ETSI EN 301 489-7-2005 Electromagnetic compatibility and Radio spectrum Matters (ERM) ElectroMagnetic Compatibility (EMC) standard for radio equipment and services Part 7 Specific .pdf

上传人:outsidejudge265 文档编号:729713 上传时间:2019-01-08 格式:PDF 页数:21 大小:111.35KB
下载 相关 举报
ETSI EN 301 489-7-2005 Electromagnetic compatibility and Radio spectrum Matters (ERM) ElectroMagnetic Compatibility (EMC) standard for radio equipment and services Part 7 Specific .pdf_第1页
第1页 / 共21页
ETSI EN 301 489-7-2005 Electromagnetic compatibility and Radio spectrum Matters (ERM) ElectroMagnetic Compatibility (EMC) standard for radio equipment and services Part 7 Specific .pdf_第2页
第2页 / 共21页
ETSI EN 301 489-7-2005 Electromagnetic compatibility and Radio spectrum Matters (ERM) ElectroMagnetic Compatibility (EMC) standard for radio equipment and services Part 7 Specific .pdf_第3页
第3页 / 共21页
ETSI EN 301 489-7-2005 Electromagnetic compatibility and Radio spectrum Matters (ERM) ElectroMagnetic Compatibility (EMC) standard for radio equipment and services Part 7 Specific .pdf_第4页
第4页 / 共21页
ETSI EN 301 489-7-2005 Electromagnetic compatibility and Radio spectrum Matters (ERM) ElectroMagnetic Compatibility (EMC) standard for radio equipment and services Part 7 Specific .pdf_第5页
第5页 / 共21页
点击查看更多>>
资源描述

1、 ETSI EN 301 489-7 V1.3.1 (2005-11)Candidate Harmonized European Standard (Telecommunications series) Electromagnetic compatibilityand Radio spectrum Matters (ERM);ElectroMagnetic Compatibility (EMC)standard for radio equipment and services;Part 7: Specific conditions for mobile and portable radioan

2、d ancillary equipment of digital cellular radiotelecommunications systems (GSM and DCS)ETSI ETSI EN 301 489-7 V1.3.1 (2005-11) 2 Reference REN/ERM-EMC-245-7 Keywords EMC, GSM, GSM_Phase1, GSM_Phase2, GSM_Phase2_Plus, radio, regulation ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRAN

3、CE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Important notice Individual copies of the present document can be downloaded from: http:/www.etsi.org The present document may be

4、 made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version

5、 kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at http:/portal.etsi.org/tb/status/status.asp If

6、you find errors in the present document, please send your comment to one of the following services: http:/portal.etsi.org/chaircor/ETSI_support.asp Copyright Notification No part may be reproduced except as authorized by written permission. The copyright and the foregoing restriction extend to repro

7、duction in all media. European Telecommunications Standards Institute 2005. All rights reserved. DECTTM, PLUGTESTSTM and UMTSTM are Trade Marks of ETSI registered for the benefit of its Members. TIPHONTMand the TIPHON logo are Trade Marks currently being registered by ETSI for the benefit of its Mem

8、bers. 3GPPTM is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. ETSI ETSI EN 301 489-7 V1.3.1 (2005-11) 3 Contents Intellectual Property Rights5 Foreword.5 1 Scope 6 2 References 6 3 Definitions and abbreviations.7 3.1 Definitions7 3.2 Abbrevia

9、tions .7 4 Test conditions .8 4.1 General .8 4.2 Arrangements for test signals .8 4.2.1 Arrangements for establishing a communications link.8 4.2.1.1 Calibration of the overall audio link performance 8 4.2.1.2 Measurement of the audio level at the speech output of the EUT.10 4.2.2 Arrangements for t

10、est signals at the input of transmitters.10 4.2.3 Arrangements for test signals at the output of transmitters.11 4.2.4 Arrangements for test signals at the input of receivers .11 4.2.5 Arrangements for test signals at the output of receivers .11 4.2.6 Idle mode 11 4.3 Exclusion bands11 4.3.1 Receive

11、r and receivers of duplex transceivers exclusion band .11 4.3.2 Transmitter exclusion band.12 4.4 Narrow band responses of receivers and receivers of duplex transceivers.12 4.5 Normal test modulation12 5 Performance assessment.12 5.1 General .12 5.2 Equipment which can provide a continuous communica

12、tions link 13 5.2.1 Equipment with analogue speech circuits.13 5.2.2 Equipment without analogue speech circuits13 5.3 Equipment which does not provide a continuous communications link.13 5.4 Ancillary equipment .13 5.5 Equipment classification 13 6 Performance criteria .13 6.1 Performance criteria f

13、or Continuous phenomena applied to Transmitters (CT) 14 6.2 Performance criteria for Transient phenomena applied to Transmitters (TT)14 6.3 Performance criteria for Continuous phenomena applied to Receivers (CR).14 6.4 Performance criteria for Transient phenomena applied to Receivers (TR) 15 6.5 Per

