1、 ETSI TS 101 823-5-1 V1.3.1 (2004-08)Technical Specification Broadband Radio Access Networks (BRAN);HIPERLAN Type 2;Conformance testing for the Data Link Control (DLC) layer;Part 5: Profile for Home Environment;Sub-part 1: Profile Requirement List proforma specificationETSI ETSI TS 101 823-5-1 V1.3.
2、1 (2004-08) 2 Reference RTS/BRAN-002T0B4-5-1 Keywords access, HIPERLAN, PICS, testing ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de
3、Grasse (06) N 7803/88 Important notice Individual copies of the present document can be downloaded from: http:/www.etsi.org The present document may be made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between such versions, t
4、he reference version is the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision
5、 or change of status. Information on the current status of this and other ETSI documents is available at http:/portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following services: http:/portal.etsi.org/chaircor/ETSI_support.asp C
6、opyright Notification No part may be reproduced except as authorized by written permission. The copyright and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2004. All rights reserved. DECTTM, PLUGTESTSTM and UMTSTM are Trade Marks of ET
7、SI registered for the benefit of its Members. TIPHONTMand the TIPHON logo are Trade Marks currently being registered by ETSI for the benefit of its Members. 3GPPTM is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. ETSI ETSI TS 101 823-5-1 V1.3
8、.1 (2004-08) 3 Contents Intellectual Property Rights4 Foreword.4 Introduction 4 1 Scope 5 2 References 5 3 Definitions and abbreviations.6 3.1 Definitions6 3.2 Abbreviations .6 4 Conformance to this PRL proforma specification7 Annex A (normative): Profile requirement list for HOME profile using TS 1
9、01 493-3 specification as convergence sub layer.8 A.1 Purpose and structure .8 A.2 Impact on PICS proforma for DLC layer (CC and WT implementations) 8 A.2.1 Basic Data Transport8 A.2.1 DLC extensions 8 A.3 Impact on PICS proforma for Radio Link Control (RLC) protocol.9 A.3.1 WT implementation9 A.3.1
10、.1 Broadcast and multicast function9 A.3.1.2 Association Control Function (ACF)9 A.3.1.3 Radio Resource Control functions (RRC) 10 A.3.1.4 PDUs.11 A.3.2 CC implementation.11 A.3.2.1 Broadcast and multicast function11 A.3.2.2 Association Control Function (ACF)12 A.3.2.3 Radio Resource Control functio
11、ns (RRC) 12 A.3.2.4 PDUs.13 A.3.3 PDUs 13 A.4 Impact on PICS proforma for Packet based convergence layer - common part.14 A.5 Impact on PICS proforma for Wireless IEEE 1394 Applications14 Annex B (informative): Bibliography.15 History 16 ETSI ETSI TS 101 823-5-1 V1.3.1 (2004-08) 4 Intellectual Prope
12、rty Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Es
13、sential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/webapp.etsi.org/IPR/home.asp). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, h
14、as been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This Technical Specification (TS) has been produced by ETSI P
15、roject Broadband Radio Access Networks (BRAN). The present document is part 5, sub-part 1 of a multi-part deliverable. Full details of the entire series can be found in part 1, sub-part 1 5. Introduction To evaluate conformance of a particular implementation, it is necessary to have a statement of w
16、hich capabilities and options have been implemented for a telecommunication specification. When such a statement is based on a profile, it is called Profile ICS. ETSI ETSI TS 101 823-5-1 V1.3.1 (2004-08) 5 1 Scope The present document provides the Profile Requirement List (PRL) proforma for BRAN HIP
17、ERLAN type 2 DLC layer, Profile for Home Environment as defined in TS 101 761-51 in compliance with the relevant requirements, and in accordance with the relevant guidance given in ISO/IEC 9646-7 4 and ETS 300 406 2. It details in tabular form the implementation options, which come as modifications
18、to the PICS proforma of the protocols which constitute the Home profile. 2 References The following documents contain provisions which, through reference in this text, constitute provisions of the present document. References are either specific (identified by date of publication and/or edition numb
19、er or version number) or non-specific. For a specific reference, subsequent revisions do not apply. For a non-specific reference, the latest version applies. Referenced documents which are not found to be publicly available in the expected location might be found at http:/docbox.etsi.org/Reference.
