1、 ETSI TS 102 872 V1.1.1 (2010-07)Technical Specification Access, Terminals, Transmission and Multiplexing (ATTM);Copper External Network Testing InterfaceETSI ETSI TS 102 872 V1.1.1 (2010-07)2Reference DTS/ATTM-02009 Keywords cable, interface ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cede
2、x - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Important notice Individual copies of the present document can be downloaded from: http:/www.etsi.org The present documen
3、t may be made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF
4、 version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at http:/portal.etsi.org/tb/status/status
5、.asp If you find errors in the present document, please send your comment to one of the following services: http:/portal.etsi.org/chaircor/ETSI_support.asp Copyright Notification No part may be reproduced except as authorized by written permission. The copyright and the foregoing restriction extend
6、to reproduction in all media. European Telecommunications Standards Institute 2010. All rights reserved. DECTTM, PLUGTESTSTM, UMTSTM, TIPHONTM, the TIPHON logo and the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members. 3GPPTM is a Trade Mark of ETSI registered for the benef
7、it of its Members and of the 3GPP Organizational Partners. LTE is a Trade Mark of ETSI currently being registered for the benefit of its Members and of the 3GPP Organizational Partners. GSM and the GSM logo are Trade Marks registered and owned by the GSM Association. ETSI ETSI TS 102 872 V1.1.1 (201
8、0-07)3Contents Intellectual Property Rights 4g3Foreword . 4g3Introduction 4g31 Scope 5g32 References 5g32.1 Normative references . 5g32.2 Informative references 6g33 Definitions and abbreviations . 6g33.1 Definitions 6g33.2 Abbreviations . 6g34 Functional characteristics . 7g34.1 Functional Diagram
9、of the ENTI 7g34.2 Copper ENTI location 7g34.3 Test interface 8g34.3.1 Generalities. 8g34.3.2 RJ45 connection 8g35 Particular characteristics. 8g35.1 Environmental conditions . 8g35.2 Installation and dimensioning. 8g35.3 Connection of the cable from the operator network (drop cable) . 8g35.4 Connec
10、tion of the customers cable 9g35.5 Test module 9g35.6 Test point and electrical measurements 9g35.7 Miscellaneous . 9g35.8 Documentation . 9g35.9 Recycling 10g36 Test Board 10g3History 13g3ETSI ETSI TS 102 872 V1.1.1 (2010-07)4Intellectual Property Rights IPRs essential or potentially essential to t
11、he present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETS
12、I in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/webapp.etsi.org/IPR/home.asp). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given
13、as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This Technical Specification (TS) has been produced by ETSI Technical Committee Access, Terminals, Transmission
14、 and Multiplexing (ATTM). Introduction The present document defines the functional and technical characteristics applicable to the External Network Testing Interface ENTI RJ45 which defines the point for testing the operators network while isolated from the customers home wiring. ETSI ETSI TS 102 87
15、2 V1.1.1 (2010-07)51 Scope The present document specifies rules to the copper RJ45 ENTI in the case of copper access network. 2 References References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cit
16、ed version applies. For non-specific references, the latest version of the reference document (including any amendments) applies. Referenced documents which are not found to be publicly available in the expected location might be found at http:/docbox.etsi.org/Reference. NOTE: While any hyperlinks i
17、ncluded in this clause were valid at the time of publication ETSI cannot guarantee their long term validity. 2.1 Normative references The following referenced documents are necessary for the application of the present document. 1 CENELEC EN 60603-7 (all sub-parts): “Connectors for electronic equipme
18、nt - Part 7: Detail specification for 8-way, unshielded, free and fixed connectors“. 2 CENELEC EN 50441-1: “Cables for indoor residential telecommunication installations - Part 1: Unscreened cables“. 3 CENELEC EN 50441-2: “Cables for indoor residential telecommunication installations - Part 2: Scree
19、ned cables“. 4 CENELEC EN 50441-3: “Cables for indoor residential telecommunication installations - Part 3: Screened cables“. 5 CENELEC EN 50406 (all parts): “End user multi-pair cables used in high bit rate telecommunication networks“. 6 CENELEC EN 50407-1: “Multi-pair cables used in high bit rate
