ETSI TS 101 761-4-2002 Broadband Radio Access Networks (BRAN) HIPERLAN Type 2 Data Link Control (DLC) Layer Part 4 Extension for Home Environment (V1 3 2)《宽带无线接入网(BRAN) HIPERLAN第2类_1.pdf

上传人:twoload295 文档编号:738293 上传时间:2019-01-12 格式:PDF 页数:120 大小:6.21MB
下载 相关 举报
ETSI TS 101 761-4-2002 Broadband Radio Access Networks (BRAN) HIPERLAN Type 2 Data Link Control (DLC) Layer Part 4 Extension for Home Environment (V1 3 2)《宽带无线接入网(BRAN) HIPERLAN第2类_1.pdf_第1页
第1页 / 共120页
ETSI TS 101 761-4-2002 Broadband Radio Access Networks (BRAN) HIPERLAN Type 2 Data Link Control (DLC) Layer Part 4 Extension for Home Environment (V1 3 2)《宽带无线接入网(BRAN) HIPERLAN第2类_1.pdf_第2页
第2页 / 共120页
ETSI TS 101 761-4-2002 Broadband Radio Access Networks (BRAN) HIPERLAN Type 2 Data Link Control (DLC) Layer Part 4 Extension for Home Environment (V1 3 2)《宽带无线接入网(BRAN) HIPERLAN第2类_1.pdf_第3页
第3页 / 共120页
ETSI TS 101 761-4-2002 Broadband Radio Access Networks (BRAN) HIPERLAN Type 2 Data Link Control (DLC) Layer Part 4 Extension for Home Environment (V1 3 2)《宽带无线接入网(BRAN) HIPERLAN第2类_1.pdf_第4页
第4页 / 共120页
ETSI TS 101 761-4-2002 Broadband Radio Access Networks (BRAN) HIPERLAN Type 2 Data Link Control (DLC) Layer Part 4 Extension for Home Environment (V1 3 2)《宽带无线接入网(BRAN) HIPERLAN第2类_1.pdf_第5页
第5页 / 共120页
点击查看更多>>
资源描述

1、ETSI TS 1 O 1 761 -4 VI .3.2 (2002-01) Technical Specification Broadband Radio Access Networks (BRAN); HIPERLAN Type 2; Data Link Control (DLC) Layer; Part 4: Extension for Home Environment 2 ETSI TS 101 761-4 V1.3.2 (2002-01) Reference RTSIBRAN-0020004-4R3 Keywords access, broadband, HIPERLAN, IP,

2、layer 2, MAC, radio ETSI 650 Route des Lucioles F-O6921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 O0 Fax: +33 4 93 65 47 16 Siret No 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-prfecture de Grasse (06) No 7803/88 Important notice Individual copies of the

3、present document can be downloaded from: http:l/w.etsi .orq The present document may be made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF). In c

4、ase of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on the current status of this

5、and other ETSI documents is available at 3 If you find errors in the present document, send your comment to: Cori vriaht Notifica tion No part may be reproduced except as authorized by written permission. The copyright and the foregoing restriction extend to reproduction in all media. O European Tel

6、ecommunications Standards Institute 2002. All rights reserved. ETSI 3 ETSI TS 101 761-4 VI .3.2 (2002-01) Contents Intellectual Property Rights . .6 Foreword . 6 Introduction . .6 1 Scope 7 2 References . .7 3 Definitions, symbols and abbreviations . 7 . . 7 3.1 Definitions . Symbols . . 10 3.2 . Ab

7、breviations . . 10 3.3 4 Overview 11 H/2 home network architecture 4.1.1 The single subnet model . 4.1.2 The multiple subnets model . . 12 4.2 Service types to be supported. . . 12 4.3 Types of devices supported . . 13 11 11 4.1 5 DM transmission and reception functions (OCC/OWT) . . 14 5.1 5.2 5.3

8、5.4 5.5 5.6 5.6.1 5.6.2 5.6.3 5.6.4 5.6.5 5.7 5.8 5.8.1 5.8.2 5.8.2.1 5.8.2.2 5.8.2.3 5.8.2.4 5.8.2.5 5.8.3 5.8.4 5.8.4.1 5.8.4.2 5.8.4.3 5.8.4.4 5.8.4.5 5.8.4.6 5.8.4.7 5.9 5.10 Logical channels and their characteristics Transport channels aiid their characteristics . Mapping between logical and tr

