ETSI ES 200 671-2000 Transmission and Multiplexing (TM) Passive Optical Components Optical Fibre Connectors for Single Mode Optical Fibre Communication Systems Common Requirements .pdf

上传人:cleanass300 文档编号:730656 上传时间:2019-01-08 格式:PDF 页数:19 大小:920.73KB
下载 相关 举报
ETSI ES 200 671-2000 Transmission and Multiplexing (TM) Passive Optical Components Optical Fibre Connectors for Single Mode Optical Fibre Communication Systems Common Requirements .pdf_第1页
第1页 / 共19页
ETSI ES 200 671-2000 Transmission and Multiplexing (TM) Passive Optical Components Optical Fibre Connectors for Single Mode Optical Fibre Communication Systems Common Requirements .pdf_第2页
第2页 / 共19页
ETSI ES 200 671-2000 Transmission and Multiplexing (TM) Passive Optical Components Optical Fibre Connectors for Single Mode Optical Fibre Communication Systems Common Requirements .pdf_第3页
第3页 / 共19页
ETSI ES 200 671-2000 Transmission and Multiplexing (TM) Passive Optical Components Optical Fibre Connectors for Single Mode Optical Fibre Communication Systems Common Requirements .pdf_第4页
第4页 / 共19页
ETSI ES 200 671-2000 Transmission and Multiplexing (TM) Passive Optical Components Optical Fibre Connectors for Single Mode Optical Fibre Communication Systems Common Requirements .pdf_第5页
第5页 / 共19页
点击查看更多>>
资源描述

1、ETSI ES 200 671 1.2.1 (2000-08) ETSI Standard Transmission and Multiplexing (TM); Passive optical components; Optical fibre connectors for single mode optical fibre communication systems; Common requirements and conformance testing 2 ETSI ES 200 671 V1.2.1 (2000-08) The pre ent d Reference RES/TM-O1

2、053 Keywords Optical, transmission, connector, testing ETSI 650 Route des Lucioles F-O6921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 O0 Fax: +33 4 93 65 47 16 Siret No 348 623 562 0001 7 - NAF 742 C Association but non lucratif enregistre la Sous-prfecture de Grasse (06) No 7803/88 Import

3、ant notice Individual copies of the present document can be downloaded from: http:/w.etsi.aq cument mav be made available in more than one electronic version or in orint. In anv case f existing or perceived difference in coitents between such versions, the reference version is the Poiable Docuhent F

4、ormat (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on the curren

5、t status of this and other ETSI documents is available at ht?p:/.etsi.orn/lb/status/ If you find errors in the present document, send your comment to: editor et.si.fr Coovriaht Notification No part may be reproduced except as authorized by written permission. The copyright and the foregoing restrict

6、ion extend to reproduction in all media. O European Telecommunications Standards Institute 2000. All rights reserved. ETSI 3 ETSI ES 200 671 V1.2.1 (2000-08) Contents Intellectual Property Rights 4 Foreword 4 1 2 3 3.1 3.2 4 4.1 4.1.1 4.1.2 4.2 4.3 4.3.1 4.3.2 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12

7、4.13 4.14 4.15 4.16 4.17 4.18 4.19 4.20 4.21 Scope 5 References 5 Definition and abbreviations 6 Definition . 6 Abbreviations . 6 Details, measurements and performance requirements 6 Visual inspection 6 Overall inspection of connectors . 6 Inspection of the end face . 6 Dimensions and mechanical mea

8、surements accuracy . 6 Attenuation . 7 Attenuation against a reference connector 7 Attenuation of random mated connectors . 7 Return Loss (RL) of random mated connectors 7 Bending moment 8 Torsion . 9 Strength of coupling mechanism 9 Drop . 10 Static side load . 10 Vibration (sinusoidal) . 8 Cable p

9、ulling 9 Cold 10 Dry heat 11 Change of temperature 12 Mechanical endurance 12 Damp heat (cycling) . 13 Corrosive atmosphere (salt mist) 13 Dust 14 Condensation 14 Intermatibility . 15 Damp heat (steady state) . 11 4.21.1 Attenuation measurement 15 4.21.2 4.21.3 4.21.4 Mechanical endurance 15 4.21.5

10、Strength of coupling mechanism . 15 5 Acceptance criteria . 15 5.1 Minimum sample size for qualification 15 5.1.1 Qualification to minimum uniform requirements 15 5.1.2 Qualification for ETS 300 019 environment classes 3.3, 3.4, 3.5 and 4.1 16 5.1.3 Qualification of intermatibility of connectors fro

11、m different sources . 17 5.2 Padfail criteria 18 Return loss measurement 15 Change of temperature 15 History 19 ETSI 4 ETSI ES 200 671 V1.2.1 (2000-08) Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertain

12、ing to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR O00 3 14: “Intellectual Propero Rights (IPRs); Essential, or potentially Essential, IPRs notifed to ETSI in respect of ETSI standards“, which is available from the ETSI Secretaria

13、t. Latest updates are available on the ETSI Web server (htti,:/www.etsi.oxg/ii-). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR O00 314 (or the updates on