20、digital access telecommunication networks - Part 1: Outdoor cables“. 7 CENELEC EN 60950-1: “Information technology equipment - Safety - Part 1: General requirements“. 8 CENELEC EN 60512-2 (all parts): “Connectors for electronic equipment - Tests and measurements“. 9 CENELEC EN 60529: “Degrees of pro
21、tection provided by enclosures (IP Code)“. 10 CENELEC EN 60068-2 (all parts): “Environmental testing“. 11 CENELEC EN 62262: “Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)“. 12 ETSI ETS 300 019-1-3: “Equipment Engineering (EE); Env
22、ironmental conditions and environmental tests for telecommunications equipment; Part 1-3: Classification of environmental conditions; Stationary use at weatherprotected locations“. ETSI ETSI TS 102 872 V1.1.1 (2010-07)62.2 Informative references The following referenced documents are not necessary f
23、or the application of the present document but they assist the user with regard to a particular subject area. i.1 Miniature 6-position plug as described in FCC 47, CFR 68.500: “Code of Federal Regulations (USA); Title 47 Telecommunication; Chapter 1 Federal Communications Commission, Part 68 Connect
24、ion of Terminal Equipment to the Telephone Network; Subpart F Connectors; Section 68.500 Specification“. 3 Definitions and abbreviations 3.1 Definitions For the purposes of the present document, the following terms and definitions apply: distribution space: location in the customer premise enclosing
25、 physical telecommunication interfaces, normally lockable that may house the home distributor and associated equipment 3.2 Abbreviations For the purposes of the present document, the following abbreviations apply: ENTI External Network Testing Interface HD Home Distributor HDMI High Definition Multi
26、media Interface POTS Plain Old Telephone Service STB Set Top Box VoIP Voice over IP xDSL Digital Subscriber Line ETSI ETSI TS 102 872 V1.1.1 (2010-07)74 Functional characteristics 4.1 Functional Diagram of the ENTI Figure 1 shows the diagram of the copper RJ45 ENTI. Drop cableHome WiringBranch 1Bran
27、ch 2TEST MODULEP0 JACKFigure 1: Functional diagram of RJ45 ENTI 4.2 Copper ENTI location The location of the copper ENTI is inside the distribution space within the Home Distributor (HD) as shown in figure 2. Figure 2: Copper RJ45 ENTI within the distribution space ETSI ETSI TS 102 872 V1.1.1 (2010-
28、07)84.3 Test interface 4.3.1 Generalities The test outlet is located in the front of the ENTI, it is called P0 jack. In normal use (no insertion in P0), the ENTI ensures continuity between the line of the operators network and the customers wiring. The separation of the network with customers wiring
29、 and the establishment of the communication on P0 is obtained only by the insertion of RJ45 plug. 4.3.2 RJ45 connection The P0 jack has the same dimensions as defined in EN 60603-7 1. It is designed to allow the insertion of RJ45 plug in accordance with EN 60603-7 1 and RJ11 plug in accordance with
30、FCC 47 C F R Ch i.1. The line is connected on pins 4 and 5 of P0. 5 Particular characteristics 5.1 Environmental conditions The environmental conditions of these materials are those applicable to the equipment of telecommunications in service, at fixed station, in sites protected from the bad weathe
31、r, at partially controlled temperature: classify 3.2 of ETS 300 019-1-3 12. 5.2 Installation and dimensioning The ENTI is designed: To be able to be fixed on a wall. To be able to be fixed on DIN rail of 35 mm. To have an attachment unit allowing horizontal/vertical adjustment. Not to require specif
32、ic tools for installation. To form part of a maximum volume of 100 100 35 mm. To ensure a protection against wet wall effects. 5.3 Connection of the cable from the operator network (drop cable) The ENTI is designed: To accept IDC (Insulated Displacement Connector) with a wire of gauge diameter from
33、0,5 mm to 0,8 mm To accept the various types of cables of the standards or following specifications: - EN 50406 5; - EN 50407-1 6; - EN 50441-1 2; - National standards of drop cable. ETSI ETSI TS 102 872 V1.1.1 (2010-07)9 To maintain the cables of customer wiring: - The maintenance of the cable will
34、 be marked on its sheath; - The cable will support a tensile strength of 1,5 daN. 5.4 Connection of the customers cable The ENTI is designed: To allow the connection of two branches of customer wiring (two connected directions, two connected wires). To accept IDC (Insulated Displacement Connector) w