20、1 ETSI TS 101 761-5 (V1.2.1): “Broadband Radio Access Networks (BRAN); HIPERLAN Type 2; Data Link Control (DLC) Layer; Part 5: Profile for Home Environment“. 2 ETSI ETS 300 406 (1995): “Methods for testing and Specification (MTS); Protocol and profile conformance testing specifications; Standardizat
21、ion methodology“. 3 ISO/IEC 9646-1: “Information technology - Open Systems Interconnection - Conformance testing methodology and framework - Part 1: General concepts“. 4 ISO/IEC 9646-7: “Information technology - Open Systems Interconnection - Conformance testing methodology and framework - Part 7: I
22、mplementation Conformance Statements“. 5 ETSI TS 101 823-1-1: “Broadband Radio Access Networks (BRAN); HIPERLAN Type 2; Conformance testing for the Data Link Control (DLC) layer; Part 1: Basic data transport functions; Sub-part 1: Protocol Implementation Conformance Statement (PICS) proforma“. 6 ETS
23、I TS 101 823-2-1: “Broadband Radio Access Networks (BRAN); HIPERLAN Type 2; Conformance testing for the Data Link Control (DLC) layer; Part 2: Radio Link Control (RLC) sublayer; Sub-part 1: Protocol Implementation Conformance Statement (PICS) proforma“. 7 ETSI TS 101 823-4-1: “Broadband Radio Access
24、 Networks (BRAN); HIPERLAN Type 2; Conformance testing for the Data Link Control (DLC) layer; Part 4: Extension for Home Environment; Sub-part 1: Protocol Implementation Conformance Statement (PICS) proforma“. 8 ETSI TS 101 811-1-1: “Broadband Radio Access Networks (BRAN); HIPERLAN Type 2; Conforman
25、ce testing for the packet based convergence layer; Part 1: Common part; Sub-part 1: Protocol Implementation Conformance Statement (PICS) proforma“. 9 Void. 10 ETSI TS 101 811-3-1: “Broadband Radio Access Networks (BRAN); HIPERLAN Type 2; Conformance testing for the packet based convergence layer; Pa
26、rt 3: IEEE 1394 Service Specific Convergence Sublayer (SSCS); Sub-part 1: Protocol Implementation Conformance Statement (PICS) proforma“. 11 ITU-T Recommendation X.509: “Information technology - Open Systems Interconnection - The Directory: Public-key and attribute certificate frameworks“. ETSI ETSI
27、 TS 101 823-5-1 V1.3.1 (2004-08) 6 12 ETSI TS 101 493-3: “Broadband Radio Access Networks (BRAN); HIPERLAN Type 2; Packet based Convergence Layer; Part 3: IEEE 1394 Service Specific Convergence Sublayer (SSCS)“. 13 ETSI TS 101 493-2: “Broadband Radio Access Networks (BRAN); HIPERLAN Type 2; Packet b
28、ased Convergence Layer; Part 2: Ethernet Service Specific Convergence Sublayer (SSCS)“. 3 Definitions and abbreviations 3.1 Definitions For the purposes of the present document, the terms and definitions given in TS 101 761-51, ISO/IEC 9646-1 3, ISO/IEC 9646-7 4 and the following apply: Implementati
29、on Conformance Statement (ICS): statement made by the supplier of an implementation or system claimed to conform to a given specification, stating which capabilities have been implemented NOTE: The ICS can take several forms: protocol ICS, profile ICS, profile specific ICS, information object ICS, e
30、tc. ICS proforma: document, in the form of a questionnaire, which when completed for an implementation or system becomes an ICS Profile ICS: ICS for an implementation or system claimed to conform to a given profile specification Protocol ICS (PICS): ICS for an implementation or system claimed to con
31、form to a given protocol specification Profile Requirement List (PRL): requirement list for an implementation or system claimed to conform to a given profile specification 3.2 Abbreviations For the purposes of the present document, the following abbreviations apply: ACF Association Control Function
32、AP Access Point CC Central Controller CL Convergence Layer DiL Direct Link DLC Data Link Control DUCC DLC User Connection Control FCA Fixed Capacity Agreement HE Home Environment HO HandOver ICS Implementation Conformance Statement IEC International Electrotechnical CommissionIEEE Institute of Elect
33、rical and Electronic Engineers ISO International Organization for Standardization MT Mobile Terminal PDU Protocol Data Unit PICS Protocol ICS PRL Profile Requirement List RLC Radio Link Control RRC Radio Resource Control TS Technical Specification UBCH User Broadcast Channel UDCH User Data Channel W
34、T Wireless Terminal ETSI ETSI TS 101 823-5-1 V1.3.1 (2004-08) 7 4 Conformance to this PRL proforma specification If it claims to conform to the present document, the actual PICS proformas to be filled in by a supplier shall be technically equivalent to the text of the PICS proformas given in referen