14、the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This ETSI Standard (ES) has been produced by ETSI Technical Committee Transmission and Multiplexing (TM). The present document is a revision of I-ETS 300 67 1 5. ETSI 5 ETSI ES 200 671 V1.2.1 (2000-

15、08) 1 Scope The present document specifies requirements of connector sets to be used in single-mode optical fibre telecommunication systems and it applies only to pigtailed connectors, not patchcords. The scope covers the establishment of minimum uniform requirements for the following aspects: - opt

16、ical, environmental and mechanical properties; - test conditions: - acceptance criteria. Reliability aspects of connector sets are not covered by the present document. Some users may have additional specific requirements, such as a need to verify performance at lower temperatures. These users should

17、 specify connectors conforming to the basic ETSI performance standard, plus additional tests or more severe test conditions. Connectors for different applications which fall within the scope of the present document have common environmental and mechanical stability requirements, but there are two gr

18、ades of attenuation requirement and three grades of return loss. The attenuation grades are designated P and Q. The return loss grades are designated T, U and V. Test methods are in accordance with IEC 61300 series 2. For a definition of a connector set, see subclause 3.1 of the present document. 2

19、References The following documents contain provisions which, through reference in this text, constitute provisions of the present document. References are either specific (identified by date of publication, edition number, version number, etc.) or non-specific. For a specific reference, subsequent r

20、evisions do not apply. For a non-specific reference, the latest version applies. A non-specific reference to an ETS shall also be taken to refer to later versions published as an EN with the same number. il IEC 60874-1 (including Amendment 1): “Connectors for optical fibres and cables - Part 1: Gene

21、ric specification“. IEC 6 1300-X-X (XX = different sub-parts): “Fibre optic interconnecting devices and passive components - Basic test and measurement procedures“. ETSI ETS 300 O 19: “Equipment Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment“. IEC

22、 60068-2-30: “Environmental testing - Part 2: Tests. Test Db and guidance: Damp heat, cyclic (12 + 12-hour cycle)“. ETSI I-ETS 300 67 1: “Transmission and Multiplexing (TM); Passive optical components; Fibre optical connectors for single-mode optical fibre communication systems; Common requirements

23、and conformance testing“. Pl 31 41 51 ETSI 6 ETSI ES 200 671 V1.2.1 (2000-08) 3 Definition and abbreviations 3.1 Definition For the purposes of the present document, the following definition applies: connector set: complete set of connector components required to provide demountable coupling between

24、 one or more pairs of optical fibres 3.2 Abbreviations For the purposes of the present document, the following abbreviations apply: OTDR Optical Time Domain Reflectometer RL Return Loss 4 Details, measurements and performance req ui rements All measurements shall be carried out under normal room con

25、ditions, unless otherwise stated. Before the insertion and return loss measurement, careful cleaning in accordance with manufacturers instructions is necessary. All optical tests shall be carried out in both the 1310 nm window and the 1550 nm window unless otherwise stated. Light sources with peak w

26、avelengths of 1 3 10 * 30 nm and 1 550 * 30 nm shall be used. The length of fibre or cable on each side of the connector set shall be 1,5 m (minimum). A minimum length of 1,5 m on each side of the test set shall be exposed to the test conditions of all climatic and environmental tests. 4.1 Visual in

27、spection 4.1 .l Overall inspection of connectors Each connector shall be properly packed. The package shall be marked with the name of the manufacturer and the production date. The connector itself shall be legibly and durably marked with the identity mark of the manufacturer and the manufacturing d

28、ate code. 4.1.2 Inspection of the end face The end face shall be clean and free from residues of glue. No scratches or break out of glass pieces shall be seen when using a microscope with a maximum magnification of 200 times. 4.2 Dimensions and mechanical measurements accuracy Measurement accuracy a

29、nd standardization shall be established to ensure consistency of production and consistency of performance of inter-mated connectors from different sources. Mechanical measurement accuracy shall be demonstrated to be in accordance with IEC 60874-1 i amendment 1. ETSI 7 Attenuation ETSI ES 200 671 V1

30、.2.1 (2000-08) 4.3.1 Attenuation against a reference connector Details: In accordance with IEC 61300-3-4 2, method 7 (measurements against a reference plug). Reference plug: Type A): For qualification testing to determine the loss of connector sets when one side is a defined reference, the eccentric

31、ity of the reference connector plug (centre of fibre core to centre of ferrule) shall be 5 0,3 pm. The reference plug shall in all other respects conform to the same detail or product specification as the connector under test. For environmental, mechanical and climatic testing detailed in the presen

32、t document, the reference plug shall be selected randomly from the regular production of the connector sets that are undergoing qualification testing. For these tests, the initial loss of the connector sets that are to be tested shall be less than 1,O dl3 for plugs conforming to grade P or less than

33、 0,60 dl3 for plugs conforming to grade Q. Type B): Only the fundamental mode shall propagate at the connector interface and at the detector. Requirements: Attenuation: 5 0,50 dl3 when mated to reference plug Type A. (This is the maximum for any mating). 4.3.2 Attenuation of random mated connectors