9、ansport channels . Mapping between MAC frame and PHY frame . DLC addressing for Home Environment Use of DiL logical channels Overview of the MAC frame . Resource request and resource grant for MAC protocol for DM EC protocol for DM Error Control (EC) protocol for the ac Handling of Dynamic ARQ band

10、Setting of the ARB in the RR for DiL Transmitter actions in case of ins Receiver actions in case of insufficient ARQ feedback resources (in Scheduling of suffici . 20 . 21 . 21 . 21 Principles . . . 21 UDCH message format . . .22 RS word generation . . Dummy LCH PDU ge . 23 .24 Interleaver and deint

11、erle . Interle aveddeinterle aver .24 Connection termination., . 25 Broadcast transmission . . 25 Encryption . . .25 .20 EC protocol for the repeti EC protocol for the FEC . 6 6.1 General (informative) . 6.1.1 Basic RLC functions applied 6.1.1.1 DLC User Connection Control 6.1.1.2 Radio Resource Con

12、trol Services supported by the Radio Link Control sublayer 27 27 27 28 28 ETSI 4 ETSI TS 101 761-4 V1.3.2 (2002-01) 6.1.2 6.1.2.1 6.1.2.2 6.1.3 6.1.3.1 6.1.3.2 6.1.4 6.2 6.3 6.4 6.4.1 6.4.1.1 6.4.1.2 6.4.2 6.5 6.5.1 6.5.2 6.5.2.1 6.5.2.2 6.5.3 6.5.3.1 6.5.3.2 6.5.4 6.6 6.6.1 6.6.1.1 6.6.1.2 6.6.1.3

13、6.6.2 6.6.2.1 6.6.2.2 6.6.2.3 6.6.2.4 6.6.2.5 6.6.2.6 6.7 6.7.1 6.7.2 6.7.3 6.7.3.1 6.7.3.2 6.7.3.3 6.7.4 6.7.4.1 6.8 6.8.1 6.8.2 6.8.2.1 6.8.2.2 6.8.3 6.9 6.9.1 6.9.2 Changed RLC functions 28 Association Control Function 28 Radio Resource Control 28 RLC messages, parameter settings . 29 Association

14、 Control Function 29 DLC User Connection Control 29 New RLC functionality . 29 Terminal association for multiple convergence layers (OCC/OWT) . 30 Link adaptation in Direct Link phase (OCC/OWT) . 30 Power control in Direct Link phase (OCC/OWT) 30 Direct Link unicast power control 31 Connectivity che

15、ck 31 34 35 36 Principles of calibration 36 Direct Link multicasthroadcast power contr Measurement phase 37 Calibration-measurement trigger 37 Link quality calibration for DM operation (OCC Calibration measurement 38 38 39 39 41 DLC User Connection Control . 43 Fixed Slot Allocation for DM (OCC/OWT)

16、 . 43 CC operation . 44 WT operation 44 Timing of FSA 44 Multicast m DiL phase 46 General 46 DiL MULTICAST SETUP, WT-initiated (OCC/OWT) . 47 DiL multicast setup for a new joining WT (OCC/OWT) 52 DiL multicast setup, CC initiated (OCC/OWT) 52 Mod multicast (OCC/OWT) . 53 Release multicast (OCC/OWT)

17、. 55 Dynamic CC selection (MCC) . 57 Principle 57 Initial scanning process . 57 Definitions 58 Probing phase 58 Frequency scan phase 59 Parameter, Timer . 59 Protocol . 60 Frequency scanning . 61 CC Responsibility Handover (OCC/OWT) 61 Basic procedure 62 RLC Data transmitted during CC Responsibility

18、 Handover . 66 Parameters related to all associated H/2-HDs . 67 Parameters related to all maintained DiL connections 68 Data transfer procedure . 69 Authentication key management (OCC/OWT) 69 Installation of the first device in the network 70 Installation of a new device in the network 70 7 RLC Pro