14、formance criteria for ancillary equipment tested on a stand alone basis .15 7 Applicability overview.15 7.1 Emission.15 7.1.1 General15 7.1.2 Special conditions.15 7.2 Immunity 15 7.2.1 General15 7.2.2 Special conditions.16 Annex A (informative): Examples of mobile and portable radio and ancillary e

15、quipment for digital cellular radio telecommunications systems within the scope of the present document.17 A.1 Mobile and portable radio equipment, and ancillary equipment meeting Phase 1, Phase 2, and Phase 2+ requirements of GSM 450 MHz, 900 MHz or DCS 1 800 MHz digital cellular telecommunications

16、 system17 ETSI ETSI EN 301 489-7 V1.3.1 (2005-11) 4 Annex B (informative): Bibliography.18 Annex C (informative): The EN title in the official languages .19 History 21 ETSI ETSI EN 301 489-7 V1.3.1 (2005-11) 5 Intellectual Property Rights IPRs essential or potentially essential to the present docume

17、nt may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of E

18、TSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/webapp.etsi.org/IPR/home.asp). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existen

19、ce of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This Candidate Harmonized European Standard (Telecommunications series) has been produced by ETSI Technical Committee Electromag

20、netic compatibility and Radio spectrum Matters (ERM). The present document has been produced by ETSI in response to a mandate from the European Commission issued under Council Directive 98/34/EC 9 (as amended) laying down a procedure for the provision of information in the field of technical standar

21、ds and regulations. The present document is intended to become a Harmonized Standard, the reference of which will be published in the Official Journal of the European Communities referencing the Council Directive on the approximation of the laws of the Member States relating to electromagnetic compa

22、tibility (“the EMC Directive“) (89/336/EEC 3 as amended) and Directive 1999/5/EC 2 of the European Parliament and of the Council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (“the R ElectroMagnetic Compatibility (EMC) sta

23、ndard for radio equipment and services; Part 1: Common technical requirements“. 2 Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (R Radio subsystem link cont

24、rol (GSM 05.08)“. 5 ETSI I-ETS 300 034-2: “European digital cellular telecommunications system (Phase 1); Radio subsystem link control; Part 2: DCS extension (GSM 05.08-DCS)“. ETSI ETSI EN 301 489-7 V1.3.1 (2005-11) 7 6 ETSI ETS 300 578: “Digital cellular telecommunications system (Phase 2) (GSM); R

25、adio subsystem link control (GSM 05.08)“. 7 ETSI TS 100 911: “Digital cellular telecommunications system (Phase 2+) (GSM); Radio subsystem link control (3GPP TS 05.08)“. 8 ITU-T Recommendation P.64: “Determination of sensitivity/frequency characteristics of local telephone systems“. 9 Directive 98/3

26、4/EC of the European Parliament and of the Council of 22 June 1998 laying down a procedure for the provision of information in the field of technical standards and regulations. 3 Definitions and abbreviations 3.1 Definitions For the purposes of the present document, the terms and definitions given i

27、n EN 301 489-1 1 and the following apply: idle mode: mode of operation of a receiver or a transceiver, where the Equipment Under Test (EUT) is powered, available for service and available to respond to a request to set up a call RXQUAL: measure of the received signal quality, which is generated by t

28、he mobile or portable equipment, for use as a criterion in the Radio Frequency (RF) power control and handover processes NOTE: For more information see: - I-ETS 300 034-1 4 clause 8.2 for Phase 1 GSM 900 equipment; - I-ETS 300 034-2 5 clause 8.2 for Phase 1 DCS 1800 equipment; or - ETS 300 578 6 cla

29、use 8.2 for Phase 2 GSM 900 or Phase 2 DCS 1800 equipment; - TS 100 911 7 clause 8.2 for Phase 2+ GSM 900 or Phase 2+ DCS 1800 equipment. 3.2 Abbreviations For the purposes of the present document, the following abbreviations apply: AC Alternating Current ARFCN Absolute Radio Frequency CHannel Numbe

30、r (see note) BCCH Broadcast Control Channel (see note) BS Base Station BSS Base Station System BTS Base Transceiver Station CCCH Common Control CHannel (see note) CR Continuous phenomena applied to Receivers (see clause 6.3) CT Continuous phenomena applied to Transmitters (see clause 6.1) DTX Discon

31、tinuous Transmission (see note) EMC ElectroMagnetic Compatibility EUT Equipment Under Test MRP Mouth Reference Point (artificial head) RF Radio Frequency RXQUAL Receiver QUALity (see note) SPL Sound Pressure Level TR Transient phenomena applied to Receivers (see clause 6.4) TT Transient phenomena ap

32、plied to Transmitters (see clause 6.2) NOTE: Refer to (GSM) functional radio standards for further details. ETSI ETSI EN 301 489-7 V1.3.1 (2005-11) 8 4 Test conditions For the purpose of the present document, the test conditions of EN 301 489-1 1, clause 4, shall apply as appropriate. Further produc