34、Details: In accordance with IEC 61300-3-34 2. Only the fundamental mode shall propagate at the connector interface and at the detector. Statistical attenuation requirements: attenuation grade P: Mean 5 0,35 dl3; 1,0 dl3 maximum for 2 97 % of mating combinations. attenuation grade Q: Mean 5 0,30 dl3;

35、 0,60 dl3 maximum for 2 99 % of mating combinations. 4.4 Return Loss (RL) of random mated connectors Details: In accordance with IEC 61300-3-6 method 2 (coupler method) 2: launch fibre length (L): 2m 5 L 5 4 m; source stability: better than I0,20 dl3 over the measurement period. Alternatively, the r

36、eturn loss may be measured using an Optical Time Domain Reflectometer (OTDR) in accordance with IEC 61300-3-6 2 method 2. It is recommended to calibrate OTDR against coupler based measurements or reference reflector. Reference connector: the reference connector shall conform to the same detail or pr

37、oduct specification as the connector under test. ETSI 8 ETSI ES 200 671 V1.2.1 (2000-08) Requirements: RL (minimum return loss for every mating): RL grade T: 2 35 dl3 for low reflection connectors (as measured when mated); RL grade U: 2 45 dl3 for ultra low reflection connectors (as measured when ma

38、ted); RL grade V: 2 55 dl3 for ultra low reflection connectors (as measured when mated and unmated). Vi bration (sinusoidal) Details: In accordance with IEC 61300-2-1 2: frequency range: endurance duration per axis: number of axes: three, orthogonal; 10 Hz to 55 Hz; 0,5 hour; number of cycles (10-55

39、-10): 15; vibration amplitude: 0,75 mm. Requirements: allowable attenuation variation: 5 0,20 dl3, measured at 1 550 * 30 nm; allowable return loss variation: The attenuation shall be measured at 1 550 * 30 nm before, during and after the test as specified in subclause 4.3.1. The sampling interval d

40、uring the test shall be 2 ms. The return loss shall be measured as specified in subclause 4.4 before, during and after the test, at 1 550 * 30 nm. The sampling interval during the test shall be 2 ms. return loss shall not fall below the minimum for the grade. 4.6 Bending moment In accordance with IE

41、C 61300-2-7 2. Details: severity: duration: 120 s. Requirements: allowable attenuation variation: 5 0,20 dl3, measured at 1 550 * 30 nm; 10 N smoothly applied 25 mm from the centre line defined by the optical interface. allowable return loss variation: return loss shall not fall below the minimum fo

42、r the grade. The attenuation shall be measured at 1 550 * 30 nm before, during and after the test as specified in subclause 4.3.1. During the test the attenuation shall be measured at least once while the load is at the maximum level. The return loss shall be measured as specified in subclause 4.4 b

43、efore, during and after the test, at 1550 * 30 nm. During the test the return loss shall be measured at least once while the load is at the maximum level. ETSI 9 ETSI ES 200 671 V1.2.1 (2000-08) 4.7 Cable pulling Details: In accordance with IEC 61300-2-4 2: magnitude and rate of application of the t

44、ensile load: 100 * 5 N applied at 5 N/s for reinforced cables; 5 I0,5 N applied at 0,5 N/s for coated fibres. 120 s for reinforced cables; 60 s for coated fibres. duration of the test (maintaining the load): point of application of the tensile load: 0,3 m from the end-face of the connector. Requirem

45、ents: allowable attenuation variation: allowable return loss variation: The attenuation shall be measured at 1 550 * 30 nm before, during and after the test as specified in subclause 4.3.1. During the test the attenuation shall be measured at least once while the load is at the maximum level. The re

46、turn loss shall be measured as specified in subclause 4.4 before, during and after the test, at 1550 * 30 nm. During the test the return loss shall be measured at least once while the load is at the maximum level. 5 0,20 dl3, measured at 1 550 * 30 nm; return loss shall not fall below the minimum fo

47、r the grade. Torsi on Details: In accordance with IEC 61300-2-5 2: magnitude of the tensile load 15 N for reinforced cable; 2 N for coated fibre. 0,2 m from the end face of the connector; 25 cycles (not to exceed the cable specification). point of application of the tensile load: duration of the tes

48、t: Requirements: allowable attenuation variation: The attenuation shall be measured at 1 550 * 30 nm before and after the test as specified in subclause 4.3.1. 5 0,20 dl3, measured at 1 550 * 30 nm. 4.9 Strength of coupling mechanism In accordance with IEC 61300-2-6 2. Details: magnitude of the tens

49、ile load: rate of application of the load: point of application of the load: duration of the test (maintaining the load): Requirements: allowable attenuation variation: allowable return loss variation: 40 N; 2 N/s; 0,3 m from the end face of the connector; 120 s. 5 0,20 dl3, measured at 1 550 * 30 nm; return loss shall not fall below the minimum for the grade. ETSI 10 ETSI ES 200 671 V1.2.1 (2000-08) The attenuation shall be measured at 1 550 * 30 nm before, during and after the test as specified in subclause 4.3.1. During the test the attenuation shal