the Member States relating to electromagnetic compatibility (EMC Directive). Council Directive 73/23/EEC of 19 February 1973 on the harmonization of the laws of Member Stat

38、es relating to electrical equipment designed for use within certain voltage limits (LV Directive). ETSI ETSI EN 301 357-2 V1.4.1 (2008-11) 15History Document history V1.1.1 August 2000 Publication V1.2.1 June 2001 Publication V1.3.1 July 2006 Publication V1.4.1 December 2007 Public Enquiry PE 20080418: 2007-12-19 to 2008-04-18 V1.4.1 September 2008 Vote V 20081109: 2008-09-10 to 2008-11-10 V1.4.1 November 2008 Publication

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1