33、t related test conditions for digital cellular mobile and portable radio equipment are specified in the present document. 4.1 General For emission and immunity tests the test modulation, test arrangements, etc., as specified in the present document, clauses 4.1 to 4.5, shall apply. Whenever the Equi

34、pment Under Test (EUT) is provided with a detachable antenna, the EUT shall be tested with the antenna fitted in a manner typical of normal intended use, unless specified otherwise. 4.2 Arrangements for test signals The provisions of EN 301 489-1 1, clause 4.2 shall apply. 4.2.1 Arrangements for est

35、ablishing a communications link The nominal frequency of the wanted RF input signal (for the receivers) shall be selected by setting the Absolute Radio Frequency Channel Number (ARFCN) to an appropriate number (e.g. in case of GSM 900 MHz this is 60 to 65, and in case of GSM 1 800 MHz this is 690 to

36、 706). A communication link shall be set up with a suitable base station simulator (hereafter called “the test system“). When the EUT is required to be in the transmit/receive mode, the following conditions shall be met: - the EUT shall be commanded to operate at maximum transmit power; - the downli

37、nk RXQUAL shall be monitored. 4.2.1.1 Calibration of the overall audio link performance Prior to the test sequence, the reference level of the speech output signal on both the downlink and uplink shall be recorded on the test instrumentation, as shown in figure 1. If the equipment does not include a

38、coustical transducers (e.g. a microphone or loudspeaker) the equivalent electrical reference levels shall be specified by the manufacturer. The voice processor may often apply noise and echo cancellation algorithms which attempt to eliminate or reduce steady state audio signals as e.g. the 1 kHz cal

39、ibration signals. The calibration should be carried out with the noise and echo cancellation algorithms disabled. (Specific test software may be required). If the noise and echo cancellation algorithms cannot be disabled then the reference level of the speech output signal should be measured using a

40、 max-hold detection on the audio level meter in order to determine the level before the noise and echo cancellation algorithms become effective. ETSI ETSI EN 301 489-7 V1.3.1 (2005-11) 9 Calibration of the downlink: The EUT is not used for the calibration of the downlink. Adjust the output of the au

41、dio test source to achieve a reference level equivalent to a SPL of 0 dBPa at 1 kHz at the input of the acoustic coupler (tube in figure 1) for the downlink. Record the reading of the audio level meter as the reference level. If in handsfree applications an external loudspeaker is used, the SPL from

42、 the external loudspeaker is higher than that from the earpiece of the portable by a certain amount in order overcome a high ambient noise level. Two methods can be used to achieve the required SPL: - the downlink reference level shall be increased by the same amount in order to compensate for the d

43、ifference in SPL; or - the distance between the loudspeaker and the measuring microphone shall be adjusted during the measurement procedure resulting in the required SPL. It is important that the dynamic range of the test instrumentation is not exceeded. Calibration of the uplink: For the calibratio

44、n of the uplink the EUT is used. Adjust the output of the audio test source to achieve a reference level equivalent to a SPL of -5 dBPa at 1 kHz at the Mouth Reference Point (MRP) defined in ITU-T Recommendation P.64 8. Record the reading of the audio level meter, which is connected to the output of

45、 the test system, as the reference level. For handsfree applications, normally no corrections are made to the uplink reference level. If it is not possible to perform the above calibration (e.g. a PC card with headset) the manufacturer shall specify the distance between the MRP and the microphone. I

46、t is important that the dynamic range of the test instrumentation is not exceeded. NOTE: The MRP is defined with respect to an artificial head defined in ITU-T Recommendation P.64 8). The handset shall be mounted on the artificial head such that the ear piece is centred at the artificial ear. Both r

47、ecorded levels (downlink and uplink) are used as reference levels for the performance assessment (see clauses 6.1 and 6.3). Audio level meter Audio level meter Transducer BPF CF = 1 kHz BW = 200 Hz BPF CF = 1 kHz BW = 200 Hz Test system Radio link 1 kHz test source MRP -5 dBPa 0 dBPa EUT tube 1 kHz

48、test source NOTE: The EUT is in position during calibration of the uplink, but not during calibration of the downlink where the EUT is replaced by the 1 kHz test audio source. During calibration of the uplink the mouthpiece shall be placed with respect to the MRP in a way representing intended use.

49、Figure 1: Audio breakthrough measurement, calibration set-up for portable equipment ETSI ETSI EN 301 489-7 V1.3.1 (2005-11) 104.2.1.2 Measurement of the audio level at the speech output of the EUT The voice processor may apply noise and echo cancellation algorithms which attempt to eliminate or reduce steady state audio signals as e.g. the 1 kHz calibration signals. When the audio levels are measured during testing the EUT software shall be configured for voice applications. If the algorithms for noise and echo cancellation are not disabled, t