19、tocol Data Units . 74 7.1 General . 74 7.2 Terminal association for multiple convergence layers . 74 Link adaptation in Direct Link phase . 74 7.3 7.4 Power Control m Direct Link phase . 74 7.5 Link quality calibration for DM operation . 75 7.6 DLC User Connection Control . 79 7.6.1 Fixed Slot Alloc

20、ation for DM . 79 ETSI 5 ETSI TS 101 761-4 V1.3.2 (2002-01) 7.6.2 7.6.2.1 7.6.2.2 7.6.2.3 7.6.2.4 7.6.2.5 7.6.2.6 7.6.2.7 7.6.2.8 7.6.2.9 7.6.2.10 7.7 7.8 7.8.1 7.8.2 7.9 Multicast m DiL phase 80 RLC-DM-MC-SETUP encoding . 80 RLC-DM-MC-CONNECT encoding 81 RLC-DM-MC-CONNECT-ACK encoding 82 RLC-DM-MC-

21、CONNECT-COMPLETE encoding 82 RLC-DM-MC-CONNECT-COMPLETE-ACK encoding 82 RLC-DM-MC-MODIFY-REQ encoding 83 RLC-DM-MC-MODIFY encoding . 84 RLC-DM-MC-MODIFY-ACK encoding . 85 RLC-DM-MC-RELEASE encoding . 85 RLC-DM-MC-RELEASE-ACK encoding 85 Dynamic CC Selection 86 CC Responsibility Han 87 87 89 Authenti

22、cation key management 91 Encoding of CC Database Parameters for CC Handover Transfer syntax tables of CC handover PDUs 8 Service primitives (informative) 92 8.1 Primitive types 92 8.2 Common DLC C-SAP primitives to Convergence Layer 93 8.3 Special DLC-C SAP primitives to 1394 Convergence Layer . 94

23、Annex A (normative): PDU types . 95 Annex B (normative): Parameter types . 96 . Annex C (normative): RLC timers . 98 Annex D (informative): Annex E (informative): Annex F (informative): Informative SDL FSMs concerning Power Control . 99 SDL FSMs concerning calibration . 101 Specification of the CC p

24、robing process in SDL . 104 Annex G (informative): Annex H (informative): Specification of the CC responsibility handover process in SDL 109 Example of valid Reed-Solomon word . 117 Annex I (informative): Bibliography . 119 History 120 ETSI 6 ETSI TS 101 761-4 V1.3.2 (2002-01) Intellectual Property

25、Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR O00 314: “Intellectual Property Rights (7PRs); Essent

26、ial, orpotentially Essential, IPRs notlJied to ETSI in respect ofETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (5). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarant

27、ee can be given as to the existence of other IPRs not referenced in ETSI SR O00 3 14 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This Technical Specification (TS) has been produced by ETSI Project Broadband Radio Access Net

28、works (BRAN). The present document describes the extension of the basic specifications of Data Link Control (DLC) of HIPERLAN/2 systems for home applications. Separate ETSI documents provide details on the system overview, the physical layer, the basic DLC layer functions, the convergence sublayers

29、and the conformance test requirements defiied for HIPERLAN/2. The present document is part 4 of a multi-part deliverable covering the Broadband Radio Access Networks (BRAN); HIPERLAN Type 2; Data Link Control (DLC) Layer, as identified below: Part 1 : Part 2: Part 3 : “Basic Data Transport Functions

30、“; “Radio Link Control (RLC) sublayer“; “Profile for Business Environment“; Part 4: “Extension for Home Environment“; Part 5: “Profile for Home Environment“ I n t rod uct ion The H/2 system is confined to the two lowest layers of the open systems interconnection (OSI) model, the physical (PHY) and t

31、he Data Link Control (DLC) layer. An overall description of the HIPERLAN/2 system is given in TR 101 683 (see bibliography). The PHY layer is described in TS 101 475 3. The basic DLC layer functions are specified in two different documents (TS 101 761-1 i and TS 101 761-2 2). Document TS 101 761-1 i

32、 describes Transport and Logical Channels, Error Control, MAC, and mapping between PHY and MAC of H/2 system. Document TS 101 761-2 2 deals with Radio Link Control (RLC) protocols to control radio resources, terminal association and connection establishment. The inter-working with higher layers is h