35、ce and shall preserve the numbering/naming and ordering of the proforma it. In addition, the PRL of annex A or annex B or both PRLs to be filled in by a supplier shall be technically equivalent to the text of this proforma. ETSI ETSI TS 101 823-5-1 V1.3.1 (2004-08) 8 Annex A (normative): Profile req
36、uirement list for HOME profile using TS 101 493-3 specification as convergence sub layer A.1 Purpose and structure The purpose of this requirement list is to specify the modifications that apply to the status of the items affected in the ICS proforma of each base specification. A.2 Impact on PICS pr
37、oforma for DLC layer (CC and WT implementations) A.2.1 Basic Data Transport This clause identifies the modifications to the requirements expressed in: TS 101 823-1-1:“ Broadband Radio Access Networks (BRAN); HIPERLAN Type 2; Conformance testing for the Data Link Control (DLC) layer; Part 1: Basic da
38、ta transport functions; Sub-part 1: Protocol Implementation Conformance Statement (PICS) proforma“. Table A.1: Error control modes Item Error control mode CC WT Profile reference Profile status Profile reference Profile status 1 Acknowledged mode UDCH 6.2 o.1 6.2 m 2 Repetition mode UBCH 6.2 o.1 6.2
39、 m 3 Unacknowledged mode 6.2 o.1 6.2 m o.1: It is mandatory for the CC to support at least one of these EC modes. This home profile confirms the mandatory status for the WT. Table A.2: MAC functions Item function CC WT Profile reference Profile status Profile reference Profile status 1 Fixed Capacit
40、y Agreement FCA 6.1 m 6.1 m This home profile changes the status for the Fixed Capacity Agreement to make it mandatory for CC and WT. A.2.1 DLC extensions This clause identifies the modifications to the requirements expressed in: TS 101 823-4-1:“ Broadband Radio Access Networks (BRAN); HIPERLAN Type
41、 2; Conformance testing for the Data Link Control (DLC) layer; Part 4: Extension for Home Environment; Sub-part 1: Protocol Implementation Conformance Statement (PICS) proforma“. ETSI ETSI TS 101 823-5-1 V1.3.1 (2004-08) 9 Table A.3: Error control modes Item Error control mode CC WT Profile referenc
42、e Profile status Profile reference Profile status 1 FEC mode for isochronous capable devices 8.1 m 8.1 m A.3 Impact on PICS proforma for Radio Link Control (RLC) protocol A.3.1 WT implementation The following clauses identify the modifications to the WT requirements expressed in reference 6: TS 101
43、823-2-1: “Broadband Radio Access Networks (BRAN); HIPERLAN Type 2; Conformance testing for the Data Link Control (DLC) layer; Part 2: Radio Link Control (RLC) sublayer; Sub-part 1: Protocol Implementation Conformance Statement (PICS) proforma“. The modifications apply to clauses of the referenced PI
44、CS, which deal with the MT (or WT) functionalities. A.3.1.1 Broadcast and multicast function Table A.4: WT broadcast/multicast procedures Item capabilities Profile reference Profile status 1 Multicast with multicast addressing 7.1.3 o.2 2 Multicast with N unicast addressing 7.1.3 o.2 3 Broadcast 7.1
45、.3 m o.2: It is mandatory for the WT to support at least one of these multicast modes. A.3.1.2 Association Control Function (ACF) Table A.5: connection modes and link capabilities Item capabilities Profile reference Profile status 1 Centralized mode 6.1 m 2 Direct mode 6.1 m This home profile change
46、s the status for the direct mode support to make it mandatory for WT. Table A.6: Association functions Item capabilities Profile reference Profile status 1 WT initiates Association request message 7.1.1 m 2 WT initiates info transfer procedure with AP (or with WT for Direct Link purpose) 7.1.1 m ETS
47、I ETSI TS 101 823-5-1 V1.3.1 (2004-08) 10Table A.7: Security functions Item capabilities Profile reference Profile status 1 Direct mode common key distribution 7.1.1 m Table A.8: Authentication protocols and key identifiers Item capabilities Profile reference Profile status 1 IEEE address 7.1.1 o 2
48、Extended IEEE address 7.1.1 o 3 Network access identifier 7.1.1 o 4 Distinguished name X509 11 7.1.1 o 5 Compressed type 7.1.1 o 6 Generic type 7.1.1 m This home profile changes the status for generic type as authentication key identifier to make it mandatory for WT. All other key identifiers remain
49、 optional. Table A.9: Key management Item capabilities Profile reference Profile status 1 Common keys 7.1.2 m 2 Common key refresh 7.1.2 m A.3.1.3 Radio Resource Control functions (RRC) Table A.10: RRC procedures for WT Item capabilities Profile reference Profile status 1 WT supports handover 7.2.1 o 2 WT supports DL power saving 7.2.2 o This home profile keeps the status of handover as optional. Consequence is that all handover procedures remain optional, as listed in the next table. Table A.11: Handover procedures for WT