35、ith a wire of gauge diameter from 0,5 mm to 0,8 mm. To accept the various types of cables of following standards: - EN 50441-1 2; - EN 50441-2 3; - EN 50441-3 4. To maintain the cables of customer wiring: - The maintenance of the cable will be marked on its sheath. - The cable will support a tensile
36、 strength of 1,5 daN. To allow the connection of the screens of the cables to the ground (when using screened F/UTP cable). 5.5 Test module The ENTI is designed to be equipped with a test module. 5.6 Test point and electrical measurements The ENTI is designed to allow the following tests: To be able
37、 to measure the tension between wires of the line at the connection of the access cable and at the connection of the customers cable(s). To measure the continuity of the device without connected cable (removed cover). To measure the continuity of the device without disconnecting the cables. 5.7 Misc
38、ellaneous The inscription “TEST“ or another symbol is present beside the P0 jack. 5.8 Documentation In each package of ENTI, documentation will be provided including a technical note of installation and a technical note of exploitation and maintenance. ETSI ETSI TS 102 872 V1.1.1 (2010-07)105.9 Recy
39、cling The ENTI is designed: To limit the number of components and materials. To support the concept facilitating the recycling of materials. To provide the indications necessary for the recycling of the material at the end of the lifetime. To provide a mechanical protection of the connector industry
40、 (case). To respect the safety requirements EN 60950-1 7. 6 Test Board The purpose of the tests described hereafter, applicable to copper ENTI RJ45 are to allow the checking of all the design features required in the present specification. Table 6.1: Tests applicable to copper RJ45 ENTI and housing
41、Tests to carry out Standards or Specifications Sanctions Visual inspections and controls Following the test 1a of the EN 60512-2 8. According to the test 1a of the EN 60512-2 8. Test of implementation The test with for goal to test and check all the functions of the product. It makes it possible to
42、validate the proposed note of assembly and wiring. No observed deformation, no fracture of the various components or subset of the product. Test of reintervention The goal is to test the aptitude of ENTI RJ45 to support the mechanical constraints due to handling. No damage at the end of 10 complete
43、cycles of connection. Lay-out/deposits, test module The test has the goal to check that the efforts necessary for the installation and the demounting of a test module are such as they allow an easy exploitation of test module on ENTI RJ45. The acceptable maximum efforts will not be able to in no cas
44、e to be higher than 4 daN. Check test of the degree of envelope protection The test has the goal to check the level of protection of the envelope against the penetrations of objects EN 60529 9. The envelope will be in conformity with the index of protection IP30. Free shatter test EN 60068-2-32 10 m
45、ethod 1. No damage. Corrosion of Metal equipment EN 60068-2-11 10 Ka Test: salt spray during 96 hours. No trace of corrosion calling into question the functionality of the product should not be observed on the metal parts. Vibration test Classify 3.2 of standard ETS 300 019-1-3 12 following conditio
46、ns T 3.2. No damage, no microcuts 0,1 microsecond. At the end of the test each product must be able to answer all its functions perfectly. Impact resistance EN 62262 11 (IK 04). No observed displacement, no visual degradation (crossing cracking, fracture). ETSI ETSI TS 102 872 V1.1.1 (2010-07)11Beha
47、viour with the wrenching and the depression of the contacts The purpose of the test is to make sure that traction or accidental compressive forces exerted on the contacts cannot damage them. A test of wrenching is carried out by applying according to an axis perpendicular a tractive effort of 15 daN
48、 to each contact. A test of depression is applied while applying (according to the same axis but in the opposite direction), a compressive force of 15 daN to each contact. Behaviour with traction on the cord The purpose of the test is to check the mechanical resistance of the P0 jack to the wrenchin
49、g of a plug assembled in end of cord, and electric continuity on the level of each blade of contact, when the cord is subjected to efforts. This test will have to be carried out on the most exhaustive possible panel of existing plugs on the market, in order to check the compatibility of the existing products. No observed microcuts higher than 10 s. No deterioration mechanical nor variation of the resistance of contact of more than 10 milliohms should no