33、andled by Convergence Layers (CLs) on top of the DLC layer. The common part of packet and cell based convergence layers are defiied in TS 101 493-1 and TS 101 763-1 (see bibliography), respectively. ETSI 7 ETSI TS 101 761-4 V1.3.2 (2002-01) 1 Scope The present document specifies the extension of the

34、 basic DLC layer functions in TS 101 761-1 i and TS 101 761-2 2 for direct mode operation in home environment. This DLC home extension specification gives first an overview of the HIPERLAN/2 home system concept. It then describes additional rules and elements to transport DM data over the channels i

35、ntroduced in TS 101 761-1 i. Forward Error Correction (FEC) is introduced in the DLC layer to achieve a much lower bit error rate for isochronous packet transport without ARQ. The present document also extends the RLC protocols in TS 101 761-2 2 to support Constant Bit Rate (CBR) traffic by fixed sl

36、ot allocation, to enable parameter negotiation for multicast connections, to enable association of multiple CLs for wireless terminals, and to enable Direct Link (DiL) Power Control. Furthermore, It describes some RLC protocols which are only specific for DM operation in home environment, such as Di

37、L Link Quality Calibration, Dynamic CC Selection, and CC Responsibility Handover. Besides, a PIN and time-window based authentication key distribution protocol is specified for HIPERLAN/2 Home Devices (H/2-HDs). The DM services can be used by the IEEE 1394 CL (TS 101 493-3 and TS 101 493-4 (see bibl

38、iography) for wireless bridging of different IEEE 1394 buses. The present document does not contain algorithms, which are only performed locally in a device, but describes rules and elements to transport data over the air interface. The goal is to provide interoperability between devices of differen

39、t manufacturers. The present document does not address the requirements and technical characteristics for conformance testing. These are covered in a separate set of documents. 2 Re fe re nces The following documents contain provisions which, through reference in this text, constitute provisions of

40、the present document. References are either specific (identified by date of publication andor edition number or version number) or non-specific. For a specific reference, subsequent revisions do not apply. For a non-specific reference, the latest version applies. il ETSI TS 101 761-1: “Broadband Rad

41、io Access Networks (BRAN); HIPERLAN Type 2; Data Link Control (DLC) Layer; Part 1 : Basic Data Transport Functions“. ETSI TS 101 761-2: “Broadband Radio Access Networks (BRAN); HIPERLAN Type 2; Data Link Control (DLC) Layer; Part 2: Radio Link Control (RLC) sublayer“. ETSI TS 101 475: “Broadband Rad

42、io Access Networks (BRAN); HIPERLAN Type 2; Physical (PHY) Layer“. 21 31 3 3.1 Definitions, symbols and abbreviations De fi nit ions For the purposes of the present document, the following terms and definitions apply: Access feedback CHannel: transport channel where the results of access attempts ma

43、de in the random access phase of the previous MAC frame is conveyed Association Control Function: group of control functions on top of the RLC that is responsible for the handling of the association between WT and CC Association control CHannel: logical channel in uplink that conveys new association

44、 and re-association request messages ETSI 8 ETSI TS 101 761-4 V1.3.2 (2002-01) Access Point: term Access Point used in the basic specifications is replaced by the term Central Controller throughout TS 101 761-4 (V1.3.2) to reflect that in home environment multiple H/2 devices can act as the access p

45、oint to a fixed network, whereas the whole H/2 network is still controlled by a single entity, the Central Controller Basic WT: H/2 home device, which is able to associate with a CC and to communicate with the CC in the control plane and with other H/2 home devices in the user and control planes. A

46、basic WT is unable to become the CC. Broadcast CHannel: transport channel that broadcasts control information Broadcast Control CHannel: logical channel that broadcasts control information which is relevant for the current MAC frame CC-capable WT: H/2 home device, which can act either as a Central C

47、ontroller, or as a basic WT. When it is acting as the CC with respect to the control plane, it supports all features of a basic WT. Central Controller: provides control functionality equivalent to that of an access point in TS 101 761-1 and TS 101 761-2 but is not necessarily attached to a fixed net

48、work. This term is used where the central controller functionality is embedded in a WT. Centralized Mode: in centralized mode, all data transmitted or received by a mobile terminal have to pass the centralized controller, even if the data exchange is between mobile terminals associated to the same c

49、entralized controller DLC Connection: HIPERLAN/2 DLC operation is connection oriented. A DLC connection carries user or control data and is identified by a DLC connection identifier. DLC User Connection: DLC user connection is uniquely identified by the DLC connection ID and the MAC ID of the mobile terminal in CM. In DM two MAC IDS are necessary DLC User Connection Control: group of control functions on top of the RLC that is responsible for the handling of DLC user connections Downlink phase: part of the Downlink transmission of a MAC Frame during which user a

展开阅读全文
相关资源
猜你喜欢
  • AS NZS 3122-2005 Approval and test specification - Socket-outlet adaptors《试验规格与批准-电源插座转接器》.pdf AS NZS 3122-2005 Approval and test specification - Socket-outlet adaptors《试验规格与批准-电源插座转接器》.pdf
  • AS NZS 3200 2 38-1997 Approval and test specification - Medical electrical equipment - Particular requirements for safety - Electrically operated hospital beds《试验规格与批准-医用电气设备-安全性详细.pdf AS NZS 3200 2 38-1997 Approval and test specification - Medical electrical equipment - Particular requirements for safety - Electrically operated hospital beds《试验规格与批准-医用电气设备-安全性详细.pdf
  • AS NZS 3350 2 12-1997 Safety of household and similar electrical appliances - Particular requirements - Warming plates and similar appliances《家用及类似电器的安全性 - 详细要求 - 保温板及类似设备》.pdf AS NZS 3350 2 12-1997 Safety of household and similar electrical appliances - Particular requirements - Warming plates and similar appliances《家用及类似电器的安全性 - 详细要求 - 保温板及类似设备》.pdf
  • AS NZS 3350 2 13-2001 Safety of household and similar electrical appliances - Particular requirements for deep fat fryers frying pans and similar appliances (IEC 60335-2-13 1993 MO.pdf AS NZS 3350 2 13-2001 Safety of household and similar electrical appliances - Particular requirements for deep fat fryers frying pans and similar appliances (IEC 60335-2-13 1993 MO.pdf
  • AS NZS 3350 2 24-2001 Safety of household and similar electrical appliances - Particular requirements for refrigerating appliances and ice-cream appliances and ice-makers (IEC 6033.pdf AS NZS 3350 2 24-2001 Safety of household and similar electrical appliances - Particular requirements for refrigerating appliances and ice-cream appliances and ice-makers (IEC 6033.pdf
  • AS NZS 3350 2 29-2001 Safety of household and similar electrical appliances - Particular requirements for battery chargers (IEC 60335-2-29 1994 MOD)《给水用1 2 In (12 mm)到2 In (50 mm)聚.pdf AS NZS 3350 2 29-2001 Safety of household and similar electrical appliances - Particular requirements for battery chargers (IEC 60335-2-29 1994 MOD)《给水用1 2 In (12 mm)到2 In (50 mm)聚.pdf
  • AS NZS 3350 2 30-1997 Safety of household and similar electrical appliances - Particular requirements - Room heaters《家用与类似用途电器安全性 - 详细要求 - 室内加热器》.pdf AS NZS 3350 2 30-1997 Safety of household and similar electrical appliances - Particular requirements - Room heaters《家用与类似用途电器安全性 - 详细要求 - 室内加热器》.pdf
  • AS NZS 3350 2 32-2001 Safety of household and similar electrical appliances - Particular requirements for massage appliances (IEC 60335-2-32 1993 MOD)《给水用1 2 In (12 mm)到2 In (50 mm.pdf AS NZS 3350 2 32-2001 Safety of household and similar electrical appliances - Particular requirements for massage appliances (IEC 60335-2-32 1993 MOD)《给水用1 2 In (12 mm)到2 In (50 mm.pdf
  • AS NZS 3350 2 34-2001 Safety of household and similar electrical appliances - Particular requirements - Motor-compressors《家用和类似用途电器的安全性 电动压缩机的特殊要求》.pdf AS NZS 3350 2 34-2001 Safety of household and similar electrical appliances - Particular requirements - Motor-compressors《家用和类似用途电器的安全性 电动压缩机的特殊要求》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1